{"id":2018,"date":"2024-10-28T11:23:57","date_gmt":"2024-10-28T03:23:57","guid":{"rendered":"https:\/\/zjbocon.com\/?p=2018"},"modified":"2024-11-06T14:09:44","modified_gmt":"2024-11-06T06:09:44","slug":"eto-sterilizer-system","status":"publish","type":"post","link":"https:\/\/zjbocon.com\/?p=2018","title":{"rendered":"Protection function OF eTO chamber SYSTEM"},"content":{"rendered":"\n<p class=\"wp-block-paragraph\"> <\/p>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"h-protection-mechanism-and-explanation-of-eto-sterilizer-system\">Az ETO sterilizáló rendszer védelmi mechanizmusa és magyarázata<\/h2>\n\n\n\n<div class=\"wp-block-uagb-image uagb-block-dba6a8eb wp-block-uagb-image--layout-default wp-block-uagb-image--effect-static wp-block-uagb-image--align-none\"><figure class=\"wp-block-uagb-image__figure\"><a class=\"\" href=\"https:\/\/zjbocon.com\/product\/sterilizer-control-system\/\" target=\"\" rel=\"noopener\"><img loading=\"lazy\" decoding=\"async\" src=\"https:\/\/zjbocon.com\/wp-content\/uploads\/2024\/10\/Ethylene-Oxide-Sterilizer-Control-System-5.webp\" alt=\"Ethylene Oxide Sterilizer Control System (5)\" class=\"uag-image-1277\" width=\"616\" height=\"786\" title=\"Ethylene role =\"img\" \><\/a><\/figure><\/div>\n\n\n\n<ol class=\"wp-block-list\">\n<li>Az ETO sterilizáló rendszer hat különböző szintű működési engedéllyel rendelkezik. A különböző jogosultságokkal rendelkező személyzet különböző tartalmakat kezelhet, hogy elkerülje a működési zavarokat, a berendezés meghibásodását vagy biztonsági balesetét, amelyet szakmai képzettséggel nem rendelkező személyzet okoz.<\/li>\n<\/ol>\n\n\n\n<p class=\"wp-block-paragraph\">2. Alapértelmezés szerint a rendszer minden egyes tétel adagolása előtt elvégzi a szivárgásérzékelési tesztet. Ha a szivárgásérzékelési teszt sikertelen, a rendszer automatikusan leállítja a ciklust, és nem folytatja tovább, és a riasztás jelzi<\/p>\n\n\n\n<div class=\"wp-block-uagb-image uagb-block-1cf2e572 wp-block-uagb-image--layout-default wp-block-uagb-image--effect-static wp-block-uagb-image--align-none\"><figure class=\"wp-block-uagb-image__figure\"><img loading=\"lazy\" decoding=\"async\" src=\"https:\/\/zjbocon.com\/wp-content\/uploads\/2024\/10\/4.-leak-testing.webp\" alt=\"\" class=\"uag-image-1015\" width=\"719\" height=\"544\" title=\"4. leak testing\" role=\"img\" \><\/figure><\/div>\n\n\n\n<p class=\"wp-block-paragraph\">3. Ha a szekrénytest szivárog a berendezés expozíciós szakaszában, az ETO kamrarendszer automatikusan a tisztítási szakaszba ugrik, hogy biztosítsa, hogy az EO ne szivárogjon be a műhelybe, és ne okozzon biztonsági baleseteket<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">4. Ha a berendezés működés közben félúton le akarja állítani a ciklust, a rendszer automatikusan egy biztonságos feldolgozási folyamatra ugrik a különböző működési feltételeknek megfelelően. Például az adagolás után a rendszert kényszertisztításra szorul az egész folyamat visszaállításához.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">5. Ha a rendszer fel van szerelve elektronikus mérleggel, amíg a berendezés be van kapcsolva, bármikor ellenőrizheti, hogy az EO-henger súlya nem változik-e rendellenesen, hogy időben értesítse a berendezés karbantartó személyzetét a lehetséges biztonsági veszélyekről.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">6. Az ETO kamrarendszer ultramagas nyomásérzékelő és védelem funkciója. Ha a rendszer azt észleli, hogy a szekrényben a nyomás meghaladja a maximálisan megengedett nyomást, függetlenül attól, hogy a berendezés működik-e vagy sem, a vákuumszivattyút kényszeríteni kell, hogy elindítsa a szekrényben lévő nyomás csökkentését, hogy megakadályozza a szekrényben lévő gáz beszivárgását a műhelybe, ellenkező esetben a szekrényben lévő magas nyomás károsítja a szekrényt.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">7. Minden alkalommal, amikor kinyitják az ajtót, az ETO kamrarendszer ellenőrzi, hogy a nyomás a szekrényben a biztonságos tartományon belül van-e, és hogy a szekrény működési állapota biztonságos állapotban van-e, ellenkező esetben az ajtó bezárul és nem nyitható<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">8. A személyi biztonság érdekében a berendezést ártalmatlan kipufogórendszerrel lehet felszerelni. A szekrény ajtajának kinyitása után győződjön meg arról, hogy a műhelyben lévő levegő csak a szekrénybe juthat, de nem kerülhet ki a szekrényből a műhely környezetébe<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">9. Ha a berendezést megtisztították, de az ajtót nem nyitották ki, a rendszer automatikusan ellenőrzi a kirakodási időtúllépést. Ha a kirakodási időtúllépés több mint 30 perc, az ajtó bezárul és nem nyitható, és a tisztítási folyamatot újra el kell végezni. Ez a funkció annak biztosítására szolgál, hogy a termékben lévő EO ne kerüljön lassan a műhely környezetébe, ami a műhely környezetének szennyezését és személyi egészségkárosodást okoz.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">10. Az egész vezérlőrendszer öndiagnosztikai funkcióval rendelkezik mindenféle berendezéshez és érzékelőhöz, amely megakadályozza a berendezés rendellenes működését érzékelő meghibásodása esetén, és egyúttal jelzi a karbantartó személyzetnek, hogy melyik érzékelő vagy berendezés hibásodott meg, hogy a karbantartó személyzet gyorsan megtalálja és megoldja a problémákat<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">11. Az ETO sterilizáló RENDSZER több mint 100 hiba- és riasztási információval rendelkezik, amelyek lehetővé teszik a kezelők és a karbantartó személyzet számára, hogy időben és pontosan megismerjék a berendezés működését, hogy a karbantartó személyzet gyorsan megtalálja és megoldja a problémákat.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">12. A folyamatparaméterek letöltése után, ha ésszerűtlen paraméterek vannak, a letöltés meghiúsulását jelzi, hogy megakadályozza a teljes köteg működésének meghibásodását, ha a paraméterek indokolatlanok.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">13. A folyamatparaméterek letöltése után, ha ésszerűtlen paraméterek vannak, a letöltés meghiúsulását jelzi, hogy megakadályozza a teljes köteg működésének meghibásodását, ha a paraméterek indokolatlanok.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">14. A külső tápellátás megszakadása esetén a szünetmentes tápegység továbbra is táplálja a rendszert, és a berendezés kezeli a felfüggesztett állapotot annak érdekében, hogy a berendezés áramszünet után ne szivárogjon, és legalább 15 perces biztonsági pufferidőt biztosítson. Miután a berendezést a normál működési folyamat során leállították, a berendezés továbbra is működhet, ha a külső áramellátás helyreáll<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">15. Ha az IPC meghibásodik a rendszer működése során, az IPC közvetlenül újraindítható, és a szoftver automatikusan csatlakoztatni tudja az eredeti rekordot<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">16. A rendszer részletes auditkövető funkcióval rendelkezik, amely szinte minden műveleti műveletet képes rögzíteni a balesetelemzés és a későbbi hibaelhárítás kényelme érdekében<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"h-contact\">Érintkezés<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Telefon:<a href=\"https:\/\/wa.me\/8619975258603\">+8619975258603<\/a><\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Email:<a href=\"mailto:hayley@hzbocon.com\">hayley@hzbocon.com<\/a><\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Helyi telephely: 1202-es szoba, Caitong Zhongxin, Xiasha kerület, Hangzhou város, Zhejiang tartomány, Kína<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Weboldal:<a href=\"https:\/\/www.hzbocon.com\/\">hzbocon.com<\/a><a href=\"https:\/\/zjbocon.com\/\">zjbocon.com<\/a><\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><\/p>\n","protected":false},"excerpt":{"rendered":"<p>Protection mechanism and explanation OF ETO Sterilizer System 2. By default, the system will perform the leak detection test before [&hellip;]<\/p>\n","protected":false},"author":234312599,"featured_media":1889,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_uag_custom_page_level_css":"","site-sidebar-layout":"default","site-content-layout":"","ast-site-content-layout":"default","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","ast-disable-related-posts":"","theme-transparent-header-meta":"","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"set","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"_jetpack_newsletter_access":"","_jetpack_dont_email_post_to_subs":false,"_jetpack_newsletter_tier_id":0,"_jetpack_memberships_contains_paywalled_content":false,"_jetpack_feature_clip_id":0,"_jetpack_memberships_contains_paid_content":false,"footnotes":"","jetpack_publicize_message":"","jetpack_publicize_feature_enabled":true,"jetpack_social_post_already_shared":false,"jetpack_social_options":{"image_generator_settings":{"template":"highway","enabled":false},"version":2},"jetpack_post_was_ever_published":false},"categories":[133124],"tags":[],"class_list":["post-2018","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-eto-sterilizer"],"yoast_head":"<!-- This site is optimized with the Yoast SEO Premium plugin v27.2 (Yoast SEO v28.0) - https:\/\/yoast.com\/product\/yoast-seo-premium-wordpress\/ -->\n<title>AZ eTO kamra RENDSZER védelmi funkciója - ETO STERILIZÁTOR<\/title>\n<meta name=\"description\" content=\"ETO chamber System (The ETO sterilizer system )has six different levels of operation permissions. Personnel with permissions\" \>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \>\n<link rel=\"canonical\" href=\"https:\/\/zjbocon.com\/?p=2018\" \>\n<meta property=\"og:locale\" content=\"hu_HU\" \>\n<meta property=\"og:type\" content=\"article\" \>\n<meta property=\"og:title\" content=\"Protection function OF eTO chamber SYSTEM\" \>\n<meta property=\"og:description\" content=\"ETO chamber System (The ETO sterilizer system )has six different levels of operation permissions. Personnel with permissions\" \>\n<meta property=\"og:url\" content=\"https:\/\/zjbocon.com\/?p=2018\" \>\n<meta property=\"og:site_name\" content=\"ETO STERILIZER\" \>\n<meta property=\"article:publisher\" content=\"https:\/\/www.facebook.com\/profile.php?id=100088482339878\" \>\n<meta property=\"article:author\" content=\"https:\/\/www.facebook.com\/profile.php?id=100088482339878\" \>\n<meta property=\"article:published_time\" content=\"2024-10-28T03:23:57+00:00\" \>\n<meta property=\"article:modified_time\" content=\"2024-11-06T06:09:44+00:00\" \>\n<meta property=\"og:image\" content=\"https:\/\/zjbocon.com\/wp-content\/uploads\/2024\/10\/customer_5.webp\" \>\n\t<meta property=\"og:image:width\" content=\"300\" \>\n\t<meta property=\"og:image:height\" content=\"200\" \>\n\t<meta property=\"og:image:type\" content=\"image\/webp\" \>\n<meta name=\"author\" content=\"Bocon Technical Team\" \>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \>\n<meta name=\"twitter:creator\" content=\"@BoconAnd\" \>\n<meta name=\"twitter:site\" content=\"@BoconAnd\" \>\n<meta name=\"twitter:label1\" content=\"Written by\" \>\n\t<meta name=\"twitter:data1\" content=\"Bocon Technical Team\" \>\n\t<meta name=\"twitter:label2\" content=\"Est. reading time\" \>\n\t<meta name=\"twitter:data2\" content=\"4 minutes\" \>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\\\/\\\/zjbocon.com\\\/?p=2018#article\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/zjbocon.com\\\/?p=2018\"},\"author\":{\"name\":\"Bocon Technical Team\",\"@id\":\"https:\\\/\\\/zjbocon.com\\\/#\\\/schema\\\/person\\\/f12be028b8ae9843a4396dcc8012b425\"},\"headline\":\"Protection function OF eTO chamber SYSTEM\",\"datePublished\":\"2024-10-28T03:23:57+00:00\",\"dateModified\":\"2024-11-06T06:09:44+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/zjbocon.com\\\/?p=2018\"},\"wordCount\":765,\"commentCount\":0,\"publisher\":{\"@id\":\"https:\\\/\\\/zjbocon.com\\\/#organization\"},\"image\":{\"@id\":\"https:\\\/\\\/zjbocon.com\\\/?p=2018#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/zjbocon.com\\\/wp-content\\\/uploads\\\/2024\\\/10\\\/customer_5.webp\",\"articleSection\":[\"ETO STERILIZER\"],\"inLanguage\":\"hu-HU\",\"potentialAction\":[{\"@type\":\"CommentAction\",\"name\":\"Comment\",\"target\":[\"https:\\\/\\\/zjbocon.com\\\/?p=2018#respond\"]}]},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/zjbocon.com\\\/?p=2018\",\"url\":\"https:\\\/\\\/zjbocon.com\\\/?p=2018\",\"name\":\"Protection function OF eTO chamber SYSTEM - ETO STERILIZER\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/zjbocon.com\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/zjbocon.com\\\/?p=2018#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/zjbocon.com\\\/?p=2018#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/zjbocon.com\\\/wp-content\\\/uploads\\\/2024\\\/10\\\/customer_5.webp\",\"datePublished\":\"2024-10-28T03:23:57+00:00\",\"dateModified\":\"2024-11-06T06:09:44+00:00\",\"description\":\"ETO chamber System (The ETO sterilizer system )has six different levels of operation permissions. Personnel with different permissions\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/zjbocon.com\\\/?p=2018#breadcrumb\"},\"inLanguage\":\"hu-HU\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/zjbocon.com\\\/?p=2018\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"hu-HU\",\"@id\":\"https:\\\/\\\/zjbocon.com\\\/?p=2018#primaryimage\",\"url\":\"https:\\\/\\\/zjbocon.com\\\/wp-content\\\/uploads\\\/2024\\\/10\\\/customer_5.webp\",\"contentUrl\":\"https:\\\/\\\/zjbocon.com\\\/wp-content\\\/uploads\\\/2024\\\/10\\\/customer_5.webp\",\"width\":300,\"height\":200},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/zjbocon.com\\\/?p=2018#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/zjbocon.com\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Protection function OF eTO chamber SYSTEM\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/zjbocon.com\\\/#website\",\"url\":\"https:\\\/\\\/zjbocon.com\\\/\",\"name\":\"ETO STERILIZER\",\"description\":\"One-stop Solution Supplier of Ethylene Oxide Sterilization\",\"publisher\":{\"@id\":\"https:\\\/\\\/zjbocon.com\\\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/zjbocon.com\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"hu-HU\"},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/zjbocon.com\\\/#organization\",\"name\":\"ETO STERILIZER\",\"url\":\"https:\\\/\\\/zjbocon.com\\\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"hu-HU\",\"@id\":\"https:\\\/\\\/zjbocon.com\\\/#\\\/schema\\\/logo\\\/image\\\/\",\"url\":\"https:\\\/\\\/zjbocon.com\\\/wp-content\\\/uploads\\\/2024\\\/10\\\/logo-1.webp\",\"contentUrl\":\"https:\\\/\\\/zjbocon.com\\\/wp-content\\\/uploads\\\/2024\\\/10\\\/logo-1.webp\",\"width\":180,\"height\":60,\"caption\":\"ETO STERILIZER\"},\"image\":{\"@id\":\"https:\\\/\\\/zjbocon.com\\\/#\\\/schema\\\/logo\\\/image\\\/\"},\"sameAs\":[\"https:\\\/\\\/www.facebook.com\\\/profile.php?id=100088482339878\",\"https:\\\/\\\/x.com\\\/BoconAnd\",\"https:\\\/\\\/www.linkedin.com\\\/in\\\/--06a221139\\\/\"]},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/zjbocon.com\\\/#\\\/schema\\\/person\\\/f12be028b8ae9843a4396dcc8012b425\",\"name\":\"Bocon Technical Team\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"hu-HU\",\"@id\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/d7a825658be227f26b237e519f8541e05aabc9ff27b8eec4544a233a48c53be0?s=96&d=identicon&r=g\",\"url\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/d7a825658be227f26b237e519f8541e05aabc9ff27b8eec4544a233a48c53be0?s=96&d=identicon&r=g\",\"contentUrl\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/d7a825658be227f26b237e519f8541e05aabc9ff27b8eec4544a233a48c53be0?s=96&d=identicon&r=g\",\"caption\":\"Bocon Technical Team\"},\"sameAs\":[\"https:\\\/\\\/zjbocon.com\\\/\",\"https:\\\/\\\/www.facebook.com\\\/profile.php?id=100088482339878\",\"https:\\\/\\\/www.linkedin.com\\\/in\\\/\\\/hayley--968190269\\\/\"],\"url\":\"https:\\\/\\\/zjbocon.com\\\/?author=234312599\"}]}<\/script>\n<!-- \/ Yoast SEO Premium plugin. -->","yoast_head_json":{"title":"Protection function OF eTO chamber SYSTEM - ETO STERILIZER","description":"ETO chamber System (The ETO sterilizer system )has six different levels of operation permissions. Personnel with different permissions","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/zjbocon.com\/?p=2018","og_locale":"hu_HU","og_type":"article","og_title":"Protection function OF eTO chamber SYSTEM","og_description":"ETO chamber System (The ETO sterilizer system )has six different levels of operation permissions. Personnel with different permissions","og_url":"https:\/\/zjbocon.com\/?p=2018","og_site_name":"ETO STERILIZER","article_publisher":"https:\/\/www.facebook.com\/profile.php?id=100088482339878","article_author":"https:\/\/www.facebook.com\/profile.php?id=100088482339878","article_published_time":"2024-10-28T03:23:57+00:00","article_modified_time":"2024-11-06T06:09:44+00:00","og_image":[{"width":300,"height":200,"url":"https:\/\/zjbocon.com\/wp-content\/uploads\/2024\/10\/customer_5.webp","type":"image\/webp"}],"author":"Bocon Technical Team","twitter_card":"summary_large_image","twitter_creator":"@BoconAnd","twitter_site":"@BoconAnd","twitter_misc":{"Written by":"Bocon Technical Team","Est. reading time":"4 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/zjbocon.com\/?p=2018#article","isPartOf":{"@id":"https:\/\/zjbocon.com\/?p=2018"},"author":{"name":"Bocon Technical Team","@id":"https:\/\/zjbocon.com\/#\/schema\/person\/f12be028b8ae9843a4396dcc8012b425"},"headline":"Protection function OF eTO chamber SYSTEM","datePublished":"2024-10-28T03:23:57+00:00","dateModified":"2024-11-06T06:09:44+00:00","mainEntityOfPage":{"@id":"https:\/\/zjbocon.com\/?p=2018"},"wordCount":765,"commentCount":0,"publisher":{"@id":"https:\/\/zjbocon.com\/#organization"},"image":{"@id":"https:\/\/zjbocon.com\/?p=2018#primaryimage"},"thumbnailUrl":"https:\/\/zjbocon.com\/wp-content\/uploads\/2024\/10\/customer_5.webp","articleSection":["ETO STERILIZER"],"inLanguage":"hu-HU","potentialAction":[{"@type":"CommentAction","name":"Comment","target":["https:\/\/zjbocon.com\/?p=2018#respond"]}]},{"@type":"WebPage","@id":"https:\/\/zjbocon.com\/?p=2018","url":"https:\/\/zjbocon.com\/?p=2018","name":"Protection function OF eTO chamber SYSTEM - ETO STERILIZER","isPartOf":{"@id":"https:\/\/zjbocon.com\/#website"},"primaryImageOfPage":{"@id":"https:\/\/zjbocon.com\/?p=2018#primaryimage"},"image":{"@id":"https:\/\/zjbocon.com\/?p=2018#primaryimage"},"thumbnailUrl":"https:\/\/zjbocon.com\/wp-content\/uploads\/2024\/10\/customer_5.webp","datePublished":"2024-10-28T03:23:57+00:00","dateModified":"2024-11-06T06:09:44+00:00","description":"ETO chamber System (The ETO sterilizer system )has six different levels of operation permissions. Personnel with different permissions","breadcrumb":{"@id":"https:\/\/zjbocon.com\/?p=2018#breadcrumb"},"inLanguage":"hu-HU","potentialAction":[{"@type":"ReadAction","target":["https:\/\/zjbocon.com\/?p=2018"]}]},{"@type":"ImageObject","inLanguage":"hu-HU","@id":"https:\/\/zjbocon.com\/?p=2018#primaryimage","url":"https:\/\/zjbocon.com\/wp-content\/uploads\/2024\/10\/customer_5.webp","contentUrl":"https:\/\/zjbocon.com\/wp-content\/uploads\/2024\/10\/customer_5.webp","width":300,"height":200},{"@type":"BreadcrumbList","@id":"https:\/\/zjbocon.com\/?p=2018#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/zjbocon.com\/"},{"@type":"ListItem","position":2,"name":"Protection function OF eTO chamber SYSTEM"}]},{"@type":"WebSite","@id":"https:\/\/zjbocon.com\/#website","url":"https:\/\/zjbocon.com\/","name":"ETO STERILIZER","description":"One-stop Solution Supplier of Ethylene Oxide Sterilization","publisher":{"@id":"https:\/\/zjbocon.com\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/zjbocon.com\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"hu-HU"},{"@type":"Organization","@id":"https:\/\/zjbocon.com\/#organization","name":"ETO STERILIZER","url":"https:\/\/zjbocon.com\/","logo":{"@type":"ImageObject","inLanguage":"hu-HU","@id":"https:\/\/zjbocon.com\/#\/schema\/logo\/image\/","url":"https:\/\/zjbocon.com\/wp-content\/uploads\/2024\/10\/logo-1.webp","contentUrl":"https:\/\/zjbocon.com\/wp-content\/uploads\/2024\/10\/logo-1.webp","width":180,"height":60,"caption":"ETO STERILIZER"},"image":{"@id":"https:\/\/zjbocon.com\/#\/schema\/logo\/image\/"},"sameAs":["https:\/\/www.facebook.com\/profile.php?id=100088482339878","https:\/\/x.com\/BoconAnd","https:\/\/www.linkedin.com\/in\/--06a221139\/"]},{"@type":"Person","@id":"https:\/\/zjbocon.com\/#\/schema\/person\/f12be028b8ae9843a4396dcc8012b425","name":"Bocon Technical Team","image":{"@type":"ImageObject","inLanguage":"hu-HU","@id":"https:\/\/secure.gravatar.com\/avatar\/d7a825658be227f26b237e519f8541e05aabc9ff27b8eec4544a233a48c53be0?s=96&d=identicon&r=g","url":"https:\/\/secure.gravatar.com\/avatar\/d7a825658be227f26b237e519f8541e05aabc9ff27b8eec4544a233a48c53be0?s=96&d=identicon&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/d7a825658be227f26b237e519f8541e05aabc9ff27b8eec4544a233a48c53be0?s=96&d=identicon&r=g","caption":"Bocon Technical Team"},"sameAs":["https:\/\/zjbocon.com\/","https:\/\/www.facebook.com\/profile.php?id=100088482339878","https:\/\/www.linkedin.com\/in\/\/hayley--968190269\/"],"url":"https:\/\/zjbocon.com\/?author=234312599"}]}},"jetpack_publicize_connections":[],"jetpack_featured_media_url":"https:\/\/zjbocon.com\/wp-content\/uploads\/2024\/10\/customer_5.webp","uagb_featured_image_src":{"full":["https:\/\/zjbocon.com\/wp-content\/uploads\/2024\/10\/customer_5.webp",300,200,false],"thumbnail":["https:\/\/zjbocon.com\/wp-content\/uploads\/2024\/10\/customer_5-150x150.webp",150,150,true],"medium":["https:\/\/zjbocon.com\/wp-content\/uploads\/2024\/10\/customer_5.webp",300,200,false],"medium_large":["https:\/\/zjbocon.com\/wp-content\/uploads\/2024\/10\/customer_5.webp",300,200,false],"large":["https:\/\/zjbocon.com\/wp-content\/uploads\/2024\/10\/customer_5.webp",300,200,false],"1536x1536":["https:\/\/zjbocon.com\/wp-content\/uploads\/2024\/10\/customer_5.webp",300,200,false],"2048x2048":["https:\/\/zjbocon.com\/wp-content\/uploads\/2024\/10\/customer_5.webp",300,200,false],"woocommerce_thumbnail":["https:\/\/zjbocon.com\/wp-content\/uploads\/2024\/10\/customer_5.webp",300,200,false],"woocommerce_single":["https:\/\/zjbocon.com\/wp-content\/uploads\/2024\/10\/customer_5.webp",300,200,false],"woocommerce_gallery_thumbnail":["https:\/\/zjbocon.com\/wp-content\/uploads\/2024\/10\/customer_5-100x100.webp",100,100,true]},"uagb_author_info":{"display_name":"Bocon Technical Team","author_link":"https:\/\/zjbocon.com\/?author=234312599"},"uagb_comment_info":23,"uagb_excerpt":"Protection mechanism and explanation OF ETO Sterilizer System 2. By default, the system will perform the leak detection test before [&hellip;]","jetpack_likes_enabled":true,"jetpack_sharing_enabled":true,"jetpack_shortlink":"https:\/\/wp.me\/pgZDV6-wy","jetpack-related-posts":[{"id":2492,"url":"https:\/\/zjbocon.com\/?p=2492","url_meta":{"origin":2018,"position":0},"title":"Understanding ETO Sterilizer Performance: Keys to Efficiency","author":"Bocon Technical Team","date":"2024-12-24","format":false,"excerpt":"3.4.1 eto sterilizer machine Temperature Setting Range The temperature setting range for the eto sterilizer is: 30 to 70\u00b0C","rel":"","context":"In &quot;Company News&quot;","block_context":{"text":"Company News","link":"https:\/\/zjbocon.com\/?cat=133125"},"img":{"alt_text":"","src":"https:\/\/i0.wp.com\/zjbocon.com\/wp-content\/uploads\/2025\/09\/eto-sterilizer-1.webp?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/zjbocon.com\/wp-content\/uploads\/2025\/09\/eto-sterilizer-1.webp?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/zjbocon.com\/wp-content\/uploads\/2025\/09\/eto-sterilizer-1.webp?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/zjbocon.com\/wp-content\/uploads\/2025\/09\/eto-sterilizer-1.webp?resize=700%2C400&ssl=1 2x, https:\/\/i0.wp.com\/zjbocon.com\/wp-content\/uploads\/2025\/09\/eto-sterilizer-1.webp?resize=1050%2C600&ssl=1 3x"},"classes":[]},{"id":9255,"url":"https:\/\/zjbocon.com\/?p=9255","url_meta":{"origin":2018,"position":1},"title":"Featured System: The Bocon ETO Sterilizer Series","author":"Bocon Technical Team","date":"2026-02-06","format":false,"excerpt":"PHASE 01 PHASE 02 PHASE 03 PHASE 04 PHASE 05 Industrial Grade ETO Sterilization Solutions Explore Bocon ETO Sterilizer Details ? Why Leading Manufacturers Integrate Bocon Systems: Looking to upgrade your sterilization capacity? Explore the Technical Specifications of the Bocon ETO Sterilizer Series ? Headline: From Logistics to Operational Readiness:\u2026","rel":"","context":"In &quot;ETO STERILIZER&quot;","block_context":{"text":"ETO STERILIZER","link":"https:\/\/zjbocon.com\/?cat=133124"},"img":{"alt_text":"","src":"https:\/\/i0.wp.com\/zjbocon.com\/wp-content\/uploads\/2026\/02\/Featured-System-The-Bocon-ETO-Sterilizer-Series-1.webp?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/zjbocon.com\/wp-content\/uploads\/2026\/02\/Featured-System-The-Bocon-ETO-Sterilizer-Series-1.webp?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/zjbocon.com\/wp-content\/uploads\/2026\/02\/Featured-System-The-Bocon-ETO-Sterilizer-Series-1.webp?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/zjbocon.com\/wp-content\/uploads\/2026\/02\/Featured-System-The-Bocon-ETO-Sterilizer-Series-1.webp?resize=700%2C400&ssl=1 2x, https:\/\/i0.wp.com\/zjbocon.com\/wp-content\/uploads\/2026\/02\/Featured-System-The-Bocon-ETO-Sterilizer-Series-1.webp?resize=1050%2C600&ssl=1 3x, https:\/\/i0.wp.com\/zjbocon.com\/wp-content\/uploads\/2026\/02\/Featured-System-The-Bocon-ETO-Sterilizer-Series-1.webp?resize=1400%2C800&ssl=1 4x"},"classes":[]},{"id":2064,"url":"https:\/\/zjbocon.com\/?p=2064","url_meta":{"origin":2018,"position":2},"title":"OQ IN ETO STERILIZATION MACHINE","author":"Bocon Technical Team","date":"2024-10-31","format":false,"excerpt":"In OQ, the performance of the relevant auxiliary system should be determined and the software system should be tested by simulating the fault conditions.","rel":"","context":"In &quot;ETO STERILIZER&quot;","block_context":{"text":"ETO STERILIZER","link":"https:\/\/zjbocon.com\/?cat=133124"},"img":{"alt_text":"","src":"https:\/\/i0.wp.com\/zjbocon.com\/wp-content\/uploads\/2025\/09\/Ethylene-Oxide-Sterilizer-Installation-Guide-1-scaled.webp?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/zjbocon.com\/wp-content\/uploads\/2025\/09\/Ethylene-Oxide-Sterilizer-Installation-Guide-1-scaled.webp?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/zjbocon.com\/wp-content\/uploads\/2025\/09\/Ethylene-Oxide-Sterilizer-Installation-Guide-1-scaled.webp?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/zjbocon.com\/wp-content\/uploads\/2025\/09\/Ethylene-Oxide-Sterilizer-Installation-Guide-1-scaled.webp?resize=700%2C400&ssl=1 2x, https:\/\/i0.wp.com\/zjbocon.com\/wp-content\/uploads\/2025\/09\/Ethylene-Oxide-Sterilizer-Installation-Guide-1-scaled.webp?resize=1050%2C600&ssl=1 3x, https:\/\/i0.wp.com\/zjbocon.com\/wp-content\/uploads\/2025\/09\/Ethylene-Oxide-Sterilizer-Installation-Guide-1-scaled.webp?resize=1400%2C800&ssl=1 4x"},"classes":[]},{"id":2094,"url":"https:\/\/zjbocon.com\/?p=2094","url_meta":{"origin":2018,"position":3},"title":"ETO Sterilizer Manufacturer-HZBOCON","author":"Bocon Technical Team","date":"2024-11-04","format":false,"excerpt":"Hangzhou Bocon Mechanical and Electrical Equipment Co., Ltd., commonly referred to as HZBOCON, stands out as a dedicated Ethylene Oxide (EO\/ETO) sterilizer manufacturer. Established in 2006, HZBOCON has committed itself to the design, development, and manufacturing of EO sterilization equipment, catering to a wide array of industries that require effective\u2026","rel":"","context":"In &quot;ETO STERILIZER&quot;","block_context":{"text":"ETO STERILIZER","link":"https:\/\/zjbocon.com\/?cat=133124"},"img":{"alt_text":"","src":"https:\/\/i0.wp.com\/zjbocon.com\/wp-content\/uploads\/2024\/11\/eto-sterilizer-hzbocon-4.png?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/zjbocon.com\/wp-content\/uploads\/2024\/11\/eto-sterilizer-hzbocon-4.png?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/zjbocon.com\/wp-content\/uploads\/2024\/11\/eto-sterilizer-hzbocon-4.png?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/zjbocon.com\/wp-content\/uploads\/2024\/11\/eto-sterilizer-hzbocon-4.png?resize=700%2C400&ssl=1 2x, https:\/\/i0.wp.com\/zjbocon.com\/wp-content\/uploads\/2024\/11\/eto-sterilizer-hzbocon-4.png?resize=1050%2C600&ssl=1 3x"},"classes":[]},{"id":2534,"url":"https:\/\/zjbocon.com\/?p=2534","url_meta":{"origin":2018,"position":4},"title":"How to Loading Sterilization product when using eto gas sterilizer","author":"Bocon Technical Team","date":"2024-12-27","format":false,"excerpt":"Sterilizer-chamber-conveyor Sterilizer-chamber-conveyor Sterilizer-chamber-conveyor 8.4.1 Closing the eto gas sterilizer Discharge Door For double-door eto gas sterilizer, before loading sterilization goods, follow the closing procedure for the discharge door, and inflate the sealing gasket of the discharge door until the pressure reaches above 0.45 MPa to ensure a proper seal. Manually\u2026","rel":"","context":"In &quot;Company News&quot;","block_context":{"text":"Company News","link":"https:\/\/zjbocon.com\/?cat=133125"},"img":{"alt_text":"","src":"https:\/\/i0.wp.com\/zjbocon.com\/wp-content\/uploads\/2025\/09\/Automatic-Sterilizer-Chamber-Conveyor-1.webp?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/zjbocon.com\/wp-content\/uploads\/2025\/09\/Automatic-Sterilizer-Chamber-Conveyor-1.webp?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/zjbocon.com\/wp-content\/uploads\/2025\/09\/Automatic-Sterilizer-Chamber-Conveyor-1.webp?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/zjbocon.com\/wp-content\/uploads\/2025\/09\/Automatic-Sterilizer-Chamber-Conveyor-1.webp?resize=700%2C400&ssl=1 2x"},"classes":[]},{"id":2117,"url":"https:\/\/zjbocon.com\/?p=2117","url_meta":{"origin":2018,"position":5},"title":"Industry Eto Sterilizer Installation Verification","author":"Bocon Technical Team","date":"2024-11-06","format":false,"excerpt":"Industry Eto Sterilizer Installation Verification The installation of Industry Eto Sterilizer and all associated services should comply with the requirements of the construction and engineering drawings. It is recommended to verify the components of the Industry Eto Sterilizer to ensure the installation meets applicable standards and requirements. These equipment components\u2026","rel":"","context":"In &quot;ETO STERILIZER&quot;","block_context":{"text":"ETO STERILIZER","link":"https:\/\/zjbocon.com\/?cat=133124"},"img":{"alt_text":"","src":"https:\/\/i0.wp.com\/zjbocon.com\/wp-content\/uploads\/2024\/10\/sterilizer-station-design-2.webp?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/zjbocon.com\/wp-content\/uploads\/2024\/10\/sterilizer-station-design-2.webp?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/zjbocon.com\/wp-content\/uploads\/2024\/10\/sterilizer-station-design-2.webp?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/zjbocon.com\/wp-content\/uploads\/2024\/10\/sterilizer-station-design-2.webp?resize=700%2C400&ssl=1 2x"},"classes":[]}],"_links":{"self":[{"href":"https:\/\/zjbocon.com\/index.php?rest_route=\/wp\/v2\/posts\/2018","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/zjbocon.com\/index.php?rest_route=\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/zjbocon.com\/index.php?rest_route=\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/zjbocon.com\/index.php?rest_route=\/wp\/v2\/users\/234312599"}],"replies":[{"embeddable":true,"href":"https:\/\/zjbocon.com\/index.php?rest_route=%2Fwp%2Fv2%2Fcomments&post=2018"}],"version-history":[{"count":12,"href":"https:\/\/zjbocon.com\/index.php?rest_route=\/wp\/v2\/posts\/2018\/revisions"}],"predecessor-version":[{"id":2030,"href":"https:\/\/zjbocon.com\/index.php?rest_route=\/wp\/v2\/posts\/2018\/revisions\/2030"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/zjbocon.com\/index.php?rest_route=\/wp\/v2\/media\/1889"}],"wp:attachment":[{"href":"https:\/\/zjbocon.com\/index.php?rest_route=%2Fwp%2Fv2%2Fmedia&parent=2018"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/zjbocon.com\/index.php?rest_route=%2Fwp%2Fv2%2Fcategories&post=2018"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/zjbocon.com\/index.php?rest_route=%2Fwp%2Fv2%2Ftags&post=2018"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}