{"id":2471,"date":"2024-12-23T09:49:40","date_gmt":"2024-12-23T01:49:40","guid":{"rendered":"https:\/\/zjbocon.com\/?p=2471"},"modified":"2025-10-01T19:14:06","modified_gmt":"2025-10-01T11:14:06","slug":"safety-requirements-for-using-ethylene-oxide-in-sterilization","status":"publish","type":"post","link":"https:\/\/zjbocon.com\/?p=2471","title":{"rendered":"Safety Requirements for Using Ethylene Oxide in sterilization"},"content":{"rendered":"\n<div class=\"wp-block-uagb-image uagb-block-3a59f9d8 wp-block-uagb-image--layout-default wp-block-uagb-image--effect-static wp-block-uagb-image--align-none\"><figure class=\"wp-block-uagb-image__figure\"><img loading=\"lazy\" decoding=\"async\" src=\"https:\/\/zjbocon.com\/wp-content\/uploads\/2024\/10\/Electrical-Scale.png\" alt=\"\" class=\"uag-image-1673\" width=\"255\" height=\"569\" title=\"Electrical Scale\" role=\"img\" \><\/figure><\/div>\n\n\n\n<ol class=\"wp-block-list\">\n<li>lorsque l&#039;oxyde d&#039;éthylène dans la chambre de stérilisation doit être équipé d&#039;installations de prévention des incendies.<\/li>\n\n\n\n<li>Les bouteilles d&#039;oxyde d&#039;éthylène doivent être stockées séparément dans une pièce sèche et bien ventilée, avec une interdiction stricte de fumer et de flammes nues.<\/li>\n\n\n\n<li>L&#039;éclairage de la chambre de stérilisation doit être antidéflagrant et tout appareil électrique susceptible de provoquer des étincelles électriques doit être évité. Les flammes nues sont strictement interdites.<\/li>\n\n\n\n<li>Avant de stériliser chaque type d&#039;article, les paramètres doivent être confirmés conformément à la norme nationale GB18279-2000.<\/li>\n\n\n\n<li>La section de commande du stérilisateur doit être installée séparément de l&#039;unité principale (voir schéma D.1).<\/li>\n\n\n\n<li>Une fois la phase de déplacement (rinçage) terminée, les articles stérilisés ne doivent pas rester dans la chambre de stérilisation scellée pendant plus de 15 minutes. Dans le cas contraire, la phase de déplacement doit être répétée avant d&#039;ouvrir la porte.<\/li>\n\n\n\n<li>Une fois la stérilisation à l&#039;oxyde d&#039;éthylène terminée, l&#039;air de déplacement doit être traité conformément aux réglementations applicables en matière d&#039;opération de stérilisation. Avant d&#039;ouvrir la porte pour retirer les articles, le ventilateur axial doit être allumé pour assurer la ventilation. Ne retirez pas immédiatement les articles après avoir ouvert la porte pour éviter toute exposition aux gaz résiduels nocifs dans la chambre de stérilisation.<\/li>\n\n\n\n<li><strong>Alerte médicamenteuse :<\/strong> En fonction de la quantité de médicament à administrer, réglez la pression ou le poids. Lorsque la dose requise est atteinte, une alerte sonore retentit. À ce stade, l’opérateur doit immédiatement fermer l’interrupteur du flacon de médicament et la vanne de dosage de l’unité principale.<\/li>\n\n\n\n<li>Les utilisateurs de mélanges gazeux d&#039;oxyde d&#039;éthylène doivent installer un régulateur de pression (installé par l&#039;utilisateur) à la sortie du flacon de médicament pour réduire la pression de sortie du flacon en dessous de 0,4 MPa, empêchant ainsi la haute pression de provoquer des fuites dans la canalisation de dosage.<\/li>\n\n\n\n<li>Avant de débrancher ou d&#039;ouvrir une partie du système d&#039;alimentation en stérilisant, il est nécessaire de nettoyer le système (à l&#039;exception du système d&#039;alimentation du réservoir de gaz).<\/li>\n\n\n\n<li>Si la pression d&#039;air du joint de porte dans la chambre de stérilisation tombe en dessous de 0,45 MPa pendant le processus de stérilisation, l&#039;alimentation en air du joint en caoutchouc doit être coupée et une source de pression de secours doit être connectée pour garantir que le joint en caoutchouc a une pression supérieure à 0,45 MPa. Parallèlement, la procédure de traitement des fuites d&#039;oxyde d&#039;éthylène doit être activée pour évacuer et nettoyer la chambre de stérilisation. Ensuite, des mesures doivent être prises pour restaurer la source d’air d’origine.<\/li>\n\n\n\n<li>Si le système de ventilation du lieu de travail tombe en panne, l&#039;équipement doit être arrêté et non redémarré. Si la panne se produit alors que l&#039;agent stérilisant est déjà entré dans la chambre, l&#039;opérateur ne doit entrer dans la chambre pour contacter les articles stérilisés qu&#039;une fois les procédures de retrait et de rinçage du stérilisant entièrement terminées.<\/li>\n\n\n\n<li>Après chaque cycle de travail, le système de canalisations d&#039;oxyde d&#039;éthylène doit être nettoyé. Les moyens de nettoyage peuvent inclure de l’eau, de l’air comprimé ou de la vapeur. L&#039;utilisateur doit installer des systèmes d&#039;évacuation locaux dans les zones où le gaz stérilisant peut s&#039;accumuler, comme près de la porte du stérilisateur, de la zone de stockage des articles stérilisés et de la zone de stockage du stérilisant. Le système d&#039;échappement ne doit rejeter aucune substance pouvant présenter un danger.<\/li>\n<\/ol>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Note:<\/strong> Que l&#039;équipement soit en fonctionnement normal, en dysfonctionnement ou en état de maintenance, si du personnel doit entrer dans la chambre du stérilisateur, la porte doit être abaissée au sol ou soutenue. Il convient de confirmer que la porte est verrouillée et ne peut pas être fermée. Le personnel doit prendre ou conserver la clé en toute sécurité avant d&#039;entrer dans la chambre.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"h-contact\">Contact<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Téléphone:<a href=\"https:\/\/wa.me\/8619975258603\">+8619975258603<\/a><\/p>\n\n\n\n<p class=\"wp-block-paragraph\">E-mail:<a href=\"mailto:hayley@hzbocon.com\">hayley@hzbocon.com<\/a><\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Site local : salle 1202, Caitong Zhongxin, district de Xiasha, ville de Hangzhou, province du Zhejiang, Chine<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Site web:<a href=\"https:\/\/www.hzbocon.com\/\">hzbocon.com<\/a><a href=\"https:\/\/zjbocon.com\/\">&nbsp;zjbocon.com<\/a><\/p>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"h-know-more-about-us\">En savoir plus sur nous<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\"><a href=\"https:\/\/zjbocon.com\/sterilization-for-spice\/\">Comparaison de la stérilisation ETO, Gamma et vapeur pour les épices<\/a><\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><a href=\"https:\/\/zjbocon.com\/understanding-eto-sterilizer-performance-keys-to-efficiency\/\">Comprendre les performances du stérilisateur ETO : clés de l&#039;efficacité<\/a><\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><a href=\"https:\/\/zjbocon.com\/ethylene-oxide-leak-handling-when-using-eto-sterilizer\/\">Gestion des fuites d&#039;oxyde d&#039;éthylène lors de l&#039;utilisation du stérilisateur eto<\/a><\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><a href=\"https:\/\/zjbocon.com\/safety-requirements-for-using-ethylene-oxide-in-sterilization\/\">Exigences de sécurité pour l&#039;utilisation de l&#039;oxyde d&#039;éthylène en stérilisation<\/a><\/p>\n","protected":false},"excerpt":{"rendered":"<p>Note: Regardless of whether the equipment is in normal operation, malfunction, or maintenance state, if personnel need to enter the [&hellip;]]<\/p>\n","protected":false},"author":234312599,"featured_media":1686,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_uag_custom_page_level_css":"","site-sidebar-layout":"default","site-content-layout":"","ast-site-content-layout":"default","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","ast-disable-related-posts":"","theme-transparent-header-meta":"","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"set","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"_jetpack_newsletter_access":"","_jetpack_dont_email_post_to_subs":false,"_jetpack_newsletter_tier_id":0,"_jetpack_memberships_contains_paywalled_content":false,"_jetpack_feature_clip_id":0,"_jetpack_memberships_contains_paid_content":false,"footnotes":"","jetpack_publicize_message":"","jetpack_publicize_feature_enabled":true,"jetpack_social_post_already_shared":false,"jetpack_social_options":{"image_generator_settings":{"template":"highway","enabled":false},"version":2},"jetpack_post_was_ever_published":false},"categories":[133125,133124],"tags":[],"class_list":["post-2471","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-company-news","category-eto-sterilizer"],"yoast_head":"<!-- This site is optimized with the Yoast SEO Premium plugin v27.2 (Yoast SEO v28.0) - https:\/\/yoast.com\/product\/yoast-seo-premium-wordpress\/ -->\n<title>Exigences de sécurité pour l&#039;utilisation de l&#039;oxyde d&#039;éthylène en stérilisation - ETO STERILIZER<\/title>\n<meta name=\"description\" content=\"The ethylene oxide gas(Ethylene Oxide in sterilization) for the sterilizer should be supplied by dedicated steel cylinders.\" \>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \>\n<link rel=\"canonical\" href=\"https:\/\/zjbocon.com\/?p=2471\" \>\n<meta property=\"og:locale\" content=\"fr_FR\" \>\n<meta property=\"og:type\" content=\"article\" \>\n<meta property=\"og:title\" content=\"Safety Requirements for Using Ethylene Oxide in sterilization\" \>\n<meta property=\"og:description\" content=\"The ethylene oxide gas(Ethylene Oxide in sterilization) for the sterilizer should be supplied by dedicated steel cylinders.\" \>\n<meta property=\"og:url\" content=\"https:\/\/zjbocon.com\/?p=2471\" \>\n<meta property=\"og:site_name\" content=\"ETO STERILIZER\" \>\n<meta property=\"article:publisher\" content=\"https:\/\/www.facebook.com\/profile.php?id=100088482339878\" \>\n<meta property=\"article:author\" content=\"https:\/\/www.facebook.com\/profile.php?id=100088482339878\" \>\n<meta property=\"article:published_time\" content=\"2024-12-23T01:49:40+00:00\" \>\n<meta property=\"article:modified_time\" content=\"2025-10-01T11:14:06+00:00\" \>\n<meta property=\"og:image\" content=\"https:\/\/zjbocon.com\/wp-content\/uploads\/2024\/10\/Electrical-Scale.webp\" \>\n\t<meta property=\"og:image:width\" content=\"255\" \>\n\t<meta property=\"og:image:height\" content=\"569\" \>\n\t<meta property=\"og:image:type\" content=\"image\/webp\" \>\n<meta name=\"author\" content=\"Bocon Technical Team\" \>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \>\n<meta name=\"twitter:creator\" content=\"@BoconAnd\" \>\n<meta name=\"twitter:site\" content=\"@BoconAnd\" \>\n<meta name=\"twitter:label1\" content=\"Written by\" \>\n\t<meta name=\"twitter:data1\" content=\"Bocon Technical Team\" \>\n\t<meta name=\"twitter:label2\" content=\"Est. reading time\" \>\n\t<meta name=\"twitter:data2\" content=\"4 minutes\" \>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\\\/\\\/zjbocon.com\\\/?p=2471#article\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/zjbocon.com\\\/?p=2471\"},\"author\":{\"name\":\"Bocon Technical Team\",\"@id\":\"https:\\\/\\\/zjbocon.com\\\/#\\\/schema\\\/person\\\/f12be028b8ae9843a4396dcc8012b425\"},\"headline\":\"Safety Requirements for Using Ethylene Oxide in sterilization\",\"datePublished\":\"2024-12-23T01:49:40+00:00\",\"dateModified\":\"2025-10-01T11:14:06+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/zjbocon.com\\\/?p=2471\"},\"wordCount\":619,\"commentCount\":0,\"publisher\":{\"@id\":\"https:\\\/\\\/zjbocon.com\\\/#organization\"},\"image\":{\"@id\":\"https:\\\/\\\/zjbocon.com\\\/?p=2471#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/zjbocon.com\\\/wp-content\\\/uploads\\\/2024\\\/10\\\/Electrical-Scale.webp\",\"articleSection\":[\"Company News\",\"ETO STERILIZER\"],\"inLanguage\":\"fr-FR\",\"potentialAction\":[{\"@type\":\"CommentAction\",\"name\":\"Comment\",\"target\":[\"https:\\\/\\\/zjbocon.com\\\/?p=2471#respond\"]}]},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/zjbocon.com\\\/?p=2471\",\"url\":\"https:\\\/\\\/zjbocon.com\\\/?p=2471\",\"name\":\"Safety Requirements for Using Ethylene Oxide in sterilization - ETO STERILIZER\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/zjbocon.com\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/zjbocon.com\\\/?p=2471#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/zjbocon.com\\\/?p=2471#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/zjbocon.com\\\/wp-content\\\/uploads\\\/2024\\\/10\\\/Electrical-Scale.webp\",\"datePublished\":\"2024-12-23T01:49:40+00:00\",\"dateModified\":\"2025-10-01T11:14:06+00:00\",\"description\":\"The ethylene oxide gas(Ethylene Oxide in sterilization) for the sterilizer should be supplied by dedicated ethylene oxide steel cylinders.\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/zjbocon.com\\\/?p=2471#breadcrumb\"},\"inLanguage\":\"fr-FR\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/zjbocon.com\\\/?p=2471\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"fr-FR\",\"@id\":\"https:\\\/\\\/zjbocon.com\\\/?p=2471#primaryimage\",\"url\":\"https:\\\/\\\/zjbocon.com\\\/wp-content\\\/uploads\\\/2024\\\/10\\\/Electrical-Scale.webp\",\"contentUrl\":\"https:\\\/\\\/zjbocon.com\\\/wp-content\\\/uploads\\\/2024\\\/10\\\/Electrical-Scale.webp\",\"width\":255,\"height\":569,\"caption\":\"eo gas\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/zjbocon.com\\\/?p=2471#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/zjbocon.com\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Safety Requirements for Using Ethylene Oxide in sterilization\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/zjbocon.com\\\/#website\",\"url\":\"https:\\\/\\\/zjbocon.com\\\/\",\"name\":\"ETO STERILIZER\",\"description\":\"One-stop Solution Supplier of Ethylene Oxide Sterilization\",\"publisher\":{\"@id\":\"https:\\\/\\\/zjbocon.com\\\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/zjbocon.com\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"fr-FR\"},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/zjbocon.com\\\/#organization\",\"name\":\"ETO STERILIZER\",\"url\":\"https:\\\/\\\/zjbocon.com\\\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"fr-FR\",\"@id\":\"https:\\\/\\\/zjbocon.com\\\/#\\\/schema\\\/logo\\\/image\\\/\",\"url\":\"https:\\\/\\\/zjbocon.com\\\/wp-content\\\/uploads\\\/2024\\\/10\\\/logo-1.webp\",\"contentUrl\":\"https:\\\/\\\/zjbocon.com\\\/wp-content\\\/uploads\\\/2024\\\/10\\\/logo-1.webp\",\"width\":180,\"height\":60,\"caption\":\"ETO STERILIZER\"},\"image\":{\"@id\":\"https:\\\/\\\/zjbocon.com\\\/#\\\/schema\\\/logo\\\/image\\\/\"},\"sameAs\":[\"https:\\\/\\\/www.facebook.com\\\/profile.php?id=100088482339878\",\"https:\\\/\\\/x.com\\\/BoconAnd\",\"https:\\\/\\\/www.linkedin.com\\\/in\\\/--06a221139\\\/\"]},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/zjbocon.com\\\/#\\\/schema\\\/person\\\/f12be028b8ae9843a4396dcc8012b425\",\"name\":\"Bocon Technical Team\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"fr-FR\",\"@id\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/d7a825658be227f26b237e519f8541e05aabc9ff27b8eec4544a233a48c53be0?s=96&d=identicon&r=g\",\"url\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/d7a825658be227f26b237e519f8541e05aabc9ff27b8eec4544a233a48c53be0?s=96&d=identicon&r=g\",\"contentUrl\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/d7a825658be227f26b237e519f8541e05aabc9ff27b8eec4544a233a48c53be0?s=96&d=identicon&r=g\",\"caption\":\"Bocon Technical Team\"},\"sameAs\":[\"https:\\\/\\\/zjbocon.com\\\/\",\"https:\\\/\\\/www.facebook.com\\\/profile.php?id=100088482339878\",\"https:\\\/\\\/www.linkedin.com\\\/in\\\/\\\/hayley--968190269\\\/\"],\"url\":\"https:\\\/\\\/zjbocon.com\\\/?author=234312599\"}]}<\/script>\n<!-- \/ Yoast SEO Premium plugin. -->","yoast_head_json":{"title":"Safety Requirements for Using Ethylene Oxide in sterilization - ETO STERILIZER","description":"The ethylene oxide gas(Ethylene Oxide in sterilization) for the sterilizer should be supplied by dedicated ethylene oxide steel cylinders.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/zjbocon.com\/?p=2471","og_locale":"fr_FR","og_type":"article","og_title":"Safety Requirements for Using Ethylene Oxide in sterilization","og_description":"The ethylene oxide gas(Ethylene Oxide in sterilization) for the sterilizer should be supplied by dedicated ethylene oxide steel cylinders.","og_url":"https:\/\/zjbocon.com\/?p=2471","og_site_name":"ETO STERILIZER","article_publisher":"https:\/\/www.facebook.com\/profile.php?id=100088482339878","article_author":"https:\/\/www.facebook.com\/profile.php?id=100088482339878","article_published_time":"2024-12-23T01:49:40+00:00","article_modified_time":"2025-10-01T11:14:06+00:00","og_image":[{"width":255,"height":569,"url":"https:\/\/zjbocon.com\/wp-content\/uploads\/2024\/10\/Electrical-Scale.webp","type":"image\/webp"}],"author":"Bocon Technical Team","twitter_card":"summary_large_image","twitter_creator":"@BoconAnd","twitter_site":"@BoconAnd","twitter_misc":{"Written by":"Bocon Technical Team","Est. reading time":"4 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/zjbocon.com\/?p=2471#article","isPartOf":{"@id":"https:\/\/zjbocon.com\/?p=2471"},"author":{"name":"Bocon Technical Team","@id":"https:\/\/zjbocon.com\/#\/schema\/person\/f12be028b8ae9843a4396dcc8012b425"},"headline":"Safety Requirements for Using Ethylene Oxide in sterilization","datePublished":"2024-12-23T01:49:40+00:00","dateModified":"2025-10-01T11:14:06+00:00","mainEntityOfPage":{"@id":"https:\/\/zjbocon.com\/?p=2471"},"wordCount":619,"commentCount":0,"publisher":{"@id":"https:\/\/zjbocon.com\/#organization"},"image":{"@id":"https:\/\/zjbocon.com\/?p=2471#primaryimage"},"thumbnailUrl":"https:\/\/zjbocon.com\/wp-content\/uploads\/2024\/10\/Electrical-Scale.webp","articleSection":["Company News","ETO STERILIZER"],"inLanguage":"fr-FR","potentialAction":[{"@type":"CommentAction","name":"Comment","target":["https:\/\/zjbocon.com\/?p=2471#respond"]}]},{"@type":"WebPage","@id":"https:\/\/zjbocon.com\/?p=2471","url":"https:\/\/zjbocon.com\/?p=2471","name":"Safety Requirements for Using Ethylene Oxide in sterilization - ETO STERILIZER","isPartOf":{"@id":"https:\/\/zjbocon.com\/#website"},"primaryImageOfPage":{"@id":"https:\/\/zjbocon.com\/?p=2471#primaryimage"},"image":{"@id":"https:\/\/zjbocon.com\/?p=2471#primaryimage"},"thumbnailUrl":"https:\/\/zjbocon.com\/wp-content\/uploads\/2024\/10\/Electrical-Scale.webp","datePublished":"2024-12-23T01:49:40+00:00","dateModified":"2025-10-01T11:14:06+00:00","description":"The ethylene oxide gas(Ethylene Oxide in sterilization) for the sterilizer should be supplied by dedicated ethylene oxide steel cylinders.","breadcrumb":{"@id":"https:\/\/zjbocon.com\/?p=2471#breadcrumb"},"inLanguage":"fr-FR","potentialAction":[{"@type":"ReadAction","target":["https:\/\/zjbocon.com\/?p=2471"]}]},{"@type":"ImageObject","inLanguage":"fr-FR","@id":"https:\/\/zjbocon.com\/?p=2471#primaryimage","url":"https:\/\/zjbocon.com\/wp-content\/uploads\/2024\/10\/Electrical-Scale.webp","contentUrl":"https:\/\/zjbocon.com\/wp-content\/uploads\/2024\/10\/Electrical-Scale.webp","width":255,"height":569,"caption":"eo gas"},{"@type":"BreadcrumbList","@id":"https:\/\/zjbocon.com\/?p=2471#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/zjbocon.com\/"},{"@type":"ListItem","position":2,"name":"Safety Requirements for Using Ethylene Oxide in sterilization"}]},{"@type":"WebSite","@id":"https:\/\/zjbocon.com\/#website","url":"https:\/\/zjbocon.com\/","name":"ETO STERILIZER","description":"One-stop Solution Supplier of Ethylene Oxide Sterilization","publisher":{"@id":"https:\/\/zjbocon.com\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/zjbocon.com\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"fr-FR"},{"@type":"Organization","@id":"https:\/\/zjbocon.com\/#organization","name":"ETO STERILIZER","url":"https:\/\/zjbocon.com\/","logo":{"@type":"ImageObject","inLanguage":"fr-FR","@id":"https:\/\/zjbocon.com\/#\/schema\/logo\/image\/","url":"https:\/\/zjbocon.com\/wp-content\/uploads\/2024\/10\/logo-1.webp","contentUrl":"https:\/\/zjbocon.com\/wp-content\/uploads\/2024\/10\/logo-1.webp","width":180,"height":60,"caption":"ETO STERILIZER"},"image":{"@id":"https:\/\/zjbocon.com\/#\/schema\/logo\/image\/"},"sameAs":["https:\/\/www.facebook.com\/profile.php?id=100088482339878","https:\/\/x.com\/BoconAnd","https:\/\/www.linkedin.com\/in\/--06a221139\/"]},{"@type":"Person","@id":"https:\/\/zjbocon.com\/#\/schema\/person\/f12be028b8ae9843a4396dcc8012b425","name":"Bocon Technical Team","image":{"@type":"ImageObject","inLanguage":"fr-FR","@id":"https:\/\/secure.gravatar.com\/avatar\/d7a825658be227f26b237e519f8541e05aabc9ff27b8eec4544a233a48c53be0?s=96&d=identicon&r=g","url":"https:\/\/secure.gravatar.com\/avatar\/d7a825658be227f26b237e519f8541e05aabc9ff27b8eec4544a233a48c53be0?s=96&d=identicon&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/d7a825658be227f26b237e519f8541e05aabc9ff27b8eec4544a233a48c53be0?s=96&d=identicon&r=g","caption":"Bocon Technical Team"},"sameAs":["https:\/\/zjbocon.com\/","https:\/\/www.facebook.com\/profile.php?id=100088482339878","https:\/\/www.linkedin.com\/in\/\/hayley--968190269\/"],"url":"https:\/\/zjbocon.com\/?author=234312599"}]}},"jetpack_publicize_connections":[],"jetpack_featured_media_url":"https:\/\/zjbocon.com\/wp-content\/uploads\/2024\/10\/Electrical-Scale.webp","uagb_featured_image_src":{"full":["https:\/\/zjbocon.com\/wp-content\/uploads\/2024\/10\/Electrical-Scale.webp",255,569,false],"thumbnail":["https:\/\/zjbocon.com\/wp-content\/uploads\/2024\/10\/Electrical-Scale-150x150.webp",150,150,true],"medium":["https:\/\/zjbocon.com\/wp-content\/uploads\/2024\/10\/Electrical-Scale-134x300.webp",134,300,true],"medium_large":["https:\/\/zjbocon.com\/wp-content\/uploads\/2024\/10\/Electrical-Scale.webp",255,569,false],"large":["https:\/\/zjbocon.com\/wp-content\/uploads\/2024\/10\/Electrical-Scale.webp",255,569,false],"1536x1536":["https:\/\/zjbocon.com\/wp-content\/uploads\/2024\/10\/Electrical-Scale.webp",255,569,false],"2048x2048":["https:\/\/zjbocon.com\/wp-content\/uploads\/2024\/10\/Electrical-Scale.webp",255,569,false],"woocommerce_thumbnail":["https:\/\/zjbocon.com\/wp-content\/uploads\/2024\/10\/Electrical-Scale.webp",255,569,false],"woocommerce_single":["https:\/\/zjbocon.com\/wp-content\/uploads\/2024\/10\/Electrical-Scale.webp",255,569,false],"woocommerce_gallery_thumbnail":["https:\/\/zjbocon.com\/wp-content\/uploads\/2024\/10\/Electrical-Scale-100x100.webp",100,100,true]},"uagb_author_info":{"display_name":"Bocon Technical Team","author_link":"https:\/\/zjbocon.com\/?author=234312599"},"uagb_comment_info":0,"uagb_excerpt":"Note: Regardless of whether the equipment is in normal operation, malfunction, or maintenance state, if personnel need to enter the [&hellip;]","jetpack_likes_enabled":true,"jetpack_sharing_enabled":true,"jetpack_shortlink":"https:\/\/wp.me\/pgZDV6-DR","jetpack-related-posts":[{"id":2476,"url":"https:\/\/zjbocon.com\/?p=2476","url_meta":{"origin":2471,"position":0},"title":"Ethylene Oxide Leak Handling when using eto sterilizer","author":"Bocon Technical Team","date":"2024-12-23","format":false,"excerpt":"If a leak is detected in the eto sterilizer dosing pipeline during the administration process, immediately close the medication bottle, switch and the dosing valve on the main unit. Turn on the axial fan to ensure proper ventilation, and then proceed with repairs.","rel":"","context":"In &quot;Company News&quot;","block_context":{"text":"Company News","link":"https:\/\/zjbocon.com\/?cat=133125"},"img":{"alt_text":"","src":"https:\/\/i0.wp.com\/zjbocon.com\/wp-content\/uploads\/2025\/09\/ethylene-oxide-sterilization-19-scaled.webp?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/zjbocon.com\/wp-content\/uploads\/2025\/09\/ethylene-oxide-sterilization-19-scaled.webp?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/zjbocon.com\/wp-content\/uploads\/2025\/09\/ethylene-oxide-sterilization-19-scaled.webp?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/zjbocon.com\/wp-content\/uploads\/2025\/09\/ethylene-oxide-sterilization-19-scaled.webp?resize=700%2C400&ssl=1 2x, https:\/\/i0.wp.com\/zjbocon.com\/wp-content\/uploads\/2025\/09\/ethylene-oxide-sterilization-19-scaled.webp?resize=1050%2C600&ssl=1 3x, https:\/\/i0.wp.com\/zjbocon.com\/wp-content\/uploads\/2025\/09\/ethylene-oxide-sterilization-19-scaled.webp?resize=1400%2C800&ssl=1 4x"},"classes":[]},{"id":8958,"url":"https:\/\/zjbocon.com\/?p=8958","url_meta":{"origin":2471,"position":1},"title":"Understanding What is ETO Sterilizers: A Comprehensive Guide","author":"Bocon Technical Team","date":"2025-12-16","format":false,"excerpt":"Discover the essentials of ETO sterilizers and ethylene oxide sterilization, ensuring the highest hygiene standards in healthcare and beyond.","rel":"","context":"In &quot;Company News&quot;","block_context":{"text":"Company News","link":"https:\/\/zjbocon.com\/?cat=133125"},"img":{"alt_text":"","src":"https:\/\/i0.wp.com\/zjbocon.com\/wp-content\/uploads\/2024\/11\/eto-sterilizer-hzbocon-3.png?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/zjbocon.com\/wp-content\/uploads\/2024\/11\/eto-sterilizer-hzbocon-3.png?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/zjbocon.com\/wp-content\/uploads\/2024\/11\/eto-sterilizer-hzbocon-3.png?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/zjbocon.com\/wp-content\/uploads\/2024\/11\/eto-sterilizer-hzbocon-3.png?resize=700%2C400&ssl=1 2x, https:\/\/i0.wp.com\/zjbocon.com\/wp-content\/uploads\/2024\/11\/eto-sterilizer-hzbocon-3.png?resize=1050%2C600&ssl=1 3x"},"classes":[]},{"id":3093,"url":"https:\/\/zjbocon.com\/?p=3093","url_meta":{"origin":2471,"position":2},"title":"Introduction to Ethylene Oxide Sterilizers","author":"Bocon Technical Team","date":"2025-02-05","format":false,"excerpt":"Discover how ethylene oxide sterilizers work, their applications, benefits, and safety considerations. Learn why they are essential for medical and industrial sterilization.","rel":"","context":"In &quot;Company News&quot;","block_context":{"text":"Company News","link":"https:\/\/zjbocon.com\/?cat=133125"},"img":{"alt_text":"","src":"https:\/\/i0.wp.com\/zjbocon.com\/wp-content\/uploads\/2024\/11\/ethylene-oxide-sterilization-21.webp?resize=350%2C200","width":350,"height":200},"classes":[]},{"id":2453,"url":"https:\/\/zjbocon.com\/?p=2453","url_meta":{"origin":2471,"position":3},"title":"Microbial Killing Performance of Ethylene Oxide Sterilizers","author":"Bocon Technical Team","date":"2024-12-20","format":false,"excerpt":"Note 1: The Ethylene Oxide sterilization conditions must be obtained through validation confirmation and should be verified with monitoring and routine control during each sterilization cycle. The requirements for validation and routine control are outlined in GB 18279. Note 2: This testing method is also applicable to A class Ethylene\u2026","rel":"","context":"In &quot;Company News&quot;","block_context":{"text":"Company News","link":"https:\/\/zjbocon.com\/?cat=133125"},"img":{"alt_text":"eto sterilizer","src":"https:\/\/i0.wp.com\/zjbocon.com\/wp-content\/uploads\/2024\/10\/banner__.webp?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/zjbocon.com\/wp-content\/uploads\/2024\/10\/banner__.webp?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/zjbocon.com\/wp-content\/uploads\/2024\/10\/banner__.webp?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/zjbocon.com\/wp-content\/uploads\/2024\/10\/banner__.webp?resize=700%2C400&ssl=1 2x"},"classes":[]},{"id":2448,"url":"https:\/\/zjbocon.com\/?p=2448","url_meta":{"origin":2471,"position":4},"title":"eto sterilization Chamber Temperature Distribution Testing","author":"Bocon Technical Team","date":"2024-12-20","format":false,"excerpt":"The temperature of representative areas on the inner surfaces should be measured and recorded using temperature recording instruments that comply with the requirements of Appendix B.","rel":"","context":"In &quot;Company News&quot;","block_context":{"text":"Company News","link":"https:\/\/zjbocon.com\/?cat=133125"},"img":{"alt_text":"","src":"https:\/\/i0.wp.com\/zjbocon.com\/wp-content\/uploads\/2025\/09\/ethylene-oxide-sterilization-54.webp?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/zjbocon.com\/wp-content\/uploads\/2025\/09\/ethylene-oxide-sterilization-54.webp?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/zjbocon.com\/wp-content\/uploads\/2025\/09\/ethylene-oxide-sterilization-54.webp?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/zjbocon.com\/wp-content\/uploads\/2025\/09\/ethylene-oxide-sterilization-54.webp?resize=700%2C400&ssl=1 2x, https:\/\/i0.wp.com\/zjbocon.com\/wp-content\/uploads\/2025\/09\/ethylene-oxide-sterilization-54.webp?resize=1050%2C600&ssl=1 3x"},"classes":[]},{"id":2439,"url":"https:\/\/zjbocon.com\/?p=2439","url_meta":{"origin":2471,"position":5},"title":"Preparatory Work Before eto Sterilization","author":"Bocon Technical Team","date":"2024-12-17","format":false,"excerpt":"Appearance Inspection: Check the main unit, control rack, and electrical control cabinet for any damage on the surface.","rel":"","context":"In &quot;Company News&quot;","block_context":{"text":"Company News","link":"https:\/\/zjbocon.com\/?cat=133125"},"img":{"alt_text":"","src":"https:\/\/i0.wp.com\/zjbocon.com\/wp-content\/uploads\/2025\/09\/sterilizer-station-design-2.webp?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/zjbocon.com\/wp-content\/uploads\/2025\/09\/sterilizer-station-design-2.webp?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/zjbocon.com\/wp-content\/uploads\/2025\/09\/sterilizer-station-design-2.webp?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/zjbocon.com\/wp-content\/uploads\/2025\/09\/sterilizer-station-design-2.webp?resize=700%2C400&ssl=1 2x"},"classes":[]}],"_links":{"self":[{"href":"https:\/\/zjbocon.com\/index.php?rest_route=\/wp\/v2\/posts\/2471","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/zjbocon.com\/index.php?rest_route=\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/zjbocon.com\/index.php?rest_route=\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/zjbocon.com\/index.php?rest_route=\/wp\/v2\/users\/234312599"}],"replies":[{"embeddable":true,"href":"https:\/\/zjbocon.com\/index.php?rest_route=%2Fwp%2Fv2%2Fcomments&post=2471"}],"version-history":[{"count":5,"href":"https:\/\/zjbocon.com\/index.php?rest_route=\/wp\/v2\/posts\/2471\/revisions"}],"predecessor-version":[{"id":2499,"href":"https:\/\/zjbocon.com\/index.php?rest_route=\/wp\/v2\/posts\/2471\/revisions\/2499"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/zjbocon.com\/index.php?rest_route=\/wp\/v2\/media\/1686"}],"wp:attachment":[{"href":"https:\/\/zjbocon.com\/index.php?rest_route=%2Fwp%2Fv2%2Fmedia&parent=2471"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/zjbocon.com\/index.php?rest_route=%2Fwp%2Fv2%2Fcategories&post=2471"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/zjbocon.com\/index.php?rest_route=%2Fwp%2Fv2%2Ftags&post=2471"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}