{"id":8772,"date":"2025-11-25T09:50:58","date_gmt":"2025-11-25T01:50:58","guid":{"rendered":"https:\/\/zjbocon.com\/?p=8772"},"modified":"2025-11-25T18:11:09","modified_gmt":"2025-11-25T10:11:09","slug":"eto-sterilization-safety-guidelines-best-practices-for-using-ethylene-oxide-as-a-sterilant","status":"publish","type":"post","link":"https:\/\/zjbocon.com\/?p=8772","title":{"rendered":"ETO STERILIZATION Safety Guidelines: Best Practices for Using Ethylene Oxide as a Sterilant"},"content":{"rendered":"\n<div class=\"wp-block-uagb-image uagb-block-760a4ff2 wp-block-uagb-image--layout-default wp-block-uagb-image--effect-static wp-block-uagb-image--align-none\"><figure class=\"wp-block-uagb-image__figure\"><img loading=\"lazy\" decoding=\"async\" src=\"https:\/\/cdn-ilbpffd.nitrocdn.com\/bohLJiJcgiLJnRpcarhVkxKWAakkhLNM\/assets\/images\/optimized\/rev-622c653\/zjbocon.com\/wp-content\/uploads\/2025\/09\/eto-sterilizer-4-1024x1024.webp\" alt=\"\" width=\"1024\" height=\"1024\" title=\"\" role=\"img\" \><\/figure><\/div>\n\n\n\n<p class=\"wp-block-paragraph\">Ossido di etilene (<strong>STERILIZZAZIONE ETO<\/strong>) è ampiamente utilizzato come sterilizzante a bassa temperatura in settori quali quello sanitario, farmaceutico e biotecnologico. Tuttavia, a causa della sua <strong>tossico<\/strong>, <strong>infiammabile<\/strong>, E <strong>potenzialmente cancerogeno<\/strong> proprietà, è fondamentale seguire rigorosi protocolli di sicurezza. Questo articolo delinea le linee guida di sicurezza essenziali per operare in sicurezza <strong>STERILIZZAZIONE ETO<\/strong> sistemi.<\/p>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"h-1-regulatory-compliance-for-eto-sterilization\"><strong>1. Conformità normativa per la STERILIZZAZIONE ETO<\/strong><\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Per garantire un servizio sicuro e conforme <strong>STERILIZZAZIONE ETO<\/strong> processo, le aziende devono aderire agli standard di sicurezza locali, nazionali e internazionali. Alcune normative chiave includono:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong>OSHA<\/strong>: Occupational Safety and Health Administration\u2019s regulations for worker safety when using ETO.<\/li>\n\n\n\n<li><strong>APE<\/strong>: Linee guida dell&#039;Environmental Protection Agency per gli inquinanti atmosferici pericolosi.<\/li>\n\n\n\n<li><strong>FDA<\/strong>: Linee guida FDA per l&#039;utilizzo della sterilizzazione dei dispositivi medici <strong>STERILIZZAZIONE ETO<\/strong>.<\/li>\n\n\n\n<li><strong>ISO 11135<\/strong>: Standard internazionale per la validazione e il controllo dei <strong>STERILIZZAZIONE ETO<\/strong> processi.<\/li>\n\n\n\n<li><strong>ANSI\/AAMI ST41<\/strong>: Norma per la sterilizzazione dei dispositivi medici con <strong>STERILIZZAZIONE ETO<\/strong>.<\/li>\n<\/ul>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"h-2-ventilation-and-exhaust-systems-for-eto-sterilization\"><strong>2. Sistemi di ventilazione e scarico per STERILIZZAZIONE ETO<\/strong><\/h2>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"h-proper-ventilation\"><strong>Ventilazione adeguata<\/strong><\/h3>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>STERILIZZAZIONE ETO<\/strong> comporta l&#039;uso di composti organici volatili (COV) come l&#039;ossido di etilene, che può essere dannoso se inalato. Per prevenire è essenziale una ventilazione adeguata <strong>ALLINEAMENTO<\/strong> accumulo nella sala di sterilizzazione e nelle aree circostanti.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"h-local-exhaust-ventilation-lev\"><strong>Ventilazione di scarico locale (LEV)<\/strong><\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Installare un sistema di ventilazione di scarico locale per catturare qualsiasi potenziale <strong>Fuga di gas ETO<\/strong> durante i cicli di sterilizzazione, manutenzione o emergenze.<\/p>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"h-3-continuous-gas-monitoring-during-eto-sterilization\"><strong>3. Monitoraggio continuo del gas durante la STERILIZZAZIONE ETO<\/strong><\/h2>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"h-eto-gas-detection\"><strong>Rilevamento gas ETO<\/strong><\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Installazione continua <strong>Rilevatori di gas ETO<\/strong> per monitorare la concentrazione di ossido di etilene nell&#039;aria. La calibrazione di questi rilevatori è fondamentale per garantire letture accurate.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"h-alarm-systems\"><strong>Sistemi di allarme<\/strong><\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Equipaggiare <strong>STERILIZZAZIONE ETO<\/strong> sistemi con allarmi che avvisano gli operatori quando <strong>ALLINEAMENTO<\/strong> le concentrazioni di gas superano i limiti di sicurezza. La soglia è generalmente fissata a 1 ppm (parti per milione) per una media ponderata nel tempo (TWA) di 8 ore.<\/p>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"h-4-personal-protective-equipment-ppe-for-eto-sterilization-operators\"><strong>4. Dispositivi di Protezione Individuale (DPI) per gli Operatori della STERILIZZAZIONE ETO<\/strong><\/h2>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"h-protective-clothing\"><strong>Indumenti protettivi<\/strong><\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Movimentazione degli operatori <strong>STERILIZZAZIONE ETO<\/strong> i sistemi devono usurarsi <strong>camici da laboratorio impermeabili<\/strong> o tute per proteggersi dall&#039;esposizione della pelle all&#039;OE.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"h-respiratory-protection\"><strong>Protezione respiratoria<\/strong><\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Quando si lavora in aree in cui <strong>Concentrazioni di gas ETO<\/strong> potrebbe essere superiore a quanto raccomandato, gli operatori dovrebbero utilizzarlo <strong>respiratori<\/strong> dotati di filtri adatti all&#039;ossido di etilene.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"h-gloves-and-safety-goggles\"><strong>Guanti e occhiali di sicurezza<\/strong><\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Oltre agli indumenti protettivi, gli operatori dovrebbero indossare <strong>guanti resistenti agli agenti chimici<\/strong> E <strong>occhiali di sicurezza<\/strong> per evitare il contatto diretto con <strong>ALLINEAMENTO<\/strong>.<\/p>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"h-5-safe-handling-and-storage-of-eto-gas\"><strong>5. Manipolazione e stoccaggio sicuri del gas ETO<\/strong><\/h2>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"h-safe-storage-practices\"><strong>Pratiche di conservazione sicura<\/strong><\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Negozio <strong>Bombole di gas ETO<\/strong> in aree ben ventilate, fresche, asciutte e sicure, lontano dalla luce solare diretta, da fonti di calore o da materiali infiammabili. Le aree di stoccaggio dovrebbero essere chiaramente etichettate come pericolose.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"h-handling-protocols\"><strong>Protocolli di gestione<\/strong><\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">La manipolazione deve essere effettuata solo da personale addestrato <strong>Cilindri ETO<\/strong>. Assicurarsi che tutte le valvole, i regolatori e i collegamenti siano mantenuti correttamente per evitare perdite di gas.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"h-safety-data-sheets-sds\"><strong>Schede di sicurezza (SDS)<\/strong><\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Avere sempre il <strong>Scheda dati di sicurezza ETO (SDS)<\/strong> disponibile, che fornisce informazioni importanti sulla gestione, il primo soccorso, la risposta alle emergenze e i potenziali pericoli.<\/p>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"h-6-leak-prevention-and-detection-in-eto-sterilization-systems\"><strong>6. Prevenzione e rilevamento delle perdite nei sistemi di STERILIZZAZIONE ETO<\/strong><\/h2>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"h-regular-leak-checks\"><strong>Controlli regolari delle perdite<\/strong><\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Ispezionare regolarmente le camere di sterilizzazione, le linee di alimentazione del gas e le guarnizioni <strong>Fuga di gas ETO<\/strong>. Assicurarsi che ogni possibile punto di perdita venga tempestivamente risolto per prevenire l&#039;esposizione.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"h-leak-testing-procedures\"><strong>Procedure di prova delle perdite<\/strong><\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Prima, durante e dopo ciascun ciclo di sterilizzazione, eseguire <strong>test di tenuta<\/strong> per rilevarne qualcuno <strong>Fuga di gas ETO<\/strong>. Ciò garantisce che le apparecchiature di sterilizzazione funzionino in sicurezza.<\/p>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"h-7-exposure-limits-and-air-quality-control-during-eto-sterilization\"><strong>7. Limiti di esposizione e controllo della qualità dell&#039;aria durante la STERILIZZAZIONE ETO<\/strong><\/h2>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"h-workplace-exposure-limits-pel\"><strong>Limiti di esposizione sul posto di lavoro (PEL)<\/strong><\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Il limite di esposizione consentito (PEL) per <strong>gas ETO<\/strong> in the workplace is generally 1 ppm over an 8-hour workday, with a short-term exposure limit (STEL) of 5 ppm. It\u2019s essential to ensure that <strong>STERILIZZAZIONE ETO<\/strong> le operazioni restano entro questi limiti.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"h-air-quality-management\"><strong>Gestione della qualità dell&#039;aria<\/strong><\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Utilizzo <strong>scrubber<\/strong> O <strong>filtri chimici<\/strong> rimuovere <strong>gas ETO<\/strong> dall’aria esausta prima di rilasciarla nell’atmosfera. Ciò aiuta a ridurre al minimo l’impatto ambientale e a mantenere sicura la qualità dell’aria.<\/p>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"h-8-emergency-response-and-first-aid-for-eto-exposure\"><strong>8. Risposta alle emergenze e primo soccorso per l&#039;esposizione a ETO<\/strong><\/h2>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"h-spill-containment-procedures\"><strong>Procedure di contenimento delle fuoriuscite<\/strong><\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Creare procedure chiare per la gestione <strong>Fuga di gas ETO<\/strong> o sversamenti. Assicurarsi che solo personale qualificato esegua le operazioni di pulizia e che l&#039;ambiente sia protetto dalla contaminazione.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"h-first-aid-measures\"><strong>Misure di primo soccorso<\/strong><\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Il personale addestrato dovrebbe sapere come rispondere <strong>Esposizione all&#039;ETO<\/strong>:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong>Inalazione<\/strong>: Portare immediatamente la persona colpita all&#039;aria aperta e consultare un medico.<\/li>\n\n\n\n<li><strong>Contatto con la pelle<\/strong>: Lavare l&#039;area interessata con acqua e rimuovere gli indumenti contaminati. Se l&#039;irritazione persiste, richiedere assistenza medica.<\/li>\n<\/ul>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"h-fire-safety\"><strong>Sicurezza antincendio<\/strong><\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Da <strong>gas ETO<\/strong> è infiammabile, assicurarsi che gli estintori (in particolare <strong>Classe B<\/strong>) sono disponibili nelle aree in cui <strong>STERILIZZAZIONE ETO<\/strong> si verifica.<\/p>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"h-9-training-and-standard-operating-procedures-sops-for-eto-sterilization\"><strong>9. Formazione e procedure operative standard (SOP) per la STERILIZZAZIONE ETO<\/strong><\/h2>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"h-operator-training\"><strong>Formazione degli operatori<\/strong><\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Tutti gli operatori devono essere sottoposti ad una formazione approfondita sul corretto utilizzo <strong>STERILIZZAZIONE ETO<\/strong> sistemi, compresa la movimentazione <strong>gas ETO<\/strong>, monitorandone la concentrazione e utilizzando i DPI.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"h-standard-operating-procedures-sops\"><strong>Procedure operative standard (SOP)<\/strong><\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Stabilire e seguire POS complete che coprano l&#039;intero <strong>STERILIZZAZIONE ETO<\/strong> process\u2014from setup and operation to maintenance and emergency response. These SOPs should be reviewed and updated regularly.<\/p>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"h-10-environmental-and-waste-disposal-considerations-for-eto-sterilization\"><strong>10. Considerazioni ambientali e sullo smaltimento dei rifiuti per la STERILIZZAZIONE ETO<\/strong><\/h2>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"h-environmental-protection\"><strong>Protezione ambientale<\/strong><\/h3>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>STERILIZZAZIONE ETO<\/strong> ha un impatto ambientale significativo a causa dei gas serra coinvolti. Utilizzo <strong>scrubber<\/strong> e altri sistemi di gestione del gas per prevenire il rilascio di <strong>ALLINEAMENTO<\/strong> nell&#039;atmosfera.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"h-disposal-of-eto-residues\"><strong>Smaltimento dei residui di ETO<\/strong><\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Smaltire <strong>L&#039;ETO rimane<\/strong> utilizzando <strong>incenerimento<\/strong> O <strong>sistemi di recupero gas<\/strong> per garantire uno smaltimento sicuro e rispettoso dell’ambiente.<\/p>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"h-conclusion\"><strong>Conclusione<\/strong><\/h3>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>STERILIZZAZIONE ETO<\/strong> è un metodo efficace per sterilizzare dispositivi medici e prodotti farmaceutici, ma comporta rischi intrinseci per la sicurezza. Per garantire un funzionamento sicuro, è fondamentale seguire rigorose linee guida di sicurezza tra cui un&#039;adeguata ventilazione, rilevamento del gas, dispositivi di protezione individuale (DPI) e procedure di risposta alle emergenze. La formazione regolare, il rispetto degli standard normativi e l&#039;uso delle migliori pratiche possono ridurre notevolmente i rischi e proteggere sia gli operatori che l&#039;ambiente.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Aderendo a queste linee guida di sicurezza, <strong>STERILIZZAZIONE ETO<\/strong> può continuare a essere un metodo sicuro ed efficace per la sterilizzazione in un&#039;ampia gamma di settori.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"h-if-you-want-to-know-more\">Se vuoi saperne di più<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Telefono:<a href=\"https:\/\/wa.me\/8619975258603\">+8619975258603<\/a><\/p>\n\n\n\n<p class=\"wp-block-paragraph\">E-mail:<a href=\"mailto:hayley@hzbocon.com\">hayley@hzbocon.com<\/a><\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Sito locale: Stanza 1202, Caitong Zhongxin, distretto di Xiasha, città di Hangzhou, provincia di Zhejiang, Cina<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Sito web:<a href=\"https:\/\/www.hzbocon.com\/\">hzbocon.com<\/a><a href=\"https:\/\/zjbocon.com\/\">zjbocon.com<\/a><\/p>\n","protected":false},"excerpt":{"rendered":"<p>Ethylene oxide (ETO STERILIZATION) is widely used as a low-temperature sterilant in industries like healthcare, pharmaceuticals, and biotechnology. However, due [&hellip;&quot;<\/p>\n","protected":false},"author":234312599,"featured_media":8783,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_uag_custom_page_level_css":"","site-sidebar-layout":"default","site-content-layout":"","ast-site-content-layout":"default","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","ast-disable-related-posts":"","theme-transparent-header-meta":"","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"default","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"_jetpack_newsletter_access":"","_jetpack_dont_email_post_to_subs":false,"_jetpack_newsletter_tier_id":0,"_jetpack_memberships_contains_paywalled_content":false,"_jetpack_feature_clip_id":0,"_jetpack_memberships_contains_paid_content":false,"footnotes":"","jetpack_publicize_message":"","jetpack_publicize_feature_enabled":true,"jetpack_social_post_already_shared":false,"jetpack_social_options":{"image_generator_settings":{"template":"highway","default_image_id":0,"font":"","enabled":false},"version":2},"jetpack_post_was_ever_published":false},"categories":[133125,133124],"tags":[],"class_list":["post-8772","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-company-news","category-eto-sterilizer"],"yoast_head":"<!-- This site is optimized with the Yoast SEO Premium plugin v27.2 (Yoast SEO v28.0) - https:\/\/yoast.com\/product\/yoast-seo-premium-wordpress\/ -->\n<title>ETO STERILIZZAZIONE Linee guida di sicurezza: migliori pratiche per l&#039;utilizzo dell&#039;ossido di etilene come sterilizzante - ETO STERILIZER<\/title>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \>\n<link rel=\"canonical\" href=\"https:\/\/zjbocon.com\/?p=8772\" \>\n<meta property=\"og:locale\" content=\"it_IT\" \>\n<meta property=\"og:type\" content=\"article\" \>\n<meta property=\"og:title\" content=\"ETO STERILIZATION Safety Guidelines: Best Practices for Using Ethylene Oxide as a Sterilant\" \>\n<meta property=\"og:description\" content=\"Ethylene oxide (ETO STERILIZATION) is widely used as a low-temperature sterilant in industries like healthcare, pharmaceuticals, and biotechnology. However, due [&hellip;]\" \>\n<meta property=\"og:url\" content=\"https:\/\/zjbocon.com\/?p=8772\" \>\n<meta property=\"og:site_name\" content=\"ETO STERILIZER\" \>\n<meta property=\"article:publisher\" content=\"https:\/\/www.facebook.com\/profile.php?id=100088482339878\" \>\n<meta property=\"article:author\" content=\"https:\/\/www.facebook.com\/profile.php?id=100088482339878\" \>\n<meta property=\"article:published_time\" content=\"2025-11-25T01:50:58+00:00\" \>\n<meta property=\"article:modified_time\" content=\"2025-11-25T10:11:09+00:00\" \>\n<meta property=\"og:image\" content=\"https:\/\/zjbocon.com\/wp-content\/uploads\/2025\/11\/eto-sterilzer-scaled.webp\" \>\n\t<meta property=\"og:image:width\" content=\"2560\" \>\n\t<meta property=\"og:image:height\" content=\"1129\" \>\n\t<meta property=\"og:image:type\" content=\"image\/webp\" \>\n<meta name=\"author\" content=\"Bocon Technical Team\" \>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \>\n<meta name=\"twitter:creator\" content=\"@BoconAnd\" \>\n<meta name=\"twitter:site\" content=\"@BoconAnd\" \>\n<meta name=\"twitter:label1\" content=\"Written by\" \>\n\t<meta name=\"twitter:data1\" content=\"Bocon Technical Team\" \>\n\t<meta name=\"twitter:label2\" content=\"Est. reading time\" \>\n\t<meta name=\"twitter:data2\" content=\"5 minutes\" \>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\\\/\\\/zjbocon.com\\\/?p=8772#article\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/zjbocon.com\\\/?p=8772\"},\"author\":{\"name\":\"Bocon Technical Team\",\"@id\":\"https:\\\/\\\/zjbocon.com\\\/#\\\/schema\\\/person\\\/f12be028b8ae9843a4396dcc8012b425\"},\"headline\":\"ETO STERILIZATION Safety Guidelines: Best Practices for Using Ethylene Oxide as a Sterilant\",\"datePublished\":\"2025-11-25T01:50:58+00:00\",\"dateModified\":\"2025-11-25T10:11:09+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/zjbocon.com\\\/?p=8772\"},\"wordCount\":948,\"commentCount\":0,\"publisher\":{\"@id\":\"https:\\\/\\\/zjbocon.com\\\/#organization\"},\"image\":{\"@id\":\"https:\\\/\\\/zjbocon.com\\\/?p=8772#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/zjbocon.com\\\/wp-content\\\/uploads\\\/2025\\\/11\\\/eto-sterilzer-scaled.webp\",\"articleSection\":[\"Company News\",\"ETO STERILIZER\"],\"inLanguage\":\"it-IT\",\"potentialAction\":[{\"@type\":\"CommentAction\",\"name\":\"Comment\",\"target\":[\"https:\\\/\\\/zjbocon.com\\\/?p=8772#respond\"]}]},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/zjbocon.com\\\/?p=8772\",\"url\":\"https:\\\/\\\/zjbocon.com\\\/?p=8772\",\"name\":\"ETO STERILIZATION Safety Guidelines: Best Practices for Using Ethylene Oxide as a Sterilant - ETO STERILIZER\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/zjbocon.com\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/zjbocon.com\\\/?p=8772#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/zjbocon.com\\\/?p=8772#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/zjbocon.com\\\/wp-content\\\/uploads\\\/2025\\\/11\\\/eto-sterilzer-scaled.webp\",\"datePublished\":\"2025-11-25T01:50:58+00:00\",\"dateModified\":\"2025-11-25T10:11:09+00:00\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/zjbocon.com\\\/?p=8772#breadcrumb\"},\"inLanguage\":\"it-IT\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/zjbocon.com\\\/?p=8772\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"it-IT\",\"@id\":\"https:\\\/\\\/zjbocon.com\\\/?p=8772#primaryimage\",\"url\":\"https:\\\/\\\/zjbocon.com\\\/wp-content\\\/uploads\\\/2025\\\/11\\\/eto-sterilzer-scaled.webp\",\"contentUrl\":\"https:\\\/\\\/zjbocon.com\\\/wp-content\\\/uploads\\\/2025\\\/11\\\/eto-sterilzer-scaled.webp\",\"width\":2560,\"height\":1129},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/zjbocon.com\\\/?p=8772#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/zjbocon.com\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"ETO STERILIZATION Safety Guidelines: Best Practices for Using Ethylene Oxide as a Sterilant\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/zjbocon.com\\\/#website\",\"url\":\"https:\\\/\\\/zjbocon.com\\\/\",\"name\":\"ETO STERILIZER\",\"description\":\"One-stop Solution Supplier of Ethylene Oxide Sterilization\",\"publisher\":{\"@id\":\"https:\\\/\\\/zjbocon.com\\\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/zjbocon.com\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"it-IT\"},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/zjbocon.com\\\/#organization\",\"name\":\"ETO STERILIZER\",\"url\":\"https:\\\/\\\/zjbocon.com\\\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"it-IT\",\"@id\":\"https:\\\/\\\/zjbocon.com\\\/#\\\/schema\\\/logo\\\/image\\\/\",\"url\":\"https:\\\/\\\/zjbocon.com\\\/wp-content\\\/uploads\\\/2024\\\/10\\\/logo-1.webp\",\"contentUrl\":\"https:\\\/\\\/zjbocon.com\\\/wp-content\\\/uploads\\\/2024\\\/10\\\/logo-1.webp\",\"width\":180,\"height\":60,\"caption\":\"ETO STERILIZER\"},\"image\":{\"@id\":\"https:\\\/\\\/zjbocon.com\\\/#\\\/schema\\\/logo\\\/image\\\/\"},\"sameAs\":[\"https:\\\/\\\/www.facebook.com\\\/profile.php?id=100088482339878\",\"https:\\\/\\\/x.com\\\/BoconAnd\",\"https:\\\/\\\/www.linkedin.com\\\/in\\\/--06a221139\\\/\"]},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/zjbocon.com\\\/#\\\/schema\\\/person\\\/f12be028b8ae9843a4396dcc8012b425\",\"name\":\"Bocon Technical Team\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"it-IT\",\"@id\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/d7a825658be227f26b237e519f8541e05aabc9ff27b8eec4544a233a48c53be0?s=96&d=identicon&r=g\",\"url\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/d7a825658be227f26b237e519f8541e05aabc9ff27b8eec4544a233a48c53be0?s=96&d=identicon&r=g\",\"contentUrl\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/d7a825658be227f26b237e519f8541e05aabc9ff27b8eec4544a233a48c53be0?s=96&d=identicon&r=g\",\"caption\":\"Bocon Technical Team\"},\"sameAs\":[\"https:\\\/\\\/zjbocon.com\\\/\",\"https:\\\/\\\/www.facebook.com\\\/profile.php?id=100088482339878\",\"https:\\\/\\\/www.linkedin.com\\\/in\\\/\\\/hayley--968190269\\\/\"],\"url\":\"https:\\\/\\\/zjbocon.com\\\/?author=234312599\"}]}<\/script>\n<!-- \/ Yoast SEO Premium plugin. -->","yoast_head_json":{"title":"ETO STERILIZATION Safety Guidelines: Best Practices for Using Ethylene Oxide as a Sterilant - ETO STERILIZER","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/zjbocon.com\/?p=8772","og_locale":"it_IT","og_type":"article","og_title":"ETO STERILIZATION Safety Guidelines: Best Practices for Using Ethylene Oxide as a Sterilant","og_description":"Ethylene oxide (ETO STERILIZATION) is widely used as a low-temperature sterilant in industries like healthcare, pharmaceuticals, and biotechnology. However, due [&hellip;]","og_url":"https:\/\/zjbocon.com\/?p=8772","og_site_name":"ETO STERILIZER","article_publisher":"https:\/\/www.facebook.com\/profile.php?id=100088482339878","article_author":"https:\/\/www.facebook.com\/profile.php?id=100088482339878","article_published_time":"2025-11-25T01:50:58+00:00","article_modified_time":"2025-11-25T10:11:09+00:00","og_image":[{"width":2560,"height":1129,"url":"https:\/\/zjbocon.com\/wp-content\/uploads\/2025\/11\/eto-sterilzer-scaled.webp","type":"image\/webp"}],"author":"Bocon Technical Team","twitter_card":"summary_large_image","twitter_creator":"@BoconAnd","twitter_site":"@BoconAnd","twitter_misc":{"Written by":"Bocon Technical Team","Est. reading time":"5 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/zjbocon.com\/?p=8772#article","isPartOf":{"@id":"https:\/\/zjbocon.com\/?p=8772"},"author":{"name":"Bocon Technical Team","@id":"https:\/\/zjbocon.com\/#\/schema\/person\/f12be028b8ae9843a4396dcc8012b425"},"headline":"ETO STERILIZATION Safety Guidelines: Best Practices for Using Ethylene Oxide as a Sterilant","datePublished":"2025-11-25T01:50:58+00:00","dateModified":"2025-11-25T10:11:09+00:00","mainEntityOfPage":{"@id":"https:\/\/zjbocon.com\/?p=8772"},"wordCount":948,"commentCount":0,"publisher":{"@id":"https:\/\/zjbocon.com\/#organization"},"image":{"@id":"https:\/\/zjbocon.com\/?p=8772#primaryimage"},"thumbnailUrl":"https:\/\/zjbocon.com\/wp-content\/uploads\/2025\/11\/eto-sterilzer-scaled.webp","articleSection":["Company News","ETO STERILIZER"],"inLanguage":"it-IT","potentialAction":[{"@type":"CommentAction","name":"Comment","target":["https:\/\/zjbocon.com\/?p=8772#respond"]}]},{"@type":"WebPage","@id":"https:\/\/zjbocon.com\/?p=8772","url":"https:\/\/zjbocon.com\/?p=8772","name":"ETO STERILIZATION Safety Guidelines: Best Practices for Using Ethylene Oxide as a Sterilant - ETO STERILIZER","isPartOf":{"@id":"https:\/\/zjbocon.com\/#website"},"primaryImageOfPage":{"@id":"https:\/\/zjbocon.com\/?p=8772#primaryimage"},"image":{"@id":"https:\/\/zjbocon.com\/?p=8772#primaryimage"},"thumbnailUrl":"https:\/\/zjbocon.com\/wp-content\/uploads\/2025\/11\/eto-sterilzer-scaled.webp","datePublished":"2025-11-25T01:50:58+00:00","dateModified":"2025-11-25T10:11:09+00:00","breadcrumb":{"@id":"https:\/\/zjbocon.com\/?p=8772#breadcrumb"},"inLanguage":"it-IT","potentialAction":[{"@type":"ReadAction","target":["https:\/\/zjbocon.com\/?p=8772"]}]},{"@type":"ImageObject","inLanguage":"it-IT","@id":"https:\/\/zjbocon.com\/?p=8772#primaryimage","url":"https:\/\/zjbocon.com\/wp-content\/uploads\/2025\/11\/eto-sterilzer-scaled.webp","contentUrl":"https:\/\/zjbocon.com\/wp-content\/uploads\/2025\/11\/eto-sterilzer-scaled.webp","width":2560,"height":1129},{"@type":"BreadcrumbList","@id":"https:\/\/zjbocon.com\/?p=8772#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/zjbocon.com\/"},{"@type":"ListItem","position":2,"name":"ETO STERILIZATION Safety Guidelines: Best Practices for Using Ethylene Oxide as a Sterilant"}]},{"@type":"WebSite","@id":"https:\/\/zjbocon.com\/#website","url":"https:\/\/zjbocon.com\/","name":"ETO STERILIZER","description":"One-stop Solution Supplier of Ethylene Oxide Sterilization","publisher":{"@id":"https:\/\/zjbocon.com\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/zjbocon.com\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"it-IT"},{"@type":"Organization","@id":"https:\/\/zjbocon.com\/#organization","name":"ETO STERILIZER","url":"https:\/\/zjbocon.com\/","logo":{"@type":"ImageObject","inLanguage":"it-IT","@id":"https:\/\/zjbocon.com\/#\/schema\/logo\/image\/","url":"https:\/\/zjbocon.com\/wp-content\/uploads\/2024\/10\/logo-1.webp","contentUrl":"https:\/\/zjbocon.com\/wp-content\/uploads\/2024\/10\/logo-1.webp","width":180,"height":60,"caption":"ETO STERILIZER"},"image":{"@id":"https:\/\/zjbocon.com\/#\/schema\/logo\/image\/"},"sameAs":["https:\/\/www.facebook.com\/profile.php?id=100088482339878","https:\/\/x.com\/BoconAnd","https:\/\/www.linkedin.com\/in\/--06a221139\/"]},{"@type":"Person","@id":"https:\/\/zjbocon.com\/#\/schema\/person\/f12be028b8ae9843a4396dcc8012b425","name":"Bocon Technical Team","image":{"@type":"ImageObject","inLanguage":"it-IT","@id":"https:\/\/secure.gravatar.com\/avatar\/d7a825658be227f26b237e519f8541e05aabc9ff27b8eec4544a233a48c53be0?s=96&d=identicon&r=g","url":"https:\/\/secure.gravatar.com\/avatar\/d7a825658be227f26b237e519f8541e05aabc9ff27b8eec4544a233a48c53be0?s=96&d=identicon&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/d7a825658be227f26b237e519f8541e05aabc9ff27b8eec4544a233a48c53be0?s=96&d=identicon&r=g","caption":"Bocon Technical Team"},"sameAs":["https:\/\/zjbocon.com\/","https:\/\/www.facebook.com\/profile.php?id=100088482339878","https:\/\/www.linkedin.com\/in\/\/hayley--968190269\/"],"url":"https:\/\/zjbocon.com\/?author=234312599"}]}},"jetpack_publicize_connections":[],"jetpack_featured_media_url":"https:\/\/zjbocon.com\/wp-content\/uploads\/2025\/11\/eto-sterilzer-scaled.webp","uagb_featured_image_src":{"full":["https:\/\/zjbocon.com\/wp-content\/uploads\/2025\/11\/eto-sterilzer-scaled.webp",2560,1129,false],"thumbnail":["https:\/\/zjbocon.com\/wp-content\/uploads\/2025\/11\/eto-sterilzer-150x150.webp",150,150,true],"medium":["https:\/\/zjbocon.com\/wp-content\/uploads\/2025\/11\/eto-sterilzer-300x132.webp",300,132,true],"medium_large":["https:\/\/zjbocon.com\/wp-content\/uploads\/2025\/11\/eto-sterilzer-768x339.webp",768,339,true],"large":["https:\/\/zjbocon.com\/wp-content\/uploads\/2025\/11\/eto-sterilzer-1024x452.webp",1024,452,true],"1536x1536":["https:\/\/zjbocon.com\/wp-content\/uploads\/2025\/11\/eto-sterilzer-1536x677.webp",1536,677,true],"2048x2048":["https:\/\/zjbocon.com\/wp-content\/uploads\/2025\/11\/eto-sterilzer-2048x903.webp",2048,903,true],"woocommerce_thumbnail":["https:\/\/zjbocon.com\/wp-content\/uploads\/2025\/11\/eto-sterilzer-600x600.webp",600,600,true],"woocommerce_single":["https:\/\/zjbocon.com\/wp-content\/uploads\/2025\/11\/eto-sterilzer-600x265.webp",600,265,true],"woocommerce_gallery_thumbnail":["https:\/\/zjbocon.com\/wp-content\/uploads\/2025\/11\/eto-sterilzer-100x100.webp",100,100,true]},"uagb_author_info":{"display_name":"Bocon Technical Team","author_link":"https:\/\/zjbocon.com\/?author=234312599"},"uagb_comment_info":0,"uagb_excerpt":"Ethylene oxide (ETO STERILIZATION) is widely used as a low-temperature sterilant in industries like healthcare, pharmaceuticals, and biotechnology. However, due [&hellip;]","jetpack_likes_enabled":true,"jetpack_sharing_enabled":true,"jetpack_shortlink":"https:\/\/wp.me\/pgZDV6-2hu","jetpack-related-posts":[{"id":2471,"url":"https:\/\/zjbocon.com\/?p=2471","url_meta":{"origin":8772,"position":0},"title":"Safety Requirements for Using Ethylene Oxide in sterilization","author":"Bocon Technical Team","date":"2024-12-23","format":false,"excerpt":"when Ethylene Oxide in sterilization chamber should be equipped with fire prevention facilities. Ethylene oxide cylinders should be stored separately in a dry, well-ventilated room, with strict prohibition of smoking and open flames. The lighting in the sterilization chamber should be explosion-proof, and any electrical appliances that may cause electric\u2026","rel":"","context":"In &quot;Company News&quot;","block_context":{"text":"Company News","link":"https:\/\/zjbocon.com\/?cat=133125"},"img":{"alt_text":"","src":"https:\/\/i0.wp.com\/zjbocon.com\/wp-content\/uploads\/2024\/10\/Electrical-Scale.png?resize=350%2C200","width":350,"height":200},"classes":[]},{"id":8958,"url":"https:\/\/zjbocon.com\/?p=8958","url_meta":{"origin":8772,"position":1},"title":"Understanding What is ETO Sterilizers: A Comprehensive Guide","author":"Bocon Technical Team","date":"2025-12-16","format":false,"excerpt":"Discover the essentials of ETO sterilizers and ethylene oxide sterilization, ensuring the highest hygiene standards in healthcare and beyond.","rel":"","context":"In &quot;Company News&quot;","block_context":{"text":"Company News","link":"https:\/\/zjbocon.com\/?cat=133125"},"img":{"alt_text":"","src":"https:\/\/i0.wp.com\/zjbocon.com\/wp-content\/uploads\/2024\/11\/eto-sterilizer-hzbocon-3.png?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/zjbocon.com\/wp-content\/uploads\/2024\/11\/eto-sterilizer-hzbocon-3.png?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/zjbocon.com\/wp-content\/uploads\/2024\/11\/eto-sterilizer-hzbocon-3.png?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/zjbocon.com\/wp-content\/uploads\/2024\/11\/eto-sterilizer-hzbocon-3.png?resize=700%2C400&ssl=1 2x, https:\/\/i0.wp.com\/zjbocon.com\/wp-content\/uploads\/2024\/11\/eto-sterilizer-hzbocon-3.png?resize=1050%2C600&ssl=1 3x"},"classes":[]},{"id":3093,"url":"https:\/\/zjbocon.com\/?p=3093","url_meta":{"origin":8772,"position":2},"title":"Introduction to Ethylene Oxide Sterilizers","author":"Bocon Technical Team","date":"2025-02-05","format":false,"excerpt":"Discover how ethylene oxide sterilizers work, their applications, benefits, and safety considerations. Learn why they are essential for medical and industrial sterilization.","rel":"","context":"In &quot;Company News&quot;","block_context":{"text":"Company News","link":"https:\/\/zjbocon.com\/?cat=133125"},"img":{"alt_text":"","src":"https:\/\/i0.wp.com\/zjbocon.com\/wp-content\/uploads\/2024\/11\/ethylene-oxide-sterilization-21.webp?resize=350%2C200","width":350,"height":200},"classes":[]},{"id":2476,"url":"https:\/\/zjbocon.com\/?p=2476","url_meta":{"origin":8772,"position":3},"title":"Ethylene Oxide Leak Handling when using eto sterilizer","author":"Bocon Technical Team","date":"2024-12-23","format":false,"excerpt":"If a leak is detected in the eto sterilizer dosing pipeline during the administration process, immediately close the medication bottle, switch and the dosing valve on the main unit. Turn on the axial fan to ensure proper ventilation, and then proceed with repairs.","rel":"","context":"In &quot;Company News&quot;","block_context":{"text":"Company News","link":"https:\/\/zjbocon.com\/?cat=133125"},"img":{"alt_text":"","src":"https:\/\/i0.wp.com\/zjbocon.com\/wp-content\/uploads\/2025\/09\/ethylene-oxide-sterilization-19-scaled.webp?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/zjbocon.com\/wp-content\/uploads\/2025\/09\/ethylene-oxide-sterilization-19-scaled.webp?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/zjbocon.com\/wp-content\/uploads\/2025\/09\/ethylene-oxide-sterilization-19-scaled.webp?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/zjbocon.com\/wp-content\/uploads\/2025\/09\/ethylene-oxide-sterilization-19-scaled.webp?resize=700%2C400&ssl=1 2x, https:\/\/i0.wp.com\/zjbocon.com\/wp-content\/uploads\/2025\/09\/ethylene-oxide-sterilization-19-scaled.webp?resize=1050%2C600&ssl=1 3x, https:\/\/i0.wp.com\/zjbocon.com\/wp-content\/uploads\/2025\/09\/ethylene-oxide-sterilization-19-scaled.webp?resize=1400%2C800&ssl=1 4x"},"classes":[]},{"id":9080,"url":"https:\/\/zjbocon.com\/?p=9080","url_meta":{"origin":8772,"position":4},"title":"Essential Utilities and Service Requirements for ETO Sterilizers","author":"Bocon Technical Team","date":"2026-01-20","format":false,"excerpt":"The successful operation of an Ethylene Oxide (ETO) sterilizer requires more than just the machine itself; it demands a robust infrastructure of essential utilities, safety systems, and ongoing technical support. Ensuring these requirements are met is critical for process efficiency, operator safety, and regulatory compliance (such as ISO 11135). Below\u2026","rel":"","context":"In &quot;Company News&quot;","block_context":{"text":"Company News","link":"https:\/\/zjbocon.com\/?cat=133125"},"img":{"alt_text":"","src":"https:\/\/i0.wp.com\/zjbocon.com\/wp-content\/uploads\/2024\/11\/eto-sterilizer-hzbocon-4.png?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/zjbocon.com\/wp-content\/uploads\/2024\/11\/eto-sterilizer-hzbocon-4.png?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/zjbocon.com\/wp-content\/uploads\/2024\/11\/eto-sterilizer-hzbocon-4.png?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/zjbocon.com\/wp-content\/uploads\/2024\/11\/eto-sterilizer-hzbocon-4.png?resize=700%2C400&ssl=1 2x, https:\/\/i0.wp.com\/zjbocon.com\/wp-content\/uploads\/2024\/11\/eto-sterilizer-hzbocon-4.png?resize=1050%2C600&ssl=1 3x"},"classes":[]},{"id":2453,"url":"https:\/\/zjbocon.com\/?p=2453","url_meta":{"origin":8772,"position":5},"title":"Microbial Killing Performance of Ethylene Oxide Sterilizers","author":"Bocon Technical Team","date":"2024-12-20","format":false,"excerpt":"Note 1: The Ethylene Oxide sterilization conditions must be obtained through validation confirmation and should be verified with monitoring and routine control during each sterilization cycle. The requirements for validation and routine control are outlined in GB 18279. Note 2: This testing method is also applicable to A class Ethylene\u2026","rel":"","context":"In &quot;Company News&quot;","block_context":{"text":"Company News","link":"https:\/\/zjbocon.com\/?cat=133125"},"img":{"alt_text":"eto sterilizer","src":"https:\/\/i0.wp.com\/zjbocon.com\/wp-content\/uploads\/2024\/10\/banner__.webp?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/zjbocon.com\/wp-content\/uploads\/2024\/10\/banner__.webp?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/zjbocon.com\/wp-content\/uploads\/2024\/10\/banner__.webp?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/zjbocon.com\/wp-content\/uploads\/2024\/10\/banner__.webp?resize=700%2C400&ssl=1 2x"},"classes":[]}],"_links":{"self":[{"href":"https:\/\/zjbocon.com\/index.php?rest_route=\/wp\/v2\/posts\/8772","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/zjbocon.com\/index.php?rest_route=\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/zjbocon.com\/index.php?rest_route=\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/zjbocon.com\/index.php?rest_route=\/wp\/v2\/users\/234312599"}],"replies":[{"embeddable":true,"href":"https:\/\/zjbocon.com\/index.php?rest_route=%2Fwp%2Fv2%2Fcomments&post=8772"}],"version-history":[{"count":3,"href":"https:\/\/zjbocon.com\/index.php?rest_route=\/wp\/v2\/posts\/8772\/revisions"}],"predecessor-version":[{"id":8775,"href":"https:\/\/zjbocon.com\/index.php?rest_route=\/wp\/v2\/posts\/8772\/revisions\/8775"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/zjbocon.com\/index.php?rest_route=\/wp\/v2\/media\/8783"}],"wp:attachment":[{"href":"https:\/\/zjbocon.com\/index.php?rest_route=%2Fwp%2Fv2%2Fmedia&parent=8772"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/zjbocon.com\/index.php?rest_route=%2Fwp%2Fv2%2Fcategories&post=8772"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/zjbocon.com\/index.php?rest_route=%2Fwp%2Fv2%2Ftags&post=8772"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}