{"id":2471,"date":"2024-12-23T09:49:40","date_gmt":"2024-12-23T01:49:40","guid":{"rendered":"https:\/\/zjbocon.com\/?p=2471"},"modified":"2025-10-01T19:14:06","modified_gmt":"2025-10-01T11:14:06","slug":"safety-requirements-for-using-ethylene-oxide-in-sterilization","status":"publish","type":"post","link":"https:\/\/zjbocon.com\/?p=2471","title":{"rendered":"Safety Requirements for Using Ethylene Oxide in sterilization"},"content":{"rendered":"\n<div class=\"wp-block-uagb-image uagb-block-3a59f9d8 wp-block-uagb-image--layout-default wp-block-uagb-image--effect-static wp-block-uagb-image--align-none\"><figure class=\"wp-block-uagb-image__figure\"><img loading=\"lazy\" decoding=\"async\" src=\"https:\/\/zjbocon.com\/wp-content\/uploads\/2024\/10\/Electrical-Scale.png\" alt=\"\" class=\"uag-image-1673\" width=\"255\" height=\"569\" title=\"Electrical Scale\" role=\"img\" \><\/figure><\/div>\n\n\n\n<ol class=\"wp-block-list\">\n<li>በማምከን ክፍል ውስጥ ያለው ኤቲሊን ኦክሳይድ የእሳት አደጋ መከላከያ መሳሪያዎችን ሲይዝ.<\/li>\n\n\n\n<li>ኤቲሊን ኦክሳይድ ሲሊንደሮች ማጨስን እና ክፍት እሳትን በጥብቅ በመከልከል በደረቅ እና በደንብ በሚተነፍሰው ክፍል ውስጥ ተለይተው መቀመጥ አለባቸው።<\/li>\n\n\n\n<li>በማምከን ክፍሉ ውስጥ ያለው መብራት ፍንዳታ-ተከላካይ መሆን አለበት, እና ማንኛውም የኤሌክትሪክ ብልጭታ ሊያስከትሉ የሚችሉ የኤሌክትሪክ ዕቃዎች መወገድ አለባቸው. ክፍት ነበልባሎች በጥብቅ የተከለከሉ ናቸው።<\/li>\n\n\n\n<li>እያንዳንዱን የንጥል ዓይነት ከማምከን በፊት መለኪያዎቹ በብሔራዊ ደረጃ GB18279-2000 መረጋገጥ አለባቸው።<\/li>\n\n\n\n<li>የማምከያው መቆጣጠሪያ ክፍል ከዋናው ክፍል ተለይቶ መጫን አለበት (ሥዕላዊ መግለጫ D.1 ይመልከቱ).<\/li>\n\n\n\n<li>የመፈናቀሉ (የማፍሰሻ) ደረጃ ከተጠናቀቀ በኋላ, የተጸዳዱት እቃዎች በታሸገው የማምከን ክፍል ውስጥ ከ 15 ደቂቃዎች በላይ መቆየት የለባቸውም. አለበለዚያ በሩን ከመክፈትዎ በፊት የመፈናቀሉ ደረጃ መደገም አለበት.<\/li>\n\n\n\n<li>በማምከን ውስጥ ያለው ኤቲሊን ኦክሳይድ ከተጠናቀቀ በኋላ, የመፈናቀያው አየር በተገቢው የማምከን ኦፕሬሽን ደንቦች መሰረት መደረግ አለበት. እቃዎችን ለማስወገድ በሩን ከመክፈትዎ በፊት የአየር ማናፈሻን ለማረጋገጥ የአክሲል ማራገቢያ ማብራት አለበት. በማምከን ክፍሉ ውስጥ ጎጂ የሆኑ ቀሪ ጋዞች እንዳይጋለጡ በሩን ከከፈቱ በኋላ እቃዎቹን ወዲያውኑ አይውጡ.<\/li>\n\n\n\n<li><strong>የመድኃኒት ማንቂያ<\/strong> መሰጠት ያለበት የመድሃኒት መጠን ላይ በመመርኮዝ ግፊቱን ወይም ክብደቱን ያስቀምጡ. የሚፈለገው መጠን ሲደርስ፣ የሚሰማ ማንቂያ ይሰማል። በዚህ ጊዜ ኦፕሬተሩ ወዲያውኑ የመድሃኒት ጠርሙሱን እና ዋናውን የዶዚንግ ቫልቭ መዘጋት አለበት.<\/li>\n\n\n\n<li>የኤትሊን ኦክሳይድ ድብልቅ ጋዞች ተጠቃሚዎች የግፊት መቆጣጠሪያ (በተጠቃሚ የተጫነ) በመድሀኒት ጠርሙሱ መውጫ ላይ የጠርሙስ መውጫ ግፊትን ከ 0.4 MPa በታች ለመቀነስ እና ከፍተኛ ግፊት በዶሲንግ ቧንቧው ውስጥ እንዳይፈስ ይከላከላል።<\/li>\n\n\n\n<li>የስቴሪየንት አቅርቦት ስርዓት ማንኛውንም ክፍል ከማላቀቅ ወይም ከመክፈቱ በፊት ስርዓቱን ማጽዳት አስፈላጊ ነው (ከጋዝ ማጠራቀሚያ አቅርቦት ስርዓት በስተቀር).<\/li>\n\n\n\n<li>የማምከን ውስጥ በር ማኅተም gasket የአየር ግፊት የማምከን ሂደት ወቅት 0.45 MPa በታች ቢወድቅ, ወደ ጎማ ማኅተም ያለውን የአየር አቅርቦት መዘጋት አለበት, እና የመጠባበቂያ ግፊት ምንጭ መያያዝ አለበት የጎማ ማኅተም ከ 0.45 MPa ግፊት ያለው መሆኑን ለማረጋገጥ. በተመሳሳይ ጊዜ, የኤትሊን ኦክሳይድ ፍሳሽ አያያዝ ሂደት የማምከን ክፍሉን ለመልቀቅ እና ለማጽዳት መንቃት አለበት. ከዚያም የመጀመሪያውን የአየር ምንጭ ለመመለስ እርምጃዎች መወሰድ አለባቸው.<\/li>\n\n\n\n<li>የሥራ ቦታ የአየር ማናፈሻ ስርዓቱ ካልተሳካ, መሳሪያው መዘጋት እና እንደገና መጀመር የለበትም. የማምከን ተወካዩ ቀድሞውኑ ወደ ክፍሉ ውስጥ በገባበት ጊዜ አለመሳካቱ ከተከሰተ ኦፕሬተሩ ወደ ክፍሉ ውስጥ መግባት ያለበት የንጽሕና ማስወገጃ እና የፍሳሽ ማስወገጃ ሂደቶች ሙሉ በሙሉ ከተጠናቀቀ በኋላ ብቻ ነው.<\/li>\n\n\n\n<li>ከእያንዳንዱ የሥራ ዑደት በኋላ የኤትሊን ኦክሳይድ የቧንቧ መስመር ስርዓት ማጽዳት አለበት. የጽዳት ሚዲያ ውሃን፣ የተጨመቀ አየር ወይም እንፋሎትን ሊያካትት ይችላል። ተጠቃሚው የማምከን ጋዝ ሊጠራቀም በሚችልባቸው አካባቢዎች፣ ለምሳሌ በማምከያው በር አጠገብ፣ የጸዳ እቃዎች ማከማቻ ቦታ እና የንጽሕና ማከማቻ ቦታ ላይ የአካባቢ የጭስ ማውጫ ዘዴዎችን መጫን አለበት። የጭስ ማውጫው ስርዓት አደጋን ሊያስከትሉ የሚችሉ ንጥረ ነገሮችን ማፍሰስ የለበትም.<\/li>\n<\/ol>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>ማስታወሻ፡-<\/strong> መሣሪያው በተለመደው አሠራር፣ ብልሽት ወይም የጥገና ሁኔታ ላይ ቢሆንም፣ ሠራተኞች ወደ ስቴሪዘር ክፍል መግባት ካለባቸው፣ በሩ ወደ መሬት መውረድ ወይም መደገፍ አለበት። በሩ እንደተቆለፈ እና ሊዘጋ እንደማይችል መረጋገጥ አለበት. ሰራተኞቹ ወደ ክፍሉ ከመግባታቸው በፊት ቁልፉን መውሰድ ወይም በጥንቃቄ ማከማቸት አለባቸው።<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"h-contact\">ተገናኝ<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">ስልክ፡<a href=\"https:\/\/wa.me\/8619975258603\">+8619975258603<\/a><\/p>\n\n\n\n<p class=\"wp-block-paragraph\">ኢሜይል፡-<a href=\"mailto:hayley@hzbocon.com\">hayley@hzbocon.com<\/a><\/p>\n\n\n\n<p class=\"wp-block-paragraph\">የአካባቢ ቦታ፡ ክፍል 1202፣ ካይቶንግ ዞንግክሲን፣ ዢያሻ አውራጃ፣ ሃንግዙ ከተማ፣ ዢጂያንግ ግዛት፣ ቻይና<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">ድህረገፅ፥<a href=\"https:\/\/www.hzbocon.com\/\">hzbocon.com<\/a><a href=\"https:\/\/zjbocon.com\/\">&nbsp;zjbocon.com<\/a><\/p>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"h-know-more-about-us\">ስለእኛ የበለጠ ይወቁ<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\"><a href=\"https:\/\/zjbocon.com\/sterilization-for-spice\/\">ኢቶ፣ ጋማ እና የእንፋሎት ማምከንን ለቅመማ ቅመም ማወዳደር<\/a><\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><a href=\"https:\/\/zjbocon.com\/understanding-eto-sterilizer-performance-keys-to-efficiency\/\">የETO Sterilizer አፈጻጸምን መረዳት፡ የውጤታማነት ቁልፎች<\/a><\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><a href=\"https:\/\/zjbocon.com\/ethylene-oxide-leak-handling-when-using-eto-sterilizer\/\">ኢቶ ስቴሪላይዘርን ሲጠቀሙ የኤትሊን ኦክሳይድ ሌክ አያያዝ<\/a><\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><a href=\"https:\/\/zjbocon.com\/safety-requirements-for-using-ethylene-oxide-in-sterilization\/\">በማምከን ውስጥ ኤቲሊን ኦክሳይድን ለመጠቀም የደህንነት መስፈርቶች<\/a><\/p>\n","protected":false},"excerpt":{"rendered":"<p>Note: Regardless of whether the equipment is in normal operation, malfunction, or maintenance state, if personnel need to enter the [&hellip;]<\/p>\n","protected":false},"author":234312599,"featured_media":1686,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_uag_custom_page_level_css":"","site-sidebar-layout":"default","site-content-layout":"","ast-site-content-layout":"default","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","ast-disable-related-posts":"","theme-transparent-header-meta":"","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"set","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"_jetpack_newsletter_access":"","_jetpack_dont_email_post_to_subs":false,"_jetpack_newsletter_tier_id":0,"_jetpack_memberships_contains_paywalled_content":false,"_jetpack_feature_clip_id":0,"_jetpack_memberships_contains_paid_content":false,"footnotes":"","jetpack_publicize_message":"","jetpack_publicize_feature_enabled":true,"jetpack_social_post_already_shared":false,"jetpack_social_options":{"image_generator_settings":{"template":"highway","enabled":false},"version":2},"jetpack_post_was_ever_published":false},"categories":[133125,133124],"tags":[],"class_list":["post-2471","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-company-news","category-eto-sterilizer"],"yoast_head":"<!-- This site is optimized with the Yoast SEO Premium plugin v27.2 (Yoast SEO v28.0) - https:\/\/yoast.com\/product\/yoast-seo-premium-wordpress\/ -->\n<title>በማምከን ውስጥ ኤቲሊን ኦክሳይድን ለመጠቀም የደህንነት መስፈርቶች - ETO STERILIZER<\/title>\n<meta name=\"description\" content=\"The ethylene oxide gas(Ethylene Oxide in sterilization) for the sterilizer should be supplied by dedicated steel cylinders.\" \>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \>\n<link rel=\"canonical\" href=\"https:\/\/zjbocon.com\/?p=2471\" \>\n<meta property=\"og:locale\" content=\"en_US\" \>\n<meta property=\"og:type\" content=\"article\" \>\n<meta property=\"og:title\" content=\"Safety Requirements for Using Ethylene Oxide in sterilization\" \>\n<meta property=\"og:description\" content=\"The ethylene oxide gas(Ethylene Oxide in sterilization) for the sterilizer should be supplied by dedicated steel cylinders.\" \>\n<meta property=\"og:url\" content=\"https:\/\/zjbocon.com\/?p=2471\" \>\n<meta property=\"og:site_name\" content=\"ETO STERILIZER\" \>\n<meta property=\"article:publisher\" content=\"https:\/\/www.facebook.com\/profile.php?id=100088482339878\" \>\n<meta property=\"article:author\" content=\"https:\/\/www.facebook.com\/profile.php?id=100088482339878\" \>\n<meta property=\"article:published_time\" content=\"2024-12-23T01:49:40+00:00\" \>\n<meta property=\"article:modified_time\" content=\"2025-10-01T11:14:06+00:00\" \>\n<meta property=\"og:image\" content=\"https:\/\/zjbocon.com\/wp-content\/uploads\/2024\/10\/Electrical-Scale.webp\" \>\n\t<meta property=\"og:image:width\" content=\"255\" \>\n\t<meta property=\"og:image:height\" content=\"569\" \>\n\t<meta property=\"og:image:type\" content=\"image\/webp\" \>\n<meta name=\"author\" content=\"Bocon Technical Team\" \>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \>\n<meta name=\"twitter:creator\" content=\"@BoconAnd\" \>\n<meta name=\"twitter:site\" content=\"@BoconAnd\" \>\n<meta name=\"twitter:label1\" content=\"Written by\" \>\n\t<meta name=\"twitter:data1\" content=\"Bocon Technical Team\" \>\n\t<meta name=\"twitter:label2\" content=\"Est. reading time\" \>\n\t<meta name=\"twitter:data2\" content=\"4 minutes\" \>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\\\/\\\/zjbocon.com\\\/?p=2471#article\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/zjbocon.com\\\/?p=2471\"},\"author\":{\"name\":\"Bocon Technical Team\",\"@id\":\"https:\\\/\\\/zjbocon.com\\\/#\\\/schema\\\/person\\\/f12be028b8ae9843a4396dcc8012b425\"},\"headline\":\"Safety Requirements for Using Ethylene Oxide in sterilization\",\"datePublished\":\"2024-12-23T01:49:40+00:00\",\"dateModified\":\"2025-10-01T11:14:06+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/zjbocon.com\\\/?p=2471\"},\"wordCount\":619,\"commentCount\":0,\"publisher\":{\"@id\":\"https:\\\/\\\/zjbocon.com\\\/#organization\"},\"image\":{\"@id\":\"https:\\\/\\\/zjbocon.com\\\/?p=2471#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/zjbocon.com\\\/wp-content\\\/uploads\\\/2024\\\/10\\\/Electrical-Scale.webp\",\"articleSection\":[\"Company News\",\"ETO STERILIZER\"],\"inLanguage\":\"am\",\"potentialAction\":[{\"@type\":\"CommentAction\",\"name\":\"Comment\",\"target\":[\"https:\\\/\\\/zjbocon.com\\\/?p=2471#respond\"]}]},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/zjbocon.com\\\/?p=2471\",\"url\":\"https:\\\/\\\/zjbocon.com\\\/?p=2471\",\"name\":\"Safety Requirements for Using Ethylene Oxide in sterilization - ETO STERILIZER\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/zjbocon.com\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/zjbocon.com\\\/?p=2471#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/zjbocon.com\\\/?p=2471#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/zjbocon.com\\\/wp-content\\\/uploads\\\/2024\\\/10\\\/Electrical-Scale.webp\",\"datePublished\":\"2024-12-23T01:49:40+00:00\",\"dateModified\":\"2025-10-01T11:14:06+00:00\",\"description\":\"The ethylene oxide gas(Ethylene Oxide in sterilization) for the sterilizer should be supplied by dedicated ethylene oxide steel cylinders.\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/zjbocon.com\\\/?p=2471#breadcrumb\"},\"inLanguage\":\"am\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/zjbocon.com\\\/?p=2471\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"am\",\"@id\":\"https:\\\/\\\/zjbocon.com\\\/?p=2471#primaryimage\",\"url\":\"https:\\\/\\\/zjbocon.com\\\/wp-content\\\/uploads\\\/2024\\\/10\\\/Electrical-Scale.webp\",\"contentUrl\":\"https:\\\/\\\/zjbocon.com\\\/wp-content\\\/uploads\\\/2024\\\/10\\\/Electrical-Scale.webp\",\"width\":255,\"height\":569,\"caption\":\"eo gas\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/zjbocon.com\\\/?p=2471#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/zjbocon.com\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Safety Requirements for Using Ethylene Oxide in sterilization\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/zjbocon.com\\\/#website\",\"url\":\"https:\\\/\\\/zjbocon.com\\\/\",\"name\":\"ETO STERILIZER\",\"description\":\"One-stop Solution Supplier of Ethylene Oxide Sterilization\",\"publisher\":{\"@id\":\"https:\\\/\\\/zjbocon.com\\\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/zjbocon.com\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"am\"},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/zjbocon.com\\\/#organization\",\"name\":\"ETO STERILIZER\",\"url\":\"https:\\\/\\\/zjbocon.com\\\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"am\",\"@id\":\"https:\\\/\\\/zjbocon.com\\\/#\\\/schema\\\/logo\\\/image\\\/\",\"url\":\"https:\\\/\\\/zjbocon.com\\\/wp-content\\\/uploads\\\/2024\\\/10\\\/logo-1.webp\",\"contentUrl\":\"https:\\\/\\\/zjbocon.com\\\/wp-content\\\/uploads\\\/2024\\\/10\\\/logo-1.webp\",\"width\":180,\"height\":60,\"caption\":\"ETO STERILIZER\"},\"image\":{\"@id\":\"https:\\\/\\\/zjbocon.com\\\/#\\\/schema\\\/logo\\\/image\\\/\"},\"sameAs\":[\"https:\\\/\\\/www.facebook.com\\\/profile.php?id=100088482339878\",\"https:\\\/\\\/x.com\\\/BoconAnd\",\"https:\\\/\\\/www.linkedin.com\\\/in\\\/--06a221139\\\/\"]},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/zjbocon.com\\\/#\\\/schema\\\/person\\\/f12be028b8ae9843a4396dcc8012b425\",\"name\":\"Bocon Technical Team\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"am\",\"@id\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/d7a825658be227f26b237e519f8541e05aabc9ff27b8eec4544a233a48c53be0?s=96&d=identicon&r=g\",\"url\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/d7a825658be227f26b237e519f8541e05aabc9ff27b8eec4544a233a48c53be0?s=96&d=identicon&r=g\",\"contentUrl\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/d7a825658be227f26b237e519f8541e05aabc9ff27b8eec4544a233a48c53be0?s=96&d=identicon&r=g\",\"caption\":\"Bocon Technical Team\"},\"sameAs\":[\"https:\\\/\\\/zjbocon.com\\\/\",\"https:\\\/\\\/www.facebook.com\\\/profile.php?id=100088482339878\",\"https:\\\/\\\/www.linkedin.com\\\/in\\\/\\\/hayley--968190269\\\/\"],\"url\":\"https:\\\/\\\/zjbocon.com\\\/?author=234312599\"}]}<\/script>\n<!-- \/ Yoast SEO Premium plugin. -->","yoast_head_json":{"title":"Safety Requirements for Using Ethylene Oxide in sterilization - ETO STERILIZER","description":"The ethylene oxide gas(Ethylene Oxide in sterilization) for the sterilizer should be supplied by dedicated ethylene oxide steel cylinders.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/zjbocon.com\/?p=2471","og_locale":"en_US","og_type":"article","og_title":"Safety Requirements for Using Ethylene Oxide in sterilization","og_description":"The ethylene oxide gas(Ethylene Oxide in sterilization) for the sterilizer should be supplied by dedicated ethylene oxide steel cylinders.","og_url":"https:\/\/zjbocon.com\/?p=2471","og_site_name":"ETO STERILIZER","article_publisher":"https:\/\/www.facebook.com\/profile.php?id=100088482339878","article_author":"https:\/\/www.facebook.com\/profile.php?id=100088482339878","article_published_time":"2024-12-23T01:49:40+00:00","article_modified_time":"2025-10-01T11:14:06+00:00","og_image":[{"width":255,"height":569,"url":"https:\/\/zjbocon.com\/wp-content\/uploads\/2024\/10\/Electrical-Scale.webp","type":"image\/webp"}],"author":"Bocon Technical Team","twitter_card":"summary_large_image","twitter_creator":"@BoconAnd","twitter_site":"@BoconAnd","twitter_misc":{"Written by":"Bocon Technical Team","Est. reading time":"4 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/zjbocon.com\/?p=2471#article","isPartOf":{"@id":"https:\/\/zjbocon.com\/?p=2471"},"author":{"name":"Bocon Technical Team","@id":"https:\/\/zjbocon.com\/#\/schema\/person\/f12be028b8ae9843a4396dcc8012b425"},"headline":"Safety Requirements for Using Ethylene Oxide in sterilization","datePublished":"2024-12-23T01:49:40+00:00","dateModified":"2025-10-01T11:14:06+00:00","mainEntityOfPage":{"@id":"https:\/\/zjbocon.com\/?p=2471"},"wordCount":619,"commentCount":0,"publisher":{"@id":"https:\/\/zjbocon.com\/#organization"},"image":{"@id":"https:\/\/zjbocon.com\/?p=2471#primaryimage"},"thumbnailUrl":"https:\/\/zjbocon.com\/wp-content\/uploads\/2024\/10\/Electrical-Scale.webp","articleSection":["Company News","ETO STERILIZER"],"inLanguage":"am","potentialAction":[{"@type":"CommentAction","name":"Comment","target":["https:\/\/zjbocon.com\/?p=2471#respond"]}]},{"@type":"WebPage","@id":"https:\/\/zjbocon.com\/?p=2471","url":"https:\/\/zjbocon.com\/?p=2471","name":"Safety Requirements for Using Ethylene Oxide in sterilization - ETO STERILIZER","isPartOf":{"@id":"https:\/\/zjbocon.com\/#website"},"primaryImageOfPage":{"@id":"https:\/\/zjbocon.com\/?p=2471#primaryimage"},"image":{"@id":"https:\/\/zjbocon.com\/?p=2471#primaryimage"},"thumbnailUrl":"https:\/\/zjbocon.com\/wp-content\/uploads\/2024\/10\/Electrical-Scale.webp","datePublished":"2024-12-23T01:49:40+00:00","dateModified":"2025-10-01T11:14:06+00:00","description":"The ethylene oxide gas(Ethylene Oxide in sterilization) for the sterilizer should be supplied by dedicated ethylene oxide steel cylinders.","breadcrumb":{"@id":"https:\/\/zjbocon.com\/?p=2471#breadcrumb"},"inLanguage":"am","potentialAction":[{"@type":"ReadAction","target":["https:\/\/zjbocon.com\/?p=2471"]}]},{"@type":"ImageObject","inLanguage":"am","@id":"https:\/\/zjbocon.com\/?p=2471#primaryimage","url":"https:\/\/zjbocon.com\/wp-content\/uploads\/2024\/10\/Electrical-Scale.webp","contentUrl":"https:\/\/zjbocon.com\/wp-content\/uploads\/2024\/10\/Electrical-Scale.webp","width":255,"height":569,"caption":"eo gas"},{"@type":"BreadcrumbList","@id":"https:\/\/zjbocon.com\/?p=2471#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/zjbocon.com\/"},{"@type":"ListItem","position":2,"name":"Safety Requirements for Using Ethylene Oxide in sterilization"}]},{"@type":"WebSite","@id":"https:\/\/zjbocon.com\/#website","url":"https:\/\/zjbocon.com\/","name":"ETO STERILIZER","description":"One-stop Solution Supplier of Ethylene Oxide Sterilization","publisher":{"@id":"https:\/\/zjbocon.com\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/zjbocon.com\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"am"},{"@type":"Organization","@id":"https:\/\/zjbocon.com\/#organization","name":"ETO STERILIZER","url":"https:\/\/zjbocon.com\/","logo":{"@type":"ImageObject","inLanguage":"am","@id":"https:\/\/zjbocon.com\/#\/schema\/logo\/image\/","url":"https:\/\/zjbocon.com\/wp-content\/uploads\/2024\/10\/logo-1.webp","contentUrl":"https:\/\/zjbocon.com\/wp-content\/uploads\/2024\/10\/logo-1.webp","width":180,"height":60,"caption":"ETO STERILIZER"},"image":{"@id":"https:\/\/zjbocon.com\/#\/schema\/logo\/image\/"},"sameAs":["https:\/\/www.facebook.com\/profile.php?id=100088482339878","https:\/\/x.com\/BoconAnd","https:\/\/www.linkedin.com\/in\/--06a221139\/"]},{"@type":"Person","@id":"https:\/\/zjbocon.com\/#\/schema\/person\/f12be028b8ae9843a4396dcc8012b425","name":"Bocon Technical Team","image":{"@type":"ImageObject","inLanguage":"am","@id":"https:\/\/secure.gravatar.com\/avatar\/d7a825658be227f26b237e519f8541e05aabc9ff27b8eec4544a233a48c53be0?s=96&d=identicon&r=g","url":"https:\/\/secure.gravatar.com\/avatar\/d7a825658be227f26b237e519f8541e05aabc9ff27b8eec4544a233a48c53be0?s=96&d=identicon&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/d7a825658be227f26b237e519f8541e05aabc9ff27b8eec4544a233a48c53be0?s=96&d=identicon&r=g","caption":"Bocon Technical Team"},"sameAs":["https:\/\/zjbocon.com\/","https:\/\/www.facebook.com\/profile.php?id=100088482339878","https:\/\/www.linkedin.com\/in\/\/hayley--968190269\/"],"url":"https:\/\/zjbocon.com\/?author=234312599"}]}},"jetpack_publicize_connections":[],"jetpack_featured_media_url":"https:\/\/zjbocon.com\/wp-content\/uploads\/2024\/10\/Electrical-Scale.webp","uagb_featured_image_src":{"full":["https:\/\/zjbocon.com\/wp-content\/uploads\/2024\/10\/Electrical-Scale.webp",255,569,false],"thumbnail":["https:\/\/zjbocon.com\/wp-content\/uploads\/2024\/10\/Electrical-Scale-150x150.webp",150,150,true],"medium":["https:\/\/zjbocon.com\/wp-content\/uploads\/2024\/10\/Electrical-Scale-134x300.webp",134,300,true],"medium_large":["https:\/\/zjbocon.com\/wp-content\/uploads\/2024\/10\/Electrical-Scale.webp",255,569,false],"large":["https:\/\/zjbocon.com\/wp-content\/uploads\/2024\/10\/Electrical-Scale.webp",255,569,false],"1536x1536":["https:\/\/zjbocon.com\/wp-content\/uploads\/2024\/10\/Electrical-Scale.webp",255,569,false],"2048x2048":["https:\/\/zjbocon.com\/wp-content\/uploads\/2024\/10\/Electrical-Scale.webp",255,569,false],"woocommerce_thumbnail":["https:\/\/zjbocon.com\/wp-content\/uploads\/2024\/10\/Electrical-Scale.webp",255,569,false],"woocommerce_single":["https:\/\/zjbocon.com\/wp-content\/uploads\/2024\/10\/Electrical-Scale.webp",255,569,false],"woocommerce_gallery_thumbnail":["https:\/\/zjbocon.com\/wp-content\/uploads\/2024\/10\/Electrical-Scale-100x100.webp",100,100,true]},"uagb_author_info":{"display_name":"Bocon Technical Team","author_link":"https:\/\/zjbocon.com\/?author=234312599"},"uagb_comment_info":0,"uagb_excerpt":"Note: Regardless of whether the equipment is in normal operation, malfunction, or maintenance state, if personnel need to enter the [&hellip;]","jetpack_likes_enabled":true,"jetpack_sharing_enabled":true,"jetpack_shortlink":"https:\/\/wp.me\/pgZDV6-DR","jetpack-related-posts":[{"id":2476,"url":"https:\/\/zjbocon.com\/?p=2476","url_meta":{"origin":2471,"position":0},"title":"Ethylene Oxide Leak Handling when using eto sterilizer","author":"Bocon Technical Team","date":"2024-12-23","format":false,"excerpt":"If a leak is detected in the eto sterilizer dosing pipeline during the administration process, immediately close the medication bottle, switch and the dosing valve on the main unit. Turn on the axial fan to ensure proper ventilation, and then proceed with repairs.","rel":"","context":"In &quot;Company News&quot;","block_context":{"text":"Company News","link":"https:\/\/zjbocon.com\/?cat=133125"},"img":{"alt_text":"","src":"https:\/\/i0.wp.com\/zjbocon.com\/wp-content\/uploads\/2025\/09\/ethylene-oxide-sterilization-19-scaled.webp?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/zjbocon.com\/wp-content\/uploads\/2025\/09\/ethylene-oxide-sterilization-19-scaled.webp?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/zjbocon.com\/wp-content\/uploads\/2025\/09\/ethylene-oxide-sterilization-19-scaled.webp?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/zjbocon.com\/wp-content\/uploads\/2025\/09\/ethylene-oxide-sterilization-19-scaled.webp?resize=700%2C400&ssl=1 2x, https:\/\/i0.wp.com\/zjbocon.com\/wp-content\/uploads\/2025\/09\/ethylene-oxide-sterilization-19-scaled.webp?resize=1050%2C600&ssl=1 3x, https:\/\/i0.wp.com\/zjbocon.com\/wp-content\/uploads\/2025\/09\/ethylene-oxide-sterilization-19-scaled.webp?resize=1400%2C800&ssl=1 4x"},"classes":[]},{"id":8958,"url":"https:\/\/zjbocon.com\/?p=8958","url_meta":{"origin":2471,"position":1},"title":"Understanding What is ETO Sterilizers: A Comprehensive Guide","author":"Bocon Technical Team","date":"2025-12-16","format":false,"excerpt":"Discover the essentials of ETO sterilizers and ethylene oxide sterilization, ensuring the highest hygiene standards in healthcare and beyond.","rel":"","context":"In &quot;Company News&quot;","block_context":{"text":"Company News","link":"https:\/\/zjbocon.com\/?cat=133125"},"img":{"alt_text":"","src":"https:\/\/i0.wp.com\/zjbocon.com\/wp-content\/uploads\/2024\/11\/eto-sterilizer-hzbocon-3.png?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/zjbocon.com\/wp-content\/uploads\/2024\/11\/eto-sterilizer-hzbocon-3.png?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/zjbocon.com\/wp-content\/uploads\/2024\/11\/eto-sterilizer-hzbocon-3.png?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/zjbocon.com\/wp-content\/uploads\/2024\/11\/eto-sterilizer-hzbocon-3.png?resize=700%2C400&ssl=1 2x, https:\/\/i0.wp.com\/zjbocon.com\/wp-content\/uploads\/2024\/11\/eto-sterilizer-hzbocon-3.png?resize=1050%2C600&ssl=1 3x"},"classes":[]},{"id":3093,"url":"https:\/\/zjbocon.com\/?p=3093","url_meta":{"origin":2471,"position":2},"title":"Introduction to Ethylene Oxide Sterilizers","author":"Bocon Technical Team","date":"2025-02-05","format":false,"excerpt":"Discover how ethylene oxide sterilizers work, their applications, benefits, and safety considerations. Learn why they are essential for medical and industrial sterilization.","rel":"","context":"In &quot;Company News&quot;","block_context":{"text":"Company News","link":"https:\/\/zjbocon.com\/?cat=133125"},"img":{"alt_text":"","src":"https:\/\/i0.wp.com\/zjbocon.com\/wp-content\/uploads\/2024\/11\/ethylene-oxide-sterilization-21.webp?resize=350%2C200","width":350,"height":200},"classes":[]},{"id":2453,"url":"https:\/\/zjbocon.com\/?p=2453","url_meta":{"origin":2471,"position":3},"title":"Microbial Killing Performance of Ethylene Oxide Sterilizers","author":"Bocon Technical Team","date":"2024-12-20","format":false,"excerpt":"Note 1: The Ethylene Oxide sterilization conditions must be obtained through validation confirmation and should be verified with monitoring and routine control during each sterilization cycle. The requirements for validation and routine control are outlined in GB 18279. Note 2: This testing method is also applicable to A class Ethylene\u2026","rel":"","context":"In &quot;Company News&quot;","block_context":{"text":"Company News","link":"https:\/\/zjbocon.com\/?cat=133125"},"img":{"alt_text":"eto sterilizer","src":"https:\/\/i0.wp.com\/zjbocon.com\/wp-content\/uploads\/2024\/10\/banner__.webp?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/zjbocon.com\/wp-content\/uploads\/2024\/10\/banner__.webp?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/zjbocon.com\/wp-content\/uploads\/2024\/10\/banner__.webp?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/zjbocon.com\/wp-content\/uploads\/2024\/10\/banner__.webp?resize=700%2C400&ssl=1 2x"},"classes":[]},{"id":2448,"url":"https:\/\/zjbocon.com\/?p=2448","url_meta":{"origin":2471,"position":4},"title":"eto sterilization Chamber Temperature Distribution Testing","author":"Bocon Technical Team","date":"2024-12-20","format":false,"excerpt":"The temperature of representative areas on the inner surfaces should be measured and recorded using temperature recording instruments that comply with the requirements of Appendix B.","rel":"","context":"In &quot;Company News&quot;","block_context":{"text":"Company News","link":"https:\/\/zjbocon.com\/?cat=133125"},"img":{"alt_text":"","src":"https:\/\/i0.wp.com\/zjbocon.com\/wp-content\/uploads\/2025\/09\/ethylene-oxide-sterilization-54.webp?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/zjbocon.com\/wp-content\/uploads\/2025\/09\/ethylene-oxide-sterilization-54.webp?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/zjbocon.com\/wp-content\/uploads\/2025\/09\/ethylene-oxide-sterilization-54.webp?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/zjbocon.com\/wp-content\/uploads\/2025\/09\/ethylene-oxide-sterilization-54.webp?resize=700%2C400&ssl=1 2x, https:\/\/i0.wp.com\/zjbocon.com\/wp-content\/uploads\/2025\/09\/ethylene-oxide-sterilization-54.webp?resize=1050%2C600&ssl=1 3x"},"classes":[]},{"id":2439,"url":"https:\/\/zjbocon.com\/?p=2439","url_meta":{"origin":2471,"position":5},"title":"Preparatory Work Before eto Sterilization","author":"Bocon Technical Team","date":"2024-12-17","format":false,"excerpt":"Appearance Inspection: Check the main unit, control rack, and electrical control cabinet for any damage on the surface.","rel":"","context":"In &quot;Company News&quot;","block_context":{"text":"Company News","link":"https:\/\/zjbocon.com\/?cat=133125"},"img":{"alt_text":"","src":"https:\/\/i0.wp.com\/zjbocon.com\/wp-content\/uploads\/2025\/09\/sterilizer-station-design-2.webp?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/zjbocon.com\/wp-content\/uploads\/2025\/09\/sterilizer-station-design-2.webp?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/zjbocon.com\/wp-content\/uploads\/2025\/09\/sterilizer-station-design-2.webp?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/zjbocon.com\/wp-content\/uploads\/2025\/09\/sterilizer-station-design-2.webp?resize=700%2C400&ssl=1 2x"},"classes":[]}],"_links":{"self":[{"href":"https:\/\/zjbocon.com\/index.php?rest_route=\/wp\/v2\/posts\/2471","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/zjbocon.com\/index.php?rest_route=\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/zjbocon.com\/index.php?rest_route=\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/zjbocon.com\/index.php?rest_route=\/wp\/v2\/users\/234312599"}],"replies":[{"embeddable":true,"href":"https:\/\/zjbocon.com\/index.php?rest_route=%2Fwp%2Fv2%2Fcomments&post=2471"}],"version-history":[{"count":5,"href":"https:\/\/zjbocon.com\/index.php?rest_route=\/wp\/v2\/posts\/2471\/revisions"}],"predecessor-version":[{"id":2499,"href":"https:\/\/zjbocon.com\/index.php?rest_route=\/wp\/v2\/posts\/2471\/revisions\/2499"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/zjbocon.com\/index.php?rest_route=\/wp\/v2\/media\/1686"}],"wp:attachment":[{"href":"https:\/\/zjbocon.com\/index.php?rest_route=%2Fwp%2Fv2%2Fmedia&parent=2471"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/zjbocon.com\/index.php?rest_route=%2Fwp%2Fv2%2Fcategories&post=2471"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/zjbocon.com\/index.php?rest_route=%2Fwp%2Fv2%2Ftags&post=2471"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}