{"id":2425,"date":"2024-12-17T10:45:20","date_gmt":"2024-12-17T02:45:20","guid":{"rendered":"https:\/\/zjbocon.com\/?p=2425"},"modified":"2026-02-09T09:58:51","modified_gmt":"2026-02-09T01:58:51","slug":"eo-sterilization-equipment-and-process-characteristic-patterns-and-effect-analysis","status":"publish","type":"post","link":"https:\/\/zjbocon.com\/?p=2425","title":{"rendered":"EO sterilization equipment and process characteristic patterns and effect analysis"},"content":{"rendered":"\n<div class=\"wp-block-uagb-image uagb-block-de5b384b wp-block-uagb-image--layout-default wp-block-uagb-image--effect-static wp-block-uagb-image--align-none\"><figure class=\"wp-block-uagb-image__figure\"><img loading=\"lazy\" decoding=\"async\" src=\"https:\/\/zjbocon.com\/wp-content\/uploads\/2025\/09\/ethylene-oxide-sterilization-68.webp\" alt=\"\" class=\"uag-image-8473\" width=\"1024\" height=\"768\" title=\"ethylene-oxide-sterilization-68\" role=\"img\" \><\/figure><\/div>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><tbody><tr><td colspan=\"16\">Start cycle phase(Select parameters\/sterilization recipe)<\/td><\/tr><tr><td rowspan=\"2\">Reeksnommer<\/td><td colspan=\"3\">Potensieel riskante inhoud<\/td><td colspan=\"5\">Risikobepaling onder bestaande prosestoestande<\/td><td colspan=\"5\">Risikobepaling van die resultate nadat maatreëls geneem is<\/td><td rowspan=\"2\">Aanbevole aksies<\/td><td rowspan=\"2\">Verantwoordelikhede en huidige status<\/td><\/tr><tr><td>Fout naam<\/td><td>Oorsaak<\/td><td>Mislukking impak<\/td><td>Beheer nou<\/td><td>gebeurtenis<\/td><td>Erns<\/td><td>ondersoek<\/td><td>Risikoprioritisering<\/td><td>Neem aksie<\/td><td>gebeurtenis<\/td><td>Erns<\/td><td>ondersoek<\/td><td>Risikoprioritisering<\/td><\/tr><tr><td rowspan=\"2\">1<\/td><td rowspan=\"2\">Om die verkeerde resep te kies<\/td><td rowspan=\"2\">Gebrek aan sorg in die keuse van die formulering<\/td><td>Ongeldige siklus. Beïnvloed produksteriliteit (hersterilisasie)<\/td><td>1. Verskillende resepname<\/td><td>6<\/td><td>5<\/td><td>10<\/td><td>300<\/td><td>1. Werksinstruksies 2. Noukeurige inspeksie voor die siklus begin 3. Operateursopleiding<\/td><td>2<\/td><td>5<\/td><td>4<\/td><td>40<\/td><td>1. Werksinstruksies 2. Noukeurige inspeksie voor die aanvang van die siklus 3. Operateursopleiding<\/td><td>gebruiker<\/td><\/tr><tr><td>Loss of product\/packaging functionality and integrity due to unvalidated cycle parameters<\/td><td>1. Verskillende resepname<\/td><td>6<\/td><td>4<\/td><td>10<\/td><td>240<\/td><td>1. Werksinstruksies 2. Noukeurige inspeksie voor die siklus begin 3. Operateursopleiding<\/td><td>2<\/td><td>4<\/td><td>4<\/td><td>32<\/td><td>1. Werksinstruksies 2. Noukeurige inspeksie voor die aanvang van die siklus 3. Operateursopleiding<\/td><td>gebruiker<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><tbody><tr><td colspan=\"16\">Opwarmingsfase (Kabinetverhitting)<\/td><\/tr><tr><td rowspan=\"2\">Reeksnommer<\/td><td colspan=\"3\">Potensieel riskante inhoud<\/td><td colspan=\"5\">Risikobepaling onder bestaande prosestoestande<\/td><td colspan=\"5\">Risikobepaling van die resultate nadat maatreëls geneem is<\/td><td rowspan=\"2\">Aanbevole aksies<\/td><td rowspan=\"2\">Verantwoordelikhede en huidige status<\/td><\/tr><tr><td>Fout naam<\/td><td>Oorsaak<\/td><td>Mislukking impak<\/td><td>Beheer nou<\/td><td>gebeurtenis<\/td><td>Erns<\/td><td>ondersoek<\/td><td>Risikoprioritisering<\/td><td>Neem aksie<\/td><td>gebeurtenis<\/td><td>Erns<\/td><td>ondersoek<\/td><td>Risikoprioritisering<\/td><\/tr><tr><td rowspan=\"3\">1<\/td><td rowspan=\"3\">Die bokstemperatuur is laer as die onderste grenswaarde<\/td><td>Warmwater sirkulasie pomp mislukking<\/td><td>Die siklus word in &#039;n stadium gesluit totdat dit herstel word en na &#039;n bystandtydperk weer begin word. Groepe wat die gekwalifiseerde siklus oorskry het, kan weer gesteriliseer word.<\/td><td>1. Verhitting-uittelalarm 2. Sirkulasiewaterpompoorladingalarm 3. Outomatiese verhittingstydkompensasie<\/td><td>5<\/td><td>3<\/td><td>2<\/td><td>30<\/td><td>1. Voorkomende instandhouding<\/td><td>2<\/td><td>3<\/td><td>2<\/td><td>12<\/td><td>1. Voorkomende instandhouding<\/td><td>gebruiker<\/td><\/tr><tr><td>Elektriese verwarmingsbuis mislukking<\/td><td>Die siklus word in &#039;n stadium gesluit totdat dit herstel word en na &#039;n bystandtydperk weer begin word. Groepe wat die gekwalifiseerde siklus oorskry het, kan weer gesteriliseer word.<\/td><td>1. Verhitting time-out alarm 2. Outomatiese verwarming tyd kompensasie<\/td><td>6<\/td><td>3<\/td><td>2<\/td><td>36<\/td><td>1. Voorkomende instandhouding<\/td><td>2<\/td><td>3<\/td><td>2<\/td><td>12<\/td><td>1. Voorkomende instandhouding<\/td><td>gebruiker<\/td><\/tr><tr><td>Temperatuursensor mislukking<\/td><td>Beïnvloed produksteriliteit (hersterilisasie)<\/td><td><br>1. Oortollige temperatuursensor 2. Temperatuurverskil oorskry limietalarm<\/td><td>6<\/td><td>5<\/td><td>2<\/td><td>60<\/td><td>1. Voorkomende instandhouding 2. Kalibrasie<\/td><td>2<\/td><td>5<\/td><td>2<\/td><td>20<\/td><td>1. Voorkomende instandhouding 2. Kalibrasie<\/td><td>gebruiker<\/td><\/tr><tr><td>2<\/td><td>Die temperatuur binne die kas is te hoog<\/td><td>Temperatuursensor mislukking<\/td><td>Beïnvloed produksteriliteit (hersterilisasie)<\/td><td><br>1. Oortollige temperatuursensor 2. Temperatuurverskil oorskry limietalarm<\/td><td>6<\/td><td>4<\/td><td>2<\/td><td>48<\/td><td>1. Voorkomende instandhouding 2. Kalibrasie<\/td><td>2<\/td><td>4<\/td><td>2<\/td><td>16<\/td><td>1. Voorkomende instandhouding 2. Kalibrasie<\/td><td>gebruiker<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><tbody><tr><td colspan=\"16\">Isolasie stadium (handhaaf kastemperatuur)<\/td><\/tr><tr><td rowspan=\"2\">Reeksnommer<\/td><td colspan=\"3\">Potensieel riskante inhoud<\/td><td colspan=\"5\">Risikobepaling onder bestaande prosestoestande<\/td><td colspan=\"5\">Risikobepaling van die resultate nadat maatreëls geneem is<\/td><td rowspan=\"2\">Aanbevole aksies<\/td><td rowspan=\"2\">Verantwoordelikhede en huidige status<\/td><\/tr><tr><td>Fout naam<\/td><td>Oorsaak<\/td><td>Mislukking impak<\/td><td>Beheer nou<\/td><td>gebeurtenis<\/td><td>Erns<\/td><td>ondersoek<\/td><td>Risikoprioritisering<\/td><td>Neem aksie<\/td><td>gebeurtenis<\/td><td>Erns<\/td><td>ondersoek<\/td><td>Risikoprioritisering<\/td><\/tr><tr><td rowspan=\"3\">1<\/td><td rowspan=\"3\">Die bokstemperatuur is laer as die onderste grenswaarde<\/td><td>Warmwater sirkulasie pomp mislukking<\/td><td>Die siklus word in &#039;n stadium gesluit totdat dit herstel word en na &#039;n bystandtydperk weer begin word. Groepe wat die gekwalifiseerde siklus oorskry het, kan weer gesteriliseer word.<\/td><td>1. Verhitting-uittelalarm 2. Sirkulasiewaterpompoorladingsalarm<\/td><td>5<\/td><td>3<\/td><td>2<\/td><td>30<\/td><td>1. Voorkomende instandhouding<\/td><td>2<\/td><td>3<\/td><td>2<\/td><td>12<\/td><td>1. Voorkomende instandhouding<\/td><td>gebruiker<\/td><\/tr><tr><td>Elektriese verwarmingsbuis mislukking<\/td><td>Die siklus word in &#039;n stadium gesluit totdat dit herstel word en na &#039;n bystandtydperk weer begin word. Groepe wat die gekwalifiseerde siklus oorskry het, kan weer gesteriliseer word.<\/td><td>1. Verhitting time-out alarm<\/td><td>6<\/td><td>3<\/td><td>2<\/td><td>36<\/td><td>1. Voorkomende instandhouding<\/td><td>2<\/td><td>3<\/td><td>2<\/td><td>12<\/td><td>1. Voorkomende instandhouding<\/td><td>gebruiker<\/td><\/tr><tr><td>Temperatuursensor mislukking<\/td><td>Beïnvloed produksteriliteit (hersterilisasie)<\/td><td>1. Verhitting-uittelalarm 2. Sirkulasiewaterpompoorladingsalarm<\/td><td>6<\/td><td>5<\/td><td>2<\/td><td>60<\/td><td>1. Voorkomende instandhouding 2. Kalibrasie<\/td><td>2<\/td><td>5<\/td><td>2<\/td><td>20<\/td><td>1. Voorkomende instandhouding 2. Kalibrasie<\/td><td>gebruiker<\/td><\/tr><tr><td>2<\/td><td>Die temperatuur binne die kas is te hoog<\/td><td>Temperatuursensor mislukking<\/td><td>Beïnvloed produksteriliteit (hersterilisasie)<\/td><td>1. Verhitting-uittelalarm 2. Sirkulasiewaterpompoorladingsalarm<\/td><td>6<\/td><td>4<\/td><td>2<\/td><td>48<\/td><td>1. Voorkomende instandhouding 2. Kalibrasie<\/td><td>2<\/td><td>4<\/td><td>2<\/td><td>16<\/td><td>1. Voorkomende instandhouding 2. Kalibrasie<\/td><td>gebruiker<\/td><\/tr><tr><td>3<\/td><td>Gebrek aan tyd<\/td><td>Programmeringsfoute<\/td><td>Herhaal sterilisasie<\/td><td>1. Outomatiese siklus inspeksie<\/td><td>2<\/td><td>4<\/td><td>2<\/td><td>16<\/td><td><\/td><td><\/td><td><\/td><td><\/td><td><\/td><td>geen<\/td><td><\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><tbody><tr><td colspan=\"16\">Voorvakuumstadium (Verwydering van lug uit die kamer laat die proses onder die EO-vlambaarheidsgrens voort)<\/td><\/tr><tr><td rowspan=\"2\">Reeksnommer<\/td><td colspan=\"3\">Potensieel riskante inhoud<\/td><td colspan=\"5\">Risikobepaling onder bestaande prosestoestande<\/td><td colspan=\"5\">Risikobepaling van die resultate nadat maatreëls geneem is<\/td><td rowspan=\"2\">Aanbevole aksies<\/td><td rowspan=\"2\">Verantwoordelikhede en huidige status<\/td><\/tr><tr><td>Fout naam<\/td><td>Oorsaak<\/td><td>Mislukking impak<\/td><td>Beheer nou<\/td><td>gebeurtenis<\/td><td>Erns<\/td><td>ondersoek<\/td><td>Risikoprioritisering<\/td><td>Neem aksie<\/td><td>gebeurtenis<\/td><td>Erns<\/td><td>ondersoek<\/td><td>Risikoprioritisering<\/td><\/tr><tr><td rowspan=\"3\">1<\/td><td rowspan=\"3\">Nie genoeg lug verwyder nie<\/td><td>Lae vakuumpompdoeltreffendheid<\/td><td>Die siklus word in een fase gesluit totdat dit herstel en na &#039;n bystandtydperk weer begin word<\/td><td>1. Pre-vakuum tyd oor limiet alarm 2. Vakuum pomp oorlading alarm 3. Bespeur outomaties watervloei en skakel die waterlose pomp af<\/td><td>5<\/td><td>3<\/td><td>2<\/td><td>30<\/td><td>1. Voorkomende instandhouding<\/td><td>2<\/td><td>3<\/td><td>2<\/td><td>12<\/td><td>1. Voorkomende instandhouding<\/td><td>gebruiker<\/td><\/tr><tr><td>Verkeerde klep<\/td><td>Die siklus word in een fase gesluit totdat dit herstel en na &#039;n bystandtydperk weer begin word<\/td><td>1. Pre-vakuum tyd oor limiet alarm 2. Vakuum pomp oorlading alarm<\/td><td>6<\/td><td>3<\/td><td>2<\/td><td>36<\/td><td>1. Voorkomende instandhouding<\/td><td>2<\/td><td>3<\/td><td>2<\/td><td>12<\/td><td>1. Voorkomende instandhouding<\/td><td>gebruiker<\/td><\/tr><tr><td>Druksensor mislukking<\/td><td>Vlambare Sone Gevaar<\/td><td>1. Oortollige druksensor 2. Alarm wanneer drukverskil limiet oorskry<\/td><td>6<\/td><td>3<\/td><td>2<\/td><td>36<\/td><td>1. Voorkomende instandhouding 2. Kalibrasie<\/td><td>2<\/td><td>3<\/td><td>2<\/td><td>12<\/td><td>1. Voorkomende instandhouding 2. Kalibrasie<\/td><td>gebruiker<\/td><\/tr><tr><td>2<\/td><td>Te veel vakuum<\/td><td>Druksensor mislukking<\/td><td>Product and\/or packaging damage (classification)<\/td><td>1. Oortollige druksensor 2. Drukverskilalarm word uitgereik wanneer die drukverskil groter as 1kpa is.<\/td><td>6<\/td><td>4<\/td><td>2<\/td><td>48<\/td><td>1. Voorkomende instandhouding 2. Kalibrasie<\/td><td>2<\/td><td>4<\/td><td>2<\/td><td>16<\/td><td>1. Voorkomende instandhouding 2. Kalibrasie<\/td><td>gebruiker<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><tbody><tr><td colspan=\"16\">Stadium vir lekopsporing (kontroleer die digtheid van die boks)<\/td><\/tr><tr><td rowspan=\"2\">Reeksnommer<\/td><td colspan=\"3\">Potensieel riskante inhoud<\/td><td colspan=\"5\">Risikobepaling onder bestaande prosestoestande<\/td><td colspan=\"5\">Risikobepaling van die resultate nadat maatreëls geneem is<\/td><td rowspan=\"2\">Aanbevole aksies<\/td><td rowspan=\"2\">Verantwoordelikhede en huidige status<\/td><\/tr><tr><td>Fout naam<\/td><td>Oorsaak<\/td><td>Mislukking impak<\/td><td>Beheer nou<\/td><td>gebeurtenis<\/td><td>Erns<\/td><td>ondersoek<\/td><td>Risikoprioritisering<\/td><td>Neem aksie<\/td><td>gebeurtenis<\/td><td>Erns<\/td><td>ondersoek<\/td><td>Risikoprioritisering<\/td><\/tr><tr><td rowspan=\"3\">1<\/td><td rowspan=\"3\">Kabinet lekkasie<\/td><td>Gasket lekkasie<\/td><td>Geen impak nie<\/td><td>1. Lek toets mislukking alarm 2. Proses eindig<\/td><td>10<\/td><td>5<\/td><td>2<\/td><td>100<\/td><td>1. Voorkomende instandhouding<\/td><td>3<\/td><td>5<\/td><td>2<\/td><td>30<\/td><td>1. Voorkomende instandhouding<\/td><td>gebruiker<\/td><\/tr><tr><td>Klep lekkasie<\/td><td>Geen impak nie<\/td><td>1. Lek toets mislukking alarm<\/td><td>6<\/td><td>3<\/td><td>2<\/td><td>36<\/td><td>1. Voorkomende instandhouding<\/td><td>2<\/td><td>3<\/td><td>2<\/td><td>12<\/td><td>1. Voorkomende instandhouding<\/td><td>gebruiker<\/td><\/tr><tr><td>Sirkulasiestelsel lugkanaal lekkasie<\/td><td>Geen impak nie<\/td><td>1. Lek toets mislukking alarm<\/td><td>4<\/td><td>3<\/td><td>2<\/td><td>24<\/td><td>1. Voorkomende instandhouding<\/td><td>2<\/td><td>3<\/td><td>2<\/td><td>12<\/td><td>1. Voorkomende instandhouding 2. Kalibrasie<\/td><td>gebruiker<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><tbody><tr><td colspan=\"16\">Stikstofvervangingstadium (Vul die kamer met &#039;n inerte gas om suurstof te vervang)<\/td><\/tr><tr><td rowspan=\"2\">Reeksnommer<\/td><td colspan=\"3\">Potensieel riskante inhoud<\/td><td colspan=\"5\">Risikobepaling onder bestaande prosestoestande<\/td><td colspan=\"5\">Risikobepaling van die resultate nadat maatreëls geneem is<\/td><td rowspan=\"2\">Aanbevole aksies<\/td><td rowspan=\"2\">Verantwoordelikhede en huidige status<\/td><\/tr><tr><td>Fout naam<\/td><td>Oorsaak<\/td><td>Mislukking impak<\/td><td>Beheer nou<\/td><td>gebeurtenis<\/td><td>Erns<\/td><td>ondersoek<\/td><td>Risikoprioritisering<\/td><td>Neem aksie<\/td><td>gebeurtenis<\/td><td>Erns<\/td><td>ondersoek<\/td><td>Risikoprioritisering<\/td><\/tr><tr><td rowspan=\"3\">1<\/td><td rowspan=\"3\">Nie genoeg stikstof kom die kamer binne nie<\/td><td>Onvoldoende stikstof<\/td><td>Die siklus word in een fase gesluit totdat dit herstel en na &#039;n bystandtydperk weer begin word<\/td><td>Einde van proses<\/td><td>3<\/td><td>3<\/td><td>2<\/td><td>18<\/td><td><\/td><td><\/td><td><\/td><td><\/td><td><\/td><td>N\/A<\/td><td><\/td><\/tr><tr><td>Foutiewe klep<\/td><td>Die siklus word in een fase gesluit totdat dit herstel en na &#039;n bystandtydperk weer begin word<\/td><td>N\/A<\/td><td>6<\/td><td>3<\/td><td>3<\/td><td>54<\/td><td>1. Voorkomende instandhouding<\/td><td>2<\/td><td>3<\/td><td>3<\/td><td>18<\/td><td>1. Voorkomende instandhouding<\/td><td>gebruiker<\/td><\/tr><tr><td>Druksensor mislukking<\/td><td>Vlambare Sone Gevaar<\/td><td>1. Oortollige druksensor 2. Alarm wanneer drukverskil limiet oorskry<\/td><td>6<\/td><td>3<\/td><td>2<\/td><td>36<\/td><td>1. Voorkomende instandhouding<\/td><td>2<\/td><td>3<\/td><td>2<\/td><td>12<\/td><td>1. Voorkomende instandhouding<\/td><td>gebruiker<\/td><\/tr><tr><td rowspan=\"2\">2<\/td><td rowspan=\"2\">Te veel stikstof in die kasdeur<\/td><td>Foutiewe klep<\/td><td>EO-konsentrasie is laer as die gevalideerde waarde, want tydens EO-inspuiting, indien dit deur druk (hersterilisasie) beheer word, word addisionele N2 ingespuit<\/td><td>1. Binnehuise hoogspanningsalarm 2. Einde van proses<\/td><td>6<\/td><td>5<\/td><td>4<\/td><td>120<\/td><td>1. Voorkomende instandhouding<\/td><td>2<\/td><td>5<\/td><td>4<\/td><td>40<\/td><td>1. Voorkomende instandhouding<\/td><td>gebruiker<\/td><\/tr><tr><td>Druksender mislukking<\/td><td>Te veel EO gas ingespuit. Hoë EO-residu. Verlengde ontgassingstyd my)<\/td><td>1. Oortollige druksensor 2. Alarm wanneer drukverskil limiet oorskry<\/td><td>6<\/td><td>5<\/td><td>2<\/td><td>60<\/td><td>1. Voorkomende instandhouding 2. Kalibrasie<\/td><td>2<\/td><td>5<\/td><td>2<\/td><td>20<\/td><td>1. Voorkomende instandhouding 2. Kalibrasie<\/td><td>gebruiker<\/td><\/tr><tr><td>3<\/td><td>Die kastemperatuur is hoër as die boonste limiet t<\/td><td><\/td><td>Impak op produkfunksie (sortering)<\/td><td>1. Oortollige druksensor 2. Alarm wanneer drukverskil limiet oorskry<\/td><td>6<\/td><td>4<\/td><td>2<\/td><td>48<\/td><td>1. Voorkomende instandhouding 2. Kalibrasie<\/td><td>2<\/td><td>4<\/td><td>2<\/td><td>16<\/td><td>1. Voorkomende instandhouding 2. Kalibrasie<\/td><td>gebruiker<\/td><\/tr><tr><td rowspan=\"4\">4<\/td><td rowspan=\"4\">Die bokstemperatuur is laer as die onderste grenswaarde<\/td><td>Warmwater sirkulasie pomp mislukking<\/td><td>Die siklus word in &#039;n stadium gesluit totdat dit herstel word en na &#039;n bystandtydperk weer begin word. Groepe wat die gekwalifiseerde siklus oorskry het, kan weer gesteriliseer word.<\/td><td>1. Verhitting-uittelalarm 2. Sirkulasiewaterpompoorladingalarm 3. Outomatiese verhittingstydkompensasie<\/td><td>6<\/td><td>3<\/td><td>2<\/td><td>36<\/td><td>1. Voorkomende instandhouding<\/td><td>2<\/td><td>3<\/td><td>2<\/td><td>12<\/td><td>1. Voorkomende instandhouding<\/td><td>gebruiker<\/td><\/tr><tr><td>Elektriese verwarmingsbuis mislukking<\/td><td>Die siklus word in &#039;n stadium gesluit totdat dit herstel word en na &#039;n bystandtydperk weer begin word. Groepe wat die gekwalifiseerde siklus oorskry het, kan weer gesteriliseer word.<\/td><td>1. Verhitting time-out alarm 2. Outomatiese verwarming tyd kompensasie<\/td><td>6<\/td><td>3<\/td><td>3<\/td><td>54<\/td><td>1. Voorkomende instandhouding<\/td><td>2<\/td><td>3<\/td><td>3<\/td><td>18<\/td><td>1. Voorkomende instandhouding<\/td><td>gebruiker<\/td><\/tr><tr><td>Temperatuursensor mislukking<\/td><td>Beïnvloed produksteriliteit (hersterilisasie)<\/td><td>1. Oortollige temperatuursensor 2. Temperatuurverskil oorskry limietalarm<\/td><td>6<\/td><td>5<\/td><td>2<\/td><td>60<\/td><td>1. Voorkomende instandhouding 2. Kalibrasie<\/td><td>2<\/td><td>5<\/td><td>2<\/td><td>20<\/td><td>1. Voorkomende instandhouding 2. Kalibrasie<\/td><td>gebruiker<\/td><\/tr><tr><td>Lae vergasser temperatuur<\/td><td>Beïnvloed produksteriliteit (hersterilisasie)<\/td><td>1. Alarm wanneer die vergasser temperatuur laer is as die limiet 2. Outomatiese verwarming tyd kompensasie<\/td><td>6<\/td><td>4<\/td><td>2<\/td><td>48<\/td><td>1. Voorkomende instandhouding<\/td><td>2<\/td><td>4<\/td><td>2<\/td><td>16<\/td><td>1. Voorkomende instandhouding<\/td><td>gebruiker<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><tbody><tr><td colspan=\"16\">Humidifikasie stadium (Verhoog die humiditeit van die vrag deur stoom in te spuit)<\/td><\/tr><tr><td rowspan=\"2\">Reeksnommer<\/td><td colspan=\"3\">Potensieel riskante inhoud<\/td><td colspan=\"5\">Risikobepaling onder bestaande prosestoestande<\/td><td colspan=\"5\">Risikobepaling van die resultate nadat maatreëls geneem is<\/td><td rowspan=\"2\">Aanbevole aksies<\/td><td rowspan=\"2\">Verantwoordelikhede en huidige status<\/td><\/tr><tr><td>Fout naam<\/td><td>Oorsaak<\/td><td>Mislukking impak<\/td><td>Beheer nou<\/td><td>gebeurtenis<\/td><td>Erns<\/td><td>ondersoek<\/td><td>Risikoprioritisering<\/td><td>Neem aksie<\/td><td>gebeurtenis<\/td><td>Erns<\/td><td>ondersoek<\/td><td>Risikoprioritisering<\/td><\/tr><tr><td rowspan=\"4\">1<\/td><td rowspan=\"4\">Onvoldoende stoom<\/td><td>Stoomgenerator mislukking<\/td><td>Beïnvloed produksteriliteit (hersterilisasie)<\/td><td>1. Alarm wanneer stoomdruk laer as die limiet is<\/td><td>6<\/td><td>5<\/td><td>2<\/td><td>60<\/td><td>1. Voorkomende instandhouding<\/td><td>2<\/td><td>5<\/td><td>2<\/td><td>20<\/td><td>1. Voorkomende instandhouding<\/td><td>gebruiker<\/td><\/tr><tr><td>Klep mislukking<\/td><td>Die siklus word in een fase gesluit totdat dit herstel en na &#039;n bystandtydperk weer begin word<\/td><td>1. Humidification frekwensie limiet alarm<\/td><td>6<\/td><td>5<\/td><td>2<\/td><td>60<\/td><td>1. Voorkomende instandhouding<\/td><td>2<\/td><td>5<\/td><td>2<\/td><td>20<\/td><td>1. Voorkomende instandhouding<\/td><td>gebruiker<\/td><\/tr><tr><td>Pressure transmitter\/humidity sensor failure<\/td><td>Beïnvloed produksteriliteit (hersterilisasie)<\/td><td>1. Redundant pressure\/humidity sensor 2. Alarm when pressure\/humidity difference exceeds limit<\/td><td>6<\/td><td>5<\/td><td>2<\/td><td>60<\/td><td>1. Voorkomende instandhouding 2. Kalibrasie<\/td><td>2<\/td><td>5<\/td><td>2<\/td><td>20<\/td><td>1. Voorkomende instandhouding 2. Kalibrasie<\/td><td>gebruiker<\/td><\/tr><tr><td>Filter verstop<\/td><td>Die siklus word in een fase gesluit totdat dit herstel en na &#039;n bystandtydperk weer begin word<\/td><td>1. Humidification frekwensie limiet alarm<\/td><td>6<\/td><td>5<\/td><td>2<\/td><td>60<\/td><td>1. Voorkomende instandhouding<\/td><td>2<\/td><td>5<\/td><td>2<\/td><td>20<\/td><td>1. Voorkomende instandhouding<\/td><td>gebruiker<\/td><\/tr><tr><td rowspan=\"2\">2<\/td><td rowspan=\"2\">Te veel stoominspuiting<\/td><td>Foutiewe klep<\/td><td>Oormatige stoominspuiting, nat kartonne (sorteer)<\/td><td>1. Binnehuise hoogspanningsalarm 2. Einde van proses<\/td><td>6<\/td><td>5<\/td><td>4<\/td><td>120<\/td><td>1. Voorkomende instandhouding<\/td><td>2<\/td><td>5<\/td><td>4<\/td><td>40<\/td><td>1. Voorkomende instandhouding<\/td><td>gebruiker<\/td><\/tr><tr><td>Pressure transmitter\/humidity sensor failure<\/td><td>Oormatige stoominspuiting, nat kartonne (sorteer)<\/td><td>1. Oortollige druksensor 2. Alarm wanneer drukverskil limiet oorskry<\/td><td>6<\/td><td>5<\/td><td>2<\/td><td>60<\/td><td>1. Voorkomende instandhouding 2. Kalibrasie<\/td><td>2<\/td><td>5<\/td><td>2<\/td><td>20<\/td><td>1. Voorkomende instandhouding 2. Kalibrasie<\/td><td>gebruiker<\/td><\/tr><tr><td>3<\/td><td>Temperatuur is te hoog<\/td><td>Temperatuursensor mislukking<\/td><td>Impak op produkfunksies (rangorde)<\/td><td>1. Oortollige druksensor 2. Alarm wanneer drukverskil limiet oorskry<\/td><td>6<\/td><td>4<\/td><td>2<\/td><td>48<\/td><td>1. Voorkomende instandhouding 2. Kalibrasie<\/td><td>2<\/td><td>4<\/td><td>2<\/td><td>16<\/td><td>1. Voorkomende instandhouding 2. Kalibrasie<\/td><td>gebruiker<\/td><\/tr><tr><td rowspan=\"3\">4<\/td><td rowspan=\"3\">Die bokstemperatuur is laer as die onderste grenswaarde<\/td><td>Warmwater sirkulasie pomp mislukking<\/td><td>Die siklus word in een fase gesluit totdat dit herstel en na &#039;n bystandtydperk weer begin word<\/td><td>1. Verhitting-uittelalarm 2. Sirkulasiewaterpompoorladingalarm 3. Outomatiese verhittingstydkompensasie<\/td><td>6<\/td><td>3<\/td><td>2<\/td><td>36<\/td><td>1. Voorkomende instandhouding<\/td><td>2<\/td><td>4<\/td><td>2<\/td><td>16<\/td><td>1. Voorkomende instandhouding<\/td><td>gebruiker<\/td><\/tr><tr><td>Elektriese verwarmingsbuis mislukking<\/td><td>Die siklus word in een fase gesluit totdat dit herstel en na &#039;n bystandtydperk weer begin word<\/td><td>1. Verhitting time-out alarm 2. Outomatiese verwarming tyd kompensasie<\/td><td>6<\/td><td>3<\/td><td>3<\/td><td>54<\/td><td>1. Voorkomende instandhouding<\/td><td>2<\/td><td>3<\/td><td>3<\/td><td>18<\/td><td>1. Voorkomende instandhouding<\/td><td>gebruiker<\/td><\/tr><tr><td>Temperatuursensor mislukking<\/td><td>Beïnvloed produksteriliteit (hersterilisasie)<\/td><td>1. Verhitting-uittelalarm 2. Sirkulasiewaterpompoorladingsalarm<\/td><td>6<\/td><td>5<\/td><td>2<\/td><td>60<\/td><td>1. Voorkomende instandhouding 2. Kalibrasie<\/td><td>2<\/td><td>5<\/td><td>2<\/td><td>20<\/td><td>1. Voorkomende instandhouding 2. Kalibrasie<\/td><td>gebruiker<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><tbody><tr><td colspan=\"16\">Humidifikasie-verblyffase (Gebalanseerde humiditeit)<\/td><\/tr><tr><td rowspan=\"2\">Reeksnommer<\/td><td colspan=\"3\">Potensieel riskante inhoud<\/td><td colspan=\"5\">Risikobepaling onder bestaande prosestoestande<\/td><td colspan=\"5\">Risikobepaling van die resultate nadat maatreëls geneem is<\/td><td rowspan=\"2\">Aanbevole aksies<\/td><td rowspan=\"2\">Verantwoordelikhede en huidige status<\/td><\/tr><tr><td>Fout naam<\/td><td>Oorsaak<\/td><td>Mislukking impak<\/td><td>Beheer nou<\/td><td>gebeurtenis<\/td><td>Erns<\/td><td>ondersoek<\/td><td>Risikoprioritisering<\/td><td>Neem aksie<\/td><td>gebeurtenis<\/td><td>Erns<\/td><td>ondersoek<\/td><td>Risikoprioritisering<\/td><\/tr><tr><td>1<\/td><td>Gebrek aan tyd<\/td><td>tyd uit<\/td><td>Beïnvloed produksteriliteit (hersterilisasie)<\/td><td>1. Outomatiese siklus inspeksie<\/td><td>2<\/td><td>5<\/td><td>2<\/td><td>20<\/td><td>1. Voorkomende instandhouding<\/td><td>1<\/td><td>5<\/td><td>2<\/td><td>10<\/td><td>1. Voorkomende instandhouding<\/td><td>gebruiker<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><tbody><tr><td colspan=\"16\">Stikstofkussingstadium (Vul die kamer met inerte gas om die suurstof te verdun)<\/td><\/tr><tr><td rowspan=\"2\">Reeksnommer<\/td><td colspan=\"3\">Potensieel riskante inhoud<\/td><td colspan=\"5\">Risikobepaling onder bestaande prosestoestande<\/td><td colspan=\"5\">Risikobepaling van die resultate nadat maatreëls geneem is<\/td><td rowspan=\"2\">Aanbevole aksies<\/td><td rowspan=\"2\">Verantwoordelikhede en huidige status<\/td><\/tr><tr><td>Fout naam<\/td><td>Oorsaak<\/td><td>Mislukking impak<\/td><td>Beheer nou<\/td><td>gebeurtenis<\/td><td>Erns<\/td><td>ondersoek<\/td><td>Risikoprioritisering<\/td><td>Neem aksie<\/td><td>gebeurtenis<\/td><td>Erns<\/td><td>ondersoek<\/td><td>Risikoprioritisering<\/td><\/tr><tr><td rowspan=\"3\">1<\/td><td rowspan=\"3\">Daar kom nie genoeg stikstof in die kas nie<\/td><td>Gebrek aan stikstof<\/td><td>Die siklus word in een fase gesluit totdat dit herstel en na &#039;n bystandtydperk weer begin word<\/td><td>1. Gaan N2-druk na voordat die siklus begin word 2. Alarm wanneer N2-druk laer as die limiet is<\/td><td>3<\/td><td>3<\/td><td>2<\/td><td>18<\/td><td><\/td><td><\/td><td><\/td><td><\/td><td>0<\/td><td><\/td><td><\/td><\/tr><tr><td>Klep mislukking<\/td><td>Die siklus word in een fase gesluit totdat dit herstel en na &#039;n bystandtydperk weer begin word<\/td><td>geen<\/td><td>6<\/td><td>3<\/td><td>3<\/td><td>54<\/td><td>1. Voorkomende instandhouding<\/td><td>2<\/td><td>3<\/td><td>3<\/td><td>18<\/td><td>gebruiker<\/td><td>1. Voorkomende instandhouding<\/td><\/tr><tr><td>Druksensor mislukking<\/td><td>Vlambare Sone Gevaar<\/td><td>1. Oortollige druksensor 2. Alarm wanneer drukverskil limiet oorskry<\/td><td>6<\/td><td>3<\/td><td>2<\/td><td>36<\/td><td>1. Voorkomende instandhouding<\/td><td>2<\/td><td>3<\/td><td>2<\/td><td>12<\/td><td>gebruiker<\/td><td>1. Voorkomende instandhouding<\/td><\/tr><tr><td rowspan=\"2\">2<\/td><td rowspan=\"2\">Te veel stikstof in die kas ingespuit<\/td><td>Foutiewe klep<\/td><td>EO-konsentrasie is laer as die gevalideerde waarde, want tydens EO-inspuiting, indien dit deur druk (hersterilisasie) beheer word, word addisionele N2 ingespuit<\/td><td>1. Binnehuise hoogspanningsalarm 2. Einde van proses<\/td><td>6<\/td><td>5<\/td><td>4<\/td><td>120<\/td><td>1. Voorkomende instandhouding<\/td><td>2<\/td><td>5<\/td><td>4<\/td><td>40<\/td><td>gebruiker<\/td><td>1. Voorkomende instandhouding<\/td><\/tr><tr><td>Druksender mislukking<\/td><td>Te veel EO gas ingespuit. Hoë EO-residu. (Verleng ontgassingstyd)<\/td><td>1. Oortollige druksensor 2. Alarm wanneer drukverskil limiet oorskry<\/td><td>6<\/td><td>5<\/td><td>2<\/td><td>60<\/td><td>1. Voorkomende instandhouding 2. Kalibrasie<\/td><td>2<\/td><td>5<\/td><td>2<\/td><td>20<\/td><td>gebruiker<\/td><td>1. Voorkomende instandhouding 2. Kalibrasie<\/td><\/tr><tr><td>3<\/td><td>Die temperatuur binne die kas oorskry die boonste limiet<\/td><td>Temperatuursensor mislukking<\/td><td>Impak op produkfunksie (sortering)<\/td><td>1. Oortollige druksensor 2. Alarm wanneer drukverskil limiet oorskry<\/td><td>6<\/td><td>4<\/td><td>2<\/td><td>48<\/td><td>1. Voorkomende instandhouding 2. Kalibrasie<\/td><td>2<\/td><td>4<\/td><td>2<\/td><td>16<\/td><td>gebruiker<\/td><td>1. Voorkomende instandhouding 2. Kalibrasie<\/td><\/tr><tr><td rowspan=\"4\">4<\/td><td rowspan=\"4\">Die bokstemperatuur is laer as die onderste grenswaarde<\/td><td>Warmwater sirkulasie pomp mislukking<\/td><td>Die siklus word in &#039;n stadium gesluit totdat dit herstel word en na &#039;n bystandtydperk weer begin word. Groepe wat die gekwalifiseerde siklus oorskry het, kan weer gesteriliseer word.<\/td><td>1. Verhitting-uittelalarm 2. Sirkulasiewaterpompoorladingalarm 3. Outomatiese verhittingstydkompensasie<\/td><td>6<\/td><td>3<\/td><td>2<\/td><td>36<\/td><td>1. Voorkomende instandhouding<\/td><td>2<\/td><td>3<\/td><td>2<\/td><td>12<\/td><td>gebruiker<\/td><td>1. Voorkomende instandhouding<\/td><\/tr><tr><td>Elektriese verwarmingsbuis mislukking<\/td><td>Die siklus word in &#039;n stadium gesluit totdat dit herstel word en na &#039;n bystandtydperk weer begin word. Groepe wat die gekwalifiseerde siklus oorskry het, kan weer gesteriliseer word.<\/td><td>1. Verhitting-uittelalarm 2. Sirkulasiewaterpompoorladingalarm 3. Outomatiese verhittingstydkompensasie<\/td><td>6<\/td><td>3<\/td><td>3<\/td><td>54<\/td><td>1. Voorkomende instandhouding<\/td><td>2<\/td><td>3<\/td><td>3<\/td><td>18<\/td><td>gebruiker<\/td><td>1. Voorkomende instandhouding<\/td><\/tr><tr><td>Temperatuursensor mislukking<\/td><td>Beïnvloed produksteriliteit (hersterilisasie)<\/td><td>1. Oortollige temperatuursensor 2. Temperatuurverskil oorskry limietalarm<\/td><td>6<\/td><td>5<\/td><td>2<\/td><td>60<\/td><td>1. Voorkomende instandhouding 2. Kalibrasie<\/td><td>2<\/td><td>5<\/td><td>2<\/td><td>20<\/td><td>gebruiker<\/td><td>1. Voorkomende instandhouding 2. Kalibrasie<\/td><\/tr><tr><td>Lae vergasser temperatuur<\/td><td>Beïnvloed produksteriliteit (hersterilisasie)<\/td><td>1. Alarm wanneer die vergasser temperatuur laer is as die limiet 2. Outomatiese verwarming tyd kompensasie<\/td><td>6<\/td><td>4<\/td><td>2<\/td><td>48<\/td><td>1. Voorkomende instandhouding 2. Kalibrasie<\/td><td>2<\/td><td>4<\/td><td>2<\/td><td>16<\/td><td>gebruiker<\/td><td>1. Voorkomende instandhouding 2. Kalibrasie<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><tbody><tr><td colspan=\"16\">EO-inspuitingstadium (vul die kas met EO-gas)<\/td><\/tr><tr><td rowspan=\"2\">Reeksnommer<\/td><td colspan=\"3\">Potensieel riskante inhoud<\/td><td colspan=\"5\">Risikobepaling onder bestaande prosestoestande<\/td><td colspan=\"5\">Risikobepaling van die resultate nadat maatreëls geneem is<\/td><td rowspan=\"2\">Aanbevole aksies<\/td><td rowspan=\"2\">Verantwoordelikhede en huidige status<\/td><\/tr><tr><td>Fout naam<\/td><td>Oorsaak<\/td><td>Mislukking impak<\/td><td>Beheer nou<\/td><td>gebeurtenis<\/td><td>Erns<\/td><td>ondersoek<\/td><td>Risikoprioritisering<\/td><td>Neem aksie<\/td><td>gebeurtenis<\/td><td>Erns<\/td><td>ondersoek<\/td><td>Risikoprioritisering<\/td><\/tr><tr><td rowspan=\"4\">1<\/td><td rowspan=\"4\">Daar kom nie genoeg etileenoksied in die kas nie<\/td><td>EO ontbreek<\/td><td>Die siklus word in &#039;n stadium gesluit totdat dit herstel word en na &#039;n bystandtydperk weer begin word. Groepe wat die gekwalifiseerde siklus oorskry het, kan weer gesteriliseer word.<\/td><td>1.EO silindergat alarm 2.EO inspuiting timeout alarm<\/td><td>10<\/td><td>5<\/td><td>2<\/td><td>100<\/td><td>1. Operateursopleiding 2. EO gewigkontrole voor siklus begin<\/td><td>2<\/td><td>5<\/td><td>2<\/td><td>20<\/td><td>1. Operateursopleiding 2. EO gewigkontrole voor siklus begin<\/td><td>gebruiker<\/td><\/tr><tr><td>Foutiewe klep<\/td><td>Die siklus word in een fase gesluit totdat dit herstel en na &#039;n bystandtydperk weer begin word<\/td><td>1.EO inspuiting time-out alarm<\/td><td>6<\/td><td>5<\/td><td>2<\/td><td>60<\/td><td>1. Voorkomende instandhouding<\/td><td>6<\/td><td>5<\/td><td>2<\/td><td>60<\/td><td>1. Voorkomende instandhouding<\/td><td>gebruiker<\/td><\/tr><tr><td>EO pypleiding lekkasie<\/td><td>Groepe wat die kwalifikasietydperk oorskry, kan weer gesteriliseer word<\/td><td>geen<\/td><td>6<\/td><td>5<\/td><td>3<\/td><td>90<\/td><td>1. Voorkomende instandhouding 2. LEL EO detector alarm<\/td><td>2<\/td><td>5<\/td><td>2<\/td><td>20<\/td><td>1. Voorkomende instandhouding 2. LEL EO detector alarm<\/td><td>gebruiker<\/td><\/tr><tr><td>Druksensor mislukking<\/td><td>EO-konsentrasie is laer as die valideringswaarde (hersterilisasie)<\/td><td>1. Oortollige druksensor 2. Alarm wanneer drukverskil limiet oorskry<\/td><td>6<\/td><td>5<\/td><td>2<\/td><td>60<\/td><td>1. Voorkomende instandhouding 2. Kalibrasie<\/td><td>2<\/td><td>5<\/td><td>2<\/td><td>20<\/td><td>1. Voorkomende instandhouding 2. Kalibrasie<\/td><td>gebruiker<\/td><\/tr><tr><td rowspan=\"2\">2<\/td><td rowspan=\"2\">Vloeibare EO kom die kas binne<\/td><td>Lae vergasser temperatuur<\/td><td>Die siklus word in een fase gesluit totdat dit herstel en na &#039;n bystandtydperk weer begin word<\/td><td>1. Die vergasser temperatuur is laer as die limiet alarm<\/td><td>6<\/td><td>4<\/td><td>2<\/td><td>48<\/td><td>1. Voorkomende instandhouding<\/td><td>2<\/td><td>4<\/td><td>2<\/td><td>16<\/td><td>1. Voorkomende instandhouding<\/td><td>gebruiker<\/td><\/tr><tr><td>Nie genoeg water in die vergasser nie as gevolg van &#039;n foutiewe klep<\/td><td>Die siklus word in een fase gesluit totdat dit herstel en na &#039;n bystandtydperk weer begin word<\/td><td>1. Die vergasser se watervlak is laer as die limietalarm<\/td><td>6<\/td><td>4<\/td><td>2<\/td><td>48<\/td><td>1. Voorkomende instandhouding<\/td><td>2<\/td><td>4<\/td><td>2<\/td><td>16<\/td><td>1. Voorkomende instandhouding<\/td><td>gebruiker<\/td><\/tr><tr><td rowspan=\"2\">3<\/td><td rowspan=\"2\">Te veel etileenoksied insette in die kas<\/td><td>Foutiewe klep<\/td><td>Langer kwarantyn, wat bykomende toetse vereis<\/td><td>1. Binnenshuise hoogspanning alarm<\/td><td>6<\/td><td>3<\/td><td>3<\/td><td>54<\/td><td>1. Voorkomende instandhouding 2. EO residuele inspeksie<\/td><td>2<\/td><td>3<\/td><td>3<\/td><td>18<\/td><td>1. Voorkomende instandhouding 2. EO residuele inspeksie<\/td><td>gebruiker<\/td><\/tr><tr><td>Druksensor mislukking<\/td><td>Langer kwarantyn, wat bykomende toetse vereis<\/td><td>1. Oortollige druksensor 2. Alarm wanneer drukverskil limiet oorskry<\/td><td>6<\/td><td>3<\/td><td>2<\/td><td>36<\/td><td>1. Voorkomende instandhouding 2. Kalibrasie<\/td><td>2<\/td><td>3<\/td><td>2<\/td><td>12<\/td><td>1. Voorkomende instandhouding 2. Kalibrasie<\/td><td>gebruiker<\/td><\/tr><tr><td>4<\/td><td>Die temperatuur binne die kas oorskry die boonste limiet<\/td><td>Temperatuursensor mislukking<\/td><td>Impak op produkfunksie (sortering)<\/td><td>1. Oortollige temperatuur sensor 2. Kamer hoë temperatuur alarm 3. Temperatuur verskil oorskry limiet alarm<\/td><td>6<\/td><td>4<\/td><td>2<\/td><td>48<\/td><td>1. Voorkomende instandhouding 2. Kalibrasie<\/td><td>2<\/td><td>4<\/td><td>2<\/td><td>16<\/td><td>1. Voorkomende instandhouding 2. Kalibrasie<\/td><td>gebruiker<\/td><\/tr><tr><td rowspan=\"4\">5<\/td><td rowspan=\"4\">Die bokstemperatuur is laer as die onderste grenswaarde<\/td><td>Warmwater sirkulasie pomp mislukking<\/td><td>Die siklus word in &#039;n stadium gesluit totdat dit herstel word en na &#039;n bystandtydperk weer begin word. Groepe wat die gekwalifiseerde siklus oorskry het, kan weer gesteriliseer word.<\/td><td>1. Verhitting-uittelalarm 2. Sirkulasiewaterpompoorladingalarm 3. Outomatiese verhittingstydkompensasie<\/td><td>6<\/td><td>3<\/td><td>2<\/td><td>36<\/td><td>1. Voorkomende instandhouding<\/td><td>2<\/td><td>3<\/td><td>2<\/td><td>12<\/td><td>1. Voorkomende instandhouding<\/td><td>gebruiker<\/td><\/tr><tr><td>Elektriese verwarmingsbuis mislukking<\/td><td>Die siklus word in &#039;n stadium gesluit totdat dit herstel word en na &#039;n bystandtydperk weer begin word. Groepe wat die gekwalifiseerde siklus oorskry het, kan weer gesteriliseer word.<\/td><td>1. Verhitting time-out alarm 2. Outomatiese verwarming tyd kompensasie<\/td><td>6<\/td><td>3<\/td><td>3<\/td><td>54<\/td><td>1. Voorkomende instandhouding<\/td><td>2<\/td><td>3<\/td><td>3<\/td><td>18<\/td><td>1. Voorkomende instandhouding<\/td><td>gebruiker<\/td><\/tr><tr><td>Temperatuursensor mislukking<\/td><td>Beïnvloed produksteriliteit (hersterilisasie)<\/td><td>1. Oortollige temperatuursensor 2. Temperatuurverskil oorskry limietalarm<\/td><td>6<\/td><td>5<\/td><td>2<\/td><td>60<\/td><td>1. Voorkomende instandhouding 2. Kalibrasie<\/td><td>2<\/td><td>5<\/td><td>2<\/td><td>20<\/td><td>1. Voorkomende instandhouding 2. Kalibrasie<\/td><td>gebruiker<\/td><\/tr><tr><td>Lae vergasser temperatuur<\/td><td>Beïnvloed produksteriliteit (hersterilisasie)<\/td><td>1. Alarm wanneer die vergasser temperatuur laer is as die limiet 2. Outomatiese verwarming tyd kompensasie<\/td><td>6<\/td><td>4<\/td><td>2<\/td><td>48<\/td><td>1. Voorkomende instandhouding<\/td><td>2<\/td><td>4<\/td><td>2<\/td><td>16<\/td><td>1. Voorkomende instandhouding<\/td><td>gebruiker<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><tbody><tr><td colspan=\"16\">Stikstofkapstadium (Voeg N2 by om EO te bedek)<\/td><\/tr><tr><td rowspan=\"2\">Reeksnommer<\/td><td colspan=\"3\">Potensieel riskante inhoud<\/td><td colspan=\"5\">Risikobepaling onder bestaande prosestoestande<\/td><td colspan=\"5\">Risikobepaling van die resultate nadat maatreëls geneem is<\/td><td rowspan=\"2\">Aanbevole aksies<\/td><td rowspan=\"2\">Verantwoordelikhede en huidige status<\/td><\/tr><tr><td>Fout naam<\/td><td>Oorsaak<\/td><td>Mislukking impak<\/td><td>Beheer nou<\/td><td>gebeurtenis<\/td><td>Erns<\/td><td>ondersoek<\/td><td>Risikoprioritisering<\/td><td>Neem aksie<\/td><td>gebeurtenis<\/td><td>Erns<\/td><td>ondersoek<\/td><td>Risikoprioritisering<\/td><\/tr><tr><td rowspan=\"3\">1<\/td><td rowspan=\"3\">Daar kom nie genoeg stikstof in die kas nie<\/td><td>Gebrek aan stikstof<\/td><td>Die siklus word in een fase gesluit totdat dit herstel en na &#039;n bystandtydperk weer begin word<\/td><td>1. Gaan N2-druk na voordat die siklus begin word 2. Alarm wanneer N2-druk laer as die limiet is<\/td><td>3<\/td><td>3<\/td><td>2<\/td><td>18<\/td><td><\/td><td><\/td><td><\/td><td><\/td><td><\/td><td>N\/A<\/td><td><\/td><\/tr><tr><td>Klep mislukking<\/td><td>Die siklus word in een fase gesluit totdat dit herstel en na &#039;n bystandtydperk weer begin word<\/td><td>geen<\/td><td>6<\/td><td>3<\/td><td>3<\/td><td>54<\/td><td>1. Voorkomende instandhouding<\/td><td>2<\/td><td>3<\/td><td>3<\/td><td>18<\/td><td>1. Voorkomende instandhouding<\/td><td>gebruiker<\/td><\/tr><tr><td>Druksensor mislukking<\/td><td>Vlambare Sone Gevaar<\/td><td>1. Oortollige druksensor 2. Alarm wanneer drukverskil limiet oorskry<\/td><td>6<\/td><td>3<\/td><td>2<\/td><td>36<\/td><td>1. Voorkomende instandhouding<\/td><td>2<\/td><td>3<\/td><td>2<\/td><td>12<\/td><td>1. Voorkomende instandhouding<\/td><td>gebruiker<\/td><\/tr><tr><td>2<\/td><td>Te veel stikstof in die kas ingespuit<\/td><td>Foutiewe klep<\/td><td>Die kajuit is onder positiewe druk. Hierdie siklus sal eindig.<\/td><td>1. Binnehuise hoogspanningsalarm 2. Einde van proses<\/td><td>6<\/td><td>5<\/td><td>4<\/td><td>120<\/td><td>1. Voorkomende instandhouding<\/td><td>2<\/td><td>5<\/td><td>4<\/td><td>40<\/td><td>1. Voorkomende instandhouding<\/td><td>gebruiker<\/td><\/tr><tr><td>3<\/td><td>Die temperatuur binne die kas oorskry die boonste limiet<\/td><td>Temperatuursensor mislukking<\/td><td>Beïnvloed produksteriliteit (hersterilisasie)<\/td><td>1. Oortollige temperatuur sensor 2. Kamer hoë temperatuur alarm 3. Temperatuur verskil oorskry limiet alarm<\/td><td>6<\/td><td>4<\/td><td>2<\/td><td>48<\/td><td>1. Voorkomende instandhouding 2. Kalibrasie<\/td><td>2<\/td><td>4<\/td><td>2<\/td><td>16<\/td><td>1. Voorkomende instandhouding 2. Kalibrasie<\/td><td>gebruiker<\/td><\/tr><tr><td rowspan=\"4\">4<\/td><td rowspan=\"4\">Die bokstemperatuur is laer as die onderste grenswaarde<\/td><td>Warmwater sirkulasie pomp mislukking<\/td><td>Die siklus word in &#039;n stadium gesluit totdat dit herstel word en na &#039;n bystandtydperk weer begin word. Groepe wat die gekwalifiseerde siklus oorskry het, kan weer gesteriliseer word.<\/td><td>1. Verhitting-uittelalarm 2. Sirkulasiewaterpompoorladingalarm 3. Outomatiese verhittingstydkompensasie<\/td><td>6<\/td><td>3<\/td><td>2<\/td><td>36<\/td><td>1. Voorkomende instandhouding<\/td><td>2<\/td><td>3<\/td><td>2<\/td><td>12<\/td><td>1. Voorkomende instandhouding<\/td><td>gebruiker<\/td><\/tr><tr><td>Elektriese verwarmingsbuis mislukking<\/td><td>Die siklus word in &#039;n stadium gesluit totdat dit herstel word en na &#039;n bystandtydperk weer begin word. Groepe wat die gekwalifiseerde siklus oorskry het, kan weer gesteriliseer word.<\/td><td>1. Verhitting time-out alarm 2. Outomatiese verwarming tyd kompensasie<\/td><td>6<\/td><td>3<\/td><td>3<\/td><td>54<\/td><td>1. Voorkomende instandhouding<\/td><td>2<\/td><td>3<\/td><td>3<\/td><td>18<\/td><td>1. Voorkomende instandhouding<\/td><td>gebruiker<\/td><\/tr><tr><td>Temperatuursensor mislukking<\/td><td>Beïnvloed produksteriliteit (hersterilisasie)<\/td><td>1. Oortollige temperatuursensor 2. Temperatuurverskil oorskry limietalarm<\/td><td>6<\/td><td>5<\/td><td>2<\/td><td>60<\/td><td>1. Voorkomende instandhouding 2. Kalibrasie<\/td><td>2<\/td><td>5<\/td><td>2<\/td><td>20<\/td><td>1. Voorkomende instandhouding 2. Kalibrasie<\/td><td>gebruiker<\/td><\/tr><tr><td>Lae vergasser temperatuur<\/td><td>Beïnvloed produksteriliteit (hersterilisasie)<\/td><td>1. Alarm wanneer die vergasser temperatuur laer is as die limiet 2. Outomatiese verwarming tyd kompensasie<\/td><td>6<\/td><td>4<\/td><td>2<\/td><td>48<\/td><td>1. Voorkomende instandhouding<\/td><td>2<\/td><td>4<\/td><td>2<\/td><td>16<\/td><td>1. Voorkomende instandhouding<\/td><td>gebruiker<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><tbody><tr><td colspan=\"16\">EO blootstelling stadium (ontsmet die produk)<\/td><\/tr><tr><td rowspan=\"2\">Reeksnommer<\/td><td colspan=\"3\">Potensieel riskante inhoud<\/td><td colspan=\"5\">Risikobepaling onder bestaande prosestoestande<\/td><td colspan=\"5\">Risikobepaling van die resultate nadat maatreëls geneem is<\/td><td rowspan=\"2\">Aanbevole aksies<\/td><td rowspan=\"2\">Verantwoordelikhede en huidige status<\/td><\/tr><tr><td>Fout naam<\/td><td>Oorsaak<\/td><td>Mislukking impak<\/td><td>Beheer nou<\/td><td>gebeurtenis<\/td><td>Erns<\/td><td>ondersoek<\/td><td>Risikoprioritisering<\/td><td>Neem aksie<\/td><td>gebeurtenis<\/td><td>Erns<\/td><td>ondersoek<\/td><td>Risikoprioritisering<\/td><\/tr><tr><td>1<\/td><td>Gebrek aan tyd<\/td><td>Programmeringsfoute<\/td><td>Herhaal sterilisasie<\/td><td>1. Outomatiese siklus inspeksie<\/td><td>2<\/td><td>5<\/td><td>2<\/td><td>20<\/td><td>1. Voorkomende instandhouding<\/td><td>1<\/td><td>5<\/td><td>2<\/td><td>10<\/td><td>1. Voorkomende instandhouding<\/td><td>gebruiker<\/td><\/tr><tr><td rowspan=\"3\">2<\/td><td rowspan=\"3\">Die bokstemperatuur is laer as die onderste limiet t<\/td><td>Warmwater sirkulasie pomp mislukking<\/td><td>Die siklus word in &#039;n stadium gesluit totdat dit herstel word en na &#039;n bystandtydperk weer begin word. Groepe wat die gekwalifiseerde siklus oorskry het, kan weer gesteriliseer word.<\/td><td>Verhitting-time-out 2. Sirkulasiewaterpomp-oorladingsalarm 3. Outomatiese verhittingstydkompensasie<\/td><td>6<\/td><td>3<\/td><td>2<\/td><td>36<\/td><td>1. Voorkomende instandhouding<\/td><td>2<\/td><td>3<\/td><td>2<\/td><td>12<\/td><td>1. Voorkomende instandhouding<\/td><td>gebruiker<\/td><\/tr><tr><td>Elektriese verwarmingsbuis mislukking<\/td><td>Die siklus word in een fase gesluit totdat dit hervat word en na &#039;n bystandtydperk weer begin word. Groepe wat die gekwalifiseerde siklus oorskry het, kan weer gesteriliseer word.<\/td><td>1. Verhitting time-out alarm 2. Outomatiese verwarming tyd kompensasie<\/td><td>6<\/td><td>3<\/td><td>3<\/td><td>54<\/td><td>1. Voorkomende instandhouding<\/td><td>2<\/td><td>3<\/td><td>3<\/td><td>18<\/td><td>1. Voorkomende instandhouding<\/td><td>gebruiker<\/td><\/tr><tr><td>Temperatuursensor mislukking<\/td><td>Beïnvloed produksteriliteit (hersterilisasie)<\/td><td>1. Oortollige temperatuursensor 2. Temperatuurverskil oorskry limietalarm<\/td><td>6<\/td><td>5<\/td><td>2<\/td><td>60<\/td><td>1. Voorkomende instandhouding 2. Kalibrasie<\/td><td>2<\/td><td>5<\/td><td>2<\/td><td>20<\/td><td>1. Voorkomende instandhouding 2. Kalibrasie<\/td><td>gebruiker<\/td><\/tr><tr><td>3<\/td><td>Die temperatuur binne die kas oorskry die boonste limiet<\/td><td>Temperatuursensor mislukking<\/td><td>Beïnvloed produksteriliteit (hersterilisasie)<\/td><td>1. Oortollige temperatuursensor 2. Kamer hoë temperatuur alarm 3. Temperatuur alarm<\/td><td>6<\/td><td>4<\/td><td>2<\/td><td>48<\/td><td>1. Voorkomende instandhouding 2. Kalibrasie<\/td><td>2<\/td><td>4<\/td><td>2<\/td><td>16<\/td><td>1. Voorkomende instandhouding 2. Kalibrasie<\/td><td>gebruiker<\/td><\/tr><tr><td rowspan=\"2\">4<\/td><td rowspan=\"2\">Kry nie &#039;n voldoende homogene EO-mengsel nie<\/td><td>Sirkulasiewaaier mislukking<\/td><td>Beïnvloed produksteriliteit (hersterilisasie)<\/td><td>1. Laespoed alarm<\/td><td>6<\/td><td>5<\/td><td>3<\/td><td>90<\/td><td>1. Voorkomende instandhouding<\/td><td>2<\/td><td>5<\/td><td>3<\/td><td>30<\/td><td>1. Voorkomende instandhouding<\/td><td>gebruiker<\/td><\/tr><tr><td>Produkposisionering baie naby aan die holmuur<\/td><td>Beïnvloed produksteriliteit (hersterilisasie)<\/td><td>1.Guardrail word gebruik om te verhoed dat die produk met die holmuur in aanraking kom<\/td><td>2<\/td><td>5<\/td><td>3<\/td><td>30<\/td><td><\/td><td><\/td><td><\/td><td><\/td><td>0<\/td><td>N\/A<\/td><td><\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><tbody><tr><td colspan=\"16\">EO Removal Phase(Create vacuum\/remove sterilization gas)<\/td><\/tr><tr><td rowspan=\"2\">Reeksnommer<\/td><td colspan=\"3\">Potensieel riskante inhoud<\/td><td colspan=\"5\">Risikobepaling onder bestaande prosestoestande<\/td><td colspan=\"5\">Risikobepaling van die resultate nadat maatreëls geneem is<\/td><td rowspan=\"2\">Aanbevole aksies<\/td><td rowspan=\"2\">Verantwoordelikhede en huidige status<\/td><\/tr><tr><td>Fout naam<\/td><td>Oorsaak<\/td><td>Mislukking impak<\/td><td>Beheer nou<\/td><td>gebeurtenis<\/td><td>Erns<\/td><td>ondersoek<\/td><td>Risikoprioritisering<\/td><td>Neem aksie<\/td><td>gebeurtenis<\/td><td>Erns<\/td><td>ondersoek<\/td><td>Risikoprioritisering<\/td><\/tr><tr><td rowspan=\"3\">1<\/td><td rowspan=\"3\">Maak nie genoeg gas skoon nie<\/td><td>Ondoeltreffende vakuumpomp<\/td><td>Die siklus word in een fase gesluit totdat dit herstel en na &#039;n bystandtydperk weer begin word<\/td><td>1. EO-verwydering uittelalarm 2. Vakuumpompoorladingsalarm 3. Bespeur watervloei outomaties en skakel die waterlose pomp af<\/td><td>6<\/td><td>3<\/td><td>2<\/td><td>36<\/td><td>1. Voorkomende instandhouding<\/td><td>2<\/td><td>3<\/td><td>2<\/td><td>12<\/td><td>1. Voorkomende instandhouding<\/td><td>gebruiker<\/td><\/tr><tr><td>Foutiewe klep<\/td><td>Die siklus word in een fase gesluit totdat dit herstel en na &#039;n bystandtydperk weer begin word<\/td><td>1.EO verwydering time-out alarm 2. Vakuum pomp oorlading alarm<\/td><td>6<\/td><td>3<\/td><td>2<\/td><td>36<\/td><td>1. Voorkomende instandhouding<\/td><td>2<\/td><td>3<\/td><td>2<\/td><td>12<\/td><td>1. Voorkomende instandhouding<\/td><td>gebruiker<\/td><\/tr><tr><td>Druksensor mislukking<\/td><td>Langer isolasietyd en bykomende toetsing word vereis weens minder EO-gas wat verwyder word<\/td><td>1. Oortollige druksensor 2. Alarm wanneer drukverskil limiet oorskry<\/td><td>6<\/td><td>3<\/td><td>2<\/td><td>36<\/td><td>1. Voorkomende instandhouding 2. Kalibrasie<\/td><td>2<\/td><td>3<\/td><td>2<\/td><td>12<\/td><td>1. Voorkomende instandhouding 2. Kalibrasie<\/td><td>gebruiker<\/td><\/tr><tr><td>2<\/td><td>Rug te veel gas uit<\/td><td>Druksensor mislukking<\/td><td>Product and\/or packaging damage (classification)<\/td><td>1. Oortollige druksensor 2. Alarm wanneer drukverskil limiet oorskry<\/td><td>6<\/td><td>4<\/td><td>2<\/td><td>48<\/td><td>1. Voorkomende instandhouding 2. Kalibrasie<\/td><td>2<\/td><td>4<\/td><td>2<\/td><td>16<\/td><td>1. Voorkomende instandhouding 2. Kalibrasie<\/td><td>gebruiker<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><tbody><tr><td colspan=\"16\">Stikstofspoelstadium (Verseker dat die binnenshuise omgewing nie vlambaar is nie)<\/td><\/tr><tr><td rowspan=\"2\">Reeksnommer<\/td><td colspan=\"3\">Potensieel riskante inhoud<\/td><td colspan=\"5\">Risikobepaling onder bestaande prosestoestande<\/td><td colspan=\"5\">Risikobepaling van die resultate nadat maatreëls geneem is<\/td><td rowspan=\"2\">Aanbevole aksies<\/td><td rowspan=\"2\">Verantwoordelikhede en huidige status<\/td><\/tr><tr><td>Fout naam<\/td><td>Oorsaak<\/td><td>Mislukking impak<\/td><td>Beheer nou<\/td><td>gebeurtenis<\/td><td>Erns<\/td><td>ondersoek<\/td><td>Risikoprioritisering<\/td><td>Neem aksie<\/td><td>gebeurtenis<\/td><td>Erns<\/td><td>ondersoek<\/td><td>Risikoprioritisering<\/td><\/tr><tr><td rowspan=\"4\">1<\/td><td rowspan=\"4\">Nie genoeg stikstof kom die kamer binne nie<\/td><td>Gebrek aan stikstof<\/td><td>Die siklus word in een fase gesluit totdat dit herstel en na &#039;n bystandtydperk weer begin word<\/td><td>1. Gaan N2-druk na voordat die siklus begin word 2. Alarm wanneer N2-druk laer as die limiet is<\/td><td>3<\/td><td>3<\/td><td>2<\/td><td>18<\/td><td><\/td><td><\/td><td><\/td><td><\/td><td><\/td><td>N\/A<\/td><td><\/td><\/tr><tr><td>Foutiewe klep<\/td><td>Die siklus word in een fase gesluit totdat dit herstel en na &#039;n bystandtydperk weer begin word<\/td><td>geen<\/td><td>6<\/td><td>3<\/td><td>3<\/td><td>54<\/td><td>1. Voorkomende instandhouding<\/td><td>2<\/td><td>3<\/td><td>3<\/td><td>18<\/td><td>1. Voorkomende instandhouding<\/td><td>gebruiker<\/td><\/tr><tr><td rowspan=\"2\">Druksensor mislukking<\/td><td>Vlambare Sone Gevaar<\/td><td>1. Oortollige druksensor 2. Alarm wanneer drukverskil limiet oorskry<\/td><td>6<\/td><td>3<\/td><td>2<\/td><td>36<\/td><td>1. Voorkomende instandhouding<\/td><td>2<\/td><td>3<\/td><td>2<\/td><td>12<\/td><td>1. Voorkomende instandhouding<\/td><td>gebruiker<\/td><\/tr><tr><td>Langer kwarantyne vereis bykomende toetse<\/td><td>1. Oortollige druksensor 2. Alarm wanneer drukverskil limiet oorskry<\/td><td>6<\/td><td>3<\/td><td>2<\/td><td>36<\/td><td>1. Voorkomende instandhouding<\/td><td>2<\/td><td>3<\/td><td>2<\/td><td>12<\/td><td>1. Voorkomende instandhouding<\/td><td>gebruiker<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><tbody><tr><td colspan=\"16\">Air cleaning stage(Create vacuum\/remove residual sterilization gas, eliminate residual EO)<\/td><\/tr><tr><td rowspan=\"2\">Reeksnommer<\/td><td colspan=\"3\">Potensieel riskante inhoud<\/td><td colspan=\"5\">Risikobepaling onder bestaande prosestoestande<\/td><td colspan=\"5\">Risikobepaling van die resultate nadat maatreëls geneem is<\/td><td rowspan=\"2\">Aanbevole aksies<\/td><td rowspan=\"2\">Verantwoordelikhede en huidige status<\/td><\/tr><tr><td>Fout naam<\/td><td>Oorsaak<\/td><td>Mislukking impak<\/td><td>Beheer nou<\/td><td>gebeurtenis<\/td><td>Erns<\/td><td>ondersoek<\/td><td>Risikoprioritisering<\/td><td>Neem aksie<\/td><td>gebeurtenis<\/td><td>Erns<\/td><td>ondersoek<\/td><td>Risikoprioritisering<\/td><\/tr><tr><td rowspan=\"3\">1<\/td><td rowspan=\"3\">Maak nie genoeg gas skoon nie<\/td><td>Ondoeltreffende vakuumpomp<\/td><td>Die siklus word in een fase gesluit totdat dit herstel en na &#039;n bystandtydperk weer begin word<\/td><td>1. EO-verwydering uittelalarm 2. Vakuumpompoorladingsalarm 3. Bespeur watervloei outomaties en skakel die waterlose pomp af<\/td><td>6<\/td><td>3<\/td><td>2<\/td><td>36<\/td><td>1. Voorkomende instandhouding<\/td><td>2<\/td><td>3<\/td><td>2<\/td><td>12<\/td><td>1. Voorkomende instandhouding<\/td><td>gebruiker<\/td><\/tr><tr><td>Foutiewe klep<\/td><td>Die siklus word in een fase gesluit totdat dit herstel en na &#039;n bystandtydperk weer begin word<\/td><td>1.EO verwydering time-out alarm 2. Vakuum pomp oorlading alarm<\/td><td>6<\/td><td>3<\/td><td>2<\/td><td>36<\/td><td>1. Voorkomende instandhouding<\/td><td>2<\/td><td>3<\/td><td>2<\/td><td>12<\/td><td>1. Voorkomende instandhouding<\/td><td>gebruiker<\/td><\/tr><tr><td>Druksensor mislukking<\/td><td>Langer isolasietyd en bykomende toetsing word vereis weens minder EO-gas wat verwyder word<\/td><td>1. Oortollige druksensor 2. Alarm wanneer drukverskil limiet oorskry<\/td><td>6<\/td><td>3<\/td><td>2<\/td><td>36<\/td><td>1. Voorkomende instandhouding 2. Kalibrasie<\/td><td>2<\/td><td>3<\/td><td>2<\/td><td>12<\/td><td>1. Voorkomende instandhouding 2. Kalibrasie<\/td><td>gebruiker<\/td><\/tr><tr><td>2<\/td><td>Rug te veel gas uit<\/td><td>Druksensor mislukking<\/td><td>Product and\/or packaging damage (classification)<\/td><td>1. Oortollige druksensor 2. Alarm wanneer drukverskil limiet oorskry<\/td><td>6<\/td><td>4<\/td><td>2<\/td><td>48<\/td><td>1. Voorkomende instandhouding 2. Kalibrasie<\/td><td>2<\/td><td>4<\/td><td>2<\/td><td>16<\/td><td>1. Voorkomende instandhouding 2. Kalibrasie<\/td><td>gebruiker<\/td><\/tr><tr><td rowspan=\"3\">3<\/td><td rowspan=\"3\">Onvoldoende lug in die kajuit<\/td><td>Foutiewe klep<\/td><td>Die siklus word in een fase gesluit totdat dit herstel en na &#039;n bystandtydperk weer begin word<\/td><td>1. Gasinspuitingstyd oor limietalarm<\/td><td>6<\/td><td>4<\/td><td>3<\/td><td>72<\/td><td>1. Voorkomende instandhouding<\/td><td>2<\/td><td>4<\/td><td>3<\/td><td>24<\/td><td>1. Voorkomende instandhouding<\/td><td>gebruiker<\/td><\/tr><tr><td>Filter verstop<\/td><td>Die siklus word in een fase gesluit totdat dit herstel en na &#039;n bystandtydperk weer begin word<\/td><td>1. Gasinspuitingstyd oor limietalarm<\/td><td>6<\/td><td>4<\/td><td>3<\/td><td>72<\/td><td>1. Voorkomende instandhouding<\/td><td>2<\/td><td>4<\/td><td>3<\/td><td>24<\/td><td>1. Voorkomende instandhouding<\/td><td>gebruiker<\/td><\/tr><tr><td>Druksensor mislukking<\/td><td>Langer kwarantyne vereis bykomende toetse<\/td><td>1. Oortollige druksensor 2. Alarm wanneer drukverskil limiet oorskry<\/td><td>6<\/td><td>3<\/td><td>2<\/td><td>36<\/td><td>1. Voorkomende instandhouding 2. Kalibrasie<\/td><td>2<\/td><td>4<\/td><td>2<\/td><td>16<\/td><td>1. Voorkomende instandhouding 2. Kalibrasie<\/td><td>gebruiker<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><tbody><tr><td colspan=\"16\">Verwydering stadium (Verwyder residu van die produk)<\/td><\/tr><tr><td rowspan=\"2\">Reeksnommer<\/td><td colspan=\"3\">Potensieel riskante inhoud<\/td><td colspan=\"5\">Risikobepaling onder bestaande prosestoestande<\/td><td colspan=\"5\">Risikobepaling van die resultate nadat maatreëls geneem is<\/td><td rowspan=\"2\">Aanbevole aksies<\/td><td rowspan=\"2\">Verantwoordelikhede en huidige status<\/td><\/tr><tr><td>Fout naam<\/td><td>Oorsaak<\/td><td>Mislukking impak<\/td><td>Beheer nou<\/td><td>gebeurtenis<\/td><td>Erns<\/td><td>ondersoek<\/td><td>Risikoprioritisering<\/td><td>Neem aksie<\/td><td>gebeurtenis<\/td><td>Erns<\/td><td>ondersoek<\/td><td>Risikoprioritisering<\/td><\/tr><tr><td>1<\/td><td>Belugtingstyd is minder as die gespesifiseerde tyd<\/td><td>Programmeringsfoute<\/td><td>Herhaal sterilisasie<\/td><td>1. Outomatiese siklus inspeksie<\/td><td>2<\/td><td>3<\/td><td>2<\/td><td>12<\/td><td>1. Herbegin jou rekenaar gereeld<\/td><td>1<\/td><td>3<\/td><td>2<\/td><td>6<\/td><td>1. Herbegin jou rekenaar gereeld<\/td><td>gebruiker<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"h-if-you-want-to-know-more-about-ethylene-oxide-sterilization\">AS JY MEER WIL WEET Oor Etileenoksiedsterilisasie<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Telefoon:<a href=\"https:\/\/wa.me\/8619975258603\">+8619975258603<\/a><\/p>\n\n\n\n<p class=\"wp-block-paragraph\">E-pos:<a href=\"mailto:hayley@hzbocon.com\">hayley@hzbocon.com<\/a><\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Plaaslike terrein: Kamer 1202, Caitong Zhongxin, Xiasha-distrik, Hangzhou-stad, Zhejiang-provinsie, China<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Webwerf:<a href=\"https:\/\/www.hzbocon.com\/\">hzbocon.com<\/a><a href=\"https:\/\/zjbocon.com\/\">&nbsp;zjbocon.com<\/a><\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><\/p>\n","protected":false},"excerpt":{"rendered":"<p>Start cycle phase(Select parameters\/sterilization recipe) Serial number Potentially risky content Risk assessment under existing process conditions Risk assessment of the [&hellip;]<\/p>\n","protected":false},"author":234312599,"featured_media":8473,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_uag_custom_page_level_css":"","site-sidebar-layout":"default","site-content-layout":"","ast-site-content-layout":"","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","ast-disable-related-posts":"","theme-transparent-header-meta":"","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"set","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"_jetpack_newsletter_access":"","_jetpack_dont_email_post_to_subs":false,"_jetpack_newsletter_tier_id":0,"_jetpack_memberships_contains_paywalled_content":false,"_jetpack_feature_clip_id":0,"_jetpack_memberships_contains_paid_content":false,"footnotes":"","jetpack_publicize_message":"","jetpack_publicize_feature_enabled":true,"jetpack_social_post_already_shared":false,"jetpack_social_options":{"image_generator_settings":{"template":"highway","enabled":false},"version":2},"jetpack_post_was_ever_published":false},"categories":[133124],"tags":[],"class_list":["post-2425","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-eto-sterilizer"],"yoast_head":"<!-- This site is optimized with the Yoast SEO Premium plugin v27.2 (Yoast SEO v28.0) - https:\/\/yoast.com\/product\/yoast-seo-premium-wordpress\/ -->\n<title>EO sterilisasie toerusting en proses kenmerkende patrone en effek analise - ETO STERILISEERDER<\/title>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \>\n<link rel=\"canonical\" href=\"https:\/\/zjbocon.com\/?p=2425\" \>\n<meta property=\"og:locale\" content=\"en_US\" \>\n<meta property=\"og:type\" content=\"article\" \>\n<meta property=\"og:title\" content=\"EO sterilization equipment and process characteristic patterns effect analysis\" \>\n<meta property=\"og:description\" content=\"Start cycle phase(Select parameters\>\n<meta property=\"og:url\" content=\"https:\/\/zjbocon.com\/?p=2425\" \>\n<meta property=\"og:site_name\" content=\"ETO STERILIZER\" \>\n<meta property=\"article:publisher\" content=\"https:\/\/www.facebook.com\/profile.php?id=100088482339878\" \>\n<meta property=\"article:author\" content=\"https:\/\/www.facebook.com\/profile.php?id=100088482339878\" \>\n<meta property=\"article:published_time\" content=\"2024-12-17T02:45:20+00:00\" \>\n<meta property=\"article:modified_time\" content=\"2026-02-09T01:58:51+00:00\" \>\n<meta property=\"og:image\" content=\"https:\/\/zjbocon.com\/wp-content\/uploads\/2025\/09\/ethylene-oxide-sterilization-68.webp\" \>\n\t<meta property=\"og:image:width\" content=\"384\" \>\n\t<meta property=\"og:image:height\" content=\"512\" \>\n\t<meta property=\"og:image:type\" content=\"image\/webp\" \>\n<meta name=\"author\" content=\"Bocon Technical Team\" \>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \>\n<meta name=\"twitter:creator\" content=\"@BoconAnd\" \>\n<meta name=\"twitter:site\" content=\"@BoconAnd\" \>\n<meta name=\"twitter:label1\" content=\"Written by\" \>\n\t<meta name=\"twitter:data1\" content=\"Bocon Technical Team\" \>\n\t<meta name=\"twitter:label2\" content=\"Est. reading time\" \>\n\t<meta name=\"twitter:data2\" content=\"23 minutes\" \>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\\\/\\\/zjbocon.com\\\/?p=2425#article\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/zjbocon.com\\\/?p=2425\"},\"author\":{\"name\":\"Bocon Technical Team\",\"@id\":\"https:\\\/\\\/zjbocon.com\\\/#\\\/schema\\\/person\\\/f12be028b8ae9843a4396dcc8012b425\"},\"headline\":\"EO sterilization equipment and process characteristic patterns and effect analysis\",\"datePublished\":\"2024-12-17T02:45:20+00:00\",\"dateModified\":\"2026-02-09T01:58:51+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/zjbocon.com\\\/?p=2425\"},\"wordCount\":3962,\"commentCount\":0,\"publisher\":{\"@id\":\"https:\\\/\\\/zjbocon.com\\\/#organization\"},\"image\":{\"@id\":\"https:\\\/\\\/zjbocon.com\\\/?p=2425#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/zjbocon.com\\\/wp-content\\\/uploads\\\/2025\\\/09\\\/ethylene-oxide-sterilization-68.webp\",\"articleSection\":[\"ETO STERILIZER\"],\"inLanguage\":\"af\",\"potentialAction\":[{\"@type\":\"CommentAction\",\"name\":\"Comment\",\"target\":[\"https:\\\/\\\/zjbocon.com\\\/?p=2425#respond\"]}]},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/zjbocon.com\\\/?p=2425\",\"url\":\"https:\\\/\\\/zjbocon.com\\\/?p=2425\",\"name\":\"EO sterilization equipment and process characteristic patterns and effect analysis - ETO STERILIZER\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/zjbocon.com\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/zjbocon.com\\\/?p=2425#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/zjbocon.com\\\/?p=2425#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/zjbocon.com\\\/wp-content\\\/uploads\\\/2025\\\/09\\\/ethylene-oxide-sterilization-68.webp\",\"datePublished\":\"2024-12-17T02:45:20+00:00\",\"dateModified\":\"2026-02-09T01:58:51+00:00\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/zjbocon.com\\\/?p=2425#breadcrumb\"},\"inLanguage\":\"af\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/zjbocon.com\\\/?p=2425\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"af\",\"@id\":\"https:\\\/\\\/zjbocon.com\\\/?p=2425#primaryimage\",\"url\":\"https:\\\/\\\/zjbocon.com\\\/wp-content\\\/uploads\\\/2025\\\/09\\\/ethylene-oxide-sterilization-68.webp\",\"contentUrl\":\"https:\\\/\\\/zjbocon.com\\\/wp-content\\\/uploads\\\/2025\\\/09\\\/ethylene-oxide-sterilization-68.webp\",\"width\":384,\"height\":512},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/zjbocon.com\\\/?p=2425#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/zjbocon.com\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"EO sterilization equipment and process characteristic patterns and effect analysis\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/zjbocon.com\\\/#website\",\"url\":\"https:\\\/\\\/zjbocon.com\\\/\",\"name\":\"ETO STERILIZER\",\"description\":\"One-stop Solution Supplier of Ethylene Oxide Sterilization\",\"publisher\":{\"@id\":\"https:\\\/\\\/zjbocon.com\\\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/zjbocon.com\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"af\"},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/zjbocon.com\\\/#organization\",\"name\":\"ETO STERILIZER\",\"url\":\"https:\\\/\\\/zjbocon.com\\\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"af\",\"@id\":\"https:\\\/\\\/zjbocon.com\\\/#\\\/schema\\\/logo\\\/image\\\/\",\"url\":\"https:\\\/\\\/zjbocon.com\\\/wp-content\\\/uploads\\\/2024\\\/10\\\/logo-1.webp\",\"contentUrl\":\"https:\\\/\\\/zjbocon.com\\\/wp-content\\\/uploads\\\/2024\\\/10\\\/logo-1.webp\",\"width\":180,\"height\":60,\"caption\":\"ETO STERILIZER\"},\"image\":{\"@id\":\"https:\\\/\\\/zjbocon.com\\\/#\\\/schema\\\/logo\\\/image\\\/\"},\"sameAs\":[\"https:\\\/\\\/www.facebook.com\\\/profile.php?id=100088482339878\",\"https:\\\/\\\/x.com\\\/BoconAnd\",\"https:\\\/\\\/www.linkedin.com\\\/in\\\/--06a221139\\\/\"]},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/zjbocon.com\\\/#\\\/schema\\\/person\\\/f12be028b8ae9843a4396dcc8012b425\",\"name\":\"Bocon Technical Team\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"af\",\"@id\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/d7a825658be227f26b237e519f8541e05aabc9ff27b8eec4544a233a48c53be0?s=96&d=identicon&r=g\",\"url\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/d7a825658be227f26b237e519f8541e05aabc9ff27b8eec4544a233a48c53be0?s=96&d=identicon&r=g\",\"contentUrl\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/d7a825658be227f26b237e519f8541e05aabc9ff27b8eec4544a233a48c53be0?s=96&d=identicon&r=g\",\"caption\":\"Bocon Technical Team\"},\"sameAs\":[\"https:\\\/\\\/zjbocon.com\\\/\",\"https:\\\/\\\/www.facebook.com\\\/profile.php?id=100088482339878\",\"https:\\\/\\\/www.linkedin.com\\\/in\\\/\\\/hayley--968190269\\\/\"],\"url\":\"https:\\\/\\\/zjbocon.com\\\/?author=234312599\"}]}<\/script>\n<!-- \/ Yoast SEO Premium plugin. -->","yoast_head_json":{"title":"EO sterilization equipment and process characteristic patterns and effect analysis - ETO STERILIZER","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/zjbocon.com\/?p=2425","og_locale":"en_US","og_type":"article","og_title":"EO sterilization equipment and process characteristic patterns and effect analysis","og_description":"Start cycle phase(Select parameters\/sterilization recipe) Serial number Potentially risky content Risk assessment under existing process conditions Risk assessment of the [&hellip;]","og_url":"https:\/\/zjbocon.com\/?p=2425","og_site_name":"ETO STERILIZER","article_publisher":"https:\/\/www.facebook.com\/profile.php?id=100088482339878","article_author":"https:\/\/www.facebook.com\/profile.php?id=100088482339878","article_published_time":"2024-12-17T02:45:20+00:00","article_modified_time":"2026-02-09T01:58:51+00:00","og_image":[{"width":384,"height":512,"url":"https:\/\/zjbocon.com\/wp-content\/uploads\/2025\/09\/ethylene-oxide-sterilization-68.webp","type":"image\/webp"}],"author":"Bocon Technical Team","twitter_card":"summary_large_image","twitter_creator":"@BoconAnd","twitter_site":"@BoconAnd","twitter_misc":{"Written by":"Bocon Technical Team","Est. reading time":"23 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/zjbocon.com\/?p=2425#article","isPartOf":{"@id":"https:\/\/zjbocon.com\/?p=2425"},"author":{"name":"Bocon Technical Team","@id":"https:\/\/zjbocon.com\/#\/schema\/person\/f12be028b8ae9843a4396dcc8012b425"},"headline":"EO sterilization equipment and process characteristic patterns and effect analysis","datePublished":"2024-12-17T02:45:20+00:00","dateModified":"2026-02-09T01:58:51+00:00","mainEntityOfPage":{"@id":"https:\/\/zjbocon.com\/?p=2425"},"wordCount":3962,"commentCount":0,"publisher":{"@id":"https:\/\/zjbocon.com\/#organization"},"image":{"@id":"https:\/\/zjbocon.com\/?p=2425#primaryimage"},"thumbnailUrl":"https:\/\/zjbocon.com\/wp-content\/uploads\/2025\/09\/ethylene-oxide-sterilization-68.webp","articleSection":["ETO STERILIZER"],"inLanguage":"af","potentialAction":[{"@type":"CommentAction","name":"Comment","target":["https:\/\/zjbocon.com\/?p=2425#respond"]}]},{"@type":"WebPage","@id":"https:\/\/zjbocon.com\/?p=2425","url":"https:\/\/zjbocon.com\/?p=2425","name":"EO sterilization equipment and process characteristic patterns and effect analysis - ETO STERILIZER","isPartOf":{"@id":"https:\/\/zjbocon.com\/#website"},"primaryImageOfPage":{"@id":"https:\/\/zjbocon.com\/?p=2425#primaryimage"},"image":{"@id":"https:\/\/zjbocon.com\/?p=2425#primaryimage"},"thumbnailUrl":"https:\/\/zjbocon.com\/wp-content\/uploads\/2025\/09\/ethylene-oxide-sterilization-68.webp","datePublished":"2024-12-17T02:45:20+00:00","dateModified":"2026-02-09T01:58:51+00:00","breadcrumb":{"@id":"https:\/\/zjbocon.com\/?p=2425#breadcrumb"},"inLanguage":"af","potentialAction":[{"@type":"ReadAction","target":["https:\/\/zjbocon.com\/?p=2425"]}]},{"@type":"ImageObject","inLanguage":"af","@id":"https:\/\/zjbocon.com\/?p=2425#primaryimage","url":"https:\/\/zjbocon.com\/wp-content\/uploads\/2025\/09\/ethylene-oxide-sterilization-68.webp","contentUrl":"https:\/\/zjbocon.com\/wp-content\/uploads\/2025\/09\/ethylene-oxide-sterilization-68.webp","width":384,"height":512},{"@type":"BreadcrumbList","@id":"https:\/\/zjbocon.com\/?p=2425#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/zjbocon.com\/"},{"@type":"ListItem","position":2,"name":"EO sterilization equipment and process characteristic patterns and effect analysis"}]},{"@type":"WebSite","@id":"https:\/\/zjbocon.com\/#website","url":"https:\/\/zjbocon.com\/","name":"ETO STERILIZER","description":"One-stop Solution Supplier of Ethylene Oxide Sterilization","publisher":{"@id":"https:\/\/zjbocon.com\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/zjbocon.com\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"af"},{"@type":"Organization","@id":"https:\/\/zjbocon.com\/#organization","name":"ETO STERILIZER","url":"https:\/\/zjbocon.com\/","logo":{"@type":"ImageObject","inLanguage":"af","@id":"https:\/\/zjbocon.com\/#\/schema\/logo\/image\/","url":"https:\/\/zjbocon.com\/wp-content\/uploads\/2024\/10\/logo-1.webp","contentUrl":"https:\/\/zjbocon.com\/wp-content\/uploads\/2024\/10\/logo-1.webp","width":180,"height":60,"caption":"ETO STERILIZER"},"image":{"@id":"https:\/\/zjbocon.com\/#\/schema\/logo\/image\/"},"sameAs":["https:\/\/www.facebook.com\/profile.php?id=100088482339878","https:\/\/x.com\/BoconAnd","https:\/\/www.linkedin.com\/in\/--06a221139\/"]},{"@type":"Person","@id":"https:\/\/zjbocon.com\/#\/schema\/person\/f12be028b8ae9843a4396dcc8012b425","name":"Bocon Technical Team","image":{"@type":"ImageObject","inLanguage":"af","@id":"https:\/\/secure.gravatar.com\/avatar\/d7a825658be227f26b237e519f8541e05aabc9ff27b8eec4544a233a48c53be0?s=96&d=identicon&r=g","url":"https:\/\/secure.gravatar.com\/avatar\/d7a825658be227f26b237e519f8541e05aabc9ff27b8eec4544a233a48c53be0?s=96&d=identicon&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/d7a825658be227f26b237e519f8541e05aabc9ff27b8eec4544a233a48c53be0?s=96&d=identicon&r=g","caption":"Bocon Technical Team"},"sameAs":["https:\/\/zjbocon.com\/","https:\/\/www.facebook.com\/profile.php?id=100088482339878","https:\/\/www.linkedin.com\/in\/\/hayley--968190269\/"],"url":"https:\/\/zjbocon.com\/?author=234312599"}]}},"jetpack_publicize_connections":[],"jetpack_featured_media_url":"https:\/\/zjbocon.com\/wp-content\/uploads\/2025\/09\/ethylene-oxide-sterilization-68.webp","uagb_featured_image_src":{"full":["https:\/\/zjbocon.com\/wp-content\/uploads\/2025\/09\/ethylene-oxide-sterilization-68.webp",384,512,false],"thumbnail":["https:\/\/zjbocon.com\/wp-content\/uploads\/2025\/09\/ethylene-oxide-sterilization-68-150x150.webp",150,150,true],"medium":["https:\/\/zjbocon.com\/wp-content\/uploads\/2025\/09\/ethylene-oxide-sterilization-68-225x300.webp",225,300,true],"medium_large":["https:\/\/zjbocon.com\/wp-content\/uploads\/2025\/09\/ethylene-oxide-sterilization-68.webp",384,512,false],"large":["https:\/\/zjbocon.com\/wp-content\/uploads\/2025\/09\/ethylene-oxide-sterilization-68.webp",384,512,false],"1536x1536":["https:\/\/zjbocon.com\/wp-content\/uploads\/2025\/09\/ethylene-oxide-sterilization-68.webp",384,512,false],"2048x2048":["https:\/\/zjbocon.com\/wp-content\/uploads\/2025\/09\/ethylene-oxide-sterilization-68.webp",384,512,false],"woocommerce_thumbnail":["https:\/\/zjbocon.com\/wp-content\/uploads\/2025\/09\/ethylene-oxide-sterilization-68.webp",384,512,false],"woocommerce_single":["https:\/\/zjbocon.com\/wp-content\/uploads\/2025\/09\/ethylene-oxide-sterilization-68.webp",384,512,false],"woocommerce_gallery_thumbnail":["https:\/\/zjbocon.com\/wp-content\/uploads\/2025\/09\/ethylene-oxide-sterilization-68-100x100.webp",100,100,true]},"uagb_author_info":{"display_name":"Bocon Technical Team","author_link":"https:\/\/zjbocon.com\/?author=234312599"},"uagb_comment_info":18,"uagb_excerpt":"Start cycle phase(Select parameters\/sterilization recipe) Serial number Potentially risky content Risk assessment under existing process conditions Risk assessment of the [&hellip;]","jetpack_likes_enabled":true,"jetpack_sharing_enabled":true,"jetpack_shortlink":"https:\/\/wp.me\/pgZDV6-D7","jetpack-related-posts":[{"id":1950,"url":"https:\/\/zjbocon.com\/?p=1950","url_meta":{"origin":2425,"position":0},"title":"eto sterilization process","author":"Bocon Technical Team","date":"2024-10-23","format":false,"excerpt":"Eto Sterilization is conducted using a eto sterilizer located in a dedicated facility.","rel":"","context":"In &quot;ETO STERILIZER&quot;","block_context":{"text":"ETO STERILIZER","link":"https:\/\/zjbocon.com\/?cat=133124"},"img":{"alt_text":"eto sterilization process","src":"https:\/\/i0.wp.com\/zjbocon.com\/wp-content\/uploads\/2024\/10\/eto-sterilization-process-e1729654271899.webp?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/zjbocon.com\/wp-content\/uploads\/2024\/10\/eto-sterilization-process-e1729654271899.webp?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/zjbocon.com\/wp-content\/uploads\/2024\/10\/eto-sterilization-process-e1729654271899.webp?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/zjbocon.com\/wp-content\/uploads\/2024\/10\/eto-sterilization-process-e1729654271899.webp?resize=700%2C400&ssl=1 2x"},"classes":[]},{"id":2094,"url":"https:\/\/zjbocon.com\/?p=2094","url_meta":{"origin":2425,"position":1},"title":"ETO Sterilizer Manufacturer-HZBOCON","author":"Bocon Technical Team","date":"2024-11-04","format":false,"excerpt":"Hangzhou Bocon Mechanical and Electrical Equipment Co., Ltd., commonly referred to as HZBOCON, stands out as a dedicated Ethylene Oxide (EO\/ETO) sterilizer manufacturer. Established in 2006, HZBOCON has committed itself to the design, development, and manufacturing of EO sterilization equipment, catering to a wide array of industries that require effective\u2026","rel":"","context":"In &quot;ETO STERILIZER&quot;","block_context":{"text":"ETO STERILIZER","link":"https:\/\/zjbocon.com\/?cat=133124"},"img":{"alt_text":"","src":"https:\/\/i0.wp.com\/zjbocon.com\/wp-content\/uploads\/2024\/11\/eto-sterilizer-hzbocon-4.png?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/zjbocon.com\/wp-content\/uploads\/2024\/11\/eto-sterilizer-hzbocon-4.png?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/zjbocon.com\/wp-content\/uploads\/2024\/11\/eto-sterilizer-hzbocon-4.png?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/zjbocon.com\/wp-content\/uploads\/2024\/11\/eto-sterilizer-hzbocon-4.png?resize=700%2C400&ssl=1 2x, https:\/\/i0.wp.com\/zjbocon.com\/wp-content\/uploads\/2024\/11\/eto-sterilizer-hzbocon-4.png?resize=1050%2C600&ssl=1 3x"},"classes":[]},{"id":2032,"url":"https:\/\/zjbocon.com\/?p=2032","url_meta":{"origin":2425,"position":2},"title":"The advantage of Ethylene oxide sterilizer","author":"Bocon Technical Team","date":"2024-10-29","format":false,"excerpt":"Ethylene oxide sterilizer operate at low temperatures, making them ideal for sterilizing heat-sensitive medical devices and instruments. This characteristic allows for the preservation of the integrity and functionality of complex medical devices that might be damaged by heat.","rel":"","context":"In &quot;ETO STERILIZER&quot;","block_context":{"text":"ETO STERILIZER","link":"https:\/\/zjbocon.com\/?cat=133124"},"img":{"alt_text":"","src":"https:\/\/i0.wp.com\/zjbocon.com\/wp-content\/uploads\/2024\/11\/eto-sterilizer-hzbocon-4.png?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/zjbocon.com\/wp-content\/uploads\/2024\/11\/eto-sterilizer-hzbocon-4.png?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/zjbocon.com\/wp-content\/uploads\/2024\/11\/eto-sterilizer-hzbocon-4.png?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/zjbocon.com\/wp-content\/uploads\/2024\/11\/eto-sterilizer-hzbocon-4.png?resize=700%2C400&ssl=1 2x, https:\/\/i0.wp.com\/zjbocon.com\/wp-content\/uploads\/2024\/11\/eto-sterilizer-hzbocon-4.png?resize=1050%2C600&ssl=1 3x"},"classes":[]},{"id":2224,"url":"https:\/\/zjbocon.com\/?p=2224","url_meta":{"origin":2425,"position":3},"title":"Factors Affecting the EO Gas Sterilization Process","author":"Bocon Technical Team","date":"2024-11-22","format":false,"excerpt":"Within a certain range of gas concentration, the higher the concentration, the better theEO Gas Sterilization effect; beyond 1000 mg\/L, the improvement in sterilization effect is not significant.","rel":"","context":"In &quot;ETO STERILIZER&quot;","block_context":{"text":"ETO STERILIZER","link":"https:\/\/zjbocon.com\/?cat=133124"},"img":{"alt_text":"","src":"https:\/\/i0.wp.com\/zjbocon.com\/wp-content\/uploads\/2025\/09\/ethylene-oxide-sterilization-10-scaled.webp?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/zjbocon.com\/wp-content\/uploads\/2025\/09\/ethylene-oxide-sterilization-10-scaled.webp?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/zjbocon.com\/wp-content\/uploads\/2025\/09\/ethylene-oxide-sterilization-10-scaled.webp?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/zjbocon.com\/wp-content\/uploads\/2025\/09\/ethylene-oxide-sterilization-10-scaled.webp?resize=700%2C400&ssl=1 2x, https:\/\/i0.wp.com\/zjbocon.com\/wp-content\/uploads\/2025\/09\/ethylene-oxide-sterilization-10-scaled.webp?resize=1050%2C600&ssl=1 3x, https:\/\/i0.wp.com\/zjbocon.com\/wp-content\/uploads\/2025\/09\/ethylene-oxide-sterilization-10-scaled.webp?resize=1400%2C800&ssl=1 4x"},"classes":[]},{"id":3093,"url":"https:\/\/zjbocon.com\/?p=3093","url_meta":{"origin":2425,"position":4},"title":"Introduction to Ethylene Oxide Sterilizers","author":"Bocon Technical Team","date":"2025-02-05","format":false,"excerpt":"Discover how ethylene oxide sterilizers work, their applications, benefits, and safety considerations. Learn why they are essential for medical and industrial sterilization.","rel":"","context":"In &quot;Company News&quot;","block_context":{"text":"Company News","link":"https:\/\/zjbocon.com\/?cat=133125"},"img":{"alt_text":"","src":"https:\/\/i0.wp.com\/zjbocon.com\/wp-content\/uploads\/2024\/11\/ethylene-oxide-sterilization-21.webp?resize=350%2C200","width":350,"height":200},"classes":[]},{"id":3190,"url":"https:\/\/zjbocon.com\/?p=3190","url_meta":{"origin":2425,"position":5},"title":"What Can Be Sterilized by Ethylene Oxide?","author":"Bocon Technical Team","date":"2025-02-12","format":false,"excerpt":"Ethylene Oxide (EO) gas sterilization is a highly effective method for sterilizing a wide range of items that are sensitive to heat, moisture, or radiation. ETO Sterile Medical Machines and ETO sterilizers are widely used in healthcare, pharmaceuticals, and industrial settings due to their ability to penetrate complex materials and\u2026","rel":"","context":"In &quot;Company News&quot;","block_context":{"text":"Company News","link":"https:\/\/zjbocon.com\/?cat=133125"},"img":{"alt_text":"","src":"https:\/\/i0.wp.com\/zjbocon.com\/wp-content\/uploads\/2025\/09\/ethylene-oxide-sterilization-25.webp?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/zjbocon.com\/wp-content\/uploads\/2025\/09\/ethylene-oxide-sterilization-25.webp?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/zjbocon.com\/wp-content\/uploads\/2025\/09\/ethylene-oxide-sterilization-25.webp?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/zjbocon.com\/wp-content\/uploads\/2025\/09\/ethylene-oxide-sterilization-25.webp?resize=700%2C400&ssl=1 2x, https:\/\/i0.wp.com\/zjbocon.com\/wp-content\/uploads\/2025\/09\/ethylene-oxide-sterilization-25.webp?resize=1050%2C600&ssl=1 3x"},"classes":[]}],"_links":{"self":[{"href":"https:\/\/zjbocon.com\/index.php?rest_route=\/wp\/v2\/posts\/2425","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/zjbocon.com\/index.php?rest_route=\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/zjbocon.com\/index.php?rest_route=\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/zjbocon.com\/index.php?rest_route=\/wp\/v2\/users\/234312599"}],"replies":[{"embeddable":true,"href":"https:\/\/zjbocon.com\/index.php?rest_route=%2Fwp%2Fv2%2Fcomments&post=2425"}],"version-history":[{"count":13,"href":"https:\/\/zjbocon.com\/index.php?rest_route=\/wp\/v2\/posts\/2425\/revisions"}],"predecessor-version":[{"id":8866,"href":"https:\/\/zjbocon.com\/index.php?rest_route=\/wp\/v2\/posts\/2425\/revisions\/8866"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/zjbocon.com\/index.php?rest_route=\/wp\/v2\/media\/8473"}],"wp:attachment":[{"href":"https:\/\/zjbocon.com\/index.php?rest_route=%2Fwp%2Fv2%2Fmedia&parent=2425"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/zjbocon.com\/index.php?rest_route=%2Fwp%2Fv2%2Fcategories&post=2425"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/zjbocon.com\/index.php?rest_route=%2Fwp%2Fv2%2Ftags&post=2425"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}