{"id":7286,"date":"2025-07-29T12:02:12","date_gmt":"2025-07-29T04:02:12","guid":{"rendered":"https:\/\/zjbocon.com\/?p=7286"},"modified":"2025-10-01T19:30:30","modified_gmt":"2025-10-01T11:30:30","slug":"eto-sterilization-re-qualification","status":"publish","type":"post","link":"https:\/\/zjbocon.com\/?p=7286","title":{"rendered":"ETO Sterilization Re-qualification"},"content":{"rendered":"\n<h2 class=\"wp-block-heading\" id=\"h-eto-sterilization-re-qualification-requirements\">Persyaratan Rekualifikasi Sterilisasi ETO<\/h2>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"h-1-re-qualification-frequency\">1. Frekuensi Kualifikasi Ulang<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">\u2022&nbsp;<strong>Persyaratan minimum tahunan<\/strong><br>\u2022 At least once per year, verification data, subsequent re-validation data, and routine processing data must be reviewed<br>\u2022 The scope of re-qualification must be determined and documented<br>\u2022 The review procedure shall be documented<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"h-2-is-re-qualification-needed-if-no-product-changes-occur\">2. Apakah Perlu Kualifikasi Ulang Jika Tidak Terjadi Perubahan Produk?<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">\u2022&nbsp;<strong>Ya, kualifikasi ulang masih diperlukan<\/strong><\/p>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"h-3-re-qualification-items\">3. Butir Kualifikasi Ulang<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">\u2022&nbsp;<strong>Berdasarkan prasyarat tertentu, opsi berikut tersedia<\/strong>:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Kualifikasi ulang penuh<\/li>\n\n\n\n<li>Tidak perlu validasi ulang fisik atau mikroba<\/li>\n\n\n\n<li>Validasi kinerja mikroba skala kecil<\/li>\n<\/ul>\n\n\n\n<h2 class=\"wp-block-heading\"><strong>Prasyarat untuk Re-kualifikasi<\/strong><\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">a) The following must be reviewed\/tested:<br>b) Apakah ada<strong>perubahan signifikan<\/strong>&nbsp;mempengaruhi sterilitas produk telah terjadi pada:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Desain produk<\/li>\n\n\n\n<li>Manufacturing\/packaging materials<\/li>\n\n\n\n<li>PCD (Perangkat Tantangan Proses)<\/li>\n\n\n\n<li>Pemasok<\/li>\n\n\n\n<li>Manufacturing areas\/facilities<\/li>\n\n\n\n<li>Konfigurasi beban atau proses manufaktur<br>C)<strong>Analisis tren beban biologis<\/strong>&nbsp;produk;<br>d) Apakah<strong>studi distribusi suhu<\/strong>&nbsp;dan pengoperasian alat sterilisasi menunjukkan perubahan signifikan sejak kualifikasi terakhir;<br>e) Apakah<strong>pemeriksaan distribusi suhu dan resirkulasi<\/strong>&nbsp;pada ruang prakondisi atau zona aerasi menunjukkan perubahan signifikan sejak kualifikasi terakhir;<br>f) Apakah Sterilisasi ETO<strong> sejarah proses<\/strong>&nbsp;sejak validasi terakhir menunjukkan reproduktifitas;<br>g) Apakah<strong>pengendalian perubahan dan catatan pemeliharaan preventif<\/strong>&nbsp;pastikan tidak ada modifikasi peralatan yang mempengaruhi proses;<br>h) Apakah<strong>tidak ada perubahan pada proses Sterilisasi ETO<\/strong>&nbsp;telah terjadi dampak yang mempengaruhi kemandulan;<br>i) Jika<strong>Spesifikasi proses Sterilisasi ETO berubah<\/strong>, kualifikasi ulang harus mencakup verifikasi<strong>Batas residu EO<\/strong>&nbsp;kepatuhan terhadap persyaratan peraturan.<\/li>\n<\/ul>\n\n\n\n<h3 class=\"wp-block-heading\"><strong>Standar Peraturan<\/strong><\/h3>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong>ISO 11135:2014<\/strong>&nbsp;<em>(Bagian 9.2: Kriteria rekualifikasi)<\/em><\/li>\n\n\n\n<li><strong>FDA 21 CFR 211.113<\/strong>&nbsp;<em>(Kontrol proses sterilisasi)<\/em><\/li>\n\n\n\n<li><strong>Lampiran GMP UE 1:2022<\/strong>&nbsp;<em>(Bagian 8.5: Persyaratan validasi ulang)<\/em><\/li>\n<\/ul>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"h-eto-sterilization-re-qualification-requirements-0\"><strong>Persyaratan Rekualifikasi Sterilisasi ETO<\/strong><\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Kualifikasi ulang harus<strong>termasuk tinjauan kinerja ruang dan perubahan teknis tahunan<\/strong>&nbsp;to ensure the original IQ\/OQ results remain valid. The review must cover:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong>Preconditioning zone temperature\/humidity profiles<\/strong>&nbsp;(jika ada);<\/li>\n\n\n\n<li><strong>Profil kelembaban ruang kosong yang sebenarnya<\/strong>;<\/li>\n\n\n\n<li><strong>Suhu zona aerasi<\/strong>&nbsp;(jika ada);<\/li>\n\n\n\n<li><strong>Selain itu, meskipun spesifikasi proses terpenuhi<\/strong>, inspections must be triggered by:\n<ul class=\"wp-block-list\">\n<li>Tren buruk dalam kinerja peralatan,<\/li>\n\n\n\n<li>Kegagalan sterilitas;<\/li>\n\n\n\n<li>Untuk menentukan apakah validasi ulang diperlukan.<\/li>\n<\/ul>\n<\/li>\n\n\n\n<li><strong>Pakar sterilisasi<\/strong>&nbsp;harus menentukan ruang lingkup yang diperlukan<strong>validasi ulang fisik dan mikroba<\/strong>&nbsp;berdasarkan hasil tinjauan.<\/li>\n<\/ul>\n\n\n\n<h2 class=\"wp-block-heading\"><strong>Pertimbangan Penting untuk Re-kualifikasi Sterilisasi<\/strong><\/h2>\n\n\n\n<h3 class=\"wp-block-heading\"><strong>1. Menangani Perubahan Signifikan<\/strong><\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">\u2022 If&nbsp;<strong>perubahan besar<\/strong>&nbsp;are identified during re-qualification, re-execution of IQ\/OQ\/PQ may be required:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong>IQ (Kualifikasi Instalasi)<\/strong>: Verify modified equipment\/software installation.<\/li>\n\n\n\n<li><strong>OQ (Kualifikasi Operasional)<\/strong>: Menguji ulang parameter fungsional yang terkena dampak.<\/li>\n\n\n\n<li><strong>PQ (Kualifikasi Kinerja)<\/strong>: Validasi ulang kemanjuran sterilisasi dalam kondisi baru.<\/li>\n<\/ul>\n\n\n\n<h3 class=\"wp-block-heading\"><strong>2. Persyaratan Tambahan untuk Pelepasan Parametrik<\/strong><\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Untuk fasilitas yang menggunakan<strong>pelepasan parametrik<\/strong>&nbsp;(mengandalkan data proses daripada pengujian BI):<br>A)<strong>Frekuensi validasi ulang<\/strong>: Harus dilakukan<strong>setidaknya setiap tahun<\/strong>;<br>B)<strong>Cakupan validasi ulang<\/strong>: Harus disertakan<strong>studi mikrobiologi<\/strong>&nbsp;untuk mengonfirmasi:<\/p>\n\n\n\n<h2 class=\"wp-block-heading\"><strong>Situations Requiring Full Requalification (IQ\/OQ\/PQ):<\/strong><\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">A)<strong>Perawatan utama alat sterilisasi<\/strong>;<br>B)<strong>Perubahan struktural, lokasi, atau lingkungan<\/strong>;<br>C)<strong>Kegagalan sterilitas yang tidak dapat dijelaskan<\/strong>;<br>D)<strong>Changes in EO supply\/delivery, diluent, or chamber load configuration<\/strong>.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\"><strong>Pengecualian dari Rekualifikasi Fisik atau Mikroba<\/strong><\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Ketika kondisi berikut terpenuhi:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong>Tidak ada perubahan<\/strong>&nbsp;in product, packaging, equipment\/services, or processes;<\/li>\n\n\n\n<li><strong>Tinjauan kinerja dan teknik ruangan<\/strong>&nbsp;memenuhi syarat;<\/li>\n\n\n\n<li><strong>Proses sterilisasi rutin<\/strong>&nbsp;telah beroperasi dengan andal selama periode tersebut;<br>?<strong>Penilaian profesional<\/strong>&nbsp;dapat menentukan apakah kualifikasi ulang secara fisik atau mikroba diperlukan<strong>tidak diperlukan<\/strong>&nbsp;sampai ulasan berikutnya.<\/li>\n<\/ul>\n\n\n\n<h2 class=\"wp-block-heading\"><strong>Kualifikasi Kinerja Mikroba Skala Terbatas<\/strong><\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">\u2022&nbsp;<strong>Mungkin diperlukan dalam kasus tertentu<\/strong>, seperti:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Memverifikasi kelanjutan kesesuaian BI dengan produk bioburden;<\/li>\n\n\n\n<li>Memberikan bukti bahwa tidak<strong>perubahan yang tidak disengaja<\/strong>&nbsp;terjadi sejak studi kualifikasi (ulang) sebelumnya setelah selang waktu yang ditentukan.<br>\u2022&nbsp;<strong>Persyaratan umum (minimal)<\/strong>:<\/li>\n\n\n\n<li>Satu<strong>lari siklus pendek atau setengah siklus<\/strong>;<\/li>\n\n\n\n<li>Termasuk<strong>pengukuran suhu dan kelembaban<\/strong>&nbsp;dari barang-barang yang disterilkan.<\/li>\n<\/ul>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"h-if-you-want-to-know-more\">Jika Anda ingin tahu lebih banyak<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Telepon:<a href=\"https:\/\/wa.me\/8619975258603\">+8619975258603<\/a><\/p>\n\n\n\n<p class=\"wp-block-paragraph\">E-mail:<a href=\"mailto:hayley@hzbocon.com\">hayley@hzbocon.com<\/a><\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Situs Lokal: Kamar 1202, Caitong Zhongxin, Distrik Xiasha, Kota Hangzhou, Provinsi Zhejiang, Tiongkok<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Situs web:<a href=\"https:\/\/www.hzbocon.com\/\">hzbocon.com<\/a><a href=\"https:\/\/zjbocon.com\/\">zjbocon.com<\/a><\/p>\n\n\n\n<div class=\"wp-block-uagb-image uagb-block-9d7632fc wp-block-uagb-image--layout-default wp-block-uagb-image--effect-static wp-block-uagb-image--align-none\"><figure class=\"wp-block-uagb-image__figure\"><img loading=\"lazy\" decoding=\"async\" src=\"https:\/\/zjbocon.com\/wp-content\/uploads\/2025\/09\/eto-sterilizer-9-1024x1024.webp\" alt=\"\" class=\"uag-image-8487\" width=\"1024\" height=\"1024\" title=\"eto-sterilizer-9\" role=\"img\" \><\/figure><\/div>\n\n\n\n<p class=\"wp-block-paragraph\"><\/p>\n","protected":false},"excerpt":{"rendered":"<p>ETO Sterilization Re-qualification Requirements 1. Re-qualification Frequency \u2022&nbsp;Minimum annual requirement\u2022 At least once per year, verification data, subsequent re-validation data, [&hellip;]<\/p>\n","protected":false},"author":234312599,"featured_media":8487,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_uag_custom_page_level_css":"","site-sidebar-layout":"default","site-content-layout":"","ast-site-content-layout":"default","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","ast-disable-related-posts":"","theme-transparent-header-meta":"","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"set","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"_jetpack_newsletter_access":"","_jetpack_dont_email_post_to_subs":false,"_jetpack_newsletter_tier_id":0,"_jetpack_memberships_contains_paywalled_content":false,"_jetpack_feature_clip_id":0,"_jetpack_memberships_contains_paid_content":false,"footnotes":"","jetpack_publicize_message":"","jetpack_publicize_feature_enabled":true,"jetpack_social_post_already_shared":false,"jetpack_social_options":{"image_generator_settings":{"template":"highway","default_image_id":0,"enabled":false},"version":2},"jetpack_post_was_ever_published":false},"categories":[133125,133124],"tags":[],"class_list":["post-7286","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-company-news","category-eto-sterilizer"],"yoast_head":"<!-- This site is optimized with the Yoast SEO Premium plugin v27.2 (Yoast SEO v28.0) - https:\/\/yoast.com\/product\/yoast-seo-premium-wordpress\/ -->\n<title>Kualifikasi Ulang Sterilisasi ETO - ETO STERILIZER<\/title>\n<meta name=\"description\" content=\"\u2022\u00a0Minimum annual requirement\u2022 At least once per year, verification data, subsequent re-validation and\" \>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \>\n<link rel=\"canonical\" href=\"https:\/\/zjbocon.com\/?p=7286\" \>\n<meta property=\"og:locale\" content=\"id_ID\" \>\n<meta property=\"og:type\" content=\"article\" \>\n<meta property=\"og:title\" content=\"ETO Sterilization Re-qualification\" \>\n<meta property=\"og:description\" content=\"\u2022\u00a0Minimum annual requirement\u2022 At least once per year, verification data, subsequent re-validation and\" \>\n<meta property=\"og:url\" content=\"https:\/\/zjbocon.com\/?p=7286\" \>\n<meta property=\"og:site_name\" content=\"ETO STERILIZER\" \>\n<meta property=\"article:publisher\" content=\"https:\/\/www.facebook.com\/profile.php?id=100088482339878\" \>\n<meta property=\"article:author\" content=\"https:\/\/www.facebook.com\/profile.php?id=100088482339878\" \>\n<meta property=\"article:published_time\" content=\"2025-07-29T04:02:12+00:00\" \>\n<meta property=\"article:modified_time\" content=\"2025-10-01T11:30:30+00:00\" \>\n<meta property=\"og:image\" content=\"https:\/\/zjbocon.com\/wp-content\/uploads\/2025\/09\/eto-sterilizer-9.webp\" \>\n\t<meta property=\"og:image:width\" content=\"1200\" \>\n\t<meta property=\"og:image:height\" content=\"1200\" \>\n\t<meta property=\"og:image:type\" content=\"image\/webp\" \>\n<meta name=\"author\" content=\"Bocon Technical Team\" \>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \>\n<meta name=\"twitter:creator\" content=\"@BoconAnd\" \>\n<meta name=\"twitter:site\" content=\"@BoconAnd\" \>\n<meta name=\"twitter:label1\" content=\"Written by\" \>\n\t<meta name=\"twitter:data1\" content=\"Bocon Technical Team\" \>\n\t<meta name=\"twitter:label2\" content=\"Est. reading time\" \>\n\t<meta name=\"twitter:data2\" content=\"3 minutes\" \>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\\\/\\\/zjbocon.com\\\/?p=7286#article\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/zjbocon.com\\\/?p=7286\"},\"author\":{\"name\":\"Bocon Technical Team\",\"@id\":\"https:\\\/\\\/zjbocon.com\\\/#\\\/schema\\\/person\\\/f12be028b8ae9843a4396dcc8012b425\"},\"headline\":\"ETO Sterilization Re-qualification\",\"datePublished\":\"2025-07-29T04:02:12+00:00\",\"dateModified\":\"2025-10-01T11:30:30+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/zjbocon.com\\\/?p=7286\"},\"wordCount\":634,\"commentCount\":0,\"publisher\":{\"@id\":\"https:\\\/\\\/zjbocon.com\\\/#organization\"},\"image\":{\"@id\":\"https:\\\/\\\/zjbocon.com\\\/?p=7286#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/zjbocon.com\\\/wp-content\\\/uploads\\\/2025\\\/09\\\/eto-sterilizer-9.webp\",\"articleSection\":[\"Company News\",\"ETO STERILIZER\"],\"inLanguage\":\"id-ID\",\"potentialAction\":[{\"@type\":\"CommentAction\",\"name\":\"Comment\",\"target\":[\"https:\\\/\\\/zjbocon.com\\\/?p=7286#respond\"]}]},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/zjbocon.com\\\/?p=7286\",\"url\":\"https:\\\/\\\/zjbocon.com\\\/?p=7286\",\"name\":\"ETO Sterilization Re-qualification - ETO STERILIZER\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/zjbocon.com\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/zjbocon.com\\\/?p=7286#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/zjbocon.com\\\/?p=7286#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/zjbocon.com\\\/wp-content\\\/uploads\\\/2025\\\/09\\\/eto-sterilizer-9.webp\",\"datePublished\":\"2025-07-29T04:02:12+00:00\",\"dateModified\":\"2025-10-01T11:30:30+00:00\",\"description\":\"\u2022\u00a0Minimum annual requirement\u2022 At least once per year, verification data, subsequent re-validation data, and\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/zjbocon.com\\\/?p=7286#breadcrumb\"},\"inLanguage\":\"id-ID\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/zjbocon.com\\\/?p=7286\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"id-ID\",\"@id\":\"https:\\\/\\\/zjbocon.com\\\/?p=7286#primaryimage\",\"url\":\"https:\\\/\\\/zjbocon.com\\\/wp-content\\\/uploads\\\/2025\\\/09\\\/eto-sterilizer-9.webp\",\"contentUrl\":\"https:\\\/\\\/zjbocon.com\\\/wp-content\\\/uploads\\\/2025\\\/09\\\/eto-sterilizer-9.webp\",\"width\":1200,\"height\":1200,\"caption\":\"ETO STERILIZER-HZBOCON\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/zjbocon.com\\\/?p=7286#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/zjbocon.com\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"ETO Sterilization Re-qualification\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/zjbocon.com\\\/#website\",\"url\":\"https:\\\/\\\/zjbocon.com\\\/\",\"name\":\"ETO STERILIZER\",\"description\":\"One-stop Solution Supplier of Ethylene Oxide Sterilization\",\"publisher\":{\"@id\":\"https:\\\/\\\/zjbocon.com\\\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/zjbocon.com\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"id-ID\"},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/zjbocon.com\\\/#organization\",\"name\":\"ETO STERILIZER\",\"url\":\"https:\\\/\\\/zjbocon.com\\\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"id-ID\",\"@id\":\"https:\\\/\\\/zjbocon.com\\\/#\\\/schema\\\/logo\\\/image\\\/\",\"url\":\"https:\\\/\\\/zjbocon.com\\\/wp-content\\\/uploads\\\/2024\\\/10\\\/logo-1.webp\",\"contentUrl\":\"https:\\\/\\\/zjbocon.com\\\/wp-content\\\/uploads\\\/2024\\\/10\\\/logo-1.webp\",\"width\":180,\"height\":60,\"caption\":\"ETO STERILIZER\"},\"image\":{\"@id\":\"https:\\\/\\\/zjbocon.com\\\/#\\\/schema\\\/logo\\\/image\\\/\"},\"sameAs\":[\"https:\\\/\\\/www.facebook.com\\\/profile.php?id=100088482339878\",\"https:\\\/\\\/x.com\\\/BoconAnd\",\"https:\\\/\\\/www.linkedin.com\\\/in\\\/--06a221139\\\/\"]},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/zjbocon.com\\\/#\\\/schema\\\/person\\\/f12be028b8ae9843a4396dcc8012b425\",\"name\":\"Bocon Technical Team\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"id-ID\",\"@id\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/d7a825658be227f26b237e519f8541e05aabc9ff27b8eec4544a233a48c53be0?s=96&d=identicon&r=g\",\"url\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/d7a825658be227f26b237e519f8541e05aabc9ff27b8eec4544a233a48c53be0?s=96&d=identicon&r=g\",\"contentUrl\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/d7a825658be227f26b237e519f8541e05aabc9ff27b8eec4544a233a48c53be0?s=96&d=identicon&r=g\",\"caption\":\"Bocon Technical Team\"},\"sameAs\":[\"https:\\\/\\\/zjbocon.com\\\/\",\"https:\\\/\\\/www.facebook.com\\\/profile.php?id=100088482339878\",\"https:\\\/\\\/www.linkedin.com\\\/in\\\/\\\/hayley--968190269\\\/\"],\"url\":\"https:\\\/\\\/zjbocon.com\\\/?author=234312599\"}]}<\/script>\n<!-- \/ Yoast SEO Premium plugin. -->","yoast_head_json":{"title":"ETO Sterilization Re-qualification - ETO STERILIZER","description":"\u2022\u00a0Minimum annual requirement\u2022 At least once per year, verification data, subsequent re-validation data, and","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/zjbocon.com\/?p=7286","og_locale":"id_ID","og_type":"article","og_title":"ETO Sterilization Re-qualification","og_description":"\u2022\u00a0Minimum annual requirement\u2022 At least once per year, verification data, subsequent re-validation data, and","og_url":"https:\/\/zjbocon.com\/?p=7286","og_site_name":"ETO STERILIZER","article_publisher":"https:\/\/www.facebook.com\/profile.php?id=100088482339878","article_author":"https:\/\/www.facebook.com\/profile.php?id=100088482339878","article_published_time":"2025-07-29T04:02:12+00:00","article_modified_time":"2025-10-01T11:30:30+00:00","og_image":[{"width":1200,"height":1200,"url":"https:\/\/zjbocon.com\/wp-content\/uploads\/2025\/09\/eto-sterilizer-9.webp","type":"image\/webp"}],"author":"Bocon Technical Team","twitter_card":"summary_large_image","twitter_creator":"@BoconAnd","twitter_site":"@BoconAnd","twitter_misc":{"Written by":"Bocon Technical Team","Est. reading time":"3 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/zjbocon.com\/?p=7286#article","isPartOf":{"@id":"https:\/\/zjbocon.com\/?p=7286"},"author":{"name":"Bocon Technical Team","@id":"https:\/\/zjbocon.com\/#\/schema\/person\/f12be028b8ae9843a4396dcc8012b425"},"headline":"ETO Sterilization Re-qualification","datePublished":"2025-07-29T04:02:12+00:00","dateModified":"2025-10-01T11:30:30+00:00","mainEntityOfPage":{"@id":"https:\/\/zjbocon.com\/?p=7286"},"wordCount":634,"commentCount":0,"publisher":{"@id":"https:\/\/zjbocon.com\/#organization"},"image":{"@id":"https:\/\/zjbocon.com\/?p=7286#primaryimage"},"thumbnailUrl":"https:\/\/zjbocon.com\/wp-content\/uploads\/2025\/09\/eto-sterilizer-9.webp","articleSection":["Company News","ETO STERILIZER"],"inLanguage":"id-ID","potentialAction":[{"@type":"CommentAction","name":"Comment","target":["https:\/\/zjbocon.com\/?p=7286#respond"]}]},{"@type":"WebPage","@id":"https:\/\/zjbocon.com\/?p=7286","url":"https:\/\/zjbocon.com\/?p=7286","name":"ETO Sterilization Re-qualification - ETO STERILIZER","isPartOf":{"@id":"https:\/\/zjbocon.com\/#website"},"primaryImageOfPage":{"@id":"https:\/\/zjbocon.com\/?p=7286#primaryimage"},"image":{"@id":"https:\/\/zjbocon.com\/?p=7286#primaryimage"},"thumbnailUrl":"https:\/\/zjbocon.com\/wp-content\/uploads\/2025\/09\/eto-sterilizer-9.webp","datePublished":"2025-07-29T04:02:12+00:00","dateModified":"2025-10-01T11:30:30+00:00","description":"\u2022\u00a0Minimum annual requirement\u2022 At least once per year, verification data, subsequent re-validation data, and","breadcrumb":{"@id":"https:\/\/zjbocon.com\/?p=7286#breadcrumb"},"inLanguage":"id-ID","potentialAction":[{"@type":"ReadAction","target":["https:\/\/zjbocon.com\/?p=7286"]}]},{"@type":"ImageObject","inLanguage":"id-ID","@id":"https:\/\/zjbocon.com\/?p=7286#primaryimage","url":"https:\/\/zjbocon.com\/wp-content\/uploads\/2025\/09\/eto-sterilizer-9.webp","contentUrl":"https:\/\/zjbocon.com\/wp-content\/uploads\/2025\/09\/eto-sterilizer-9.webp","width":1200,"height":1200,"caption":"ETO STERILIZER-HZBOCON"},{"@type":"BreadcrumbList","@id":"https:\/\/zjbocon.com\/?p=7286#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/zjbocon.com\/"},{"@type":"ListItem","position":2,"name":"ETO Sterilization Re-qualification"}]},{"@type":"WebSite","@id":"https:\/\/zjbocon.com\/#website","url":"https:\/\/zjbocon.com\/","name":"ETO STERILIZER","description":"One-stop Solution Supplier of Ethylene Oxide Sterilization","publisher":{"@id":"https:\/\/zjbocon.com\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/zjbocon.com\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"id-ID"},{"@type":"Organization","@id":"https:\/\/zjbocon.com\/#organization","name":"ETO STERILIZER","url":"https:\/\/zjbocon.com\/","logo":{"@type":"ImageObject","inLanguage":"id-ID","@id":"https:\/\/zjbocon.com\/#\/schema\/logo\/image\/","url":"https:\/\/zjbocon.com\/wp-content\/uploads\/2024\/10\/logo-1.webp","contentUrl":"https:\/\/zjbocon.com\/wp-content\/uploads\/2024\/10\/logo-1.webp","width":180,"height":60,"caption":"ETO STERILIZER"},"image":{"@id":"https:\/\/zjbocon.com\/#\/schema\/logo\/image\/"},"sameAs":["https:\/\/www.facebook.com\/profile.php?id=100088482339878","https:\/\/x.com\/BoconAnd","https:\/\/www.linkedin.com\/in\/--06a221139\/"]},{"@type":"Person","@id":"https:\/\/zjbocon.com\/#\/schema\/person\/f12be028b8ae9843a4396dcc8012b425","name":"Bocon Technical Team","image":{"@type":"ImageObject","inLanguage":"id-ID","@id":"https:\/\/secure.gravatar.com\/avatar\/d7a825658be227f26b237e519f8541e05aabc9ff27b8eec4544a233a48c53be0?s=96&d=identicon&r=g","url":"https:\/\/secure.gravatar.com\/avatar\/d7a825658be227f26b237e519f8541e05aabc9ff27b8eec4544a233a48c53be0?s=96&d=identicon&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/d7a825658be227f26b237e519f8541e05aabc9ff27b8eec4544a233a48c53be0?s=96&d=identicon&r=g","caption":"Bocon Technical Team"},"sameAs":["https:\/\/zjbocon.com\/","https:\/\/www.facebook.com\/profile.php?id=100088482339878","https:\/\/www.linkedin.com\/in\/\/hayley--968190269\/"],"url":"https:\/\/zjbocon.com\/?author=234312599"}]}},"jetpack_publicize_connections":[],"jetpack_featured_media_url":"https:\/\/zjbocon.com\/wp-content\/uploads\/2025\/09\/eto-sterilizer-9.webp","uagb_featured_image_src":{"full":["https:\/\/zjbocon.com\/wp-content\/uploads\/2025\/09\/eto-sterilizer-9.webp",1200,1200,false],"thumbnail":["https:\/\/zjbocon.com\/wp-content\/uploads\/2025\/09\/eto-sterilizer-9-150x150.webp",150,150,true],"medium":["https:\/\/zjbocon.com\/wp-content\/uploads\/2025\/09\/eto-sterilizer-9-300x300.webp",300,300,true],"medium_large":["https:\/\/zjbocon.com\/wp-content\/uploads\/2025\/09\/eto-sterilizer-9-768x768.webp",768,768,true],"large":["https:\/\/zjbocon.com\/wp-content\/uploads\/2025\/09\/eto-sterilizer-9-1024x1024.webp",1024,1024,true],"1536x1536":["https:\/\/zjbocon.com\/wp-content\/uploads\/2025\/09\/eto-sterilizer-9.webp",1200,1200,false],"2048x2048":["https:\/\/zjbocon.com\/wp-content\/uploads\/2025\/09\/eto-sterilizer-9.webp",1200,1200,false],"woocommerce_thumbnail":["https:\/\/zjbocon.com\/wp-content\/uploads\/2025\/09\/eto-sterilizer-9-600x600.webp",600,600,true],"woocommerce_single":["https:\/\/zjbocon.com\/wp-content\/uploads\/2025\/09\/eto-sterilizer-9-600x600.webp",600,600,true],"woocommerce_gallery_thumbnail":["https:\/\/zjbocon.com\/wp-content\/uploads\/2025\/09\/eto-sterilizer-9-100x100.webp",100,100,true]},"uagb_author_info":{"display_name":"Bocon Technical Team","author_link":"https:\/\/zjbocon.com\/?author=234312599"},"uagb_comment_info":25,"uagb_excerpt":"ETO Sterilization Re-qualification Requirements 1. Re-qualification Frequency \u2022&nbsp;Minimum annual requirement\u2022 At least once per year, verification data, subsequent re-validation data, [&hellip;]","jetpack_likes_enabled":true,"jetpack_sharing_enabled":true,"jetpack_shortlink":"https:\/\/wp.me\/pgZDV6-1Tw","jetpack-related-posts":[{"id":7268,"url":"https:\/\/zjbocon.com\/?p=7268","url_meta":{"origin":7286,"position":0},"title":"Performance Qualification (PQ)- mpq in eto sterilization","author":"Bocon Technical Team","date":"2025-07-29","format":false,"excerpt":"Methods 1. Bioburden Method: Lethality Confirmation ? Direct Count\/Enumeration Method ? Fraction-Negative Method 2. Overkill Method: Demonstrating ?12-Log Reduction ? Half-Cycle Method ? Cycle Development Method Key Terms Bioburden 12-log reduction D-value Methods Overview 1. Half-Cycle Method (Basic Principle - Run Count) Theoretical initial bioburden: 10? Test Criteria: 1 run\u2026","rel":"","context":"In &quot;Company News&quot;","block_context":{"text":"Company News","link":"https:\/\/zjbocon.com\/?cat=133125"},"img":{"alt_text":"","src":"https:\/\/i0.wp.com\/zjbocon.com\/wp-content\/uploads\/2025\/09\/ethylene-oxide-sterilization-57-scaled.webp?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/zjbocon.com\/wp-content\/uploads\/2025\/09\/ethylene-oxide-sterilization-57-scaled.webp?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/zjbocon.com\/wp-content\/uploads\/2025\/09\/ethylene-oxide-sterilization-57-scaled.webp?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/zjbocon.com\/wp-content\/uploads\/2025\/09\/ethylene-oxide-sterilization-57-scaled.webp?resize=700%2C400&ssl=1 2x, https:\/\/i0.wp.com\/zjbocon.com\/wp-content\/uploads\/2025\/09\/ethylene-oxide-sterilization-57-scaled.webp?resize=1050%2C600&ssl=1 3x, https:\/\/i0.wp.com\/zjbocon.com\/wp-content\/uploads\/2025\/09\/ethylene-oxide-sterilization-57-scaled.webp?resize=1400%2C800&ssl=1 4x"},"classes":[]},{"id":9080,"url":"https:\/\/zjbocon.com\/?p=9080","url_meta":{"origin":7286,"position":1},"title":"Essential Utilities and Service Requirements for ETO Sterilizers","author":"Bocon Technical Team","date":"2026-01-20","format":false,"excerpt":"The successful operation of an Ethylene Oxide (ETO) sterilizer requires more than just the machine itself; it demands a robust infrastructure of essential utilities, safety systems, and ongoing technical support. Ensuring these requirements are met is critical for process efficiency, operator safety, and regulatory compliance (such as ISO 11135). Below\u2026","rel":"","context":"In &quot;Company News&quot;","block_context":{"text":"Company News","link":"https:\/\/zjbocon.com\/?cat=133125"},"img":{"alt_text":"","src":"https:\/\/i0.wp.com\/zjbocon.com\/wp-content\/uploads\/2024\/11\/eto-sterilizer-hzbocon-4.png?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/zjbocon.com\/wp-content\/uploads\/2024\/11\/eto-sterilizer-hzbocon-4.png?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/zjbocon.com\/wp-content\/uploads\/2024\/11\/eto-sterilizer-hzbocon-4.png?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/zjbocon.com\/wp-content\/uploads\/2024\/11\/eto-sterilizer-hzbocon-4.png?resize=700%2C400&ssl=1 2x, https:\/\/i0.wp.com\/zjbocon.com\/wp-content\/uploads\/2024\/11\/eto-sterilizer-hzbocon-4.png?resize=1050%2C600&ssl=1 3x"},"classes":[]},{"id":2076,"url":"https:\/\/zjbocon.com\/?p=2076","url_meta":{"origin":7286,"position":2},"title":"PQ in Ethylene oxide sterilization chamber","author":"Bocon Technical Team","date":"2024-10-31","format":false,"excerpt":"PQ is the stage of validation that uses Ethylene oxide sterilization chamber to demonstrate that the Ethylene oxide sterilization equipment consistently operates in accordance with predetermined acceptance criteria and the process yields a product that is sterile and meets the specified requirements.","rel":"","context":"In &quot;ETO STERILIZER&quot;","block_context":{"text":"ETO STERILIZER","link":"https:\/\/zjbocon.com\/?cat=133124"},"img":{"alt_text":"","src":"https:\/\/i0.wp.com\/zjbocon.com\/wp-content\/uploads\/2025\/09\/eto-sterilizer-1.webp?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/zjbocon.com\/wp-content\/uploads\/2025\/09\/eto-sterilizer-1.webp?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/zjbocon.com\/wp-content\/uploads\/2025\/09\/eto-sterilizer-1.webp?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/zjbocon.com\/wp-content\/uploads\/2025\/09\/eto-sterilizer-1.webp?resize=700%2C400&ssl=1 2x, https:\/\/i0.wp.com\/zjbocon.com\/wp-content\/uploads\/2025\/09\/eto-sterilizer-1.webp?resize=1050%2C600&ssl=1 3x"},"classes":[]},{"id":7277,"url":"https:\/\/zjbocon.com\/?p=7277","url_meta":{"origin":7286,"position":3},"title":"Performance Qualification(pq)-ppq in eo sterilization","author":"Bocon Technical Team","date":"2025-07-29","format":false,"excerpt":"Physical Performance Qualification (PPQ)\u2022 It shall be demonstrated that all specified acceptance criteria are reproducible throughout the entire process.How many runs should the PPQ process perform?\u2022 To demonstrate process reproducibility, at least 3 runs are required;\u2022 If 3 half-cycles were run during the MPQ process, then at least 1 additional\u2026","rel":"","context":"In &quot;Company News&quot;","block_context":{"text":"Company News","link":"https:\/\/zjbocon.com\/?cat=133125"},"img":{"alt_text":"","src":"https:\/\/i0.wp.com\/zjbocon.com\/wp-content\/uploads\/2025\/09\/eto-sterilizer-11.webp?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/zjbocon.com\/wp-content\/uploads\/2025\/09\/eto-sterilizer-11.webp?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/zjbocon.com\/wp-content\/uploads\/2025\/09\/eto-sterilizer-11.webp?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/zjbocon.com\/wp-content\/uploads\/2025\/09\/eto-sterilizer-11.webp?resize=700%2C400&ssl=1 2x, https:\/\/i0.wp.com\/zjbocon.com\/wp-content\/uploads\/2025\/09\/eto-sterilizer-11.webp?resize=1050%2C600&ssl=1 3x"},"classes":[]},{"id":2332,"url":"https:\/\/zjbocon.com\/?p=2332","url_meta":{"origin":7286,"position":4},"title":"Terms and definitions of eto gas sterilization","author":"Bocon Technical Team","date":"2024-11-26","format":false,"excerpt":"For the purposes of this document, the following terms and definitions apply in ethylene oxide sterilization 3.1 Aeration part of the eto gas sterilization process during which ethylene oxide and\/or its reaction products desorb from the medical device until predetermined levels are reached \u00a0 Note 1 to entry: This can\u2026","rel":"","context":"In &quot;ETO STERILIZER&quot;","block_context":{"text":"ETO STERILIZER","link":"https:\/\/zjbocon.com\/?cat=133124"},"img":{"alt_text":"","src":"https:\/\/i0.wp.com\/zjbocon.com\/wp-content\/uploads\/2025\/09\/eto-sterilizer-11.webp?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/zjbocon.com\/wp-content\/uploads\/2025\/09\/eto-sterilizer-11.webp?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/zjbocon.com\/wp-content\/uploads\/2025\/09\/eto-sterilizer-11.webp?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/zjbocon.com\/wp-content\/uploads\/2025\/09\/eto-sterilizer-11.webp?resize=700%2C400&ssl=1 2x, https:\/\/i0.wp.com\/zjbocon.com\/wp-content\/uploads\/2025\/09\/eto-sterilizer-11.webp?resize=1050%2C600&ssl=1 3x"},"classes":[]},{"id":2138,"url":"https:\/\/zjbocon.com\/?p=2138","url_meta":{"origin":7286,"position":5},"title":"ETO Sterilization Chamber Testing","author":"Bocon Technical Team","date":"2024-11-07","format":false,"excerpt":"The temperature setting range of the ETO Sterilization Chamber should be between 30-60\u00b0C. It is recommended to perform temperature distribution testing of the sterilizer's internal surface and temperature and humidity distribution testing inside the sterilization chamber to ensure the effectiveness of the heating and humidifying systems.","rel":"","context":"In &quot;ETO STERILIZER&quot;","block_context":{"text":"ETO STERILIZER","link":"https:\/\/zjbocon.com\/?cat=133124"},"img":{"alt_text":"","src":"https:\/\/i0.wp.com\/zjbocon.com\/wp-content\/uploads\/2025\/09\/cropped-cropped-hzbocon.png?resize=350%2C200&ssl=1","width":350,"height":200},"classes":[]}],"_links":{"self":[{"href":"https:\/\/zjbocon.com\/index.php?rest_route=\/wp\/v2\/posts\/7286","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/zjbocon.com\/index.php?rest_route=\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/zjbocon.com\/index.php?rest_route=\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/zjbocon.com\/index.php?rest_route=\/wp\/v2\/users\/234312599"}],"replies":[{"embeddable":true,"href":"https:\/\/zjbocon.com\/index.php?rest_route=%2Fwp%2Fv2%2Fcomments&post=7286"}],"version-history":[{"count":12,"href":"https:\/\/zjbocon.com\/index.php?rest_route=\/wp\/v2\/posts\/7286\/revisions"}],"predecessor-version":[{"id":8613,"href":"https:\/\/zjbocon.com\/index.php?rest_route=\/wp\/v2\/posts\/7286\/revisions\/8613"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/zjbocon.com\/index.php?rest_route=\/wp\/v2\/media\/8487"}],"wp:attachment":[{"href":"https:\/\/zjbocon.com\/index.php?rest_route=%2Fwp%2Fv2%2Fmedia&parent=7286"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/zjbocon.com\/index.php?rest_route=%2Fwp%2Fv2%2Fcategories&post=7286"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/zjbocon.com\/index.php?rest_route=%2Fwp%2Fv2%2Ftags&post=7286"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}