{"id":2492,"date":"2024-12-24T10:37:05","date_gmt":"2024-12-24T02:37:05","guid":{"rendered":"https:\/\/zjbocon.com\/?p=2492"},"modified":"2025-12-05T09:43:37","modified_gmt":"2025-12-05T01:43:37","slug":"understanding-eto-sterilizer-performance-keys-to-efficiency","status":"publish","type":"post","link":"https:\/\/zjbocon.com\/?p=2492","title":{"rendered":"Understanding ETO Sterilizer Performance: Keys to Efficiency"},"content":{"rendered":"\n<div class=\"wp-block-uagb-image uagb-block-9ab8250e wp-block-uagb-image--layout-default wp-block-uagb-image--effect-static wp-block-uagb-image--align-none\"><figure class=\"wp-block-uagb-image__figure\"><img loading=\"lazy\" decoding=\"async\" src=\"https:\/\/zjbocon.com\/wp-content\/uploads\/2025\/11\/eto-sterilzer-1024x452.webp\" alt=\"\" class=\"uag-image-8783\" width=\"1024\" height=\"452\" title=\"eto sterilzer\" role=\"img\" \><\/figure><\/div>\n\n\n\n<p class=\"wp-block-paragraph\"><br>3.4.1 eto滅菌機の温度設定範囲<br>The temperature setting range for the eto sterilizer is: 30 to 70\u00b0C, with a control error of ?2\u00b0C.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">3.4.2 エチレンオキシド装置の温度均一性<br>eto 滅菌器の温度均一性は、次の要件を満たす必要があります。<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">When the volume of the sterilization chamber is ?5m\u00b3, at least 10 measurement points must be placed.<br>ボリュームが &gt;5m\u00b3, for every additional 1m\u00b3, one more measurement point should be added.<br>When the volume is ?10m\u00b3, at least 20 measurement points must be set inside the chamber, with the test temperature ?40\u00b0C, and the temperature difference between each measurement point must not exceed \u00b13\u00b0C.<br>3.4.3 滅菌チャンバーの漏れ率<br>3.4.3.1<br>テストは、滅菌剤の注入段階および加湿段階（挿入された温度および圧力表示装置を使用する場合）の前に実施する必要があります。圧力は製造業者によって事前設定される必要があり、テスト圧力は -20 kPa 未満で、事前設定された滅菌圧力より少なくとも 20 kPa 低くなければなりません。<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">3.4.3.2<br>If the pressure during any stage of the sterilization cycle is below atmospheric pressure, after reaching the preset pressure, all valves connected to the sterilization chamber should be closed, and the vacuum pump should stop working. The pressure in the sterilization chamber should be monitored for at least 5 minutes, during which the pressure rise must not exceed 0.3 kPa\/min.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">3.4.3.3<br>When the working pressure of the eo chamber is greater than 5 kPa, a positive pressure leakage test should also be conducted, which should be performed before the vacuum stage. By pressurizing with inert gas (such as air) to within 10% of the preset working pressure, the pressure in the sterilization chamber should be monitored for at least 5 minutes, during which the pressure drop must not exceed 0.3 kPa\/min.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">3.4.4 eto滅菌機の真空速度<br>無負荷条件下では、eo チャンバーは 6 分以内に大気圧から -15 kPa に達します。 30 分以内に -50 kPa に達します。 ?40 分で -75 kPa に達します。<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">3.4.5 eto滅菌器の加湿効果<br>無負荷条件下で相対湿度が 40% RH 以下の場合、eo 滅菌機は加湿システムを通じて相対湿度を少なくとも 75% 以上に高める機能を備えている必要があります。<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">3.4.6 滅菌室の圧力設定範囲<br>滅菌室の圧力設定範囲は-0.08MPa～+0.08MPaです。<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">3.4.7 eto 滅菌機の最大騒音レベル<br>eto 滅菌チャンバーによって生成される最大騒音レベル (A-weighted) は、?65 dB である必要があります。<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">3.4.8 エチレンオキシド滅菌器の外観と構造<br>3.4.8.1<br>形状は直立しており、表面が滑らかできれいで、色が均一で、バリ、鋭いエッジ、亀裂がないことが必要です。明らかな傷や凹凸などの欠陥がないこと。<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">3.4.8.2<br>表面上のすべてのテキスト、グラフィック、記号などは、鮮明で正確かつ耐久性のあるマーキングで鮮明に印刷する必要があります。<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">3.4.8.3<br>ファスナーはしっかりと取り付けられ、すべてのコントロールスイッチと調整ノブ（ボタン）が障害なく柔軟かつ確実に動作する必要があります。<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">接触<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">電話：<a href=\"https:\/\/wa.me\/8619975258603\">+8619975258603<\/a><\/p>\n\n\n\n<p class=\"wp-block-paragraph\">電子メール:<a href=\"mailto:hayley@hzbocon.com\">ヘイリー@hzbocon.com<\/a><\/p>\n\n\n\n<p class=\"wp-block-paragraph\">ローカルサイト: 中国浙江省杭州市下沙区財通中新1202号室<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Webサイト：<a href=\"https:\/\/www.hzbocon.com\/\">hzbocon.com<\/a><a href=\"https:\/\/zjbocon.com\/\">&nbsp;zjbocon.com<\/a><\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><\/p>\n","protected":false},"excerpt":{"rendered":"<p>3.4.1 eto滅菌機の温度設定範囲<br \>\nThe temperature setting range for the eto sterilizer is: 30 to 70\u00b0C<\/p>\n","protected":false},"author":234312599,"featured_media":8489,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_uag_custom_page_level_css":"","site-sidebar-layout":"default","site-content-layout":"","ast-site-content-layout":"default","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","ast-disable-related-posts":"","theme-transparent-header-meta":"","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"set","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"_jetpack_newsletter_access":"","_jetpack_dont_email_post_to_subs":false,"_jetpack_newsletter_tier_id":0,"_jetpack_memberships_contains_paywalled_content":false,"_jetpack_feature_clip_id":0,"_jetpack_memberships_contains_paid_content":false,"footnotes":"","jetpack_publicize_message":"","jetpack_publicize_feature_enabled":true,"jetpack_social_post_already_shared":true,"jetpack_social_options":{"image_generator_settings":{"template":"highway","enabled":false},"version":2},"jetpack_post_was_ever_published":false},"categories":[133125,133124],"tags":[],"class_list":["post-2492","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-company-news","category-eto-sterilizer"],"yoast_head":"<!-- This site is optimized with the Yoast SEO Premium plugin v27.2 (Yoast SEO v28.0) - https:\/\/yoast.com\/product\/yoast-seo-premium-wordpress\/ -->\n<title>ETO 滅菌器の性能を理解する: 効率の鍵 - ETO STERILIZER<\/title>\n<meta name=\"description\" content=\"3.4.1 eto sterilizer machine Temperature Setting RangeThe temperature setting range for the is: 30 to 70\u00b0C,\" \>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \>\n<link rel=\"canonical\" href=\"https:\/\/zjbocon.com\/?p=2492\" \>\n<meta property=\"og:locale\" content=\"ja_JP\" \>\n<meta property=\"og:type\" content=\"article\" \>\n<meta property=\"og:title\" content=\"Understanding ETO Sterilizer Performance: Keys to Efficiency\" \>\n<meta property=\"og:description\" content=\"3.4.1 eto sterilizer machine Temperature Setting RangeThe temperature setting range for the is: 30 to 70\u00b0C,\" \>\n<meta property=\"og:url\" content=\"https:\/\/zjbocon.com\/?p=2492\" \>\n<meta property=\"og:site_name\" content=\"ETO STERILIZER\" \>\n<meta property=\"article:publisher\" content=\"https:\/\/www.facebook.com\/profile.php?id=100088482339878\" \>\n<meta property=\"article:author\" content=\"https:\/\/www.facebook.com\/profile.php?id=100088482339878\" \>\n<meta property=\"article:published_time\" content=\"2024-12-24T02:37:05+00:00\" \>\n<meta property=\"article:modified_time\" content=\"2025-12-05T01:43:37+00:00\" \>\n<meta property=\"og:image\" content=\"https:\/\/zjbocon.com\/wp-content\/uploads\/2025\/09\/eto-sterilizer-1.webp\" \>\n\t<meta property=\"og:image:width\" content=\"1200\" \>\n\t<meta property=\"og:image:height\" content=\"1200\" \>\n\t<meta property=\"og:image:type\" content=\"image\/webp\" \>\n<meta name=\"author\" content=\"Bocon Technical Team\" \>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \>\n<meta name=\"twitter:creator\" content=\"@BoconAnd\" \>\n<meta name=\"twitter:site\" content=\"@BoconAnd\" \>\n<meta name=\"twitter:label1\" content=\"Written by\" \>\n\t<meta name=\"twitter:data1\" content=\"Bocon Technical Team\" \>\n\t<meta name=\"twitter:label2\" content=\"Est. reading time\" \>\n\t<meta name=\"twitter:data2\" content=\"3 minutes\" \>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\\\/\\\/zjbocon.com\\\/?p=2492#article\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/zjbocon.com\\\/?p=2492\"},\"author\":{\"name\":\"Bocon Technical Team\",\"@id\":\"https:\\\/\\\/zjbocon.com\\\/#\\\/schema\\\/person\\\/f12be028b8ae9843a4396dcc8012b425\"},\"headline\":\"Understanding ETO Sterilizer Performance: Keys to Efficiency\",\"datePublished\":\"2024-12-24T02:37:05+00:00\",\"dateModified\":\"2025-12-05T01:43:37+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/zjbocon.com\\\/?p=2492\"},\"wordCount\":510,\"commentCount\":0,\"publisher\":{\"@id\":\"https:\\\/\\\/zjbocon.com\\\/#organization\"},\"image\":{\"@id\":\"https:\\\/\\\/zjbocon.com\\\/?p=2492#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/zjbocon.com\\\/wp-content\\\/uploads\\\/2025\\\/09\\\/eto-sterilizer-1.webp\",\"articleSection\":[\"Company News\",\"ETO STERILIZER\"],\"inLanguage\":\"ja\",\"potentialAction\":[{\"@type\":\"CommentAction\",\"name\":\"Comment\",\"target\":[\"https:\\\/\\\/zjbocon.com\\\/?p=2492#respond\"]}]},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/zjbocon.com\\\/?p=2492\",\"url\":\"https:\\\/\\\/zjbocon.com\\\/?p=2492\",\"name\":\"Understanding ETO Sterilizer Performance: Keys to Efficiency - ETO STERILIZER\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/zjbocon.com\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/zjbocon.com\\\/?p=2492#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/zjbocon.com\\\/?p=2492#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/zjbocon.com\\\/wp-content\\\/uploads\\\/2025\\\/09\\\/eto-sterilizer-1.webp\",\"datePublished\":\"2024-12-24T02:37:05+00:00\",\"dateModified\":\"2025-12-05T01:43:37+00:00\",\"description\":\"3.4.1 eto sterilizer machine Temperature Setting RangeThe temperature setting range for the eto sterilizer is: 30 to 70\u00b0C,\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/zjbocon.com\\\/?p=2492#breadcrumb\"},\"inLanguage\":\"ja\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/zjbocon.com\\\/?p=2492\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"ja\",\"@id\":\"https:\\\/\\\/zjbocon.com\\\/?p=2492#primaryimage\",\"url\":\"https:\\\/\\\/zjbocon.com\\\/wp-content\\\/uploads\\\/2025\\\/09\\\/eto-sterilizer-1.webp\",\"contentUrl\":\"https:\\\/\\\/zjbocon.com\\\/wp-content\\\/uploads\\\/2025\\\/09\\\/eto-sterilizer-1.webp\",\"width\":1200,\"height\":1200},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/zjbocon.com\\\/?p=2492#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/zjbocon.com\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Understanding ETO Sterilizer Performance: Keys to Efficiency\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/zjbocon.com\\\/#website\",\"url\":\"https:\\\/\\\/zjbocon.com\\\/\",\"name\":\"ETO STERILIZER\",\"description\":\"One-stop Solution Supplier of Ethylene Oxide Sterilization\",\"publisher\":{\"@id\":\"https:\\\/\\\/zjbocon.com\\\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/zjbocon.com\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"ja\"},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/zjbocon.com\\\/#organization\",\"name\":\"ETO STERILIZER\",\"url\":\"https:\\\/\\\/zjbocon.com\\\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"ja\",\"@id\":\"https:\\\/\\\/zjbocon.com\\\/#\\\/schema\\\/logo\\\/image\\\/\",\"url\":\"https:\\\/\\\/zjbocon.com\\\/wp-content\\\/uploads\\\/2024\\\/10\\\/logo-1.webp\",\"contentUrl\":\"https:\\\/\\\/zjbocon.com\\\/wp-content\\\/uploads\\\/2024\\\/10\\\/logo-1.webp\",\"width\":180,\"height\":60,\"caption\":\"ETO STERILIZER\"},\"image\":{\"@id\":\"https:\\\/\\\/zjbocon.com\\\/#\\\/schema\\\/logo\\\/image\\\/\"},\"sameAs\":[\"https:\\\/\\\/www.facebook.com\\\/profile.php?id=100088482339878\",\"https:\\\/\\\/x.com\\\/BoconAnd\",\"https:\\\/\\\/www.linkedin.com\\\/in\\\/--06a221139\\\/\"]},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/zjbocon.com\\\/#\\\/schema\\\/person\\\/f12be028b8ae9843a4396dcc8012b425\",\"name\":\"Bocon Technical Team\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"ja\",\"@id\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/d7a825658be227f26b237e519f8541e05aabc9ff27b8eec4544a233a48c53be0?s=96&d=identicon&r=g\",\"url\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/d7a825658be227f26b237e519f8541e05aabc9ff27b8eec4544a233a48c53be0?s=96&d=identicon&r=g\",\"contentUrl\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/d7a825658be227f26b237e519f8541e05aabc9ff27b8eec4544a233a48c53be0?s=96&d=identicon&r=g\",\"caption\":\"Bocon Technical Team\"},\"sameAs\":[\"https:\\\/\\\/zjbocon.com\\\/\",\"https:\\\/\\\/www.facebook.com\\\/profile.php?id=100088482339878\",\"https:\\\/\\\/www.linkedin.com\\\/in\\\/\\\/hayley--968190269\\\/\"],\"url\":\"https:\\\/\\\/zjbocon.com\\\/?author=234312599\"}]}<\/script>\n<!-- \/ Yoast SEO Premium plugin. -->","yoast_head_json":{"title":"Understanding ETO Sterilizer Performance: Keys to Efficiency - ETO STERILIZER","description":"3.4.1 eto sterilizer machine Temperature Setting RangeThe temperature setting range for the eto sterilizer is: 30 to 70\u00b0C,","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/zjbocon.com\/?p=2492","og_locale":"ja_JP","og_type":"article","og_title":"Understanding ETO Sterilizer Performance: Keys to Efficiency","og_description":"3.4.1 eto sterilizer machine Temperature Setting RangeThe temperature setting range for the eto sterilizer is: 30 to 70\u00b0C,","og_url":"https:\/\/zjbocon.com\/?p=2492","og_site_name":"ETO STERILIZER","article_publisher":"https:\/\/www.facebook.com\/profile.php?id=100088482339878","article_author":"https:\/\/www.facebook.com\/profile.php?id=100088482339878","article_published_time":"2024-12-24T02:37:05+00:00","article_modified_time":"2025-12-05T01:43:37+00:00","og_image":[{"width":1200,"height":1200,"url":"https:\/\/zjbocon.com\/wp-content\/uploads\/2025\/09\/eto-sterilizer-1.webp","type":"image\/webp"}],"author":"Bocon Technical Team","twitter_card":"summary_large_image","twitter_creator":"@BoconAnd","twitter_site":"@BoconAnd","twitter_misc":{"Written by":"Bocon Technical Team","Est. reading time":"3 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/zjbocon.com\/?p=2492#article","isPartOf":{"@id":"https:\/\/zjbocon.com\/?p=2492"},"author":{"name":"Bocon Technical Team","@id":"https:\/\/zjbocon.com\/#\/schema\/person\/f12be028b8ae9843a4396dcc8012b425"},"headline":"Understanding ETO Sterilizer Performance: Keys to Efficiency","datePublished":"2024-12-24T02:37:05+00:00","dateModified":"2025-12-05T01:43:37+00:00","mainEntityOfPage":{"@id":"https:\/\/zjbocon.com\/?p=2492"},"wordCount":510,"commentCount":0,"publisher":{"@id":"https:\/\/zjbocon.com\/#organization"},"image":{"@id":"https:\/\/zjbocon.com\/?p=2492#primaryimage"},"thumbnailUrl":"https:\/\/zjbocon.com\/wp-content\/uploads\/2025\/09\/eto-sterilizer-1.webp","articleSection":["Company News","ETO STERILIZER"],"inLanguage":"ja","potentialAction":[{"@type":"CommentAction","name":"Comment","target":["https:\/\/zjbocon.com\/?p=2492#respond"]}]},{"@type":"WebPage","@id":"https:\/\/zjbocon.com\/?p=2492","url":"https:\/\/zjbocon.com\/?p=2492","name":"Understanding ETO Sterilizer Performance: Keys to Efficiency - ETO STERILIZER","isPartOf":{"@id":"https:\/\/zjbocon.com\/#website"},"primaryImageOfPage":{"@id":"https:\/\/zjbocon.com\/?p=2492#primaryimage"},"image":{"@id":"https:\/\/zjbocon.com\/?p=2492#primaryimage"},"thumbnailUrl":"https:\/\/zjbocon.com\/wp-content\/uploads\/2025\/09\/eto-sterilizer-1.webp","datePublished":"2024-12-24T02:37:05+00:00","dateModified":"2025-12-05T01:43:37+00:00","description":"3.4.1 eto sterilizer machine Temperature Setting RangeThe temperature setting range for the eto sterilizer is: 30 to 70\u00b0C,","breadcrumb":{"@id":"https:\/\/zjbocon.com\/?p=2492#breadcrumb"},"inLanguage":"ja","potentialAction":[{"@type":"ReadAction","target":["https:\/\/zjbocon.com\/?p=2492"]}]},{"@type":"ImageObject","inLanguage":"ja","@id":"https:\/\/zjbocon.com\/?p=2492#primaryimage","url":"https:\/\/zjbocon.com\/wp-content\/uploads\/2025\/09\/eto-sterilizer-1.webp","contentUrl":"https:\/\/zjbocon.com\/wp-content\/uploads\/2025\/09\/eto-sterilizer-1.webp","width":1200,"height":1200},{"@type":"BreadcrumbList","@id":"https:\/\/zjbocon.com\/?p=2492#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/zjbocon.com\/"},{"@type":"ListItem","position":2,"name":"Understanding ETO Sterilizer Performance: Keys to Efficiency"}]},{"@type":"WebSite","@id":"https:\/\/zjbocon.com\/#website","url":"https:\/\/zjbocon.com\/","name":"ETO STERILIZER","description":"One-stop Solution Supplier of Ethylene Oxide Sterilization","publisher":{"@id":"https:\/\/zjbocon.com\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/zjbocon.com\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"ja"},{"@type":"Organization","@id":"https:\/\/zjbocon.com\/#organization","name":"ETO STERILIZER","url":"https:\/\/zjbocon.com\/","logo":{"@type":"ImageObject","inLanguage":"ja","@id":"https:\/\/zjbocon.com\/#\/schema\/logo\/image\/","url":"https:\/\/zjbocon.com\/wp-content\/uploads\/2024\/10\/logo-1.webp","contentUrl":"https:\/\/zjbocon.com\/wp-content\/uploads\/2024\/10\/logo-1.webp","width":180,"height":60,"caption":"ETO STERILIZER"},"image":{"@id":"https:\/\/zjbocon.com\/#\/schema\/logo\/image\/"},"sameAs":["https:\/\/www.facebook.com\/profile.php?id=100088482339878","https:\/\/x.com\/BoconAnd","https:\/\/www.linkedin.com\/in\/--06a221139\/"]},{"@type":"Person","@id":"https:\/\/zjbocon.com\/#\/schema\/person\/f12be028b8ae9843a4396dcc8012b425","name":"Bocon Technical Team","image":{"@type":"ImageObject","inLanguage":"ja","@id":"https:\/\/secure.gravatar.com\/avatar\/d7a825658be227f26b237e519f8541e05aabc9ff27b8eec4544a233a48c53be0?s=96&d=identicon&r=g","url":"https:\/\/secure.gravatar.com\/avatar\/d7a825658be227f26b237e519f8541e05aabc9ff27b8eec4544a233a48c53be0?s=96&d=identicon&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/d7a825658be227f26b237e519f8541e05aabc9ff27b8eec4544a233a48c53be0?s=96&d=identicon&r=g","caption":"Bocon Technical Team"},"sameAs":["https:\/\/zjbocon.com\/","https:\/\/www.facebook.com\/profile.php?id=100088482339878","https:\/\/www.linkedin.com\/in\/\/hayley--968190269\/"],"url":"https:\/\/zjbocon.com\/?author=234312599"}]}},"jetpack_publicize_connections":[],"jetpack_featured_media_url":"https:\/\/zjbocon.com\/wp-content\/uploads\/2025\/09\/eto-sterilizer-1.webp","uagb_featured_image_src":{"full":["https:\/\/zjbocon.com\/wp-content\/uploads\/2025\/09\/eto-sterilizer-1.webp",1200,1200,false],"thumbnail":["https:\/\/zjbocon.com\/wp-content\/uploads\/2025\/09\/eto-sterilizer-1-150x150.webp",150,150,true],"medium":["https:\/\/zjbocon.com\/wp-content\/uploads\/2025\/09\/eto-sterilizer-1-300x300.webp",300,300,true],"medium_large":["https:\/\/zjbocon.com\/wp-content\/uploads\/2025\/09\/eto-sterilizer-1-768x768.webp",768,768,true],"large":["https:\/\/zjbocon.com\/wp-content\/uploads\/2025\/09\/eto-sterilizer-1-1024x1024.webp",1024,1024,true],"1536x1536":["https:\/\/zjbocon.com\/wp-content\/uploads\/2025\/09\/eto-sterilizer-1.webp",1200,1200,false],"2048x2048":["https:\/\/zjbocon.com\/wp-content\/uploads\/2025\/09\/eto-sterilizer-1.webp",1200,1200,false],"woocommerce_thumbnail":["https:\/\/zjbocon.com\/wp-content\/uploads\/2025\/09\/eto-sterilizer-1-600x600.webp",600,600,true],"woocommerce_single":["https:\/\/zjbocon.com\/wp-content\/uploads\/2025\/09\/eto-sterilizer-1-600x600.webp",600,600,true],"woocommerce_gallery_thumbnail":["https:\/\/zjbocon.com\/wp-content\/uploads\/2025\/09\/eto-sterilizer-1-100x100.webp",100,100,true]},"uagb_author_info":{"display_name":"Bocon Technical Team","author_link":"https:\/\/zjbocon.com\/?author=234312599"},"uagb_comment_info":0,"uagb_excerpt":"3.4.1 eto sterilizer machine Temperature Setting Range The temperature setting range for the eto sterilizer is: 30 to 70\u00b0C","jetpack_likes_enabled":true,"jetpack_sharing_enabled":true,"jetpack_shortlink":"https:\/\/wp.me\/pgZDV6-Ec","jetpack-related-posts":[{"id":2117,"url":"https:\/\/zjbocon.com\/?p=2117","url_meta":{"origin":2492,"position":0},"title":"Industry Eto Sterilizer Installation Verification","author":"Bocon Technical Team","date":"2024-11-06","format":false,"excerpt":"Industry Eto Sterilizer Installation Verification The installation of Industry Eto Sterilizer and all associated services should comply with the requirements of the construction and engineering drawings. It is recommended to verify the components of the Industry Eto Sterilizer to ensure the installation meets applicable standards and requirements. These equipment components\u2026","rel":"","context":"In &quot;ETO STERILIZER&quot;","block_context":{"text":"ETO STERILIZER","link":"https:\/\/zjbocon.com\/?cat=133124"},"img":{"alt_text":"","src":"https:\/\/i0.wp.com\/zjbocon.com\/wp-content\/uploads\/2024\/10\/sterilizer-station-design-2.webp?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/zjbocon.com\/wp-content\/uploads\/2024\/10\/sterilizer-station-design-2.webp?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/zjbocon.com\/wp-content\/uploads\/2024\/10\/sterilizer-station-design-2.webp?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/zjbocon.com\/wp-content\/uploads\/2024\/10\/sterilizer-station-design-2.webp?resize=700%2C400&ssl=1 2x"},"classes":[]},{"id":2094,"url":"https:\/\/zjbocon.com\/?p=2094","url_meta":{"origin":2492,"position":1},"title":"ETO Sterilizer Manufacturer-HZBOCON","author":"Bocon Technical Team","date":"2024-11-04","format":false,"excerpt":"Hangzhou Bocon Mechanical and Electrical Equipment Co., Ltd., commonly referred to as HZBOCON, stands out as a dedicated Ethylene Oxide (EO\/ETO) sterilizer manufacturer. Established in 2006, HZBOCON has committed itself to the design, development, and manufacturing of EO sterilization equipment, catering to a wide array of industries that require effective\u2026","rel":"","context":"In &quot;ETO STERILIZER&quot;","block_context":{"text":"ETO STERILIZER","link":"https:\/\/zjbocon.com\/?cat=133124"},"img":{"alt_text":"","src":"https:\/\/i0.wp.com\/zjbocon.com\/wp-content\/uploads\/2024\/11\/eto-sterilizer-hzbocon-4.png?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/zjbocon.com\/wp-content\/uploads\/2024\/11\/eto-sterilizer-hzbocon-4.png?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/zjbocon.com\/wp-content\/uploads\/2024\/11\/eto-sterilizer-hzbocon-4.png?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/zjbocon.com\/wp-content\/uploads\/2024\/11\/eto-sterilizer-hzbocon-4.png?resize=700%2C400&ssl=1 2x, https:\/\/i0.wp.com\/zjbocon.com\/wp-content\/uploads\/2024\/11\/eto-sterilizer-hzbocon-4.png?resize=1050%2C600&ssl=1 3x"},"classes":[]},{"id":1950,"url":"https:\/\/zjbocon.com\/?p=1950","url_meta":{"origin":2492,"position":2},"title":"eto sterilization process","author":"Bocon Technical Team","date":"2024-10-23","format":false,"excerpt":"Eto Sterilization is conducted using a eto sterilizer located in a dedicated facility.","rel":"","context":"In &quot;ETO STERILIZER&quot;","block_context":{"text":"ETO STERILIZER","link":"https:\/\/zjbocon.com\/?cat=133124"},"img":{"alt_text":"eto sterilization process","src":"https:\/\/i0.wp.com\/zjbocon.com\/wp-content\/uploads\/2024\/10\/eto-sterilization-process-e1729654271899.webp?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/zjbocon.com\/wp-content\/uploads\/2024\/10\/eto-sterilization-process-e1729654271899.webp?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/zjbocon.com\/wp-content\/uploads\/2024\/10\/eto-sterilization-process-e1729654271899.webp?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/zjbocon.com\/wp-content\/uploads\/2024\/10\/eto-sterilization-process-e1729654271899.webp?resize=700%2C400&ssl=1 2x"},"classes":[]},{"id":2880,"url":"https:\/\/zjbocon.com\/?p=2880","url_meta":{"origin":2492,"position":3},"title":"eto sterile machine manufacturer in china","author":"Bocon Technical Team","date":"2025-01-16","format":false,"excerpt":"Hangzhou Bocon Mechanical and Electrical Equipment Co., Ltd( eto sterile machine manufacturer in china) was established in 2006. The office is located in Hangzhou; And the factory is situated in Jiaxing. HZBOCON primarily engages in the research and development, production, and sales of eto sterile machine, the main advantage is\u2026","rel":"","context":"In &quot;Company News&quot;","block_context":{"text":"Company News","link":"https:\/\/zjbocon.com\/?cat=133125"},"img":{"alt_text":"","src":"https:\/\/i0.wp.com\/zjbocon.com\/wp-content\/uploads\/2025\/09\/cropped-cropped-hzbocon.png?resize=350%2C200&ssl=1","width":350,"height":200},"classes":[]},{"id":2515,"url":"https:\/\/zjbocon.com\/?p=2515","url_meta":{"origin":2492,"position":4},"title":"12m3 eto sterilizer is ready to send to our customer","author":"Bocon Technical Team","date":"2024-12-27","format":false,"excerpt":"12m3 eto sterilizer is ready to send to our customer","rel":"","context":"In &quot;Company News&quot;","block_context":{"text":"Company News","link":"https:\/\/zjbocon.com\/?cat=133125"},"img":{"alt_text":"","src":"https:\/\/i0.wp.com\/zjbocon.com\/wp-content\/uploads\/2025\/09\/eto-sterilizer-3.webp?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/zjbocon.com\/wp-content\/uploads\/2025\/09\/eto-sterilizer-3.webp?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/zjbocon.com\/wp-content\/uploads\/2025\/09\/eto-sterilizer-3.webp?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/zjbocon.com\/wp-content\/uploads\/2025\/09\/eto-sterilizer-3.webp?resize=700%2C400&ssl=1 2x, https:\/\/i0.wp.com\/zjbocon.com\/wp-content\/uploads\/2025\/09\/eto-sterilizer-3.webp?resize=1050%2C600&ssl=1 3x"},"classes":[]},{"id":2064,"url":"https:\/\/zjbocon.com\/?p=2064","url_meta":{"origin":2492,"position":5},"title":"OQ IN ETO STERILIZATION MACHINE","author":"Bocon Technical Team","date":"2024-10-31","format":false,"excerpt":"In OQ, the performance of the relevant auxiliary system should be determined and the software system should be tested by simulating the fault conditions.","rel":"","context":"In &quot;ETO STERILIZER&quot;","block_context":{"text":"ETO STERILIZER","link":"https:\/\/zjbocon.com\/?cat=133124"},"img":{"alt_text":"","src":"https:\/\/i0.wp.com\/zjbocon.com\/wp-content\/uploads\/2025\/09\/Ethylene-Oxide-Sterilizer-Installation-Guide-1-scaled.webp?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/zjbocon.com\/wp-content\/uploads\/2025\/09\/Ethylene-Oxide-Sterilizer-Installation-Guide-1-scaled.webp?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/zjbocon.com\/wp-content\/uploads\/2025\/09\/Ethylene-Oxide-Sterilizer-Installation-Guide-1-scaled.webp?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/zjbocon.com\/wp-content\/uploads\/2025\/09\/Ethylene-Oxide-Sterilizer-Installation-Guide-1-scaled.webp?resize=700%2C400&ssl=1 2x, https:\/\/i0.wp.com\/zjbocon.com\/wp-content\/uploads\/2025\/09\/Ethylene-Oxide-Sterilizer-Installation-Guide-1-scaled.webp?resize=1050%2C600&ssl=1 3x, https:\/\/i0.wp.com\/zjbocon.com\/wp-content\/uploads\/2025\/09\/Ethylene-Oxide-Sterilizer-Installation-Guide-1-scaled.webp?resize=1400%2C800&ssl=1 4x"},"classes":[]}],"_links":{"self":[{"href":"https:\/\/zjbocon.com\/index.php?rest_route=\/wp\/v2\/posts\/2492","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/zjbocon.com\/index.php?rest_route=\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/zjbocon.com\/index.php?rest_route=\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/zjbocon.com\/index.php?rest_route=\/wp\/v2\/users\/234312599"}],"replies":[{"embeddable":true,"href":"https:\/\/zjbocon.com\/index.php?rest_route=%2Fwp%2Fv2%2Fcomments&post=2492"}],"version-history":[{"count":5,"href":"https:\/\/zjbocon.com\/index.php?rest_route=\/wp\/v2\/posts\/2492\/revisions"}],"predecessor-version":[{"id":8862,"href":"https:\/\/zjbocon.com\/index.php?rest_route=\/wp\/v2\/posts\/2492\/revisions\/8862"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/zjbocon.com\/index.php?rest_route=\/wp\/v2\/media\/8489"}],"wp:attachment":[{"href":"https:\/\/zjbocon.com\/index.php?rest_route=%2Fwp%2Fv2%2Fmedia&parent=2492"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/zjbocon.com\/index.php?rest_route=%2Fwp%2Fv2%2Fcategories&post=2492"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/zjbocon.com\/index.php?rest_route=%2Fwp%2Fv2%2Ftags&post=2492"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}