{"id":8915,"date":"2025-12-05T14:57:48","date_gmt":"2025-12-05T06:57:48","guid":{"rendered":"https:\/\/zjbocon.com\/?p=8915"},"modified":"2025-12-24T09:59:03","modified_gmt":"2025-12-24T01:59:03","slug":"sterilization-compatibility-table-for-medical-packaging-materials","status":"publish","type":"post","link":"https:\/\/zjbocon.com\/?p=8915","title":{"rendered":"Sterilization Compatibility Table for Medical Packaging Materials"},"content":{"rendered":"\n<div class=\"wp-block-uagb-image uagb-block-d2618dbf wp-block-uagb-image--layout-default wp-block-uagb-image--effect-static wp-block-uagb-image--align-none\"><figure class=\"wp-block-uagb-image__figure\"><img loading=\"lazy\" decoding=\"async\" src=\"https:\/\/zjbocon.com\/wp-content\/uploads\/2024\/11\/eto-sterilizer-hzbocon-6-1024x1024.png\" alt=\"\" class=\"uag-image-8892\" width=\"1024\" height=\"1024\" title=\"eto sterilizer hzbocon (6)\" role=\"img\" \><\/figure><\/div>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><td><strong>উপাদান<\/strong><\/td><td><strong>স্টিম (অন্তত প্যাকেজিংয়ের একটি অংশ বাষ্পে প্রবেশযোগ্য হতে হবে)<\/strong><\/td><td><strong>EO\/FORM (at least a part of the packaging needs to be permeable to gas)<\/strong><\/td><td><strong>হাইড্রোজেন পারক্সাইড (প্লাজমা) (প্রাকৃতিক ফাইবার ভিত্তিক উপকরণ বেমানান)<\/strong><\/td><td><strong>Gamma\/E-Beam or Beta radiation (impermeable material may be used)<\/strong><\/td><td><strong>শুকনো তাপ (সর্বোচ্চ তাপমাত্রা) (অভেদ্য উপাদান ব্যবহার করা যেতে পারে)<\/strong><\/td><\/tr><\/thead><tbody><tr><td><strong>গ্যাস এবং বাষ্প ব্যাপ্তিযোগ্যতা সঙ্গে উপকরণ<\/strong><\/td><td><\/td><td><\/td><td><\/td><td><\/td><td><\/td><\/tr><tr><td>মেডিকেল গ্রেড পেপার<\/td><td>ভি<\/td><td>ভি<\/td><td>না<\/td><td>ভি<\/td><td>V ($160^{\\circ}C$)<\/td><\/tr><tr><td>পলিথিনের স্পুনবন্ড অ বোনা উপকরণ ফ্লাশ করুন<\/td><td>V (max. T $127^{\\circ}C$) not suitable for hospitals<\/td><td>ভি<\/td><td>ভি<\/td><td>ভি<\/td><td>না<\/td><\/tr><tr><td>ভেজা রাখা অ বোনা (সজ্জা এবং প্লাস্টিক ফাইবার)<\/td><td>ভি<\/td><td>ভি<\/td><td>না<\/td><td>ভি<\/td><td>না<\/td><\/tr><tr><td>এসএমএস (স্পুনবন্ড মেল্টব্লোউন স্পুনবন্ড) পলিপ্রোপিলিনের অ বোনা উপকরণ<\/td><td>ভি<\/td><td>ভি<\/td><td>ভি<\/td><td>না<\/td><td>না<\/td><\/tr><tr><td><strong>চলচ্চিত্র এবং যৌগিক চলচ্চিত্র<\/strong><\/td><td><\/td><td><\/td><td><\/td><td><\/td><td><\/td><\/tr><tr><td>PET\/PP films (Laminated)<\/td><td>ভি<\/td><td>ভি<\/td><td>ভি<\/td><td>না<\/td><td>না<\/td><\/tr><tr><td>PET\/PE films (Laminated)<\/td><td>না<\/td><td>ভি<\/td><td>ভি<\/td><td>ভি<\/td><td>না<\/td><\/tr><tr><td>অ্যালুমিনিয়াম ল্যামিনেট এবং কম্পোজিট, যেমন উচ্চ বাধা উপাদান<\/td><td>ভি<\/td><td>ভি<\/td><td>সরবরাহকারীদের স্পেসিফিকেশন দেখুন<\/td><td>ভি<\/td><td>ভি<\/td><\/tr><tr><td>APET ফিল্ম (অমরফাস পলিথিন টেরেফথালেট)<\/td><td>না<\/td><td>ভি<\/td><td>সরবরাহকারীদের স্পেসিফিকেশন দেখুন<\/td><td>ভি<\/td><td>না<\/td><\/tr><tr><td>E\/P (Ethylene-Propylene Copolymer)<\/td><td>সরবরাহকারীদের স্পেসিফিকেশন দেখুন<\/td><td>ভি<\/td><td>সরবরাহকারীদের স্পেসিফিকেশন দেখুন<\/td><td>সরবরাহকারীদের স্পেসিফিকেশন দেখুন<\/td><td>সরবরাহকারীদের স্পেসিফিকেশন দেখুন<\/td><\/tr><tr><td>এইচডিপিই ফিল্ম (উচ্চ ঘনত্বের পলিথিন)<\/td><td>V ($121^{\\circ}C$)<\/td><td>ভি<\/td><td>সরবরাহকারীদের স্পেসিফিকেশন দেখুন<\/td><td>ভি<\/td><td>না<\/td><\/tr><tr><td>LDPE ফিল্ম (নিম্ন ঘনত্ব পলিথিন)<\/td><td>না<\/td><td>ভি<\/td><td>ভি<\/td><td>ভি<\/td><td>না<\/td><\/tr><tr><td>পিএ ফিল্ম (কম্পোনেন্ট) (পলিমাইড)<\/td><td>ভি<\/td><td>ভি<\/td><td>ভি<\/td><td>ভি<\/td><td>ভি<\/td><\/tr><tr><td>PE ফিল্ম (কম্পোনেন্ট) (পলিথিন)<\/td><td>না<\/td><td>ভি<\/td><td>ভি<\/td><td>ভি<\/td><td>না<\/td><\/tr><tr><td>পিপি ফিল্ম (কম্পোনেন্ট) (পলিপ্রোপিলিন)<\/td><td>ভি<\/td><td>ভি<\/td><td>না<\/td><td>না<\/td><td>না<\/td><\/tr><tr><td>পিইটি ফিল্ম (কম্পোনেন্ট) (পলিথিন টেরেফথালেট)<\/td><td>ভি<\/td><td>ভি<\/td><td>ভি<\/td><td>ভি<\/td><td>ভি<\/td><\/tr><tr><td>PETG (PETG-Foam-, PETG-PE) ফিল্ম (PET Glycol)<\/td><td>না<\/td><td>ভি<\/td><td>সরবরাহকারীদের স্পেসিফিকেশন দেখুন<\/td><td>ভি<\/td><td>না<\/td><\/tr><tr><td>পিএস ফিল্ম (পলিস্টাইরিন)<\/td><td>না<\/td><td>ভি<\/td><td>সরবরাহকারীদের স্পেসিফিকেশন দেখুন<\/td><td>ভি<\/td><td>না<\/td><\/tr><tr><td>HIPS ফিল্ম (হাই ইমপ্যাক্ট পলিস্টাইরিন)<\/td><td>না<\/td><td>ভি<\/td><td>সরবরাহকারীদের স্পেসিফিকেশন দেখুন<\/td><td>ভি<\/td><td>না<\/td><\/tr><tr><td>পিসি ফিল্ম (পলিকার্বোনেট)<\/td><td>ভি<\/td><td>ভি<\/td><td>সরবরাহকারীদের স্পেসিফিকেশন দেখুন<\/td><td>ভি<\/td><td>ভি<\/td><\/tr><tr><td>পিভিসি ফিল্ম (পলি ভিনাইল ক্লোরাইড)<\/td><td>না<\/td><td>ভি<\/td><td>সরবরাহকারীদের স্পেসিফিকেশন দেখুন<\/td><td>না<\/td><td>না<\/td><\/tr><tr><td>TPU ফিল্ম (থার্মোপ্লাস্টিক পলিউরেথেন)<\/td><td>না<\/td><td>ভি<\/td><td>সরবরাহকারীদের স্পেসিফিকেশন দেখুন<\/td><td>ভি<\/td><td>ভি<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\"><\/p>\n","protected":false},"excerpt":{"rendered":"<p>EO\/FORM (at least a part of the packaging needs to be permeable to gas)<\/p>\n","protected":false},"author":234312599,"featured_media":8899,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_uag_custom_page_level_css":"","site-sidebar-layout":"default","site-content-layout":"","ast-site-content-layout":"default","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","ast-disable-related-posts":"","theme-transparent-header-meta":"","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"default","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"_jetpack_newsletter_access":"","_jetpack_dont_email_post_to_subs":false,"_jetpack_newsletter_tier_id":0,"_jetpack_memberships_contains_paywalled_content":false,"_jetpack_feature_clip_id":0,"_jetpack_memberships_contains_paid_content":false,"footnotes":"","jetpack_publicize_message":"","jetpack_publicize_feature_enabled":true,"jetpack_social_post_already_shared":false,"jetpack_social_options":{"image_generator_settings":{"template":"highway","default_image_id":0,"font":"","enabled":false},"version":2},"jetpack_post_was_ever_published":false},"categories":[133125,133124],"tags":[],"class_list":["post-8915","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-company-news","category-eto-sterilizer"],"yoast_head":"<!-- This site is optimized with the Yoast SEO Premium plugin v27.2 (Yoast SEO v28.0) - https:\/\/yoast.com\/product\/yoast-seo-premium-wordpress\/ -->\n<title>মেডিক্যাল প্যাকেজিং উপকরণের জন্য নির্বীজন সামঞ্জস্যতা সারণী - ইটিও স্টেরিলাইজার<\/title>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \>\n<link rel=\"canonical\" href=\"https:\/\/zjbocon.com\/?p=8915\" \>\n<meta property=\"og:locale\" content=\"en_US\" \>\n<meta property=\"og:type\" content=\"article\" \>\n<meta property=\"og:title\" content=\"Sterilization Compatibility Table for Medical Packaging Materials\" \>\n<meta property=\"og:description\" content=\"EO\/FORM (at least a part of the packaging needs to be permeable gas)\" \>\n<meta property=\"og:url\" content=\"https:\/\/zjbocon.com\/?p=8915\" \>\n<meta property=\"og:site_name\" content=\"ETO STERILIZER\" \>\n<meta property=\"article:publisher\" content=\"https:\/\/www.facebook.com\/profile.php?id=100088482339878\" \>\n<meta property=\"article:author\" content=\"https:\/\/www.facebook.com\/profile.php?id=100088482339878\" \>\n<meta property=\"article:published_time\" content=\"2025-12-05T06:57:48+00:00\" \>\n<meta property=\"article:modified_time\" content=\"2025-12-24T01:59:03+00:00\" \>\n<meta property=\"og:image\" content=\"https:\/\/zjbocon.com\/wp-content\/uploads\/2024\/11\/eto-sterilizer-hzbocon-4.png\" \>\n\t<meta property=\"og:image:width\" content=\"1200\" \>\n\t<meta property=\"og:image:height\" content=\"1200\" \>\n\t<meta property=\"og:image:type\" content=\"image\/png\" \>\n<meta name=\"author\" content=\"Bocon Technical Team\" \>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \>\n<meta name=\"twitter:creator\" content=\"@BoconAnd\" \>\n<meta name=\"twitter:site\" content=\"@BoconAnd\" \>\n<meta name=\"twitter:label1\" content=\"Written by\" \>\n\t<meta name=\"twitter:data1\" content=\"Bocon Technical Team\" \>\n\t<meta name=\"twitter:label2\" content=\"Est. reading time\" \>\n\t<meta name=\"twitter:data2\" content=\"2 minutes\" \>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\\\/\\\/zjbocon.com\\\/?p=8915#article\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/zjbocon.com\\\/?p=8915\"},\"author\":{\"name\":\"Bocon Technical Team\",\"@id\":\"https:\\\/\\\/zjbocon.com\\\/#\\\/schema\\\/person\\\/f12be028b8ae9843a4396dcc8012b425\"},\"headline\":\"Sterilization Compatibility Table for Medical Packaging Materials\",\"datePublished\":\"2025-12-05T06:57:48+00:00\",\"dateModified\":\"2025-12-24T01:59:03+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/zjbocon.com\\\/?p=8915\"},\"wordCount\":321,\"commentCount\":0,\"publisher\":{\"@id\":\"https:\\\/\\\/zjbocon.com\\\/#organization\"},\"image\":{\"@id\":\"https:\\\/\\\/zjbocon.com\\\/?p=8915#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/zjbocon.com\\\/wp-content\\\/uploads\\\/2024\\\/11\\\/eto-sterilizer-hzbocon-4.png\",\"articleSection\":[\"Company News\",\"ETO STERILIZER\"],\"inLanguage\":\"bn-BD\",\"potentialAction\":[{\"@type\":\"CommentAction\",\"name\":\"Comment\",\"target\":[\"https:\\\/\\\/zjbocon.com\\\/?p=8915#respond\"]}]},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/zjbocon.com\\\/?p=8915\",\"url\":\"https:\\\/\\\/zjbocon.com\\\/?p=8915\",\"name\":\"Sterilization Compatibility Table for Medical Packaging Materials - ETO STERILIZER\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/zjbocon.com\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/zjbocon.com\\\/?p=8915#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/zjbocon.com\\\/?p=8915#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/zjbocon.com\\\/wp-content\\\/uploads\\\/2024\\\/11\\\/eto-sterilizer-hzbocon-4.png\",\"datePublished\":\"2025-12-05T06:57:48+00:00\",\"dateModified\":\"2025-12-24T01:59:03+00:00\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/zjbocon.com\\\/?p=8915#breadcrumb\"},\"inLanguage\":\"bn-BD\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/zjbocon.com\\\/?p=8915\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"bn-BD\",\"@id\":\"https:\\\/\\\/zjbocon.com\\\/?p=8915#primaryimage\",\"url\":\"https:\\\/\\\/zjbocon.com\\\/wp-content\\\/uploads\\\/2024\\\/11\\\/eto-sterilizer-hzbocon-4.png\",\"contentUrl\":\"https:\\\/\\\/zjbocon.com\\\/wp-content\\\/uploads\\\/2024\\\/11\\\/eto-sterilizer-hzbocon-4.png\",\"width\":1200,\"height\":1200,\"caption\":\"hzbocon eto sterilizer\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/zjbocon.com\\\/?p=8915#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/zjbocon.com\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Sterilization Compatibility Table for Medical Packaging Materials\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/zjbocon.com\\\/#website\",\"url\":\"https:\\\/\\\/zjbocon.com\\\/\",\"name\":\"ETO STERILIZER\",\"description\":\"One-stop Solution Supplier of Ethylene Oxide Sterilization\",\"publisher\":{\"@id\":\"https:\\\/\\\/zjbocon.com\\\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/zjbocon.com\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"bn-BD\"},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/zjbocon.com\\\/#organization\",\"name\":\"ETO STERILIZER\",\"url\":\"https:\\\/\\\/zjbocon.com\\\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"bn-BD\",\"@id\":\"https:\\\/\\\/zjbocon.com\\\/#\\\/schema\\\/logo\\\/image\\\/\",\"url\":\"https:\\\/\\\/zjbocon.com\\\/wp-content\\\/uploads\\\/2024\\\/10\\\/logo-1.webp\",\"contentUrl\":\"https:\\\/\\\/zjbocon.com\\\/wp-content\\\/uploads\\\/2024\\\/10\\\/logo-1.webp\",\"width\":180,\"height\":60,\"caption\":\"ETO STERILIZER\"},\"image\":{\"@id\":\"https:\\\/\\\/zjbocon.com\\\/#\\\/schema\\\/logo\\\/image\\\/\"},\"sameAs\":[\"https:\\\/\\\/www.facebook.com\\\/profile.php?id=100088482339878\",\"https:\\\/\\\/x.com\\\/BoconAnd\",\"https:\\\/\\\/www.linkedin.com\\\/in\\\/--06a221139\\\/\"]},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/zjbocon.com\\\/#\\\/schema\\\/person\\\/f12be028b8ae9843a4396dcc8012b425\",\"name\":\"Bocon Technical Team\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"bn-BD\",\"@id\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/d7a825658be227f26b237e519f8541e05aabc9ff27b8eec4544a233a48c53be0?s=96&d=identicon&r=g\",\"url\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/d7a825658be227f26b237e519f8541e05aabc9ff27b8eec4544a233a48c53be0?s=96&d=identicon&r=g\",\"contentUrl\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/d7a825658be227f26b237e519f8541e05aabc9ff27b8eec4544a233a48c53be0?s=96&d=identicon&r=g\",\"caption\":\"Bocon Technical Team\"},\"sameAs\":[\"https:\\\/\\\/zjbocon.com\\\/\",\"https:\\\/\\\/www.facebook.com\\\/profile.php?id=100088482339878\",\"https:\\\/\\\/www.linkedin.com\\\/in\\\/\\\/hayley--968190269\\\/\"],\"url\":\"https:\\\/\\\/zjbocon.com\\\/?author=234312599\"}]}<\/script>\n<!-- \/ Yoast SEO Premium plugin. -->","yoast_head_json":{"title":"Sterilization Compatibility Table for Medical Packaging Materials - ETO STERILIZER","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/zjbocon.com\/?p=8915","og_locale":"en_US","og_type":"article","og_title":"Sterilization Compatibility Table for Medical Packaging Materials","og_description":"EO\/FORM (at least a part of the packaging needs to be permeable to gas)","og_url":"https:\/\/zjbocon.com\/?p=8915","og_site_name":"ETO STERILIZER","article_publisher":"https:\/\/www.facebook.com\/profile.php?id=100088482339878","article_author":"https:\/\/www.facebook.com\/profile.php?id=100088482339878","article_published_time":"2025-12-05T06:57:48+00:00","article_modified_time":"2025-12-24T01:59:03+00:00","og_image":[{"width":1200,"height":1200,"url":"https:\/\/zjbocon.com\/wp-content\/uploads\/2024\/11\/eto-sterilizer-hzbocon-4.png","type":"image\/png"}],"author":"Bocon Technical Team","twitter_card":"summary_large_image","twitter_creator":"@BoconAnd","twitter_site":"@BoconAnd","twitter_misc":{"Written by":"Bocon Technical Team","Est. reading time":"2 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/zjbocon.com\/?p=8915#article","isPartOf":{"@id":"https:\/\/zjbocon.com\/?p=8915"},"author":{"name":"Bocon Technical Team","@id":"https:\/\/zjbocon.com\/#\/schema\/person\/f12be028b8ae9843a4396dcc8012b425"},"headline":"Sterilization Compatibility Table for Medical Packaging Materials","datePublished":"2025-12-05T06:57:48+00:00","dateModified":"2025-12-24T01:59:03+00:00","mainEntityOfPage":{"@id":"https:\/\/zjbocon.com\/?p=8915"},"wordCount":321,"commentCount":0,"publisher":{"@id":"https:\/\/zjbocon.com\/#organization"},"image":{"@id":"https:\/\/zjbocon.com\/?p=8915#primaryimage"},"thumbnailUrl":"https:\/\/zjbocon.com\/wp-content\/uploads\/2024\/11\/eto-sterilizer-hzbocon-4.png","articleSection":["Company News","ETO STERILIZER"],"inLanguage":"bn-BD","potentialAction":[{"@type":"CommentAction","name":"Comment","target":["https:\/\/zjbocon.com\/?p=8915#respond"]}]},{"@type":"WebPage","@id":"https:\/\/zjbocon.com\/?p=8915","url":"https:\/\/zjbocon.com\/?p=8915","name":"Sterilization Compatibility Table for Medical Packaging Materials - ETO STERILIZER","isPartOf":{"@id":"https:\/\/zjbocon.com\/#website"},"primaryImageOfPage":{"@id":"https:\/\/zjbocon.com\/?p=8915#primaryimage"},"image":{"@id":"https:\/\/zjbocon.com\/?p=8915#primaryimage"},"thumbnailUrl":"https:\/\/zjbocon.com\/wp-content\/uploads\/2024\/11\/eto-sterilizer-hzbocon-4.png","datePublished":"2025-12-05T06:57:48+00:00","dateModified":"2025-12-24T01:59:03+00:00","breadcrumb":{"@id":"https:\/\/zjbocon.com\/?p=8915#breadcrumb"},"inLanguage":"bn-BD","potentialAction":[{"@type":"ReadAction","target":["https:\/\/zjbocon.com\/?p=8915"]}]},{"@type":"ImageObject","inLanguage":"bn-BD","@id":"https:\/\/zjbocon.com\/?p=8915#primaryimage","url":"https:\/\/zjbocon.com\/wp-content\/uploads\/2024\/11\/eto-sterilizer-hzbocon-4.png","contentUrl":"https:\/\/zjbocon.com\/wp-content\/uploads\/2024\/11\/eto-sterilizer-hzbocon-4.png","width":1200,"height":1200,"caption":"hzbocon eto sterilizer"},{"@type":"BreadcrumbList","@id":"https:\/\/zjbocon.com\/?p=8915#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/zjbocon.com\/"},{"@type":"ListItem","position":2,"name":"Sterilization Compatibility Table for Medical Packaging Materials"}]},{"@type":"WebSite","@id":"https:\/\/zjbocon.com\/#website","url":"https:\/\/zjbocon.com\/","name":"ETO STERILIZER","description":"One-stop Solution Supplier of Ethylene Oxide Sterilization","publisher":{"@id":"https:\/\/zjbocon.com\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/zjbocon.com\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"bn-BD"},{"@type":"Organization","@id":"https:\/\/zjbocon.com\/#organization","name":"ETO STERILIZER","url":"https:\/\/zjbocon.com\/","logo":{"@type":"ImageObject","inLanguage":"bn-BD","@id":"https:\/\/zjbocon.com\/#\/schema\/logo\/image\/","url":"https:\/\/zjbocon.com\/wp-content\/uploads\/2024\/10\/logo-1.webp","contentUrl":"https:\/\/zjbocon.com\/wp-content\/uploads\/2024\/10\/logo-1.webp","width":180,"height":60,"caption":"ETO STERILIZER"},"image":{"@id":"https:\/\/zjbocon.com\/#\/schema\/logo\/image\/"},"sameAs":["https:\/\/www.facebook.com\/profile.php?id=100088482339878","https:\/\/x.com\/BoconAnd","https:\/\/www.linkedin.com\/in\/--06a221139\/"]},{"@type":"Person","@id":"https:\/\/zjbocon.com\/#\/schema\/person\/f12be028b8ae9843a4396dcc8012b425","name":"Bocon Technical Team","image":{"@type":"ImageObject","inLanguage":"bn-BD","@id":"https:\/\/secure.gravatar.com\/avatar\/d7a825658be227f26b237e519f8541e05aabc9ff27b8eec4544a233a48c53be0?s=96&d=identicon&r=g","url":"https:\/\/secure.gravatar.com\/avatar\/d7a825658be227f26b237e519f8541e05aabc9ff27b8eec4544a233a48c53be0?s=96&d=identicon&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/d7a825658be227f26b237e519f8541e05aabc9ff27b8eec4544a233a48c53be0?s=96&d=identicon&r=g","caption":"Bocon Technical Team"},"sameAs":["https:\/\/zjbocon.com\/","https:\/\/www.facebook.com\/profile.php?id=100088482339878","https:\/\/www.linkedin.com\/in\/\/hayley--968190269\/"],"url":"https:\/\/zjbocon.com\/?author=234312599"}]}},"jetpack_publicize_connections":[],"jetpack_featured_media_url":"https:\/\/zjbocon.com\/wp-content\/uploads\/2024\/11\/eto-sterilizer-hzbocon-4.png","uagb_featured_image_src":{"full":["https:\/\/zjbocon.com\/wp-content\/uploads\/2024\/11\/eto-sterilizer-hzbocon-4.png",1200,1200,false],"thumbnail":["https:\/\/zjbocon.com\/wp-content\/uploads\/2024\/11\/eto-sterilizer-hzbocon-4-150x150.png",150,150,true],"medium":["https:\/\/zjbocon.com\/wp-content\/uploads\/2024\/11\/eto-sterilizer-hzbocon-4-300x300.png",300,300,true],"medium_large":["https:\/\/zjbocon.com\/wp-content\/uploads\/2024\/11\/eto-sterilizer-hzbocon-4-768x768.png",768,768,true],"large":["https:\/\/zjbocon.com\/wp-content\/uploads\/2024\/11\/eto-sterilizer-hzbocon-4-1024x1024.png",1024,1024,true],"1536x1536":["https:\/\/zjbocon.com\/wp-content\/uploads\/2024\/11\/eto-sterilizer-hzbocon-4.png",1200,1200,false],"2048x2048":["https:\/\/zjbocon.com\/wp-content\/uploads\/2024\/11\/eto-sterilizer-hzbocon-4.png",1200,1200,false],"woocommerce_thumbnail":["https:\/\/zjbocon.com\/wp-content\/uploads\/2024\/11\/eto-sterilizer-hzbocon-4-600x600.png",600,600,true],"woocommerce_single":["https:\/\/zjbocon.com\/wp-content\/uploads\/2024\/11\/eto-sterilizer-hzbocon-4-600x600.png",600,600,true],"woocommerce_gallery_thumbnail":["https:\/\/zjbocon.com\/wp-content\/uploads\/2024\/11\/eto-sterilizer-hzbocon-4-100x100.png",100,100,true]},"uagb_author_info":{"display_name":"Bocon Technical Team","author_link":"https:\/\/zjbocon.com\/?author=234312599"},"uagb_comment_info":0,"uagb_excerpt":"EO\/FORM (at least a part of the packaging needs to be permeable to gas)","jetpack_likes_enabled":true,"jetpack_sharing_enabled":true,"jetpack_shortlink":"https:\/\/wp.me\/pgZDV6-2jN","jetpack-related-posts":[{"id":9276,"url":"https:\/\/zjbocon.com\/?p=9276","url_meta":{"origin":8915,"position":0},"title":"Sterilization Compatibility of Sterile Barrier Systems","author":"Bocon Technical Team","date":"2026-02-06","format":false,"excerpt":"Sterilization Compatibility of Sterile Barrier Systems Technical White Paper 1. Introduction The compatibility between sterile barrier systems (SBS) and sterilization processes is a critical engineering consideration in medical device packaging design. Inappropriate material-process combinations may lead to insufficient sterilant penetration, material degradation, or loss of microbial barrier integrity. This technical\u2026","rel":"","context":"In &quot;ETO STERILIZER&quot;","block_context":{"text":"ETO STERILIZER","link":"https:\/\/zjbocon.com\/?cat=133124"},"img":{"alt_text":"","src":"https:\/\/i0.wp.com\/zjbocon.com\/wp-content\/uploads\/2024\/11\/eto-sterilizer-hzbocon-5.png?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/zjbocon.com\/wp-content\/uploads\/2024\/11\/eto-sterilizer-hzbocon-5.png?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/zjbocon.com\/wp-content\/uploads\/2024\/11\/eto-sterilizer-hzbocon-5.png?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/zjbocon.com\/wp-content\/uploads\/2024\/11\/eto-sterilizer-hzbocon-5.png?resize=700%2C400&ssl=1 2x, https:\/\/i0.wp.com\/zjbocon.com\/wp-content\/uploads\/2024\/11\/eto-sterilizer-hzbocon-5.png?resize=1050%2C600&ssl=1 3x"},"classes":[]},{"id":8909,"url":"https:\/\/zjbocon.com\/?p=8909","url_meta":{"origin":8915,"position":1},"title":"Medical Device Sterilization Methods Comparison","author":"Bocon Technical Team","date":"2025-12-05","format":false,"excerpt":"Penetrates packaging materials and device lumens. Optimal material compatibility (Low temp). \"Product can be sterilized in its sealed final packaging.\" Simple operation and monitoring. Broad microbicidal activity. Low temperature. Sterility assurance and therapeutic effect. Allows immediate product release after processing (Parametric Release), shortening turnaround time, helping to get products to\u2026","rel":"","context":"In &quot;ETO STERILIZER&quot;","block_context":{"text":"ETO STERILIZER","link":"https:\/\/zjbocon.com\/?cat=133124"},"img":{"alt_text":"","src":"https:\/\/i0.wp.com\/zjbocon.com\/wp-content\/uploads\/2024\/11\/eto-sterilizer-hzbocon-1.png?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/zjbocon.com\/wp-content\/uploads\/2024\/11\/eto-sterilizer-hzbocon-1.png?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/zjbocon.com\/wp-content\/uploads\/2024\/11\/eto-sterilizer-hzbocon-1.png?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/zjbocon.com\/wp-content\/uploads\/2024\/11\/eto-sterilizer-hzbocon-1.png?resize=700%2C400&ssl=1 2x, https:\/\/i0.wp.com\/zjbocon.com\/wp-content\/uploads\/2024\/11\/eto-sterilizer-hzbocon-1.png?resize=1050%2C600&ssl=1 3x"},"classes":[]},{"id":9518,"url":"https:\/\/zjbocon.com\/?p=9518","url_meta":{"origin":8915,"position":2},"title":"GMP Compliance Guide: Sterile Equipment Design &amp; Sterilization Validation","author":"Bocon Technical Team","date":"2026-03-17","format":false,"excerpt":"Integrated GMP Compliance Guide: Sterile Equipment & Post-Sterilization Management Contact Support WhatsApp Us Best Practices for Equipment and Sterilization in Sterile Manufacturing Complete GMP Compliance Guide with Integrated Post-Sterilization Protocols 1. Equipment Design & Maintenance Standards 1.1 Design Documentation Detailed written descriptions (PFDs, P&IDs) must be provided in the initial\u2026","rel":"","context":"Similar post","block_context":{"text":"Similar post","link":""},"img":{"alt_text":"","src":"https:\/\/i0.wp.com\/zjbocon.com\/wp-content\/uploads\/2026\/03\/eto-sterilizer-1.webp?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/zjbocon.com\/wp-content\/uploads\/2026\/03\/eto-sterilizer-1.webp?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/zjbocon.com\/wp-content\/uploads\/2026\/03\/eto-sterilizer-1.webp?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/zjbocon.com\/wp-content\/uploads\/2026\/03\/eto-sterilizer-1.webp?resize=700%2C400&ssl=1 2x, https:\/\/i0.wp.com\/zjbocon.com\/wp-content\/uploads\/2026\/03\/eto-sterilizer-1.webp?resize=1050%2C600&ssl=1 3x, https:\/\/i0.wp.com\/zjbocon.com\/wp-content\/uploads\/2026\/03\/eto-sterilizer-1.webp?resize=1400%2C800&ssl=1 4x"},"classes":[]},{"id":2224,"url":"https:\/\/zjbocon.com\/?p=2224","url_meta":{"origin":8915,"position":3},"title":"Factors Affecting the EO Gas Sterilization Process","author":"Bocon Technical Team","date":"2024-11-22","format":false,"excerpt":"Within a certain range of gas concentration, the higher the concentration, the better theEO Gas Sterilization effect; beyond 1000 mg\/L, the improvement in sterilization effect is not significant.","rel":"","context":"In &quot;ETO STERILIZER&quot;","block_context":{"text":"ETO STERILIZER","link":"https:\/\/zjbocon.com\/?cat=133124"},"img":{"alt_text":"","src":"https:\/\/i0.wp.com\/zjbocon.com\/wp-content\/uploads\/2025\/09\/ethylene-oxide-sterilization-10-scaled.webp?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/zjbocon.com\/wp-content\/uploads\/2025\/09\/ethylene-oxide-sterilization-10-scaled.webp?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/zjbocon.com\/wp-content\/uploads\/2025\/09\/ethylene-oxide-sterilization-10-scaled.webp?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/zjbocon.com\/wp-content\/uploads\/2025\/09\/ethylene-oxide-sterilization-10-scaled.webp?resize=700%2C400&ssl=1 2x, https:\/\/i0.wp.com\/zjbocon.com\/wp-content\/uploads\/2025\/09\/ethylene-oxide-sterilization-10-scaled.webp?resize=1050%2C600&ssl=1 3x, https:\/\/i0.wp.com\/zjbocon.com\/wp-content\/uploads\/2025\/09\/ethylene-oxide-sterilization-10-scaled.webp?resize=1400%2C800&ssl=1 4x"},"classes":[]},{"id":2076,"url":"https:\/\/zjbocon.com\/?p=2076","url_meta":{"origin":8915,"position":4},"title":"PQ in Ethylene oxide sterilization chamber","author":"Bocon Technical Team","date":"2024-10-31","format":false,"excerpt":"PQ is the stage of validation that uses Ethylene oxide sterilization chamber to demonstrate that the Ethylene oxide sterilization equipment consistently operates in accordance with predetermined acceptance criteria and the process yields a product that is sterile and meets the specified requirements.","rel":"","context":"In &quot;ETO STERILIZER&quot;","block_context":{"text":"ETO STERILIZER","link":"https:\/\/zjbocon.com\/?cat=133124"},"img":{"alt_text":"","src":"https:\/\/i0.wp.com\/zjbocon.com\/wp-content\/uploads\/2025\/09\/eto-sterilizer-1.webp?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/zjbocon.com\/wp-content\/uploads\/2025\/09\/eto-sterilizer-1.webp?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/zjbocon.com\/wp-content\/uploads\/2025\/09\/eto-sterilizer-1.webp?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/zjbocon.com\/wp-content\/uploads\/2025\/09\/eto-sterilizer-1.webp?resize=700%2C400&ssl=1 2x, https:\/\/i0.wp.com\/zjbocon.com\/wp-content\/uploads\/2025\/09\/eto-sterilizer-1.webp?resize=1050%2C600&ssl=1 3x"},"classes":[]},{"id":9625,"url":"https:\/\/zjbocon.com\/?p=9625","url_meta":{"origin":8915,"position":5},"title":"Factors Influencing Product Residuals","author":"Bocon Technical Team","date":"2026-05-06","format":false,"excerpt":"Explore technical factors influencing product residuals in EO sterilization. Learn how material composition, packaging density, and aeration cycles impact compliance with ISO 11135.","rel":"","context":"Similar post","block_context":{"text":"Similar post","link":""},"img":{"alt_text":"","src":"https:\/\/i0.wp.com\/zjbocon.com\/wp-content\/uploads\/2026\/03\/eto-sterilizer-27.webp?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/zjbocon.com\/wp-content\/uploads\/2026\/03\/eto-sterilizer-27.webp?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/zjbocon.com\/wp-content\/uploads\/2026\/03\/eto-sterilizer-27.webp?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/zjbocon.com\/wp-content\/uploads\/2026\/03\/eto-sterilizer-27.webp?resize=700%2C400&ssl=1 2x, https:\/\/i0.wp.com\/zjbocon.com\/wp-content\/uploads\/2026\/03\/eto-sterilizer-27.webp?resize=1050%2C600&ssl=1 3x"},"classes":[]}],"_links":{"self":[{"href":"https:\/\/zjbocon.com\/index.php?rest_route=\/wp\/v2\/posts\/8915","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/zjbocon.com\/index.php?rest_route=\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/zjbocon.com\/index.php?rest_route=\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/zjbocon.com\/index.php?rest_route=\/wp\/v2\/users\/234312599"}],"replies":[{"embeddable":true,"href":"https:\/\/zjbocon.com\/index.php?rest_route=%2Fwp%2Fv2%2Fcomments&post=8915"}],"version-history":[{"count":1,"href":"https:\/\/zjbocon.com\/index.php?rest_route=\/wp\/v2\/posts\/8915\/revisions"}],"predecessor-version":[{"id":8916,"href":"https:\/\/zjbocon.com\/index.php?rest_route=\/wp\/v2\/posts\/8915\/revisions\/8916"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/zjbocon.com\/index.php?rest_route=\/wp\/v2\/media\/8899"}],"wp:attachment":[{"href":"https:\/\/zjbocon.com\/index.php?rest_route=%2Fwp%2Fv2%2Fmedia&parent=8915"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/zjbocon.com\/index.php?rest_route=%2Fwp%2Fv2%2Fcategories&post=8915"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/zjbocon.com\/index.php?rest_route=%2Fwp%2Fv2%2Ftags&post=8915"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}