Protection mechanism and explanation OF ETO Sterilizer System
- ETO sterilizer system has six different levels of operation permissions. Personnel with different permissions can operate different contents to prevent operation confusion, or equipment failure or safety accident caused by operation by personnel without professional training
2. By default, the system will perform the leak detection test before dosing of each batch. If the leak detection test fails, the system will automatically stop the cycle and no longer continue, and the alarm will prompt

3.If the cabinet body leaks during the exposure stage of the equipment, the ETO chamber System will automatically jump to the cleaning stage to ensure that EO will not leak into the workshop and cause safety accidents
4. When the equipment is in operation, if it wants to stop the cycle halfway, the system will automatically jump to a safe processing process according to different operating conditions. For example, after dosing, the system needs forced cleaning to reset the whole process.
5. If the system is equipped with an electronic scale, as long as the equipment is powered on, you can check whether the weight of the EO cylinder changes abnormally at any time, so as to timely notify the equipment maintenance personnel of potential safety hazards
6. Le système de chambre ETO a pour fonction de détection et de protection à ultra-haute pression. Si le système détecte que la pression dans l'armoire est supérieure à la pression maximale admissible, que l'équipement soit en fonctionnement ou non, la pompe à vide doit être forcée à démarrer pour réduire la pression dans l'armoire afin d'empêcher le gaz dans l'armoire de s'échapper dans l'atelier, sinon l'armoire sera endommagée par la haute pression dans l'armoire.
7. Chaque fois que la porte est ouverte, le système de chambre ETO vérifiera si la pression dans l'armoire est dans la plage de sécurité et si l'état de fonctionnement dans l'armoire est dans un état sûr, sinon la porte sera verrouillée et ne pourra pas être ouverte.
8.In order to ensure personal safety, the equipment can be equipped with a harmless exhaust system. After the cabinet door is opened, ensure that the air in the workshop can only enter the cabinet, but cannot be discharged from the cabinet to the workshop environment
9.If the equipment has been cleaned but the door has not been opened, the system will automatically check the unloading timeout. If the unloading timeout is more than 30 minutes, the door will be locked and cannot be opened, and the cleaning process must be executed again. This function is used to ensure that EO in the product will not be slowly released into the workshop environment, causing pollution to the workshop environment and personal health damage
10.The whole control system has self-diagnosis function for all kinds of equipment and sensors, which is used to prevent the abnormal operation of the equipment in case of sensor failure, and at the same time prompt the maintenance personnel what sensor or equipment has failed, so that the maintenance personnel can quickly find and solve problems
11.The ETO sterilizer SYSTEM has more than 100 fault and alarm information, which allows operators and maintenance personnel to know the operation of the equipment in a timely and accurate manner, so that maintenance personnel can quickly find and solve problems
12.After downloading process parameters, if there are unreasonable parameters, there will be a prompt of download failure to prevent the operation of the whole batch from failing when the parameters are unreasonable
13.After downloading process parameters, if there are unreasonable parameters, there will be a prompt of download failure to prevent the operation of the whole batch from failing when the parameters are unreasonable
14. En cas de perte d'alimentation externe, l'UPS continuera à alimenter le système et l'équipement gérera l'état suspendu pour garantir que l'équipement ne fuira pas après une panne de courant et assurera un temps tampon de sécurité d'au moins 15 minutes. Une fois l'équipement arrêté selon le processus de fonctionnement normal, l'équipement peut toujours continuer à fonctionner lorsque l'alimentation externe est rétablie.
15. Lorsque l'IPC tombe en panne pendant le fonctionnement du système, l'IPC peut être redémarré directement et le logiciel peut automatiquement connecter l'enregistrement original.
16.Le système dispose d'une fonction de suivi d'audit détaillée, qui peut enregistrer presque toutes les actions opérationnelles pour faciliter l'analyse des accidents et la prévention des pannes à un stade ultérieur.
Contact
Téléphone:+8619975258603
E-mail:hayley@hzbocon.com
Site local : salle 1202, Caitong Zhongxin, district de Xiasha, ville de Hangzhou, province du Zhejiang, Chine
Site web:hzbocon.comzjbocon.com