{"id":2047,"date":"2024-10-30T11:16:45","date_gmt":"2024-10-30T03:16:45","guid":{"rendered":"https:\/\/zjbocon.com\/?p=2047"},"modified":"2025-12-05T11:16:43","modified_gmt":"2025-12-05T03:16:43","slug":"iq-in-eto-sterilization-process","status":"publish","type":"post","link":"https:\/\/zjbocon.com\/?p=2047","title":{"rendered":"IQ IN ETO STERILIZATION PROCESS"},"content":{"rendered":"\n<p class=\"wp-block-paragraph\">Iq በኢቶ የማምከን ሂደት የተካሄደው የማምከንያ መሳሪያዎችና ማናቸውንም ረዳት እቃዎች በገለፃቸው መሰረት ቀርበው መጫኑን ለማሳየት ነው። IQ ን ከማከናወኑ በፊት መሳሪያው አምራቹ በመደበኛነት መደረሱን ለማረጋገጥ FAT እና SAT ያካሂዳል።<\/p>\n\n\n\n<div class=\"wp-block-uagb-image uagb-block-a3122174 wp-block-uagb-image--layout-default wp-block-uagb-image--effect-static wp-block-uagb-image--align-none\"><figure class=\"wp-block-uagb-image__figure\"><img loading=\"lazy\" decoding=\"async\" src=\"https:\/\/zjbocon.com\/wp-content\/uploads\/2025\/09\/Ethylene-Oxide-Sterilizer-Installation-Guide-1-1024x473.webp\" alt=\"\" class=\"uag-image-8475\" width=\"1024\" height=\"473\" title=\"Ethylene-Oxide-Sterilizer-Installation-Guide-1\" role=\"img\" \><\/figure><\/div>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"h-during-iq-the-following-events-need-to-be-further-identified-and-substantiated\">በ IQ ጊዜ የሚከተሉት ክስተቶች የበለጠ ተለይተው ሊታወቁ እና ሊረጋገጡ ይገባል.<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">a. በማምከን ሂደት ውስጥ ጥቅም ላይ የሚውሉ መሳሪያዎች, ማንኛውም ረዳት እቃዎችን ጨምሮ, የንድፍ ዝርዝሮችን ማክበር አለባቸው.ተዛማጅ ሰነዶች ተግባራዊ የንድፍ ዝርዝሮች, የተጠቃሚ መስፈርቶች ዝርዝር መግለጫዎች, የንድፍ ስዕሎች, ወዘተ.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">ለ. ሁሉም ክፍሎች (የቁጥጥር ሶፍትዌርን ጨምሮ) በትክክል መስራታቸውን ያረጋግጡ; ቁልፍ የመለኪያ መሣሪያዎችን ማስተካከል ያስፈልጋል; ቁልፍ አካል መረጃ መመዝገብ አለበት;<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">ሐ. የመጫኑ እና የአጠቃቀም አካባቢው ደህንነቱ የተጠበቀ እና የአካባቢ ደንቦችን የሚያከብር መሆኑን ያረጋግጡ። የደህንነት እና የሰራተኞች ጤና መስፈርቶችን ያሟሉ.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">መ. የጥገና እና ልዩ አያያዝ ሰነዶችን ጨምሮ የደህንነት ምርት እና የአሠራር ሂደት ሰነዶችን ማዘጋጀት; የኦፕሬተር ስልጠና ማካሄድ; ኦፕሬተሮች ሥራ መጀመር የሚችሉት ብቁ ከሆኑ በኋላ ብቻ ነው።<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">ሠ. IQ ለማምከን ሂደት ለሚቀጠሩ ልዩ መሳሪያዎች የአንድ ጊዜ የአካል ብቃት እንቅስቃሴ ሊሆን ይችላል።<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">ረ. ጉልህ የአካል ክፍሎች ለውጦች ወይም የተግባር ለውጦች ሲከሰቱ ተጨማሪ IQ መከናወን አለበት።<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"h-if-you-want-to-know-more-about-iq-in-eto-sterilization-process\">በኢቶ የማምከን ሂደት ውስጥ ስለ IQ የበለጠ ማወቅ ከፈለጉ<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">ስልክ፡<a href=\"https:\/\/wa.me\/8619975258603\">+8619975258603<\/a><\/p>\n\n\n\n<p class=\"wp-block-paragraph\">ኢሜይል፡-<a href=\"mailto:hayley@hzbocon.com\">hayley@hzbocon.com<\/a><\/p>\n\n\n\n<p class=\"wp-block-paragraph\">የአካባቢ ቦታ፡ ክፍል 1202፣ ካይቶንግ ዞንግክሲን፣ ዢያሻ አውራጃ፣ ሃንግዙ ከተማ፣ ዢጂያንግ ግዛት፣ ቻይና<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">ድህረገፅ፥<a href=\"https:\/\/www.hzbocon.com\/\">hzbocon.com<\/a><a href=\"https:\/\/zjbocon.com\/\">zjbocon.com<\/a><\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><\/p>\n","protected":false},"excerpt":{"rendered":"<p>a.Equipment to be used in the sterilization process, including any\u00a0ancillary items, shall comply with its design specifications.The corresponding documents include functional design specifications, user requirements specifications, design drawings, etc. (Equipment schematic diagram, energy supply diagram, electrical schematic diagram, system schematic diagram, etc.)<\/p>\n","protected":false},"author":234312599,"featured_media":8475,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_uag_custom_page_level_css":"","site-sidebar-layout":"default","site-content-layout":"","ast-site-content-layout":"default","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","ast-disable-related-posts":"","theme-transparent-header-meta":"","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"set","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"_jetpack_newsletter_access":"","_jetpack_dont_email_post_to_subs":false,"_jetpack_newsletter_tier_id":0,"_jetpack_memberships_contains_paywalled_content":false,"_jetpack_feature_clip_id":0,"_jetpack_memberships_contains_paid_content":false,"footnotes":"","jetpack_publicize_message":"","jetpack_publicize_feature_enabled":true,"jetpack_social_post_already_shared":false,"jetpack_social_options":{"image_generator_settings":{"template":"highway","enabled":false},"version":2},"jetpack_post_was_ever_published":false},"categories":[133124],"tags":[],"class_list":["post-2047","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-eto-sterilizer"],"yoast_head":"<!-- This site is optimized with the Yoast SEO Premium plugin v27.2 (Yoast SEO v28.0) - https:\/\/yoast.com\/product\/yoast-seo-premium-wordpress\/ -->\n<title>IQ በኢቶ የማምከን ሂደት - ኢቶ ስቴሪላይዘር<\/title>\n<meta name=\"description\" content=\"Iq in eto sterilization process is undertaken to demonstrate that the equipment and any ancillary items have been\" \>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \>\n<link rel=\"canonical\" href=\"https:\/\/zjbocon.com\/?p=2047\" \>\n<meta property=\"og:locale\" content=\"en_US\" \>\n<meta property=\"og:type\" content=\"article\" \>\n<meta property=\"og:title\" content=\"IQ IN ETO STERILIZATION PROCESS\" \>\n<meta property=\"og:description\" content=\"Iq in eto sterilization process is undertaken to demonstrate that the equipment and any ancillary items have been\" \>\n<meta property=\"og:url\" content=\"https:\/\/zjbocon.com\/?p=2047\" \>\n<meta property=\"og:site_name\" content=\"ETO STERILIZER\" \>\n<meta property=\"article:publisher\" content=\"https:\/\/www.facebook.com\/profile.php?id=100088482339878\" \>\n<meta property=\"article:author\" content=\"https:\/\/www.facebook.com\/profile.php?id=100088482339878\" \>\n<meta property=\"article:published_time\" content=\"2024-10-30T03:16:45+00:00\" \>\n<meta property=\"article:modified_time\" content=\"2025-12-05T03:16:43+00:00\" \>\n<meta property=\"og:image\" content=\"https:\/\/zjbocon.com\/wp-content\/uploads\/2025\/09\/Ethylene-Oxide-Sterilizer-Installation-Guide-1-scaled.webp\" \>\n\t<meta property=\"og:image:width\" content=\"2560\" \>\n\t<meta property=\"og:image:height\" content=\"1183\" \>\n\t<meta property=\"og:image:type\" content=\"image\/webp\" \>\n<meta name=\"author\" content=\"Bocon Technical Team\" \>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \>\n<meta name=\"twitter:creator\" content=\"@BoconAnd\" \>\n<meta name=\"twitter:site\" content=\"@BoconAnd\" \>\n<meta name=\"twitter:label1\" content=\"Written by\" \>\n\t<meta name=\"twitter:data1\" content=\"Bocon Technical Team\" \>\n\t<meta name=\"twitter:label2\" content=\"Est. reading time\" \>\n\t<meta name=\"twitter:data2\" content=\"2 minutes\" \>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\\\/\\\/zjbocon.com\\\/?p=2047#article\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/zjbocon.com\\\/?p=2047\"},\"author\":{\"name\":\"Bocon Technical Team\",\"@id\":\"https:\\\/\\\/zjbocon.com\\\/#\\\/schema\\\/person\\\/f12be028b8ae9843a4396dcc8012b425\"},\"headline\":\"IQ IN ETO STERILIZATION PROCESS\",\"datePublished\":\"2024-10-30T03:16:45+00:00\",\"dateModified\":\"2025-12-05T03:16:43+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/zjbocon.com\\\/?p=2047\"},\"wordCount\":254,\"commentCount\":0,\"publisher\":{\"@id\":\"https:\\\/\\\/zjbocon.com\\\/#organization\"},\"image\":{\"@id\":\"https:\\\/\\\/zjbocon.com\\\/?p=2047#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/zjbocon.com\\\/wp-content\\\/uploads\\\/2025\\\/09\\\/Ethylene-Oxide-Sterilizer-Installation-Guide-1-scaled.webp\",\"articleSection\":[\"ETO STERILIZER\"],\"inLanguage\":\"am\",\"potentialAction\":[{\"@type\":\"CommentAction\",\"name\":\"Comment\",\"target\":[\"https:\\\/\\\/zjbocon.com\\\/?p=2047#respond\"]}]},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/zjbocon.com\\\/?p=2047\",\"url\":\"https:\\\/\\\/zjbocon.com\\\/?p=2047\",\"name\":\"IQ IN ETO STERILIZATION PROCESS - ETO STERILIZER\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/zjbocon.com\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/zjbocon.com\\\/?p=2047#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/zjbocon.com\\\/?p=2047#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/zjbocon.com\\\/wp-content\\\/uploads\\\/2025\\\/09\\\/Ethylene-Oxide-Sterilizer-Installation-Guide-1-scaled.webp\",\"datePublished\":\"2024-10-30T03:16:45+00:00\",\"dateModified\":\"2025-12-05T03:16:43+00:00\",\"description\":\"Iq in eto sterilization process is undertaken to demonstrate that the sterilization equipment and any ancillary items have been\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/zjbocon.com\\\/?p=2047#breadcrumb\"},\"inLanguage\":\"am\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/zjbocon.com\\\/?p=2047\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"am\",\"@id\":\"https:\\\/\\\/zjbocon.com\\\/?p=2047#primaryimage\",\"url\":\"https:\\\/\\\/zjbocon.com\\\/wp-content\\\/uploads\\\/2025\\\/09\\\/Ethylene-Oxide-Sterilizer-Installation-Guide-1-scaled.webp\",\"contentUrl\":\"https:\\\/\\\/zjbocon.com\\\/wp-content\\\/uploads\\\/2025\\\/09\\\/Ethylene-Oxide-Sterilizer-Installation-Guide-1-scaled.webp\",\"width\":2560,\"height\":1183},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/zjbocon.com\\\/?p=2047#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/zjbocon.com\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"IQ IN ETO STERILIZATION PROCESS\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/zjbocon.com\\\/#website\",\"url\":\"https:\\\/\\\/zjbocon.com\\\/\",\"name\":\"ETO STERILIZER\",\"description\":\"One-stop Solution Supplier of Ethylene Oxide Sterilization\",\"publisher\":{\"@id\":\"https:\\\/\\\/zjbocon.com\\\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/zjbocon.com\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"am\"},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/zjbocon.com\\\/#organization\",\"name\":\"ETO STERILIZER\",\"url\":\"https:\\\/\\\/zjbocon.com\\\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"am\",\"@id\":\"https:\\\/\\\/zjbocon.com\\\/#\\\/schema\\\/logo\\\/image\\\/\",\"url\":\"https:\\\/\\\/zjbocon.com\\\/wp-content\\\/uploads\\\/2024\\\/10\\\/logo-1.webp\",\"contentUrl\":\"https:\\\/\\\/zjbocon.com\\\/wp-content\\\/uploads\\\/2024\\\/10\\\/logo-1.webp\",\"width\":180,\"height\":60,\"caption\":\"ETO STERILIZER\"},\"image\":{\"@id\":\"https:\\\/\\\/zjbocon.com\\\/#\\\/schema\\\/logo\\\/image\\\/\"},\"sameAs\":[\"https:\\\/\\\/www.facebook.com\\\/profile.php?id=100088482339878\",\"https:\\\/\\\/x.com\\\/BoconAnd\",\"https:\\\/\\\/www.linkedin.com\\\/in\\\/--06a221139\\\/\"]},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/zjbocon.com\\\/#\\\/schema\\\/person\\\/f12be028b8ae9843a4396dcc8012b425\",\"name\":\"Bocon Technical Team\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"am\",\"@id\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/d7a825658be227f26b237e519f8541e05aabc9ff27b8eec4544a233a48c53be0?s=96&d=identicon&r=g\",\"url\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/d7a825658be227f26b237e519f8541e05aabc9ff27b8eec4544a233a48c53be0?s=96&d=identicon&r=g\",\"contentUrl\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/d7a825658be227f26b237e519f8541e05aabc9ff27b8eec4544a233a48c53be0?s=96&d=identicon&r=g\",\"caption\":\"Bocon Technical Team\"},\"sameAs\":[\"https:\\\/\\\/zjbocon.com\\\/\",\"https:\\\/\\\/www.facebook.com\\\/profile.php?id=100088482339878\",\"https:\\\/\\\/www.linkedin.com\\\/in\\\/\\\/hayley--968190269\\\/\"],\"url\":\"https:\\\/\\\/zjbocon.com\\\/?author=234312599\"}]}<\/script>\n<!-- \/ Yoast SEO Premium plugin. -->","yoast_head_json":{"title":"IQ IN ETO STERILIZATION PROCESS - ETO STERILIZER","description":"Iq in eto sterilization process is undertaken to demonstrate that the sterilization equipment and any ancillary items have been","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/zjbocon.com\/?p=2047","og_locale":"en_US","og_type":"article","og_title":"IQ IN ETO STERILIZATION PROCESS","og_description":"Iq in eto sterilization process is undertaken to demonstrate that the sterilization equipment and any ancillary items have been","og_url":"https:\/\/zjbocon.com\/?p=2047","og_site_name":"ETO STERILIZER","article_publisher":"https:\/\/www.facebook.com\/profile.php?id=100088482339878","article_author":"https:\/\/www.facebook.com\/profile.php?id=100088482339878","article_published_time":"2024-10-30T03:16:45+00:00","article_modified_time":"2025-12-05T03:16:43+00:00","og_image":[{"width":2560,"height":1183,"url":"https:\/\/zjbocon.com\/wp-content\/uploads\/2025\/09\/Ethylene-Oxide-Sterilizer-Installation-Guide-1-scaled.webp","type":"image\/webp"}],"author":"Bocon Technical Team","twitter_card":"summary_large_image","twitter_creator":"@BoconAnd","twitter_site":"@BoconAnd","twitter_misc":{"Written by":"Bocon Technical Team","Est. reading time":"2 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/zjbocon.com\/?p=2047#article","isPartOf":{"@id":"https:\/\/zjbocon.com\/?p=2047"},"author":{"name":"Bocon Technical Team","@id":"https:\/\/zjbocon.com\/#\/schema\/person\/f12be028b8ae9843a4396dcc8012b425"},"headline":"IQ IN ETO STERILIZATION PROCESS","datePublished":"2024-10-30T03:16:45+00:00","dateModified":"2025-12-05T03:16:43+00:00","mainEntityOfPage":{"@id":"https:\/\/zjbocon.com\/?p=2047"},"wordCount":254,"commentCount":0,"publisher":{"@id":"https:\/\/zjbocon.com\/#organization"},"image":{"@id":"https:\/\/zjbocon.com\/?p=2047#primaryimage"},"thumbnailUrl":"https:\/\/zjbocon.com\/wp-content\/uploads\/2025\/09\/Ethylene-Oxide-Sterilizer-Installation-Guide-1-scaled.webp","articleSection":["ETO STERILIZER"],"inLanguage":"am","potentialAction":[{"@type":"CommentAction","name":"Comment","target":["https:\/\/zjbocon.com\/?p=2047#respond"]}]},{"@type":"WebPage","@id":"https:\/\/zjbocon.com\/?p=2047","url":"https:\/\/zjbocon.com\/?p=2047","name":"IQ IN ETO STERILIZATION PROCESS - ETO STERILIZER","isPartOf":{"@id":"https:\/\/zjbocon.com\/#website"},"primaryImageOfPage":{"@id":"https:\/\/zjbocon.com\/?p=2047#primaryimage"},"image":{"@id":"https:\/\/zjbocon.com\/?p=2047#primaryimage"},"thumbnailUrl":"https:\/\/zjbocon.com\/wp-content\/uploads\/2025\/09\/Ethylene-Oxide-Sterilizer-Installation-Guide-1-scaled.webp","datePublished":"2024-10-30T03:16:45+00:00","dateModified":"2025-12-05T03:16:43+00:00","description":"Iq in eto sterilization process is undertaken to demonstrate that the sterilization equipment and any ancillary items have been","breadcrumb":{"@id":"https:\/\/zjbocon.com\/?p=2047#breadcrumb"},"inLanguage":"am","potentialAction":[{"@type":"ReadAction","target":["https:\/\/zjbocon.com\/?p=2047"]}]},{"@type":"ImageObject","inLanguage":"am","@id":"https:\/\/zjbocon.com\/?p=2047#primaryimage","url":"https:\/\/zjbocon.com\/wp-content\/uploads\/2025\/09\/Ethylene-Oxide-Sterilizer-Installation-Guide-1-scaled.webp","contentUrl":"https:\/\/zjbocon.com\/wp-content\/uploads\/2025\/09\/Ethylene-Oxide-Sterilizer-Installation-Guide-1-scaled.webp","width":2560,"height":1183},{"@type":"BreadcrumbList","@id":"https:\/\/zjbocon.com\/?p=2047#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/zjbocon.com\/"},{"@type":"ListItem","position":2,"name":"IQ IN ETO STERILIZATION PROCESS"}]},{"@type":"WebSite","@id":"https:\/\/zjbocon.com\/#website","url":"https:\/\/zjbocon.com\/","name":"ETO STERILIZER","description":"One-stop Solution Supplier of Ethylene Oxide Sterilization","publisher":{"@id":"https:\/\/zjbocon.com\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/zjbocon.com\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"am"},{"@type":"Organization","@id":"https:\/\/zjbocon.com\/#organization","name":"ETO STERILIZER","url":"https:\/\/zjbocon.com\/","logo":{"@type":"ImageObject","inLanguage":"am","@id":"https:\/\/zjbocon.com\/#\/schema\/logo\/image\/","url":"https:\/\/zjbocon.com\/wp-content\/uploads\/2024\/10\/logo-1.webp","contentUrl":"https:\/\/zjbocon.com\/wp-content\/uploads\/2024\/10\/logo-1.webp","width":180,"height":60,"caption":"ETO STERILIZER"},"image":{"@id":"https:\/\/zjbocon.com\/#\/schema\/logo\/image\/"},"sameAs":["https:\/\/www.facebook.com\/profile.php?id=100088482339878","https:\/\/x.com\/BoconAnd","https:\/\/www.linkedin.com\/in\/--06a221139\/"]},{"@type":"Person","@id":"https:\/\/zjbocon.com\/#\/schema\/person\/f12be028b8ae9843a4396dcc8012b425","name":"Bocon Technical Team","image":{"@type":"ImageObject","inLanguage":"am","@id":"https:\/\/secure.gravatar.com\/avatar\/d7a825658be227f26b237e519f8541e05aabc9ff27b8eec4544a233a48c53be0?s=96&d=identicon&r=g","url":"https:\/\/secure.gravatar.com\/avatar\/d7a825658be227f26b237e519f8541e05aabc9ff27b8eec4544a233a48c53be0?s=96&d=identicon&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/d7a825658be227f26b237e519f8541e05aabc9ff27b8eec4544a233a48c53be0?s=96&d=identicon&r=g","caption":"Bocon Technical Team"},"sameAs":["https:\/\/zjbocon.com\/","https:\/\/www.facebook.com\/profile.php?id=100088482339878","https:\/\/www.linkedin.com\/in\/\/hayley--968190269\/"],"url":"https:\/\/zjbocon.com\/?author=234312599"}]}},"jetpack_publicize_connections":[],"jetpack_featured_media_url":"https:\/\/zjbocon.com\/wp-content\/uploads\/2025\/09\/Ethylene-Oxide-Sterilizer-Installation-Guide-1-scaled.webp","uagb_featured_image_src":{"full":["https:\/\/zjbocon.com\/wp-content\/uploads\/2025\/09\/Ethylene-Oxide-Sterilizer-Installation-Guide-1-scaled.webp",2560,1183,false],"thumbnail":["https:\/\/zjbocon.com\/wp-content\/uploads\/2025\/09\/Ethylene-Oxide-Sterilizer-Installation-Guide-1-150x150.webp",150,150,true],"medium":["https:\/\/zjbocon.com\/wp-content\/uploads\/2025\/09\/Ethylene-Oxide-Sterilizer-Installation-Guide-1-300x139.webp",300,139,true],"medium_large":["https:\/\/zjbocon.com\/wp-content\/uploads\/2025\/09\/Ethylene-Oxide-Sterilizer-Installation-Guide-1-768x355.webp",768,355,true],"large":["https:\/\/zjbocon.com\/wp-content\/uploads\/2025\/09\/Ethylene-Oxide-Sterilizer-Installation-Guide-1-1024x473.webp",1024,473,true],"1536x1536":["https:\/\/zjbocon.com\/wp-content\/uploads\/2025\/09\/Ethylene-Oxide-Sterilizer-Installation-Guide-1-1536x710.webp",1536,710,true],"2048x2048":["https:\/\/zjbocon.com\/wp-content\/uploads\/2025\/09\/Ethylene-Oxide-Sterilizer-Installation-Guide-1-2048x946.webp",2048,946,true],"woocommerce_thumbnail":["https:\/\/zjbocon.com\/wp-content\/uploads\/2025\/09\/Ethylene-Oxide-Sterilizer-Installation-Guide-1-600x600.webp",600,600,true],"woocommerce_single":["https:\/\/zjbocon.com\/wp-content\/uploads\/2025\/09\/Ethylene-Oxide-Sterilizer-Installation-Guide-1-600x277.webp",600,277,true],"woocommerce_gallery_thumbnail":["https:\/\/zjbocon.com\/wp-content\/uploads\/2025\/09\/Ethylene-Oxide-Sterilizer-Installation-Guide-1-100x100.webp",100,100,true]},"uagb_author_info":{"display_name":"Bocon Technical Team","author_link":"https:\/\/zjbocon.com\/?author=234312599"},"uagb_comment_info":17,"uagb_excerpt":"a.Equipment to be used in the sterilization process, including any\u00a0ancillary items, shall comply with its design specifications.The corresponding documents include functional design specifications, user requirements specifications, design drawings, etc. (Equipment schematic diagram, energy supply diagram, electrical schematic diagram, system schematic diagram, etc.)","jetpack_likes_enabled":true,"jetpack_sharing_enabled":true,"jetpack_shortlink":"https:\/\/wp.me\/pgZDV6-x1","jetpack-related-posts":[{"id":2013,"url":"https:\/\/zjbocon.com\/?p=2013","url_meta":{"origin":2047,"position":0},"title":"Purpose for eto sterilization validation","author":"Bocon Technical Team","date":"2024-10-28","format":false,"excerpt":"1.Purpose\u00a0for validation eto sterilization 1.1.the obtain of eto sterilization validation evidence that the equipment used for ETO sterilization has been provided and installed in accordance with its specification and can stably operate within predetermined limits and consistently performs in accordance with predetermined criteria and thereby yields product meeting its specification.\u2026","rel":"","context":"In &quot;ETO STERILIZER&quot;","block_context":{"text":"ETO STERILIZER","link":"https:\/\/zjbocon.com\/?cat=133124"},"img":{"alt_text":"eto sterilization validation","src":"https:\/\/i0.wp.com\/zjbocon.com\/wp-content\/uploads\/2024\/10\/Qualification_Services-2.webp?resize=350%2C200","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/zjbocon.com\/wp-content\/uploads\/2024\/10\/Qualification_Services-2.webp?resize=350%2C200 1x, https:\/\/i0.wp.com\/zjbocon.com\/wp-content\/uploads\/2024\/10\/Qualification_Services-2.webp?resize=525%2C300 1.5x, https:\/\/i0.wp.com\/zjbocon.com\/wp-content\/uploads\/2024\/10\/Qualification_Services-2.webp?resize=700%2C400 2x"},"classes":[]},{"id":7286,"url":"https:\/\/zjbocon.com\/?p=7286","url_meta":{"origin":2047,"position":1},"title":"ETO Sterilization Re-qualification","author":"Bocon Technical Team","date":"2025-07-29","format":false,"excerpt":"ETO Sterilization Re-qualification Requirements 1. Re-qualification Frequency \u2022\u00a0Minimum annual requirement\u2022 At least once per year, verification data, subsequent re-validation data, and routine processing data must be reviewed\u2022 The scope of re-qualification must be determined and documented\u2022 The review procedure shall be documented 2. Is Re-qualification Needed if No Product Changes\u2026","rel":"","context":"In &quot;Company News&quot;","block_context":{"text":"Company News","link":"https:\/\/zjbocon.com\/?cat=133125"},"img":{"alt_text":"","src":"https:\/\/i0.wp.com\/zjbocon.com\/wp-content\/uploads\/2025\/09\/eto-sterilizer-9.webp?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/zjbocon.com\/wp-content\/uploads\/2025\/09\/eto-sterilizer-9.webp?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/zjbocon.com\/wp-content\/uploads\/2025\/09\/eto-sterilizer-9.webp?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/zjbocon.com\/wp-content\/uploads\/2025\/09\/eto-sterilizer-9.webp?resize=700%2C400&ssl=1 2x, https:\/\/i0.wp.com\/zjbocon.com\/wp-content\/uploads\/2025\/09\/eto-sterilizer-9.webp?resize=1050%2C600&ssl=1 3x"},"classes":[]},{"id":2076,"url":"https:\/\/zjbocon.com\/?p=2076","url_meta":{"origin":2047,"position":2},"title":"PQ in Ethylene oxide sterilization chamber","author":"Bocon Technical Team","date":"2024-10-31","format":false,"excerpt":"PQ is the stage of validation that uses Ethylene oxide sterilization chamber to demonstrate that the Ethylene oxide sterilization equipment consistently operates in accordance with predetermined acceptance criteria and the process yields a product that is sterile and meets the specified requirements.","rel":"","context":"In &quot;ETO STERILIZER&quot;","block_context":{"text":"ETO STERILIZER","link":"https:\/\/zjbocon.com\/?cat=133124"},"img":{"alt_text":"","src":"https:\/\/i0.wp.com\/zjbocon.com\/wp-content\/uploads\/2025\/09\/eto-sterilizer-1.webp?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/zjbocon.com\/wp-content\/uploads\/2025\/09\/eto-sterilizer-1.webp?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/zjbocon.com\/wp-content\/uploads\/2025\/09\/eto-sterilizer-1.webp?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/zjbocon.com\/wp-content\/uploads\/2025\/09\/eto-sterilizer-1.webp?resize=700%2C400&ssl=1 2x, https:\/\/i0.wp.com\/zjbocon.com\/wp-content\/uploads\/2025\/09\/eto-sterilizer-1.webp?resize=1050%2C600&ssl=1 3x"},"classes":[]},{"id":2064,"url":"https:\/\/zjbocon.com\/?p=2064","url_meta":{"origin":2047,"position":3},"title":"OQ IN ETO STERILIZATION MACHINE","author":"Bocon Technical Team","date":"2024-10-31","format":false,"excerpt":"In OQ, the performance of the relevant auxiliary system should be determined and the software system should be tested by simulating the fault conditions.","rel":"","context":"In &quot;ETO STERILIZER&quot;","block_context":{"text":"ETO STERILIZER","link":"https:\/\/zjbocon.com\/?cat=133124"},"img":{"alt_text":"","src":"https:\/\/i0.wp.com\/zjbocon.com\/wp-content\/uploads\/2025\/09\/Ethylene-Oxide-Sterilizer-Installation-Guide-1-scaled.webp?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/zjbocon.com\/wp-content\/uploads\/2025\/09\/Ethylene-Oxide-Sterilizer-Installation-Guide-1-scaled.webp?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/zjbocon.com\/wp-content\/uploads\/2025\/09\/Ethylene-Oxide-Sterilizer-Installation-Guide-1-scaled.webp?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/zjbocon.com\/wp-content\/uploads\/2025\/09\/Ethylene-Oxide-Sterilizer-Installation-Guide-1-scaled.webp?resize=700%2C400&ssl=1 2x, https:\/\/i0.wp.com\/zjbocon.com\/wp-content\/uploads\/2025\/09\/Ethylene-Oxide-Sterilizer-Installation-Guide-1-scaled.webp?resize=1050%2C600&ssl=1 3x, https:\/\/i0.wp.com\/zjbocon.com\/wp-content\/uploads\/2025\/09\/Ethylene-Oxide-Sterilizer-Installation-Guide-1-scaled.webp?resize=1400%2C800&ssl=1 4x"},"classes":[]},{"id":2471,"url":"https:\/\/zjbocon.com\/?p=2471","url_meta":{"origin":2047,"position":4},"title":"Safety Requirements for Using Ethylene Oxide in sterilization","author":"Bocon Technical Team","date":"2024-12-23","format":false,"excerpt":"when Ethylene Oxide in sterilization chamber should be equipped with fire prevention facilities. Ethylene oxide cylinders should be stored separately in a dry, well-ventilated room, with strict prohibition of smoking and open flames. The lighting in the sterilization chamber should be explosion-proof, and any electrical appliances that may cause electric\u2026","rel":"","context":"In &quot;Company News&quot;","block_context":{"text":"Company News","link":"https:\/\/zjbocon.com\/?cat=133125"},"img":{"alt_text":"","src":"https:\/\/i0.wp.com\/zjbocon.com\/wp-content\/uploads\/2024\/10\/Electrical-Scale.png?resize=350%2C200","width":350,"height":200},"classes":[]},{"id":8776,"url":"https:\/\/zjbocon.com\/?p=8776","url_meta":{"origin":2047,"position":5},"title":"How to Test ETO Gas Sterilization Test Materials","author":"Bocon Technical Team","date":"2025-11-25","format":false,"excerpt":"When it comes to ETO gas sterilization, testing is an essential part of ensuring the effectiveness and safety of the sterilization process. ETO GAS STERILIZATION TEST MATERIALS","rel":"","context":"In &quot;Company News&quot;","block_context":{"text":"Company News","link":"https:\/\/zjbocon.com\/?cat=133125"},"img":{"alt_text":"","src":"https:\/\/i0.wp.com\/zjbocon.com\/wp-content\/uploads\/2025\/09\/ethylene-oxide-sterilization-68.webp?resize=350%2C200&ssl=1","width":350,"height":200},"classes":[]}],"_links":{"self":[{"href":"https:\/\/zjbocon.com\/index.php?rest_route=\/wp\/v2\/posts\/2047","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/zjbocon.com\/index.php?rest_route=\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/zjbocon.com\/index.php?rest_route=\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/zjbocon.com\/index.php?rest_route=\/wp\/v2\/users\/234312599"}],"replies":[{"embeddable":true,"href":"https:\/\/zjbocon.com\/index.php?rest_route=%2Fwp%2Fv2%2Fcomments&post=2047"}],"version-history":[{"count":10,"href":"https:\/\/zjbocon.com\/index.php?rest_route=\/wp\/v2\/posts\/2047\/revisions"}],"predecessor-version":[{"id":8903,"href":"https:\/\/zjbocon.com\/index.php?rest_route=\/wp\/v2\/posts\/2047\/revisions\/8903"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/zjbocon.com\/index.php?rest_route=\/wp\/v2\/media\/8475"}],"wp:attachment":[{"href":"https:\/\/zjbocon.com\/index.php?rest_route=%2Fwp%2Fv2%2Fmedia&parent=2047"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/zjbocon.com\/index.php?rest_route=%2Fwp%2Fv2%2Fcategories&post=2047"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/zjbocon.com\/index.php?rest_route=%2Fwp%2Fv2%2Ftags&post=2047"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}