{"id":2448,"date":"2024-12-20T10:40:39","date_gmt":"2024-12-20T02:40:39","guid":{"rendered":"https:\/\/zjbocon.com\/?p=2448"},"modified":"2025-12-05T10:53:12","modified_gmt":"2025-12-05T02:53:12","slug":"eto-sterilization-chamber-temperature-distribution-testing","status":"publish","type":"post","link":"https:\/\/zjbocon.com\/?p=2448","title":{"rendered":"eto sterilization Chamber Temperature Distribution Testing"},"content":{"rendered":"\n<div class=\"wp-block-uagb-image uagb-block-b7b2c0b4 wp-block-uagb-image--layout-default wp-block-uagb-image--effect-static wp-block-uagb-image--align-none\"><figure class=\"wp-block-uagb-image__figure\"><img loading=\"lazy\" decoding=\"async\" src=\"https:\/\/zjbocon.com\/wp-content\/uploads\/2025\/09\/ethylene-oxide-sterilization-54-225x300.webp\" alt=\"\" class=\"uag-image-8460\" width=\"225\" height=\"300\" title=\"ethylene-oxide-sterilization-54\" role=\"img\" \><\/figure><\/div>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"h-c-1-temperature-testing-of-inner-surfaces-in-the-eto-sterilization-chamber\">C.1 Hitaprófun á innri yfirborði í eto dauðhreinsunarklefanum<\/h2>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"h-c-1-1\">C.1.1<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Hitastig dæmigerðra svæða á innra yfirborði skal mæla og skrá með því að nota hitaskráningartæki sem uppfylla kröfur viðauka B.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"h-c-1-2\">C.1.2<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Hvert innra yfirborð verður að mæla að minnsta kosti einu sinni (þ.e.a.s. að lágmarki 6 samstilltir mælipunktar). Fyrir dauðhreinsunartæki með heildarrúmmál á milli 300 L og 8000 L skal mæla hvert yfirborð að minnsta kosti 2 sinnum. Fyrir hverja 4000 L til viðbótar af heildarrúmmáli ætti að bæta við 6 samstilltum mælipunktum til viðbótar.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"h-c-1-3\">C.1.3<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Þessi prófun ætti að fara fram með eto dauðhreinsunarhólfið tómt og hurðir lokaðar, þó að aukabúnaður sem nauðsynlegur er fyrir eo dauðhreinsunarferlið gæti verið settur upp í hólfinu.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"h-c-1-4\">C.1.4<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Skrá skal hitastigið sem framleiðandi tilgreinir fyrir hvaða forhitunarstig sem er.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"h-c-2-temperature-testing-of-empty-eto-sterilization-chamber\">C.2 Hitaprófun á tómu ófrjósemishólfi<\/h2>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"h-c-2-1\">C.2.1<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Notaðu hitaskráningartæki sem eru í samræmi við viðauka B, skal skrá hitastig dæmigerðra svæða í nothæfu rými eo dauðhreinsunarhólfsins.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"h-c-2-2\">C.2.2<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Það ættu að vera að minnsta kosti 6 samstilltir mælipunktar. Fyrir dauðhreinsunartæki með heildarrúmmál á milli 300 L og 8000 L, ætti að gera að minnsta kosti 12 mælingar samtímis; fyrir hverja 4000 L til viðbótar ætti að bæta við 6 samstilltum mælistöðum til viðbótar. Athugið að mælisvæðið ætti að innihalda svæði innan nothæfs etýlenoxíðs dauðhreinsunarhólfs þar sem hitasveiflur geta verið mjög miklar (svæði með miklum hitabreytingum), svo sem óupphituð svæði nálægt hurð ófrjósemishólfsins og svæði nálægt gufuinnsprautunarstöðum.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"h-c-2-3\">C.2.3<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Meðan á prófun stendur ætti dauðhreinsunarhólfið að vera tómt en hugsanlega eru aukabúnaður sem nauðsynlegur er fyrir etýlenoxíð dauðhreinsunarferlið uppsettur, með hurðirnar á etýlenoxíð dauðhreinsunarhólfinu lokaðar.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"h-c-2-4\">C.2.4<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Í gegnum alla etýlenoxíð dauðhreinsunarferilinn ætti að skrá staðsetningu hverrar hitastigsmælingar, þar sem hitastigið á ýmsum svæðum í eo dauðhreinsunarhólfinu er lýst.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Athugið:<\/strong> Í þessari prófun má nota óeitraðar, eldfimmar lofttegundir eða blöndur í staðinn fyrir dauðhreinsunarefnið sem sprautað er inn í eto dauðhreinsunarhólfið í gegnum etýlenoxíð innspýtingarkerfið (þar á meðal gufutæki).<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"h-if-you-want-to-know-more-about-ethylene-oxide-sterilization\">EF ÞÚ VILT VITA MEIRA Um etýlenoxíð ófrjósemisaðgerð<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Sími:<a href=\"https:\/\/wa.me\/8619975258603\">+8619975258603<\/a><\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Netfang:<a href=\"mailto:hayley@hzbocon.com\">hayley@hzbocon.com<\/a><\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Staðbundin staður: Herbergi 1202, Caitong Zhongxin, Xiasha District, Hangzhou City, Zhejiang Province, Kína<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Vefsíða:<a href=\"https:\/\/www.hzbocon.com\/\">hzbocon.com<\/a><a href=\"https:\/\/zjbocon.com\/\">&nbsp;zjbocon.com<\/a><\/p>\n","protected":false},"excerpt":{"rendered":"<p>Hitastig dæmigerðra svæða á innra yfirborði skal mæla og skrá með því að nota hitaskráningartæki sem uppfylla kröfur viðauka B.<\/p>\n","protected":false},"author":234312599,"featured_media":8460,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_uag_custom_page_level_css":"","site-sidebar-layout":"default","site-content-layout":"","ast-site-content-layout":"default","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","ast-disable-related-posts":"","theme-transparent-header-meta":"","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"set","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"_jetpack_newsletter_access":"","_jetpack_dont_email_post_to_subs":false,"_jetpack_newsletter_tier_id":0,"_jetpack_memberships_contains_paywalled_content":false,"_jetpack_feature_clip_id":0,"_jetpack_memberships_contains_paid_content":false,"footnotes":"","jetpack_publicize_message":"","jetpack_publicize_feature_enabled":true,"jetpack_social_post_already_shared":false,"jetpack_social_options":{"image_generator_settings":{"template":"highway","enabled":false},"version":2},"jetpack_post_was_ever_published":false},"categories":[133125,133124],"tags":[],"class_list":["post-2448","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-company-news","category-eto-sterilizer"],"yoast_head":"<!-- This site is optimized with the Yoast SEO Premium plugin v27.2 (Yoast SEO v28.0) - https:\/\/yoast.com\/product\/yoast-seo-premium-wordpress\/ -->\n<title>eto dauðhreinsun Chamber Hitastigsdreifingarprófun - ETO STERILIZER<\/title>\n<meta name=\"description\" content=\"C.1 Temperature Testing of Inner Surfaces in the eto Sterilization Chamber C.2 Empty Chamber\" \>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \>\n<link rel=\"canonical\" href=\"https:\/\/zjbocon.com\/?p=2448\" \>\n<meta property=\"og:locale\" content=\"is_IS\" \>\n<meta property=\"og:type\" content=\"article\" \>\n<meta property=\"og:title\" content=\"eto sterilization Chamber Temperature Distribution Testing\" \>\n<meta property=\"og:description\" content=\"C.1 Temperature Testing of Inner Surfaces in the eto Sterilization Chamber C.2 Empty Chamber\" \>\n<meta property=\"og:url\" content=\"https:\/\/zjbocon.com\/?p=2448\" \>\n<meta property=\"og:site_name\" content=\"ETO STERILIZER\" \>\n<meta property=\"article:publisher\" content=\"https:\/\/www.facebook.com\/profile.php?id=100088482339878\" \>\n<meta property=\"article:author\" content=\"https:\/\/www.facebook.com\/profile.php?id=100088482339878\" \>\n<meta property=\"article:published_time\" content=\"2024-12-20T02:40:39+00:00\" \>\n<meta property=\"article:modified_time\" content=\"2025-12-05T02:53:12+00:00\" \>\n<meta property=\"og:image\" content=\"https:\/\/zjbocon.com\/wp-content\/uploads\/2025\/09\/ethylene-oxide-sterilization-54.webp\" \>\n\t<meta property=\"og:image:width\" content=\"1279\" \>\n\t<meta property=\"og:image:height\" content=\"1706\" \>\n\t<meta property=\"og:image:type\" content=\"image\/webp\" \>\n<meta name=\"author\" content=\"Bocon Technical Team\" \>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \>\n<meta name=\"twitter:creator\" content=\"@BoconAnd\" \>\n<meta name=\"twitter:site\" content=\"@BoconAnd\" \>\n<meta name=\"twitter:label1\" content=\"Written by\" \>\n\t<meta name=\"twitter:data1\" content=\"Bocon Technical Team\" \>\n\t<meta name=\"twitter:label2\" content=\"Est. reading time\" \>\n\t<meta name=\"twitter:data2\" content=\"3 minutes\" \>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\\\/\\\/zjbocon.com\\\/?p=2448#article\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/zjbocon.com\\\/?p=2448\"},\"author\":{\"name\":\"Bocon Technical Team\",\"@id\":\"https:\\\/\\\/zjbocon.com\\\/#\\\/schema\\\/person\\\/f12be028b8ae9843a4396dcc8012b425\"},\"headline\":\"eto sterilization Chamber Temperature Distribution Testing\",\"datePublished\":\"2024-12-20T02:40:39+00:00\",\"dateModified\":\"2025-12-05T02:53:12+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/zjbocon.com\\\/?p=2448\"},\"wordCount\":383,\"commentCount\":0,\"publisher\":{\"@id\":\"https:\\\/\\\/zjbocon.com\\\/#organization\"},\"image\":{\"@id\":\"https:\\\/\\\/zjbocon.com\\\/?p=2448#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/zjbocon.com\\\/wp-content\\\/uploads\\\/2025\\\/09\\\/ethylene-oxide-sterilization-54.webp\",\"articleSection\":[\"Company News\",\"ETO STERILIZER\"],\"inLanguage\":\"is\",\"potentialAction\":[{\"@type\":\"CommentAction\",\"name\":\"Comment\",\"target\":[\"https:\\\/\\\/zjbocon.com\\\/?p=2448#respond\"]}]},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/zjbocon.com\\\/?p=2448\",\"url\":\"https:\\\/\\\/zjbocon.com\\\/?p=2448\",\"name\":\"eto sterilization Chamber Temperature Distribution Testing - ETO STERILIZER\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/zjbocon.com\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/zjbocon.com\\\/?p=2448#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/zjbocon.com\\\/?p=2448#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/zjbocon.com\\\/wp-content\\\/uploads\\\/2025\\\/09\\\/ethylene-oxide-sterilization-54.webp\",\"datePublished\":\"2024-12-20T02:40:39+00:00\",\"dateModified\":\"2025-12-05T02:53:12+00:00\",\"description\":\"C.1 Temperature Testing of Inner Surfaces in the eto Sterilization Chamber C.2 Temperature Testing of Empty eto Sterilization Chamber\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/zjbocon.com\\\/?p=2448#breadcrumb\"},\"inLanguage\":\"is\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/zjbocon.com\\\/?p=2448\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"is\",\"@id\":\"https:\\\/\\\/zjbocon.com\\\/?p=2448#primaryimage\",\"url\":\"https:\\\/\\\/zjbocon.com\\\/wp-content\\\/uploads\\\/2025\\\/09\\\/ethylene-oxide-sterilization-54.webp\",\"contentUrl\":\"https:\\\/\\\/zjbocon.com\\\/wp-content\\\/uploads\\\/2025\\\/09\\\/ethylene-oxide-sterilization-54.webp\",\"width\":1279,\"height\":1706},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/zjbocon.com\\\/?p=2448#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/zjbocon.com\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"eto sterilization Chamber Temperature Distribution Testing\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/zjbocon.com\\\/#website\",\"url\":\"https:\\\/\\\/zjbocon.com\\\/\",\"name\":\"ETO STERILIZER\",\"description\":\"One-stop Solution Supplier of Ethylene Oxide Sterilization\",\"publisher\":{\"@id\":\"https:\\\/\\\/zjbocon.com\\\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/zjbocon.com\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"is\"},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/zjbocon.com\\\/#organization\",\"name\":\"ETO STERILIZER\",\"url\":\"https:\\\/\\\/zjbocon.com\\\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"is\",\"@id\":\"https:\\\/\\\/zjbocon.com\\\/#\\\/schema\\\/logo\\\/image\\\/\",\"url\":\"https:\\\/\\\/zjbocon.com\\\/wp-content\\\/uploads\\\/2024\\\/10\\\/logo-1.webp\",\"contentUrl\":\"https:\\\/\\\/zjbocon.com\\\/wp-content\\\/uploads\\\/2024\\\/10\\\/logo-1.webp\",\"width\":180,\"height\":60,\"caption\":\"ETO STERILIZER\"},\"image\":{\"@id\":\"https:\\\/\\\/zjbocon.com\\\/#\\\/schema\\\/logo\\\/image\\\/\"},\"sameAs\":[\"https:\\\/\\\/www.facebook.com\\\/profile.php?id=100088482339878\",\"https:\\\/\\\/x.com\\\/BoconAnd\",\"https:\\\/\\\/www.linkedin.com\\\/in\\\/--06a221139\\\/\"]},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/zjbocon.com\\\/#\\\/schema\\\/person\\\/f12be028b8ae9843a4396dcc8012b425\",\"name\":\"Bocon Technical Team\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"is\",\"@id\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/d7a825658be227f26b237e519f8541e05aabc9ff27b8eec4544a233a48c53be0?s=96&d=identicon&r=g\",\"url\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/d7a825658be227f26b237e519f8541e05aabc9ff27b8eec4544a233a48c53be0?s=96&d=identicon&r=g\",\"contentUrl\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/d7a825658be227f26b237e519f8541e05aabc9ff27b8eec4544a233a48c53be0?s=96&d=identicon&r=g\",\"caption\":\"Bocon Technical Team\"},\"sameAs\":[\"https:\\\/\\\/zjbocon.com\\\/\",\"https:\\\/\\\/www.facebook.com\\\/profile.php?id=100088482339878\",\"https:\\\/\\\/www.linkedin.com\\\/in\\\/\\\/hayley--968190269\\\/\"],\"url\":\"https:\\\/\\\/zjbocon.com\\\/?author=234312599\"}]}<\/script>\n<!-- \/ Yoast SEO Premium plugin. -->","yoast_head_json":{"title":"eto sterilization Chamber Temperature Distribution Testing - ETO STERILIZER","description":"C.1 Temperature Testing of Inner Surfaces in the eto Sterilization Chamber C.2 Temperature Testing of Empty eto Sterilization Chamber","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/zjbocon.com\/?p=2448","og_locale":"is_IS","og_type":"article","og_title":"eto sterilization Chamber Temperature Distribution Testing","og_description":"C.1 Temperature Testing of Inner Surfaces in the eto Sterilization Chamber C.2 Temperature Testing of Empty eto Sterilization Chamber","og_url":"https:\/\/zjbocon.com\/?p=2448","og_site_name":"ETO STERILIZER","article_publisher":"https:\/\/www.facebook.com\/profile.php?id=100088482339878","article_author":"https:\/\/www.facebook.com\/profile.php?id=100088482339878","article_published_time":"2024-12-20T02:40:39+00:00","article_modified_time":"2025-12-05T02:53:12+00:00","og_image":[{"width":1279,"height":1706,"url":"https:\/\/zjbocon.com\/wp-content\/uploads\/2025\/09\/ethylene-oxide-sterilization-54.webp","type":"image\/webp"}],"author":"Bocon Technical Team","twitter_card":"summary_large_image","twitter_creator":"@BoconAnd","twitter_site":"@BoconAnd","twitter_misc":{"Written by":"Bocon Technical Team","Est. reading time":"3 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/zjbocon.com\/?p=2448#article","isPartOf":{"@id":"https:\/\/zjbocon.com\/?p=2448"},"author":{"name":"Bocon Technical Team","@id":"https:\/\/zjbocon.com\/#\/schema\/person\/f12be028b8ae9843a4396dcc8012b425"},"headline":"eto sterilization Chamber Temperature Distribution Testing","datePublished":"2024-12-20T02:40:39+00:00","dateModified":"2025-12-05T02:53:12+00:00","mainEntityOfPage":{"@id":"https:\/\/zjbocon.com\/?p=2448"},"wordCount":383,"commentCount":0,"publisher":{"@id":"https:\/\/zjbocon.com\/#organization"},"image":{"@id":"https:\/\/zjbocon.com\/?p=2448#primaryimage"},"thumbnailUrl":"https:\/\/zjbocon.com\/wp-content\/uploads\/2025\/09\/ethylene-oxide-sterilization-54.webp","articleSection":["Company News","ETO STERILIZER"],"inLanguage":"is","potentialAction":[{"@type":"CommentAction","name":"Comment","target":["https:\/\/zjbocon.com\/?p=2448#respond"]}]},{"@type":"WebPage","@id":"https:\/\/zjbocon.com\/?p=2448","url":"https:\/\/zjbocon.com\/?p=2448","name":"eto sterilization Chamber Temperature Distribution Testing - ETO STERILIZER","isPartOf":{"@id":"https:\/\/zjbocon.com\/#website"},"primaryImageOfPage":{"@id":"https:\/\/zjbocon.com\/?p=2448#primaryimage"},"image":{"@id":"https:\/\/zjbocon.com\/?p=2448#primaryimage"},"thumbnailUrl":"https:\/\/zjbocon.com\/wp-content\/uploads\/2025\/09\/ethylene-oxide-sterilization-54.webp","datePublished":"2024-12-20T02:40:39+00:00","dateModified":"2025-12-05T02:53:12+00:00","description":"C.1 Temperature Testing of Inner Surfaces in the eto Sterilization Chamber C.2 Temperature Testing of Empty eto Sterilization Chamber","breadcrumb":{"@id":"https:\/\/zjbocon.com\/?p=2448#breadcrumb"},"inLanguage":"is","potentialAction":[{"@type":"ReadAction","target":["https:\/\/zjbocon.com\/?p=2448"]}]},{"@type":"ImageObject","inLanguage":"is","@id":"https:\/\/zjbocon.com\/?p=2448#primaryimage","url":"https:\/\/zjbocon.com\/wp-content\/uploads\/2025\/09\/ethylene-oxide-sterilization-54.webp","contentUrl":"https:\/\/zjbocon.com\/wp-content\/uploads\/2025\/09\/ethylene-oxide-sterilization-54.webp","width":1279,"height":1706},{"@type":"BreadcrumbList","@id":"https:\/\/zjbocon.com\/?p=2448#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/zjbocon.com\/"},{"@type":"ListItem","position":2,"name":"eto sterilization Chamber Temperature Distribution Testing"}]},{"@type":"WebSite","@id":"https:\/\/zjbocon.com\/#website","url":"https:\/\/zjbocon.com\/","name":"ETO STERILIZER","description":"One-stop Solution Supplier of Ethylene Oxide Sterilization","publisher":{"@id":"https:\/\/zjbocon.com\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/zjbocon.com\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"is"},{"@type":"Organization","@id":"https:\/\/zjbocon.com\/#organization","name":"ETO STERILIZER","url":"https:\/\/zjbocon.com\/","logo":{"@type":"ImageObject","inLanguage":"is","@id":"https:\/\/zjbocon.com\/#\/schema\/logo\/image\/","url":"https:\/\/zjbocon.com\/wp-content\/uploads\/2024\/10\/logo-1.webp","contentUrl":"https:\/\/zjbocon.com\/wp-content\/uploads\/2024\/10\/logo-1.webp","width":180,"height":60,"caption":"ETO STERILIZER"},"image":{"@id":"https:\/\/zjbocon.com\/#\/schema\/logo\/image\/"},"sameAs":["https:\/\/www.facebook.com\/profile.php?id=100088482339878","https:\/\/x.com\/BoconAnd","https:\/\/www.linkedin.com\/in\/--06a221139\/"]},{"@type":"Person","@id":"https:\/\/zjbocon.com\/#\/schema\/person\/f12be028b8ae9843a4396dcc8012b425","name":"Bocon Technical Team","image":{"@type":"ImageObject","inLanguage":"is","@id":"https:\/\/secure.gravatar.com\/avatar\/d7a825658be227f26b237e519f8541e05aabc9ff27b8eec4544a233a48c53be0?s=96&d=identicon&r=g","url":"https:\/\/secure.gravatar.com\/avatar\/d7a825658be227f26b237e519f8541e05aabc9ff27b8eec4544a233a48c53be0?s=96&d=identicon&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/d7a825658be227f26b237e519f8541e05aabc9ff27b8eec4544a233a48c53be0?s=96&d=identicon&r=g","caption":"Bocon Technical Team"},"sameAs":["https:\/\/zjbocon.com\/","https:\/\/www.facebook.com\/profile.php?id=100088482339878","https:\/\/www.linkedin.com\/in\/\/hayley--968190269\/"],"url":"https:\/\/zjbocon.com\/?author=234312599"}]}},"jetpack_publicize_connections":[],"jetpack_featured_media_url":"https:\/\/zjbocon.com\/wp-content\/uploads\/2025\/09\/ethylene-oxide-sterilization-54.webp","uagb_featured_image_src":{"full":["https:\/\/zjbocon.com\/wp-content\/uploads\/2025\/09\/ethylene-oxide-sterilization-54.webp",1279,1706,false],"thumbnail":["https:\/\/zjbocon.com\/wp-content\/uploads\/2025\/09\/ethylene-oxide-sterilization-54-150x150.webp",150,150,true],"medium":["https:\/\/zjbocon.com\/wp-content\/uploads\/2025\/09\/ethylene-oxide-sterilization-54-225x300.webp",225,300,true],"medium_large":["https:\/\/zjbocon.com\/wp-content\/uploads\/2025\/09\/ethylene-oxide-sterilization-54-768x1024.webp",768,1024,true],"large":["https:\/\/zjbocon.com\/wp-content\/uploads\/2025\/09\/ethylene-oxide-sterilization-54-768x1024.webp",768,1024,true],"1536x1536":["https:\/\/zjbocon.com\/wp-content\/uploads\/2025\/09\/ethylene-oxide-sterilization-54-1152x1536.webp",1152,1536,true],"2048x2048":["https:\/\/zjbocon.com\/wp-content\/uploads\/2025\/09\/ethylene-oxide-sterilization-54.webp",1279,1706,false],"woocommerce_thumbnail":["https:\/\/zjbocon.com\/wp-content\/uploads\/2025\/09\/ethylene-oxide-sterilization-54-600x600.webp",600,600,true],"woocommerce_single":["https:\/\/zjbocon.com\/wp-content\/uploads\/2025\/09\/ethylene-oxide-sterilization-54-600x800.webp",600,800,true],"woocommerce_gallery_thumbnail":["https:\/\/zjbocon.com\/wp-content\/uploads\/2025\/09\/ethylene-oxide-sterilization-54-100x100.webp",100,100,true]},"uagb_author_info":{"display_name":"Bocon Technical Team","author_link":"https:\/\/zjbocon.com\/?author=234312599"},"uagb_comment_info":24,"uagb_excerpt":"The temperature of representative areas on the inner surfaces should be measured and recorded using temperature recording instruments that comply with the requirements of Appendix B.","jetpack_likes_enabled":true,"jetpack_sharing_enabled":true,"jetpack_shortlink":"https:\/\/wp.me\/pgZDV6-Du","jetpack-related-posts":[{"id":2492,"url":"https:\/\/zjbocon.com\/?p=2492","url_meta":{"origin":2448,"position":0},"title":"Understanding ETO Sterilizer Performance: Keys to Efficiency","author":"Bocon Technical Team","date":"2024-12-24","format":false,"excerpt":"3.4.1 eto sterilizer machine Temperature Setting Range The temperature setting range for the eto sterilizer is: 30 to 70\u00b0C","rel":"","context":"In &quot;Company News&quot;","block_context":{"text":"Company News","link":"https:\/\/zjbocon.com\/?cat=133125"},"img":{"alt_text":"","src":"https:\/\/i0.wp.com\/zjbocon.com\/wp-content\/uploads\/2025\/09\/eto-sterilizer-1.webp?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/zjbocon.com\/wp-content\/uploads\/2025\/09\/eto-sterilizer-1.webp?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/zjbocon.com\/wp-content\/uploads\/2025\/09\/eto-sterilizer-1.webp?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/zjbocon.com\/wp-content\/uploads\/2025\/09\/eto-sterilizer-1.webp?resize=700%2C400&ssl=1 2x, https:\/\/i0.wp.com\/zjbocon.com\/wp-content\/uploads\/2025\/09\/eto-sterilizer-1.webp?resize=1050%2C600&ssl=1 3x"},"classes":[]},{"id":2064,"url":"https:\/\/zjbocon.com\/?p=2064","url_meta":{"origin":2448,"position":1},"title":"OQ IN ETO STERILIZATION MACHINE","author":"Bocon Technical Team","date":"2024-10-31","format":false,"excerpt":"In OQ, the performance of the relevant auxiliary system should be determined and the software system should be tested by simulating the fault conditions.","rel":"","context":"In &quot;ETO STERILIZER&quot;","block_context":{"text":"ETO STERILIZER","link":"https:\/\/zjbocon.com\/?cat=133124"},"img":{"alt_text":"","src":"https:\/\/i0.wp.com\/zjbocon.com\/wp-content\/uploads\/2025\/09\/Ethylene-Oxide-Sterilizer-Installation-Guide-1-scaled.webp?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/zjbocon.com\/wp-content\/uploads\/2025\/09\/Ethylene-Oxide-Sterilizer-Installation-Guide-1-scaled.webp?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/zjbocon.com\/wp-content\/uploads\/2025\/09\/Ethylene-Oxide-Sterilizer-Installation-Guide-1-scaled.webp?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/zjbocon.com\/wp-content\/uploads\/2025\/09\/Ethylene-Oxide-Sterilizer-Installation-Guide-1-scaled.webp?resize=700%2C400&ssl=1 2x, https:\/\/i0.wp.com\/zjbocon.com\/wp-content\/uploads\/2025\/09\/Ethylene-Oxide-Sterilizer-Installation-Guide-1-scaled.webp?resize=1050%2C600&ssl=1 3x, https:\/\/i0.wp.com\/zjbocon.com\/wp-content\/uploads\/2025\/09\/Ethylene-Oxide-Sterilizer-Installation-Guide-1-scaled.webp?resize=1400%2C800&ssl=1 4x"},"classes":[]},{"id":2138,"url":"https:\/\/zjbocon.com\/?p=2138","url_meta":{"origin":2448,"position":2},"title":"ETO Sterilization Chamber Testing","author":"Bocon Technical Team","date":"2024-11-07","format":false,"excerpt":"The temperature setting range of the ETO Sterilization Chamber should be between 30-60\u00b0C. It is recommended to perform temperature distribution testing of the sterilizer's internal surface and temperature and humidity distribution testing inside the sterilization chamber to ensure the effectiveness of the heating and humidifying systems.","rel":"","context":"In &quot;ETO STERILIZER&quot;","block_context":{"text":"ETO STERILIZER","link":"https:\/\/zjbocon.com\/?cat=133124"},"img":{"alt_text":"","src":"https:\/\/i0.wp.com\/zjbocon.com\/wp-content\/uploads\/2025\/09\/cropped-cropped-hzbocon.png?resize=350%2C200&ssl=1","width":350,"height":200},"classes":[]},{"id":1989,"url":"https:\/\/zjbocon.com\/?p=1989","url_meta":{"origin":2448,"position":3},"title":"The Detail Of EtO Sterilization Cycle\u00a0","author":"Bocon Technical Team","date":"2024-10-25","format":false,"excerpt":"The Detail EtO Sterilization Cycle\u00a0 A typical EtO sterilization cycle comprises three main stages: Preconditioning This stage prepares the chamber to create optimal conditions for temperature, pressure, and humidity. \u00a0First, air is evacuated to enhance gas penetration, followed by a leakage test to ensure safety for personnel and the environment.\u2026","rel":"","context":"In &quot;ETO STERILIZER&quot;","block_context":{"text":"ETO STERILIZER","link":"https:\/\/zjbocon.com\/?cat=133124"},"img":{"alt_text":"","src":"https:\/\/i0.wp.com\/zjbocon.com\/wp-content\/uploads\/2024\/10\/turn-key-solution.webp?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/zjbocon.com\/wp-content\/uploads\/2024\/10\/turn-key-solution.webp?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/zjbocon.com\/wp-content\/uploads\/2024\/10\/turn-key-solution.webp?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/zjbocon.com\/wp-content\/uploads\/2024\/10\/turn-key-solution.webp?resize=700%2C400&ssl=1 2x"},"classes":[]},{"id":1950,"url":"https:\/\/zjbocon.com\/?p=1950","url_meta":{"origin":2448,"position":4},"title":"eto sterilization process","author":"Bocon Technical Team","date":"2024-10-23","format":false,"excerpt":"Eto Sterilization is conducted using a eto sterilizer located in a dedicated facility.","rel":"","context":"In &quot;ETO STERILIZER&quot;","block_context":{"text":"ETO STERILIZER","link":"https:\/\/zjbocon.com\/?cat=133124"},"img":{"alt_text":"eto sterilization process","src":"https:\/\/i0.wp.com\/zjbocon.com\/wp-content\/uploads\/2024\/10\/eto-sterilization-process-e1729654271899.webp?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/zjbocon.com\/wp-content\/uploads\/2024\/10\/eto-sterilization-process-e1729654271899.webp?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/zjbocon.com\/wp-content\/uploads\/2024\/10\/eto-sterilization-process-e1729654271899.webp?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/zjbocon.com\/wp-content\/uploads\/2024\/10\/eto-sterilization-process-e1729654271899.webp?resize=700%2C400&ssl=1 2x"},"classes":[]},{"id":2004,"url":"https:\/\/zjbocon.com\/?p=2004","url_meta":{"origin":2448,"position":5},"title":"The Guide to ethylene oxide in sterilization","author":"Bocon Technical Team","date":"2024-10-28","format":false,"excerpt":"ethylene oxide in sterilization Introduction ETO is a colorless gas that is flammable and explosive. The four essential parameters (operational ranges) of ethylene oxide in sterilization are: gas concentration (450 to 1200 mg\/l); temperature (37 to 63\u00b0C); relative humidity (40 to 80%)(water molecules carry ETO to reactive sites); and exposure\u2026","rel":"","context":"In &quot;ETO STERILIZER&quot;","block_context":{"text":"ETO STERILIZER","link":"https:\/\/zjbocon.com\/?cat=133124"},"img":{"alt_text":"Industry_ETO_Sterilizer","src":"https:\/\/i0.wp.com\/zjbocon.com\/wp-content\/uploads\/2024\/10\/Industry_ETO_Sterilizer.webp?resize=350%2C200","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/zjbocon.com\/wp-content\/uploads\/2024\/10\/Industry_ETO_Sterilizer.webp?resize=350%2C200 1x, https:\/\/i0.wp.com\/zjbocon.com\/wp-content\/uploads\/2024\/10\/Industry_ETO_Sterilizer.webp?resize=525%2C300 1.5x, https:\/\/i0.wp.com\/zjbocon.com\/wp-content\/uploads\/2024\/10\/Industry_ETO_Sterilizer.webp?resize=700%2C400 2x"},"classes":[]}],"_links":{"self":[{"href":"https:\/\/zjbocon.com\/index.php?rest_route=\/wp\/v2\/posts\/2448","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/zjbocon.com\/index.php?rest_route=\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/zjbocon.com\/index.php?rest_route=\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/zjbocon.com\/index.php?rest_route=\/wp\/v2\/users\/234312599"}],"replies":[{"embeddable":true,"href":"https:\/\/zjbocon.com\/index.php?rest_route=%2Fwp%2Fv2%2Fcomments&post=2448"}],"version-history":[{"count":4,"href":"https:\/\/zjbocon.com\/index.php?rest_route=\/wp\/v2\/posts\/2448\/revisions"}],"predecessor-version":[{"id":8864,"href":"https:\/\/zjbocon.com\/index.php?rest_route=\/wp\/v2\/posts\/2448\/revisions\/8864"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/zjbocon.com\/index.php?rest_route=\/wp\/v2\/media\/8460"}],"wp:attachment":[{"href":"https:\/\/zjbocon.com\/index.php?rest_route=%2Fwp%2Fv2%2Fmedia&parent=2448"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/zjbocon.com\/index.php?rest_route=%2Fwp%2Fv2%2Fcategories&post=2448"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/zjbocon.com\/index.php?rest_route=%2Fwp%2Fv2%2Ftags&post=2448"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}