{"id":2448,"date":"2024-12-20T10:40:39","date_gmt":"2024-12-20T02:40:39","guid":{"rendered":"https:\/\/zjbocon.com\/?p=2448"},"modified":"2025-12-05T10:53:12","modified_gmt":"2025-12-05T02:53:12","slug":"eto-sterilization-chamber-temperature-distribution-testing","status":"publish","type":"post","link":"https:\/\/zjbocon.com\/?p=2448","title":{"rendered":"eto sterilization Chamber Temperature Distribution Testing"},"content":{"rendered":"\n<div class=\"wp-block-uagb-image uagb-block-b7b2c0b4 wp-block-uagb-image--layout-default wp-block-uagb-image--effect-static wp-block-uagb-image--align-none\"><figure class=\"wp-block-uagb-image__figure\"><img loading=\"lazy\" decoding=\"async\" src=\"https:\/\/zjbocon.com\/wp-content\/uploads\/2025\/09\/ethylene-oxide-sterilization-54-225x300.webp\" alt=\"\" class=\"uag-image-8460\" width=\"225\" height=\"300\" title=\"ethylene-oxide-sterilization-54\" role=\"img\" \><\/figure><\/div>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"h-c-1-temperature-testing-of-inner-surfaces-in-the-eto-sterilization-chamber\">C.1 Temperature Testing sa Inner Surfaces sa eto Sterilization Chamber<\/h2>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"h-c-1-1\">C.1.1<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Ang temperatura sa mga representante nga mga lugar sa sulod nga mga ibabaw kinahanglan nga sukdon ug irekord gamit ang mga instrumento sa pagrekord sa temperatura nga nagsunod sa mga kinahanglanon sa Appendix B.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"h-c-1-2\">C.1.2<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Ang matag sulud sa sulud kinahanglan nga sukdon labing menos kausa (pananglitan, labing gamay nga 6 ka dungan nga mga punto sa pagsukod). Alang sa mga sterilizer nga adunay kinatibuk-ang gidaghanon tali sa 300 L ug 8000 L, ang matag nawong kinahanglan nga sukdon labing menos 2 ka beses. Alang sa matag dugang nga 4000 L sa kinatibuk-ang volume, usa ka dugang nga 6 ka dungan nga mga punto sa pagsukod kinahanglan idugang.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"h-c-1-3\">C.1.3<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Kini nga pagsulay kinahanglan nga ipahigayon nga ang eto sterilization chamber nga walay sulod ug ang mga pultahan sirado, bisan ang mga auxiliary device nga gikinahanglan alang sa eo sterilization nga proseso mahimong ma-install sa chamber.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"h-c-1-4\">C.1.4<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Ang temperatura nga gitakda alang sa bisan unsang yugto sa preheating sa tiggama kinahanglan nga irekord.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"h-c-2-temperature-testing-of-empty-eto-sterilization-chamber\">C.2 Pagsulay sa Temperatura sa Hawanan nga Eto Sterilization Chamber<\/h2>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"h-c-2-1\">C.2.1<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Gamit ang mga instrumento sa pagrekord sa temperatura nga nagsunod sa Appendix B, ang temperatura sa mga representatibo nga mga dapit sa magamit nga luna sa eo sterilization chamber kinahanglang irekord.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"h-c-2-2\">C.2.2<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Kinahanglan adunay labing menos 6 ka magkadungan nga mga punto sa pagsukod. Alang sa mga sterilizer nga adunay kinatibuk-ang gidaghanon tali sa 300 L ug 8000 L, labing menos 12 ka dungan nga pagsukod ang kinahanglan buhaton; alang sa matag dugang nga 4000 L, usa ka dugang nga 6 ka dungan nga mga punto sa pagsukod kinahanglan idugang. Timan-i nga ang lugar sa pagsukod kinahanglan nga maglakip sa mga rehiyon sulod sa magamit nga Ethylene oxide sterilization chamber space diin ang pag-usab-usab sa temperatura mahimong hilabihan ka dako (mga lugar nga adunay grabe nga mga kalainan sa temperatura), sama sa mga lugar nga dili init duol sa pultahan sa sterilization chamber ug mga lugar nga duol sa mga steam injection point.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"h-c-2-3\">C.2.3<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Atol sa pagsulay, ang sterilization chamber kinahanglan nga walay sulod apan adunay mga auxiliary device nga gikinahanglan alang sa Ethylene oxide sterilization process nga na-install, nga ang mga pultahan sa Ethylene oxide sterilization chamber sirado.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"h-c-2-4\">C.2.4<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Sa tibuok tibuok Ethylene oxide sterilization cycle, ang lokasyon sa matag sukod sa temperatura kinahanglang irekord, nga nagdetalye sa mga temperatura sa nagkalain-laing lugar sa eo sterilization chamber.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Mubo nga sulat:<\/strong> Kini nga pagsulay mahimong mogamit sa dili makahilo, dili masunog nga mga gas o mga sagol isip mga puli sa ahente sa pag-sterilize nga gi-inject sa eto sterilization chamber pinaagi sa ethylene oxide injection system (lakip ang vaporizer).<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"h-if-you-want-to-know-more-about-ethylene-oxide-sterilization\">Kung gusto nimo mahibal-an ang dugang bahin sa ethylene Oxide Sterilisasyon<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Telepono:<a href=\"https:\/\/wa.me\/8619975258603\">+8619975258603<\/a><\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Email:<a href=\"mailto:hayley@hzbocon.com\">hayley@hzbocon.com<\/a><\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Lokal nga Dapit: Room 1202, Caitong Zhongxin, Xiasha District, Hangzhou City, Zhejiang Province, China<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Website:<a href=\"https:\/\/www.hzbocon.com\/\">hzbocon.com<\/a><a href=\"https:\/\/zjbocon.com\/\">&nbsp;zjbocon.com<\/a><\/p>\n","protected":false},"excerpt":{"rendered":"<p>Ang temperatura sa mga representante nga mga lugar sa sulod nga mga ibabaw kinahanglan nga sukdon ug irekord gamit ang mga instrumento sa pagrekord sa temperatura nga nagsunod sa mga kinahanglanon sa Appendix B.<\/p>\n","protected":false},"author":234312599,"featured_media":8460,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_uag_custom_page_level_css":"","site-sidebar-layout":"default","site-content-layout":"","ast-site-content-layout":"default","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","ast-disable-related-posts":"","theme-transparent-header-meta":"","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"set","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"_jetpack_newsletter_access":"","_jetpack_dont_email_post_to_subs":false,"_jetpack_newsletter_tier_id":0,"_jetpack_memberships_contains_paywalled_content":false,"_jetpack_feature_clip_id":0,"_jetpack_memberships_contains_paid_content":false,"footnotes":"","jetpack_publicize_message":"","jetpack_publicize_feature_enabled":true,"jetpack_social_post_already_shared":false,"jetpack_social_options":{"image_generator_settings":{"template":"highway","enabled":false},"version":2},"jetpack_post_was_ever_published":false},"categories":[133125,133124],"tags":[],"class_list":["post-2448","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-company-news","category-eto-sterilizer"],"yoast_head":"<!-- This site is optimized with the Yoast SEO Premium plugin v27.2 (Yoast SEO v28.0) - https:\/\/yoast.com\/product\/yoast-seo-premium-wordpress\/ -->\n<title>eto sterilization Chamber Temperature Distribution Testing - ETO STERILIZER<\/title>\n<meta name=\"description\" content=\"C.1 Temperature Testing of Inner Surfaces in the eto Sterilization Chamber C.2 Empty Chamber\" \>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \>\n<link rel=\"canonical\" href=\"https:\/\/zjbocon.com\/?p=2448\" \>\n<meta property=\"og:locale\" content=\"en_US\" \>\n<meta property=\"og:type\" content=\"article\" \>\n<meta property=\"og:title\" content=\"eto sterilization Chamber Temperature Distribution Testing\" \>\n<meta property=\"og:description\" content=\"C.1 Temperature Testing of Inner Surfaces in the eto Sterilization Chamber C.2 Empty Chamber\" \>\n<meta property=\"og:url\" content=\"https:\/\/zjbocon.com\/?p=2448\" \>\n<meta property=\"og:site_name\" content=\"ETO STERILIZER\" \>\n<meta property=\"article:publisher\" content=\"https:\/\/www.facebook.com\/profile.php?id=100088482339878\" \>\n<meta property=\"article:author\" content=\"https:\/\/www.facebook.com\/profile.php?id=100088482339878\" \>\n<meta property=\"article:published_time\" content=\"2024-12-20T02:40:39+00:00\" \>\n<meta property=\"article:modified_time\" content=\"2025-12-05T02:53:12+00:00\" \>\n<meta property=\"og:image\" content=\"https:\/\/zjbocon.com\/wp-content\/uploads\/2025\/09\/ethylene-oxide-sterilization-54.webp\" \>\n\t<meta property=\"og:image:width\" content=\"1279\" \>\n\t<meta property=\"og:image:height\" content=\"1706\" \>\n\t<meta property=\"og:image:type\" content=\"image\/webp\" \>\n<meta name=\"author\" content=\"Bocon Technical Team\" \>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \>\n<meta name=\"twitter:creator\" content=\"@BoconAnd\" \>\n<meta name=\"twitter:site\" content=\"@BoconAnd\" \>\n<meta name=\"twitter:label1\" content=\"Written by\" \>\n\t<meta name=\"twitter:data1\" content=\"Bocon Technical Team\" \>\n\t<meta name=\"twitter:label2\" content=\"Est. reading time\" \>\n\t<meta name=\"twitter:data2\" content=\"3 minutes\" \>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\\\/\\\/zjbocon.com\\\/?p=2448#article\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/zjbocon.com\\\/?p=2448\"},\"author\":{\"name\":\"Bocon Technical Team\",\"@id\":\"https:\\\/\\\/zjbocon.com\\\/#\\\/schema\\\/person\\\/f12be028b8ae9843a4396dcc8012b425\"},\"headline\":\"eto sterilization Chamber Temperature Distribution Testing\",\"datePublished\":\"2024-12-20T02:40:39+00:00\",\"dateModified\":\"2025-12-05T02:53:12+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/zjbocon.com\\\/?p=2448\"},\"wordCount\":383,\"commentCount\":0,\"publisher\":{\"@id\":\"https:\\\/\\\/zjbocon.com\\\/#organization\"},\"image\":{\"@id\":\"https:\\\/\\\/zjbocon.com\\\/?p=2448#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/zjbocon.com\\\/wp-content\\\/uploads\\\/2025\\\/09\\\/ethylene-oxide-sterilization-54.webp\",\"articleSection\":[\"Company News\",\"ETO STERILIZER\"],\"inLanguage\":\"ceb\",\"potentialAction\":[{\"@type\":\"CommentAction\",\"name\":\"Comment\",\"target\":[\"https:\\\/\\\/zjbocon.com\\\/?p=2448#respond\"]}]},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/zjbocon.com\\\/?p=2448\",\"url\":\"https:\\\/\\\/zjbocon.com\\\/?p=2448\",\"name\":\"eto sterilization Chamber Temperature Distribution Testing - ETO STERILIZER\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/zjbocon.com\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/zjbocon.com\\\/?p=2448#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/zjbocon.com\\\/?p=2448#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/zjbocon.com\\\/wp-content\\\/uploads\\\/2025\\\/09\\\/ethylene-oxide-sterilization-54.webp\",\"datePublished\":\"2024-12-20T02:40:39+00:00\",\"dateModified\":\"2025-12-05T02:53:12+00:00\",\"description\":\"C.1 Temperature Testing of Inner Surfaces in the eto Sterilization Chamber C.2 Temperature Testing of Empty eto Sterilization Chamber\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/zjbocon.com\\\/?p=2448#breadcrumb\"},\"inLanguage\":\"ceb\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/zjbocon.com\\\/?p=2448\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"ceb\",\"@id\":\"https:\\\/\\\/zjbocon.com\\\/?p=2448#primaryimage\",\"url\":\"https:\\\/\\\/zjbocon.com\\\/wp-content\\\/uploads\\\/2025\\\/09\\\/ethylene-oxide-sterilization-54.webp\",\"contentUrl\":\"https:\\\/\\\/zjbocon.com\\\/wp-content\\\/uploads\\\/2025\\\/09\\\/ethylene-oxide-sterilization-54.webp\",\"width\":1279,\"height\":1706},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/zjbocon.com\\\/?p=2448#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/zjbocon.com\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"eto sterilization Chamber Temperature Distribution Testing\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/zjbocon.com\\\/#website\",\"url\":\"https:\\\/\\\/zjbocon.com\\\/\",\"name\":\"ETO STERILIZER\",\"description\":\"One-stop Solution Supplier of Ethylene Oxide Sterilization\",\"publisher\":{\"@id\":\"https:\\\/\\\/zjbocon.com\\\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/zjbocon.com\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"ceb\"},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/zjbocon.com\\\/#organization\",\"name\":\"ETO STERILIZER\",\"url\":\"https:\\\/\\\/zjbocon.com\\\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"ceb\",\"@id\":\"https:\\\/\\\/zjbocon.com\\\/#\\\/schema\\\/logo\\\/image\\\/\",\"url\":\"https:\\\/\\\/zjbocon.com\\\/wp-content\\\/uploads\\\/2024\\\/10\\\/logo-1.webp\",\"contentUrl\":\"https:\\\/\\\/zjbocon.com\\\/wp-content\\\/uploads\\\/2024\\\/10\\\/logo-1.webp\",\"width\":180,\"height\":60,\"caption\":\"ETO STERILIZER\"},\"image\":{\"@id\":\"https:\\\/\\\/zjbocon.com\\\/#\\\/schema\\\/logo\\\/image\\\/\"},\"sameAs\":[\"https:\\\/\\\/www.facebook.com\\\/profile.php?id=100088482339878\",\"https:\\\/\\\/x.com\\\/BoconAnd\",\"https:\\\/\\\/www.linkedin.com\\\/in\\\/--06a221139\\\/\"]},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/zjbocon.com\\\/#\\\/schema\\\/person\\\/f12be028b8ae9843a4396dcc8012b425\",\"name\":\"Bocon Technical Team\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"ceb\",\"@id\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/d7a825658be227f26b237e519f8541e05aabc9ff27b8eec4544a233a48c53be0?s=96&d=identicon&r=g\",\"url\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/d7a825658be227f26b237e519f8541e05aabc9ff27b8eec4544a233a48c53be0?s=96&d=identicon&r=g\",\"contentUrl\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/d7a825658be227f26b237e519f8541e05aabc9ff27b8eec4544a233a48c53be0?s=96&d=identicon&r=g\",\"caption\":\"Bocon Technical Team\"},\"sameAs\":[\"https:\\\/\\\/zjbocon.com\\\/\",\"https:\\\/\\\/www.facebook.com\\\/profile.php?id=100088482339878\",\"https:\\\/\\\/www.linkedin.com\\\/in\\\/\\\/hayley--968190269\\\/\"],\"url\":\"https:\\\/\\\/zjbocon.com\\\/?author=234312599\"}]}<\/script>\n<!-- \/ Yoast SEO Premium plugin. -->","yoast_head_json":{"title":"eto sterilization Chamber Temperature Distribution Testing - ETO STERILIZER","description":"C.1 Temperature Testing of Inner Surfaces in the eto Sterilization Chamber C.2 Temperature Testing of Empty eto Sterilization Chamber","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/zjbocon.com\/?p=2448","og_locale":"en_US","og_type":"article","og_title":"eto sterilization Chamber Temperature Distribution Testing","og_description":"C.1 Temperature Testing of Inner Surfaces in the eto Sterilization Chamber C.2 Temperature Testing of Empty eto Sterilization Chamber","og_url":"https:\/\/zjbocon.com\/?p=2448","og_site_name":"ETO STERILIZER","article_publisher":"https:\/\/www.facebook.com\/profile.php?id=100088482339878","article_author":"https:\/\/www.facebook.com\/profile.php?id=100088482339878","article_published_time":"2024-12-20T02:40:39+00:00","article_modified_time":"2025-12-05T02:53:12+00:00","og_image":[{"width":1279,"height":1706,"url":"https:\/\/zjbocon.com\/wp-content\/uploads\/2025\/09\/ethylene-oxide-sterilization-54.webp","type":"image\/webp"}],"author":"Bocon Technical Team","twitter_card":"summary_large_image","twitter_creator":"@BoconAnd","twitter_site":"@BoconAnd","twitter_misc":{"Written by":"Bocon Technical Team","Est. reading time":"3 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/zjbocon.com\/?p=2448#article","isPartOf":{"@id":"https:\/\/zjbocon.com\/?p=2448"},"author":{"name":"Bocon Technical Team","@id":"https:\/\/zjbocon.com\/#\/schema\/person\/f12be028b8ae9843a4396dcc8012b425"},"headline":"eto sterilization Chamber Temperature Distribution Testing","datePublished":"2024-12-20T02:40:39+00:00","dateModified":"2025-12-05T02:53:12+00:00","mainEntityOfPage":{"@id":"https:\/\/zjbocon.com\/?p=2448"},"wordCount":383,"commentCount":0,"publisher":{"@id":"https:\/\/zjbocon.com\/#organization"},"image":{"@id":"https:\/\/zjbocon.com\/?p=2448#primaryimage"},"thumbnailUrl":"https:\/\/zjbocon.com\/wp-content\/uploads\/2025\/09\/ethylene-oxide-sterilization-54.webp","articleSection":["Company News","ETO STERILIZER"],"inLanguage":"ceb","potentialAction":[{"@type":"CommentAction","name":"Comment","target":["https:\/\/zjbocon.com\/?p=2448#respond"]}]},{"@type":"WebPage","@id":"https:\/\/zjbocon.com\/?p=2448","url":"https:\/\/zjbocon.com\/?p=2448","name":"eto sterilization Chamber Temperature Distribution Testing - ETO STERILIZER","isPartOf":{"@id":"https:\/\/zjbocon.com\/#website"},"primaryImageOfPage":{"@id":"https:\/\/zjbocon.com\/?p=2448#primaryimage"},"image":{"@id":"https:\/\/zjbocon.com\/?p=2448#primaryimage"},"thumbnailUrl":"https:\/\/zjbocon.com\/wp-content\/uploads\/2025\/09\/ethylene-oxide-sterilization-54.webp","datePublished":"2024-12-20T02:40:39+00:00","dateModified":"2025-12-05T02:53:12+00:00","description":"C.1 Temperature Testing of Inner Surfaces in the eto Sterilization Chamber C.2 Temperature Testing of Empty eto Sterilization Chamber","breadcrumb":{"@id":"https:\/\/zjbocon.com\/?p=2448#breadcrumb"},"inLanguage":"ceb","potentialAction":[{"@type":"ReadAction","target":["https:\/\/zjbocon.com\/?p=2448"]}]},{"@type":"ImageObject","inLanguage":"ceb","@id":"https:\/\/zjbocon.com\/?p=2448#primaryimage","url":"https:\/\/zjbocon.com\/wp-content\/uploads\/2025\/09\/ethylene-oxide-sterilization-54.webp","contentUrl":"https:\/\/zjbocon.com\/wp-content\/uploads\/2025\/09\/ethylene-oxide-sterilization-54.webp","width":1279,"height":1706},{"@type":"BreadcrumbList","@id":"https:\/\/zjbocon.com\/?p=2448#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/zjbocon.com\/"},{"@type":"ListItem","position":2,"name":"eto sterilization Chamber Temperature Distribution Testing"}]},{"@type":"WebSite","@id":"https:\/\/zjbocon.com\/#website","url":"https:\/\/zjbocon.com\/","name":"ETO STERILIZER","description":"One-stop Solution Supplier of Ethylene Oxide Sterilization","publisher":{"@id":"https:\/\/zjbocon.com\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/zjbocon.com\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"ceb"},{"@type":"Organization","@id":"https:\/\/zjbocon.com\/#organization","name":"ETO STERILIZER","url":"https:\/\/zjbocon.com\/","logo":{"@type":"ImageObject","inLanguage":"ceb","@id":"https:\/\/zjbocon.com\/#\/schema\/logo\/image\/","url":"https:\/\/zjbocon.com\/wp-content\/uploads\/2024\/10\/logo-1.webp","contentUrl":"https:\/\/zjbocon.com\/wp-content\/uploads\/2024\/10\/logo-1.webp","width":180,"height":60,"caption":"ETO STERILIZER"},"image":{"@id":"https:\/\/zjbocon.com\/#\/schema\/logo\/image\/"},"sameAs":["https:\/\/www.facebook.com\/profile.php?id=100088482339878","https:\/\/x.com\/BoconAnd","https:\/\/www.linkedin.com\/in\/--06a221139\/"]},{"@type":"Person","@id":"https:\/\/zjbocon.com\/#\/schema\/person\/f12be028b8ae9843a4396dcc8012b425","name":"Bocon Technical Team","image":{"@type":"ImageObject","inLanguage":"ceb","@id":"https:\/\/secure.gravatar.com\/avatar\/d7a825658be227f26b237e519f8541e05aabc9ff27b8eec4544a233a48c53be0?s=96&d=identicon&r=g","url":"https:\/\/secure.gravatar.com\/avatar\/d7a825658be227f26b237e519f8541e05aabc9ff27b8eec4544a233a48c53be0?s=96&d=identicon&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/d7a825658be227f26b237e519f8541e05aabc9ff27b8eec4544a233a48c53be0?s=96&d=identicon&r=g","caption":"Bocon Technical Team"},"sameAs":["https:\/\/zjbocon.com\/","https:\/\/www.facebook.com\/profile.php?id=100088482339878","https:\/\/www.linkedin.com\/in\/\/hayley--968190269\/"],"url":"https:\/\/zjbocon.com\/?author=234312599"}]}},"jetpack_publicize_connections":[],"jetpack_featured_media_url":"https:\/\/zjbocon.com\/wp-content\/uploads\/2025\/09\/ethylene-oxide-sterilization-54.webp","uagb_featured_image_src":{"full":["https:\/\/zjbocon.com\/wp-content\/uploads\/2025\/09\/ethylene-oxide-sterilization-54.webp",1279,1706,false],"thumbnail":["https:\/\/zjbocon.com\/wp-content\/uploads\/2025\/09\/ethylene-oxide-sterilization-54-150x150.webp",150,150,true],"medium":["https:\/\/zjbocon.com\/wp-content\/uploads\/2025\/09\/ethylene-oxide-sterilization-54-225x300.webp",225,300,true],"medium_large":["https:\/\/zjbocon.com\/wp-content\/uploads\/2025\/09\/ethylene-oxide-sterilization-54-768x1024.webp",768,1024,true],"large":["https:\/\/zjbocon.com\/wp-content\/uploads\/2025\/09\/ethylene-oxide-sterilization-54-768x1024.webp",768,1024,true],"1536x1536":["https:\/\/zjbocon.com\/wp-content\/uploads\/2025\/09\/ethylene-oxide-sterilization-54-1152x1536.webp",1152,1536,true],"2048x2048":["https:\/\/zjbocon.com\/wp-content\/uploads\/2025\/09\/ethylene-oxide-sterilization-54.webp",1279,1706,false],"woocommerce_thumbnail":["https:\/\/zjbocon.com\/wp-content\/uploads\/2025\/09\/ethylene-oxide-sterilization-54-600x600.webp",600,600,true],"woocommerce_single":["https:\/\/zjbocon.com\/wp-content\/uploads\/2025\/09\/ethylene-oxide-sterilization-54-600x800.webp",600,800,true],"woocommerce_gallery_thumbnail":["https:\/\/zjbocon.com\/wp-content\/uploads\/2025\/09\/ethylene-oxide-sterilization-54-100x100.webp",100,100,true]},"uagb_author_info":{"display_name":"Bocon Technical Team","author_link":"https:\/\/zjbocon.com\/?author=234312599"},"uagb_comment_info":24,"uagb_excerpt":"The temperature of representative areas on the inner surfaces should be measured and recorded using temperature recording instruments that comply with the requirements of Appendix B.","jetpack_likes_enabled":true,"jetpack_sharing_enabled":true,"jetpack_shortlink":"https:\/\/wp.me\/pgZDV6-Du","jetpack-related-posts":[{"id":2492,"url":"https:\/\/zjbocon.com\/?p=2492","url_meta":{"origin":2448,"position":0},"title":"Understanding ETO Sterilizer Performance: Keys to Efficiency","author":"Bocon Technical Team","date":"2024-12-24","format":false,"excerpt":"3.4.1 eto sterilizer machine Temperature Setting Range The temperature setting range for the eto sterilizer is: 30 to 70\u00b0C","rel":"","context":"In &quot;Company News&quot;","block_context":{"text":"Company News","link":"https:\/\/zjbocon.com\/?cat=133125"},"img":{"alt_text":"","src":"https:\/\/i0.wp.com\/zjbocon.com\/wp-content\/uploads\/2025\/09\/eto-sterilizer-1.webp?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/zjbocon.com\/wp-content\/uploads\/2025\/09\/eto-sterilizer-1.webp?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/zjbocon.com\/wp-content\/uploads\/2025\/09\/eto-sterilizer-1.webp?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/zjbocon.com\/wp-content\/uploads\/2025\/09\/eto-sterilizer-1.webp?resize=700%2C400&ssl=1 2x, https:\/\/i0.wp.com\/zjbocon.com\/wp-content\/uploads\/2025\/09\/eto-sterilizer-1.webp?resize=1050%2C600&ssl=1 3x"},"classes":[]},{"id":2064,"url":"https:\/\/zjbocon.com\/?p=2064","url_meta":{"origin":2448,"position":1},"title":"OQ IN ETO STERILIZATION MACHINE","author":"Bocon Technical Team","date":"2024-10-31","format":false,"excerpt":"In OQ, the performance of the relevant auxiliary system should be determined and the software system should be tested by simulating the fault conditions.","rel":"","context":"In &quot;ETO STERILIZER&quot;","block_context":{"text":"ETO STERILIZER","link":"https:\/\/zjbocon.com\/?cat=133124"},"img":{"alt_text":"","src":"https:\/\/i0.wp.com\/zjbocon.com\/wp-content\/uploads\/2025\/09\/Ethylene-Oxide-Sterilizer-Installation-Guide-1-scaled.webp?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/zjbocon.com\/wp-content\/uploads\/2025\/09\/Ethylene-Oxide-Sterilizer-Installation-Guide-1-scaled.webp?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/zjbocon.com\/wp-content\/uploads\/2025\/09\/Ethylene-Oxide-Sterilizer-Installation-Guide-1-scaled.webp?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/zjbocon.com\/wp-content\/uploads\/2025\/09\/Ethylene-Oxide-Sterilizer-Installation-Guide-1-scaled.webp?resize=700%2C400&ssl=1 2x, https:\/\/i0.wp.com\/zjbocon.com\/wp-content\/uploads\/2025\/09\/Ethylene-Oxide-Sterilizer-Installation-Guide-1-scaled.webp?resize=1050%2C600&ssl=1 3x, https:\/\/i0.wp.com\/zjbocon.com\/wp-content\/uploads\/2025\/09\/Ethylene-Oxide-Sterilizer-Installation-Guide-1-scaled.webp?resize=1400%2C800&ssl=1 4x"},"classes":[]},{"id":2138,"url":"https:\/\/zjbocon.com\/?p=2138","url_meta":{"origin":2448,"position":2},"title":"ETO Sterilization Chamber Testing","author":"Bocon Technical Team","date":"2024-11-07","format":false,"excerpt":"The temperature setting range of the ETO Sterilization Chamber should be between 30-60\u00b0C. It is recommended to perform temperature distribution testing of the sterilizer's internal surface and temperature and humidity distribution testing inside the sterilization chamber to ensure the effectiveness of the heating and humidifying systems.","rel":"","context":"In &quot;ETO STERILIZER&quot;","block_context":{"text":"ETO STERILIZER","link":"https:\/\/zjbocon.com\/?cat=133124"},"img":{"alt_text":"","src":"https:\/\/i0.wp.com\/zjbocon.com\/wp-content\/uploads\/2025\/09\/cropped-cropped-hzbocon.png?resize=350%2C200&ssl=1","width":350,"height":200},"classes":[]},{"id":1989,"url":"https:\/\/zjbocon.com\/?p=1989","url_meta":{"origin":2448,"position":3},"title":"The Detail Of EtO Sterilization Cycle\u00a0","author":"Bocon Technical Team","date":"2024-10-25","format":false,"excerpt":"The Detail EtO Sterilization Cycle\u00a0 A typical EtO sterilization cycle comprises three main stages: Preconditioning This stage prepares the chamber to create optimal conditions for temperature, pressure, and humidity. \u00a0First, air is evacuated to enhance gas penetration, followed by a leakage test to ensure safety for personnel and the environment.\u2026","rel":"","context":"In &quot;ETO STERILIZER&quot;","block_context":{"text":"ETO STERILIZER","link":"https:\/\/zjbocon.com\/?cat=133124"},"img":{"alt_text":"","src":"https:\/\/i0.wp.com\/zjbocon.com\/wp-content\/uploads\/2024\/10\/turn-key-solution.webp?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/zjbocon.com\/wp-content\/uploads\/2024\/10\/turn-key-solution.webp?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/zjbocon.com\/wp-content\/uploads\/2024\/10\/turn-key-solution.webp?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/zjbocon.com\/wp-content\/uploads\/2024\/10\/turn-key-solution.webp?resize=700%2C400&ssl=1 2x"},"classes":[]},{"id":1950,"url":"https:\/\/zjbocon.com\/?p=1950","url_meta":{"origin":2448,"position":4},"title":"eto sterilization process","author":"Bocon Technical Team","date":"2024-10-23","format":false,"excerpt":"Eto Sterilization is conducted using a eto sterilizer located in a dedicated facility.","rel":"","context":"In &quot;ETO STERILIZER&quot;","block_context":{"text":"ETO STERILIZER","link":"https:\/\/zjbocon.com\/?cat=133124"},"img":{"alt_text":"eto sterilization process","src":"https:\/\/i0.wp.com\/zjbocon.com\/wp-content\/uploads\/2024\/10\/eto-sterilization-process-e1729654271899.webp?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/zjbocon.com\/wp-content\/uploads\/2024\/10\/eto-sterilization-process-e1729654271899.webp?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/zjbocon.com\/wp-content\/uploads\/2024\/10\/eto-sterilization-process-e1729654271899.webp?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/zjbocon.com\/wp-content\/uploads\/2024\/10\/eto-sterilization-process-e1729654271899.webp?resize=700%2C400&ssl=1 2x"},"classes":[]},{"id":2004,"url":"https:\/\/zjbocon.com\/?p=2004","url_meta":{"origin":2448,"position":5},"title":"The Guide to ethylene oxide in sterilization","author":"Bocon Technical Team","date":"2024-10-28","format":false,"excerpt":"ethylene oxide in sterilization Introduction ETO is a colorless gas that is flammable and explosive. The four essential parameters (operational ranges) of ethylene oxide in sterilization are: gas concentration (450 to 1200 mg\/l); temperature (37 to 63\u00b0C); relative humidity (40 to 80%)(water molecules carry ETO to reactive sites); and exposure\u2026","rel":"","context":"In &quot;ETO STERILIZER&quot;","block_context":{"text":"ETO STERILIZER","link":"https:\/\/zjbocon.com\/?cat=133124"},"img":{"alt_text":"Industry_ETO_Sterilizer","src":"https:\/\/i0.wp.com\/zjbocon.com\/wp-content\/uploads\/2024\/10\/Industry_ETO_Sterilizer.webp?resize=350%2C200","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/zjbocon.com\/wp-content\/uploads\/2024\/10\/Industry_ETO_Sterilizer.webp?resize=350%2C200 1x, https:\/\/i0.wp.com\/zjbocon.com\/wp-content\/uploads\/2024\/10\/Industry_ETO_Sterilizer.webp?resize=525%2C300 1.5x, https:\/\/i0.wp.com\/zjbocon.com\/wp-content\/uploads\/2024\/10\/Industry_ETO_Sterilizer.webp?resize=700%2C400 2x"},"classes":[]}],"_links":{"self":[{"href":"https:\/\/zjbocon.com\/index.php?rest_route=\/wp\/v2\/posts\/2448","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/zjbocon.com\/index.php?rest_route=\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/zjbocon.com\/index.php?rest_route=\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/zjbocon.com\/index.php?rest_route=\/wp\/v2\/users\/234312599"}],"replies":[{"embeddable":true,"href":"https:\/\/zjbocon.com\/index.php?rest_route=%2Fwp%2Fv2%2Fcomments&post=2448"}],"version-history":[{"count":4,"href":"https:\/\/zjbocon.com\/index.php?rest_route=\/wp\/v2\/posts\/2448\/revisions"}],"predecessor-version":[{"id":8864,"href":"https:\/\/zjbocon.com\/index.php?rest_route=\/wp\/v2\/posts\/2448\/revisions\/8864"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/zjbocon.com\/index.php?rest_route=\/wp\/v2\/media\/8460"}],"wp:attachment":[{"href":"https:\/\/zjbocon.com\/index.php?rest_route=%2Fwp%2Fv2%2Fmedia&parent=2448"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/zjbocon.com\/index.php?rest_route=%2Fwp%2Fv2%2Fcategories&post=2448"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/zjbocon.com\/index.php?rest_route=%2Fwp%2Fv2%2Ftags&post=2448"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}