{"id":7286,"date":"2025-07-29T12:02:12","date_gmt":"2025-07-29T04:02:12","guid":{"rendered":"https:\/\/zjbocon.com\/?p=7286"},"modified":"2025-10-01T19:30:30","modified_gmt":"2025-10-01T11:30:30","slug":"eto-sterilization-re-qualification","status":"publish","type":"post","link":"https:\/\/zjbocon.com\/?p=7286","title":{"rendered":"ETO Sterilization Re-qualification"},"content":{"rendered":"\n<h2 class=\"wp-block-heading\" id=\"h-eto-sterilization-re-qualification-requirements\">ETO ಕ್ರಿಮಿನಾಶಕ ಮರು-ಅರ್ಹತೆಯ ಅಗತ್ಯತೆಗಳು<\/h2>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"h-1-re-qualification-frequency\">1. ಮರು-ಅರ್ಹತೆಯ ಆವರ್ತನ<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">\u2022&nbsp;<strong>ಕನಿಷ್ಠ ವಾರ್ಷಿಕ ಅವಶ್ಯಕತೆ<\/strong><br>\u2022 At least once per year, verification data, subsequent re-validation data, and routine processing data must be reviewed<br>\u2022 The scope of re-qualification must be determined and documented<br>\u2022 The review procedure shall be documented<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"h-2-is-re-qualification-needed-if-no-product-changes-occur\">2. ಯಾವುದೇ ಉತ್ಪನ್ನ ಬದಲಾವಣೆಗಳು ಸಂಭವಿಸದಿದ್ದರೆ ಮರು-ಅರ್ಹತೆಯ ಅಗತ್ಯವಿದೆಯೇ?<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">\u2022&nbsp;<strong>ಹೌದು, ಮರು-ಅರ್ಹತೆ ಇನ್ನೂ ಅಗತ್ಯವಿದೆ<\/strong><\/p>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"h-3-re-qualification-items\">3. ಮರು-ಅರ್ಹತೆಯ ಐಟಂಗಳು<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">\u2022&nbsp;<strong>ಕೆಲವು ಪೂರ್ವಾಪೇಕ್ಷಿತಗಳ ಆಧಾರದ ಮೇಲೆ, ಈ ಕೆಳಗಿನ ಆಯ್ಕೆಗಳು ಲಭ್ಯವಿದೆ<\/strong>:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>ಪೂರ್ಣ ಮರು-ಅರ್ಹತೆ<\/li>\n\n\n\n<li>ಭೌತಿಕ ಅಥವಾ ಸೂಕ್ಷ್ಮಜೀವಿಗಳ ಮರು-ಮೌಲ್ಯಮಾಪನ ಅಗತ್ಯವಿಲ್ಲ<\/li>\n\n\n\n<li>ಸಣ್ಣ-ಪ್ರಮಾಣದ ಸೂಕ್ಷ್ಮಜೀವಿಯ ಕಾರ್ಯಕ್ಷಮತೆ ಮೌಲ್ಯಮಾಪನ<\/li>\n<\/ul>\n\n\n\n<h2 class=\"wp-block-heading\"><strong>ಮರು-ಅರ್ಹತೆಗಾಗಿ ಪೂರ್ವಾಪೇಕ್ಷಿತಗಳು<\/strong><\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">a) The following must be reviewed\/tested:<br>ಬಿ) ಯಾವುದಾದರೂ ಆಗಿರಲಿ<strong>ಗಮನಾರ್ಹ ಬದಲಾವಣೆಗಳು<\/strong>&nbsp;ಉತ್ಪನ್ನದ ಸಂತಾನಹೀನತೆಯ ಮೇಲೆ ಪರಿಣಾಮ ಬೀರುವುದು ಸಂಭವಿಸಿದೆ:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>ಉತ್ಪನ್ನ ವಿನ್ಯಾಸ<\/li>\n\n\n\n<li>Manufacturing\/packaging materials<\/li>\n\n\n\n<li>PCD (ಪ್ರಕ್ರಿಯೆ ಚಾಲೆಂಜ್ ಸಾಧನ)<\/li>\n\n\n\n<li>ಪೂರೈಕೆದಾರರು<\/li>\n\n\n\n<li>Manufacturing areas\/facilities<\/li>\n\n\n\n<li>ಲೋಡ್ ಕಾನ್ಫಿಗರೇಶನ್‌ಗಳು ಅಥವಾ ಉತ್ಪಾದನಾ ಪ್ರಕ್ರಿಯೆಗಳು<br>ಸಿ)<strong>ಬಯೋಬರ್ಡನ್ ಪ್ರವೃತ್ತಿ ವಿಶ್ಲೇಷಣೆ<\/strong>&nbsp;ಉತ್ಪನ್ನಗಳ;<br>d) ಇರಲಿ<strong>ತಾಪಮಾನ ವಿತರಣಾ ಅಧ್ಯಯನಗಳು<\/strong>&nbsp;ಮತ್ತು ಕ್ರಿಮಿನಾಶಕ ಕಾರ್ಯಾಚರಣೆಯು ಕೊನೆಯ ಅರ್ಹತೆಯ ನಂತರ ಗಮನಾರ್ಹ ಬದಲಾವಣೆಗಳನ್ನು ಪ್ರದರ್ಶಿಸುತ್ತದೆ;<br>ಇ) ಇರಲಿ<strong>ತಾಪಮಾನ ವಿತರಣೆ ಮತ್ತು ಮರುಬಳಕೆ ತಪಾಸಣೆ<\/strong>&nbsp;ಪೂರ್ವಸಿದ್ಧತಾ ಕೋಣೆಗಳಲ್ಲಿ ಅಥವಾ ಗಾಳಿಯಾಡುವ ವಲಯಗಳು ಕೊನೆಯ ಅರ್ಹತೆಯ ನಂತರ ಗಮನಾರ್ಹ ಬದಲಾವಣೆಗಳನ್ನು ತೋರಿಸುತ್ತವೆ;<br>ಎಫ್) ETO ಕ್ರಿಮಿನಾಶಕವಾಗಲಿ<strong> ಪ್ರಕ್ರಿಯೆ ಇತಿಹಾಸ<\/strong>&nbsp;ಕೊನೆಯ ದೃಢೀಕರಣವು ಪುನರುತ್ಪಾದನೆಯನ್ನು ಪ್ರದರ್ಶಿಸುವುದರಿಂದ;<br>g) ಇರಲಿ<strong>ನಿಯಂತ್ರಣ ಮತ್ತು ತಡೆಗಟ್ಟುವ ನಿರ್ವಹಣೆ ದಾಖಲೆಗಳನ್ನು ಬದಲಾಯಿಸಿ<\/strong>&nbsp;ಪ್ರಕ್ರಿಯೆಯ ಮೇಲೆ ಪರಿಣಾಮ ಬೀರುವ ಯಾವುದೇ ಸಲಕರಣೆ ಮಾರ್ಪಾಡುಗಳನ್ನು ಖಚಿತಪಡಿಸಿ;<br>h) ಇರಲಿ<strong>ETO ಕ್ರಿಮಿನಾಶಕ ಪ್ರಕ್ರಿಯೆಗೆ ಯಾವುದೇ ಬದಲಾವಣೆಗಳಿಲ್ಲ<\/strong>&nbsp;ಸಂತಾನಹೀನತೆಯ ಮೇಲೆ ಪರಿಣಾಮ ಬೀರುವ ಸಂಭವಿಸಿದೆ;<br>i) ವೇಳೆ<strong>ETO ಕ್ರಿಮಿನಾಶಕ ಪ್ರಕ್ರಿಯೆಯ ವಿಶೇಷಣಗಳು ಬದಲಾಗಿವೆ<\/strong>, ಮರು-ಅರ್ಹತೆಯು ಪರಿಶೀಲನೆಯನ್ನು ಒಳಗೊಂಡಿರಬೇಕು<strong>EO ಶೇಷ ಮಿತಿಗಳು<\/strong>&nbsp;ನಿಯಂತ್ರಕ ಅಗತ್ಯತೆಗಳ ಅನುಸರಣೆ.<\/li>\n<\/ul>\n\n\n\n<h3 class=\"wp-block-heading\"><strong>ನಿಯಂತ್ರಕ ಮಾನದಂಡಗಳು<\/strong><\/h3>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong>ISO 11135:2014<\/strong>&nbsp;<em>(ಸೆ. 9.2: ಅರ್ಹತೆಯ ಮಾನದಂಡ)<\/em><\/li>\n\n\n\n<li><strong>FDA 21 CFR 211.113<\/strong>&nbsp;<em>(ಕ್ರಿಮಿನಾಶಕ ಪ್ರಕ್ರಿಯೆ ನಿಯಂತ್ರಣಗಳು)<\/em><\/li>\n\n\n\n<li><strong>EU GMP ಅನೆಕ್ಸ್ 1:2022<\/strong>&nbsp;<em>(ಸೆ. 8.5: ಮರುಮೌಲ್ಯಮಾಪನ ಅಗತ್ಯತೆಗಳು)<\/em><\/li>\n<\/ul>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"h-eto-sterilization-re-qualification-requirements-0\"><strong>ETO ಕ್ರಿಮಿನಾಶಕ ಮರು-ಅರ್ಹತೆಯ ಅಗತ್ಯತೆಗಳು<\/strong><\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">ಮರು-ಅರ್ಹತೆ ಹಾಗಿಲ್ಲ<strong>ಚೇಂಬರ್ ಕಾರ್ಯಕ್ಷಮತೆ ಮತ್ತು ವಾರ್ಷಿಕ ಎಂಜಿನಿಯರಿಂಗ್ ಬದಲಾವಣೆಗಳ ವಿಮರ್ಶೆಯನ್ನು ಒಳಗೊಂಡಿರುತ್ತದೆ<\/strong>&nbsp;to ensure the original IQ\/OQ results remain valid. The review must cover:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong>Preconditioning zone temperature\/humidity profiles<\/strong>&nbsp;(ಅನ್ವಯಿಸಿದರೆ);<\/li>\n\n\n\n<li><strong>ನಿಜವಾದ ಖಾಲಿ ಚೇಂಬರ್ ಆರ್ದ್ರತೆಯ ಪ್ರೊಫೈಲ್ಗಳು<\/strong>;<\/li>\n\n\n\n<li><strong>ಗಾಳಿಯ ವಲಯದ ತಾಪಮಾನ<\/strong>&nbsp;(ಅನ್ವಯಿಸಿದರೆ);<\/li>\n\n\n\n<li><strong>ಹೆಚ್ಚುವರಿಯಾಗಿ, ಪ್ರಕ್ರಿಯೆಯ ವಿಶೇಷಣಗಳನ್ನು ಪೂರೈಸಿದರೂ ಸಹ<\/strong>, inspections must be triggered by:\n<ul class=\"wp-block-list\">\n<li>ಸಲಕರಣೆಗಳ ಕಾರ್ಯಕ್ಷಮತೆಯಲ್ಲಿ ಪ್ರತಿಕೂಲ ಪ್ರವೃತ್ತಿಗಳು,<\/li>\n\n\n\n<li>ಕ್ರಿಮಿನಾಶಕ ವೈಫಲ್ಯಗಳು;<\/li>\n\n\n\n<li>ಮರು-ಮೌಲ್ಯಮಾಪನವನ್ನು ಸಮರ್ಥಿಸಲಾಗಿದೆಯೇ ಎಂದು ನಿರ್ಧರಿಸಲು.<\/li>\n<\/ul>\n<\/li>\n\n\n\n<li><strong>ಕ್ರಿಮಿನಾಶಕ ತಜ್ಞರು<\/strong>&nbsp;ಅಗತ್ಯವಿರುವ ವ್ಯಾಪ್ತಿಯನ್ನು ವ್ಯಾಖ್ಯಾನಿಸಬೇಕು<strong>ಭೌತಿಕ ಮತ್ತು ಸೂಕ್ಷ್ಮಜೀವಿಗಳ ಮರು ಮೌಲ್ಯಮಾಪನ<\/strong>&nbsp;ವಿಮರ್ಶೆ ಫಲಿತಾಂಶಗಳ ಆಧಾರದ ಮೇಲೆ.<\/li>\n<\/ul>\n\n\n\n<h2 class=\"wp-block-heading\"><strong>ಕ್ರಿಮಿನಾಶಕ ಮರು-ಅರ್ಹತೆಗಾಗಿ ನಿರ್ಣಾಯಕ ಪರಿಗಣನೆಗಳು<\/strong><\/h2>\n\n\n\n<h3 class=\"wp-block-heading\"><strong>1. ಮಹತ್ವದ ಬದಲಾವಣೆಗಳನ್ನು ನಿರ್ವಹಿಸುವುದು<\/strong><\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">\u2022 If&nbsp;<strong>ಪ್ರಮುಖ ಬದಲಾವಣೆಗಳು<\/strong>&nbsp;are identified during re-qualification, re-execution of IQ\/OQ\/PQ may be required:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong>IQ (ಅನುಸ್ಥಾಪನಾ ಅರ್ಹತೆ)<\/strong>: Verify modified equipment\/software installation.<\/li>\n\n\n\n<li><strong>OQ (ಕಾರ್ಯಾಚರಣೆಯ ಅರ್ಹತೆ)<\/strong>: ಪ್ರಭಾವಿತ ಕ್ರಿಯಾತ್ಮಕ ನಿಯತಾಂಕಗಳನ್ನು ಮರುಪರೀಕ್ಷೆ.<\/li>\n\n\n\n<li><strong>PQ (ಕಾರ್ಯಕ್ಷಮತೆಯ ಅರ್ಹತೆ)<\/strong>: ಹೊಸ ಪರಿಸ್ಥಿತಿಗಳಲ್ಲಿ ಕ್ರಿಮಿನಾಶಕ ಪರಿಣಾಮಕಾರಿತ್ವವನ್ನು ಮರು ಮೌಲ್ಯೀಕರಿಸಿ.<\/li>\n<\/ul>\n\n\n\n<h3 class=\"wp-block-heading\"><strong>2. ಪ್ಯಾರಾಮೆಟ್ರಿಕ್ ಬಿಡುಗಡೆಗೆ ಹೆಚ್ಚುವರಿ ಅಗತ್ಯತೆಗಳು<\/strong><\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">ಬಳಸುವ ಸೌಲಭ್ಯಗಳಿಗಾಗಿ<strong>ಪ್ಯಾರಾಮೆಟ್ರಿಕ್ ಬಿಡುಗಡೆ<\/strong>&nbsp;(BI ಪರೀಕ್ಷೆಗಿಂತ ಪ್ರಕ್ರಿಯೆಯ ಡೇಟಾವನ್ನು ಅವಲಂಬಿಸಿ):<br>a)<strong>ಮರು ಮೌಲ್ಯಮಾಪನ ಆವರ್ತನ<\/strong>: ನಿರ್ವಹಿಸಬೇಕು<strong>ಕನಿಷ್ಠ ವಾರ್ಷಿಕವಾಗಿ<\/strong>;<br>b)<strong>ಮರು ಮೌಲ್ಯಮಾಪನ ವ್ಯಾಪ್ತಿ<\/strong>: ಒಳಗೊಂಡಿರಬೇಕು<strong>ಸೂಕ್ಷ್ಮ ಜೀವವಿಜ್ಞಾನದ ಅಧ್ಯಯನಗಳು<\/strong>&nbsp;ದೃಢೀಕರಿಸಲು:<\/p>\n\n\n\n<h2 class=\"wp-block-heading\"><strong>Situations Requiring Full Requalification (IQ\/OQ\/PQ):<\/strong><\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">a)<strong>ಕ್ರಿಮಿನಾಶಕದ ಪ್ರಮುಖ ನಿರ್ವಹಣೆ<\/strong>;<br>b)<strong>ರಚನಾತ್ಮಕ, ಸ್ಥಳ ಅಥವಾ ಪರಿಸರ ಬದಲಾವಣೆಗಳು<\/strong>;<br>ಸಿ)<strong>ವಿವರಿಸಲಾಗದ ಸಂತಾನಹೀನತೆಯ ವೈಫಲ್ಯಗಳು<\/strong>;<br>d)<strong>Changes in EO supply\/delivery, diluent, or chamber load configuration<\/strong>.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\"><strong>ದೈಹಿಕ ಅಥವಾ ಸೂಕ್ಷ್ಮಜೀವಿಯ ಮರು-ಅರ್ಹತೆಯಿಂದ ವಿನಾಯಿತಿ<\/strong><\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">ಕೆಳಗಿನ ಷರತ್ತುಗಳನ್ನು ಪೂರೈಸಿದಾಗ:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong>ಯಾವುದೇ ಬದಲಾವಣೆಗಳಿಲ್ಲ<\/strong>&nbsp;in product, packaging, equipment\/services, or processes;<\/li>\n\n\n\n<li><strong>ಚೇಂಬರ್ ಕಾರ್ಯಕ್ಷಮತೆ ಮತ್ತು ಎಂಜಿನಿಯರಿಂಗ್ ವಿಮರ್ಶೆ<\/strong>&nbsp;ಅರ್ಹರಾಗಿದ್ದಾರೆ;<\/li>\n\n\n\n<li><strong>ವಾಡಿಕೆಯ ಕ್ರಿಮಿನಾಶಕ ಪ್ರಕ್ರಿಯೆಗಳು<\/strong>&nbsp;ಅವಧಿಯಲ್ಲಿ ವಿಶ್ವಾಸಾರ್ಹವಾಗಿ ಕಾರ್ಯನಿರ್ವಹಿಸಿದ್ದಾರೆ;<br>?<strong>ವೃತ್ತಿಪರ ತೀರ್ಪು<\/strong>&nbsp;ದೈಹಿಕ ಅಥವಾ ಸೂಕ್ಷ್ಮಜೀವಿಯ ಮರು-ಅರ್ಹತೆ ಎಂದು ನಿರ್ಧರಿಸಬಹುದು<strong>ಅಗತ್ಯವಿಲ್ಲ<\/strong>&nbsp;ಮುಂದಿನ ವಿಮರ್ಶೆಯವರೆಗೆ.<\/li>\n<\/ul>\n\n\n\n<h2 class=\"wp-block-heading\"><strong>ಸೀಮಿತ ಪ್ರಮಾಣದ ಸೂಕ್ಷ್ಮಜೀವಿಯ ಕಾರ್ಯಕ್ಷಮತೆಯ ಅರ್ಹತೆ<\/strong><\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">\u2022&nbsp;<strong>ನಿರ್ದಿಷ್ಟ ಸಂದರ್ಭಗಳಲ್ಲಿ ಅಗತ್ಯವಿರಬಹುದು<\/strong>, ಉದಾಹರಣೆಗೆ:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>ಉತ್ಪನ್ನದ ಜೈವಿಕ ಹೊರೆಗೆ ಸಂಬಂಧಿಸಿದಂತೆ ಬಿಐಗಳ ಮುಂದುವರಿದ ಸೂಕ್ತತೆಯನ್ನು ಪರಿಶೀಲಿಸುವುದು;<\/li>\n\n\n\n<li>ಇಲ್ಲ ಎಂಬುದಕ್ಕೆ ಪುರಾವೆ ಒದಗಿಸುವುದು<strong>ಅನಪೇಕ್ಷಿತ ಬದಲಾವಣೆಗಳು<\/strong>&nbsp;ನಿರ್ದಿಷ್ಟ ಸಮಯದ ಮಧ್ಯಂತರದ ನಂತರ ಹಿಂದಿನ (ಮರು) ಅರ್ಹತಾ ಅಧ್ಯಯನದಿಂದ ಸಂಭವಿಸಿದೆ.<br>\u2022&nbsp;<strong>ಸಾಮಾನ್ಯ ಅವಶ್ಯಕತೆಗಳು (ಕನಿಷ್ಠ)<\/strong>:<\/li>\n\n\n\n<li>ಒಂದು<strong>ಸಣ್ಣ-ಚಕ್ರ ಅಥವಾ ಅರ್ಧ-ಚಕ್ರದ ಓಟ<\/strong>;<\/li>\n\n\n\n<li>ಸೇರಿದಂತೆ<strong>ತಾಪಮಾನ ಮತ್ತು ತೇವಾಂಶ ಮಾಪನಗಳು<\/strong>&nbsp;ಕ್ರಿಮಿನಾಶಕ ವಸ್ತುಗಳ.<\/li>\n<\/ul>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"h-if-you-want-to-know-more\">ನೀವು ಇನ್ನಷ್ಟು ತಿಳಿದುಕೊಳ್ಳಲು ಬಯಸಿದರೆ<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">ಫೋನ್:<a href=\"https:\/\/wa.me\/8619975258603\">+8619975258603<\/a><\/p>\n\n\n\n<p class=\"wp-block-paragraph\">ಇಮೇಲ್:<a href=\"mailto:hayley@hzbocon.com\">hayley@hzbocon.com<\/a><\/p>\n\n\n\n<p class=\"wp-block-paragraph\">ಸ್ಥಳೀಯ ಸೈಟ್: ಕೊಠಡಿ 1202, ಕೈಟಾಂಗ್ ಝೊಂಗ್ಕ್ಸಿನ್, ಕ್ಸಿಯಾಶಾ ಜಿಲ್ಲೆ, ಹ್ಯಾಂಗ್ಝೌ ನಗರ, ಝೆಜಿಯಾಂಗ್ ಪ್ರಾಂತ್ಯ, ಚೀನಾ<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">ವೆಬ್‌ಸೈಟ್:<a href=\"https:\/\/www.hzbocon.com\/\">hzbocon.com<\/a><a href=\"https:\/\/zjbocon.com\/\">zjbocon.com<\/a><\/p>\n\n\n\n<div class=\"wp-block-uagb-image uagb-block-9d7632fc wp-block-uagb-image--layout-default wp-block-uagb-image--effect-static wp-block-uagb-image--align-none\"><figure class=\"wp-block-uagb-image__figure\"><img loading=\"lazy\" decoding=\"async\" src=\"https:\/\/zjbocon.com\/wp-content\/uploads\/2025\/09\/eto-sterilizer-9-1024x1024.webp\" alt=\"\" class=\"uag-image-8487\" width=\"1024\" height=\"1024\" title=\"eto-sterilizer-9\" role=\"img\" \><\/figure><\/div>\n\n\n\n<p class=\"wp-block-paragraph\"><\/p>\n","protected":false},"excerpt":{"rendered":"<p>ETO Sterilization Re-qualification Requirements 1. Re-qualification Frequency \u2022&nbsp;Minimum annual requirement\u2022 At least once per year, verification data, subsequent re-validation data, [&hellip;]<\/p>\n","protected":false},"author":234312599,"featured_media":8487,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_uag_custom_page_level_css":"","site-sidebar-layout":"default","site-content-layout":"","ast-site-content-layout":"default","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","ast-disable-related-posts":"","theme-transparent-header-meta":"","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"set","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"_jetpack_newsletter_access":"","_jetpack_dont_email_post_to_subs":false,"_jetpack_newsletter_tier_id":0,"_jetpack_memberships_contains_paywalled_content":false,"_jetpack_feature_clip_id":0,"_jetpack_memberships_contains_paid_content":false,"footnotes":"","jetpack_publicize_message":"","jetpack_publicize_feature_enabled":true,"jetpack_social_post_already_shared":false,"jetpack_social_options":{"image_generator_settings":{"template":"highway","default_image_id":0,"enabled":false},"version":2},"jetpack_post_was_ever_published":false},"categories":[133125,133124],"tags":[],"class_list":["post-7286","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-company-news","category-eto-sterilizer"],"yoast_head":"<!-- This site is optimized with the Yoast SEO Premium plugin v27.2 (Yoast SEO v28.0) - https:\/\/yoast.com\/product\/yoast-seo-premium-wordpress\/ -->\n<title>ETO ಕ್ರಿಮಿನಾಶಕ ಮರು-ಅರ್ಹತೆ - ETO ಕ್ರಿಮಿನಾಶಕ<\/title>\n<meta name=\"description\" content=\"\u2022\u00a0Minimum annual requirement\u2022 At least once per year, verification data, subsequent re-validation and\" \>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \>\n<link rel=\"canonical\" href=\"https:\/\/zjbocon.com\/?p=7286\" \>\n<meta property=\"og:locale\" content=\"en_US\" \>\n<meta property=\"og:type\" content=\"article\" \>\n<meta property=\"og:title\" content=\"ETO Sterilization Re-qualification\" \>\n<meta property=\"og:description\" content=\"\u2022\u00a0Minimum annual requirement\u2022 At least once per year, verification data, subsequent re-validation and\" \>\n<meta property=\"og:url\" content=\"https:\/\/zjbocon.com\/?p=7286\" \>\n<meta property=\"og:site_name\" content=\"ETO STERILIZER\" \>\n<meta property=\"article:publisher\" content=\"https:\/\/www.facebook.com\/profile.php?id=100088482339878\" \>\n<meta property=\"article:author\" content=\"https:\/\/www.facebook.com\/profile.php?id=100088482339878\" \>\n<meta property=\"article:published_time\" content=\"2025-07-29T04:02:12+00:00\" \>\n<meta property=\"article:modified_time\" content=\"2025-10-01T11:30:30+00:00\" \>\n<meta property=\"og:image\" content=\"https:\/\/zjbocon.com\/wp-content\/uploads\/2025\/09\/eto-sterilizer-9.webp\" \>\n\t<meta property=\"og:image:width\" content=\"1200\" \>\n\t<meta property=\"og:image:height\" content=\"1200\" \>\n\t<meta property=\"og:image:type\" content=\"image\/webp\" \>\n<meta name=\"author\" content=\"Bocon Technical Team\" \>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \>\n<meta name=\"twitter:creator\" content=\"@BoconAnd\" \>\n<meta name=\"twitter:site\" content=\"@BoconAnd\" \>\n<meta name=\"twitter:label1\" content=\"Written by\" \>\n\t<meta name=\"twitter:data1\" content=\"Bocon Technical Team\" \>\n\t<meta name=\"twitter:label2\" content=\"Est. reading time\" \>\n\t<meta name=\"twitter:data2\" content=\"3 minutes\" \>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\\\/\\\/zjbocon.com\\\/?p=7286#article\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/zjbocon.com\\\/?p=7286\"},\"author\":{\"name\":\"Bocon Technical Team\",\"@id\":\"https:\\\/\\\/zjbocon.com\\\/#\\\/schema\\\/person\\\/f12be028b8ae9843a4396dcc8012b425\"},\"headline\":\"ETO Sterilization Re-qualification\",\"datePublished\":\"2025-07-29T04:02:12+00:00\",\"dateModified\":\"2025-10-01T11:30:30+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/zjbocon.com\\\/?p=7286\"},\"wordCount\":634,\"commentCount\":0,\"publisher\":{\"@id\":\"https:\\\/\\\/zjbocon.com\\\/#organization\"},\"image\":{\"@id\":\"https:\\\/\\\/zjbocon.com\\\/?p=7286#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/zjbocon.com\\\/wp-content\\\/uploads\\\/2025\\\/09\\\/eto-sterilizer-9.webp\",\"articleSection\":[\"Company News\",\"ETO STERILIZER\"],\"inLanguage\":\"kn\",\"potentialAction\":[{\"@type\":\"CommentAction\",\"name\":\"Comment\",\"target\":[\"https:\\\/\\\/zjbocon.com\\\/?p=7286#respond\"]}]},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/zjbocon.com\\\/?p=7286\",\"url\":\"https:\\\/\\\/zjbocon.com\\\/?p=7286\",\"name\":\"ETO Sterilization Re-qualification - ETO STERILIZER\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/zjbocon.com\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/zjbocon.com\\\/?p=7286#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/zjbocon.com\\\/?p=7286#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/zjbocon.com\\\/wp-content\\\/uploads\\\/2025\\\/09\\\/eto-sterilizer-9.webp\",\"datePublished\":\"2025-07-29T04:02:12+00:00\",\"dateModified\":\"2025-10-01T11:30:30+00:00\",\"description\":\"\u2022\u00a0Minimum annual requirement\u2022 At least once per year, verification data, subsequent re-validation data, and\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/zjbocon.com\\\/?p=7286#breadcrumb\"},\"inLanguage\":\"kn\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/zjbocon.com\\\/?p=7286\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"kn\",\"@id\":\"https:\\\/\\\/zjbocon.com\\\/?p=7286#primaryimage\",\"url\":\"https:\\\/\\\/zjbocon.com\\\/wp-content\\\/uploads\\\/2025\\\/09\\\/eto-sterilizer-9.webp\",\"contentUrl\":\"https:\\\/\\\/zjbocon.com\\\/wp-content\\\/uploads\\\/2025\\\/09\\\/eto-sterilizer-9.webp\",\"width\":1200,\"height\":1200,\"caption\":\"ETO STERILIZER-HZBOCON\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/zjbocon.com\\\/?p=7286#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/zjbocon.com\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"ETO Sterilization Re-qualification\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/zjbocon.com\\\/#website\",\"url\":\"https:\\\/\\\/zjbocon.com\\\/\",\"name\":\"ETO STERILIZER\",\"description\":\"One-stop Solution Supplier of Ethylene Oxide Sterilization\",\"publisher\":{\"@id\":\"https:\\\/\\\/zjbocon.com\\\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/zjbocon.com\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"kn\"},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/zjbocon.com\\\/#organization\",\"name\":\"ETO STERILIZER\",\"url\":\"https:\\\/\\\/zjbocon.com\\\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"kn\",\"@id\":\"https:\\\/\\\/zjbocon.com\\\/#\\\/schema\\\/logo\\\/image\\\/\",\"url\":\"https:\\\/\\\/zjbocon.com\\\/wp-content\\\/uploads\\\/2024\\\/10\\\/logo-1.webp\",\"contentUrl\":\"https:\\\/\\\/zjbocon.com\\\/wp-content\\\/uploads\\\/2024\\\/10\\\/logo-1.webp\",\"width\":180,\"height\":60,\"caption\":\"ETO STERILIZER\"},\"image\":{\"@id\":\"https:\\\/\\\/zjbocon.com\\\/#\\\/schema\\\/logo\\\/image\\\/\"},\"sameAs\":[\"https:\\\/\\\/www.facebook.com\\\/profile.php?id=100088482339878\",\"https:\\\/\\\/x.com\\\/BoconAnd\",\"https:\\\/\\\/www.linkedin.com\\\/in\\\/--06a221139\\\/\"]},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/zjbocon.com\\\/#\\\/schema\\\/person\\\/f12be028b8ae9843a4396dcc8012b425\",\"name\":\"Bocon Technical Team\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"kn\",\"@id\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/d7a825658be227f26b237e519f8541e05aabc9ff27b8eec4544a233a48c53be0?s=96&d=identicon&r=g\",\"url\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/d7a825658be227f26b237e519f8541e05aabc9ff27b8eec4544a233a48c53be0?s=96&d=identicon&r=g\",\"contentUrl\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/d7a825658be227f26b237e519f8541e05aabc9ff27b8eec4544a233a48c53be0?s=96&d=identicon&r=g\",\"caption\":\"Bocon Technical Team\"},\"sameAs\":[\"https:\\\/\\\/zjbocon.com\\\/\",\"https:\\\/\\\/www.facebook.com\\\/profile.php?id=100088482339878\",\"https:\\\/\\\/www.linkedin.com\\\/in\\\/\\\/hayley--968190269\\\/\"],\"url\":\"https:\\\/\\\/zjbocon.com\\\/?author=234312599\"}]}<\/script>\n<!-- \/ Yoast SEO Premium plugin. -->","yoast_head_json":{"title":"ETO Sterilization Re-qualification - ETO STERILIZER","description":"\u2022\u00a0Minimum annual requirement\u2022 At least once per year, verification data, subsequent re-validation data, and","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/zjbocon.com\/?p=7286","og_locale":"en_US","og_type":"article","og_title":"ETO Sterilization Re-qualification","og_description":"\u2022\u00a0Minimum annual requirement\u2022 At least once per year, verification data, subsequent re-validation data, and","og_url":"https:\/\/zjbocon.com\/?p=7286","og_site_name":"ETO STERILIZER","article_publisher":"https:\/\/www.facebook.com\/profile.php?id=100088482339878","article_author":"https:\/\/www.facebook.com\/profile.php?id=100088482339878","article_published_time":"2025-07-29T04:02:12+00:00","article_modified_time":"2025-10-01T11:30:30+00:00","og_image":[{"width":1200,"height":1200,"url":"https:\/\/zjbocon.com\/wp-content\/uploads\/2025\/09\/eto-sterilizer-9.webp","type":"image\/webp"}],"author":"Bocon Technical Team","twitter_card":"summary_large_image","twitter_creator":"@BoconAnd","twitter_site":"@BoconAnd","twitter_misc":{"Written by":"Bocon Technical Team","Est. reading time":"3 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/zjbocon.com\/?p=7286#article","isPartOf":{"@id":"https:\/\/zjbocon.com\/?p=7286"},"author":{"name":"Bocon Technical Team","@id":"https:\/\/zjbocon.com\/#\/schema\/person\/f12be028b8ae9843a4396dcc8012b425"},"headline":"ETO Sterilization Re-qualification","datePublished":"2025-07-29T04:02:12+00:00","dateModified":"2025-10-01T11:30:30+00:00","mainEntityOfPage":{"@id":"https:\/\/zjbocon.com\/?p=7286"},"wordCount":634,"commentCount":0,"publisher":{"@id":"https:\/\/zjbocon.com\/#organization"},"image":{"@id":"https:\/\/zjbocon.com\/?p=7286#primaryimage"},"thumbnailUrl":"https:\/\/zjbocon.com\/wp-content\/uploads\/2025\/09\/eto-sterilizer-9.webp","articleSection":["Company News","ETO STERILIZER"],"inLanguage":"kn","potentialAction":[{"@type":"CommentAction","name":"Comment","target":["https:\/\/zjbocon.com\/?p=7286#respond"]}]},{"@type":"WebPage","@id":"https:\/\/zjbocon.com\/?p=7286","url":"https:\/\/zjbocon.com\/?p=7286","name":"ETO Sterilization Re-qualification - ETO STERILIZER","isPartOf":{"@id":"https:\/\/zjbocon.com\/#website"},"primaryImageOfPage":{"@id":"https:\/\/zjbocon.com\/?p=7286#primaryimage"},"image":{"@id":"https:\/\/zjbocon.com\/?p=7286#primaryimage"},"thumbnailUrl":"https:\/\/zjbocon.com\/wp-content\/uploads\/2025\/09\/eto-sterilizer-9.webp","datePublished":"2025-07-29T04:02:12+00:00","dateModified":"2025-10-01T11:30:30+00:00","description":"\u2022\u00a0Minimum annual requirement\u2022 At least once per year, verification data, subsequent re-validation data, and","breadcrumb":{"@id":"https:\/\/zjbocon.com\/?p=7286#breadcrumb"},"inLanguage":"kn","potentialAction":[{"@type":"ReadAction","target":["https:\/\/zjbocon.com\/?p=7286"]}]},{"@type":"ImageObject","inLanguage":"kn","@id":"https:\/\/zjbocon.com\/?p=7286#primaryimage","url":"https:\/\/zjbocon.com\/wp-content\/uploads\/2025\/09\/eto-sterilizer-9.webp","contentUrl":"https:\/\/zjbocon.com\/wp-content\/uploads\/2025\/09\/eto-sterilizer-9.webp","width":1200,"height":1200,"caption":"ETO STERILIZER-HZBOCON"},{"@type":"BreadcrumbList","@id":"https:\/\/zjbocon.com\/?p=7286#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/zjbocon.com\/"},{"@type":"ListItem","position":2,"name":"ETO Sterilization Re-qualification"}]},{"@type":"WebSite","@id":"https:\/\/zjbocon.com\/#website","url":"https:\/\/zjbocon.com\/","name":"ETO STERILIZER","description":"One-stop Solution Supplier of Ethylene Oxide Sterilization","publisher":{"@id":"https:\/\/zjbocon.com\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/zjbocon.com\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"kn"},{"@type":"Organization","@id":"https:\/\/zjbocon.com\/#organization","name":"ETO STERILIZER","url":"https:\/\/zjbocon.com\/","logo":{"@type":"ImageObject","inLanguage":"kn","@id":"https:\/\/zjbocon.com\/#\/schema\/logo\/image\/","url":"https:\/\/zjbocon.com\/wp-content\/uploads\/2024\/10\/logo-1.webp","contentUrl":"https:\/\/zjbocon.com\/wp-content\/uploads\/2024\/10\/logo-1.webp","width":180,"height":60,"caption":"ETO STERILIZER"},"image":{"@id":"https:\/\/zjbocon.com\/#\/schema\/logo\/image\/"},"sameAs":["https:\/\/www.facebook.com\/profile.php?id=100088482339878","https:\/\/x.com\/BoconAnd","https:\/\/www.linkedin.com\/in\/--06a221139\/"]},{"@type":"Person","@id":"https:\/\/zjbocon.com\/#\/schema\/person\/f12be028b8ae9843a4396dcc8012b425","name":"Bocon Technical Team","image":{"@type":"ImageObject","inLanguage":"kn","@id":"https:\/\/secure.gravatar.com\/avatar\/d7a825658be227f26b237e519f8541e05aabc9ff27b8eec4544a233a48c53be0?s=96&d=identicon&r=g","url":"https:\/\/secure.gravatar.com\/avatar\/d7a825658be227f26b237e519f8541e05aabc9ff27b8eec4544a233a48c53be0?s=96&d=identicon&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/d7a825658be227f26b237e519f8541e05aabc9ff27b8eec4544a233a48c53be0?s=96&d=identicon&r=g","caption":"Bocon Technical Team"},"sameAs":["https:\/\/zjbocon.com\/","https:\/\/www.facebook.com\/profile.php?id=100088482339878","https:\/\/www.linkedin.com\/in\/\/hayley--968190269\/"],"url":"https:\/\/zjbocon.com\/?author=234312599"}]}},"jetpack_publicize_connections":[],"jetpack_featured_media_url":"https:\/\/zjbocon.com\/wp-content\/uploads\/2025\/09\/eto-sterilizer-9.webp","uagb_featured_image_src":{"full":["https:\/\/zjbocon.com\/wp-content\/uploads\/2025\/09\/eto-sterilizer-9.webp",1200,1200,false],"thumbnail":["https:\/\/zjbocon.com\/wp-content\/uploads\/2025\/09\/eto-sterilizer-9-150x150.webp",150,150,true],"medium":["https:\/\/zjbocon.com\/wp-content\/uploads\/2025\/09\/eto-sterilizer-9-300x300.webp",300,300,true],"medium_large":["https:\/\/zjbocon.com\/wp-content\/uploads\/2025\/09\/eto-sterilizer-9-768x768.webp",768,768,true],"large":["https:\/\/zjbocon.com\/wp-content\/uploads\/2025\/09\/eto-sterilizer-9-1024x1024.webp",1024,1024,true],"1536x1536":["https:\/\/zjbocon.com\/wp-content\/uploads\/2025\/09\/eto-sterilizer-9.webp",1200,1200,false],"2048x2048":["https:\/\/zjbocon.com\/wp-content\/uploads\/2025\/09\/eto-sterilizer-9.webp",1200,1200,false],"woocommerce_thumbnail":["https:\/\/zjbocon.com\/wp-content\/uploads\/2025\/09\/eto-sterilizer-9-600x600.webp",600,600,true],"woocommerce_single":["https:\/\/zjbocon.com\/wp-content\/uploads\/2025\/09\/eto-sterilizer-9-600x600.webp",600,600,true],"woocommerce_gallery_thumbnail":["https:\/\/zjbocon.com\/wp-content\/uploads\/2025\/09\/eto-sterilizer-9-100x100.webp",100,100,true]},"uagb_author_info":{"display_name":"Bocon Technical Team","author_link":"https:\/\/zjbocon.com\/?author=234312599"},"uagb_comment_info":25,"uagb_excerpt":"ETO Sterilization Re-qualification Requirements 1. Re-qualification Frequency \u2022&nbsp;Minimum annual requirement\u2022 At least once per year, verification data, subsequent re-validation data, [&hellip;]","jetpack_likes_enabled":true,"jetpack_sharing_enabled":true,"jetpack_shortlink":"https:\/\/wp.me\/pgZDV6-1Tw","jetpack-related-posts":[{"id":7268,"url":"https:\/\/zjbocon.com\/?p=7268","url_meta":{"origin":7286,"position":0},"title":"Performance Qualification (PQ)- mpq in eto sterilization","author":"Bocon Technical Team","date":"2025-07-29","format":false,"excerpt":"Methods 1. Bioburden Method: Lethality Confirmation ? Direct Count\/Enumeration Method ? Fraction-Negative Method 2. Overkill Method: Demonstrating ?12-Log Reduction ? Half-Cycle Method ? Cycle Development Method Key Terms Bioburden 12-log reduction D-value Methods Overview 1. Half-Cycle Method (Basic Principle - Run Count) Theoretical initial bioburden: 10? Test Criteria: 1 run\u2026","rel":"","context":"In &quot;Company News&quot;","block_context":{"text":"Company News","link":"https:\/\/zjbocon.com\/?cat=133125"},"img":{"alt_text":"","src":"https:\/\/i0.wp.com\/zjbocon.com\/wp-content\/uploads\/2025\/09\/ethylene-oxide-sterilization-57-scaled.webp?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/zjbocon.com\/wp-content\/uploads\/2025\/09\/ethylene-oxide-sterilization-57-scaled.webp?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/zjbocon.com\/wp-content\/uploads\/2025\/09\/ethylene-oxide-sterilization-57-scaled.webp?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/zjbocon.com\/wp-content\/uploads\/2025\/09\/ethylene-oxide-sterilization-57-scaled.webp?resize=700%2C400&ssl=1 2x, https:\/\/i0.wp.com\/zjbocon.com\/wp-content\/uploads\/2025\/09\/ethylene-oxide-sterilization-57-scaled.webp?resize=1050%2C600&ssl=1 3x, https:\/\/i0.wp.com\/zjbocon.com\/wp-content\/uploads\/2025\/09\/ethylene-oxide-sterilization-57-scaled.webp?resize=1400%2C800&ssl=1 4x"},"classes":[]},{"id":9080,"url":"https:\/\/zjbocon.com\/?p=9080","url_meta":{"origin":7286,"position":1},"title":"Essential Utilities and Service Requirements for ETO Sterilizers","author":"Bocon Technical Team","date":"2026-01-20","format":false,"excerpt":"The successful operation of an Ethylene Oxide (ETO) sterilizer requires more than just the machine itself; it demands a robust infrastructure of essential utilities, safety systems, and ongoing technical support. Ensuring these requirements are met is critical for process efficiency, operator safety, and regulatory compliance (such as ISO 11135). Below\u2026","rel":"","context":"In &quot;Company News&quot;","block_context":{"text":"Company News","link":"https:\/\/zjbocon.com\/?cat=133125"},"img":{"alt_text":"","src":"https:\/\/i0.wp.com\/zjbocon.com\/wp-content\/uploads\/2024\/11\/eto-sterilizer-hzbocon-4.png?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/zjbocon.com\/wp-content\/uploads\/2024\/11\/eto-sterilizer-hzbocon-4.png?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/zjbocon.com\/wp-content\/uploads\/2024\/11\/eto-sterilizer-hzbocon-4.png?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/zjbocon.com\/wp-content\/uploads\/2024\/11\/eto-sterilizer-hzbocon-4.png?resize=700%2C400&ssl=1 2x, https:\/\/i0.wp.com\/zjbocon.com\/wp-content\/uploads\/2024\/11\/eto-sterilizer-hzbocon-4.png?resize=1050%2C600&ssl=1 3x"},"classes":[]},{"id":2076,"url":"https:\/\/zjbocon.com\/?p=2076","url_meta":{"origin":7286,"position":2},"title":"PQ in Ethylene oxide sterilization chamber","author":"Bocon Technical Team","date":"2024-10-31","format":false,"excerpt":"PQ is the stage of validation that uses Ethylene oxide sterilization chamber to demonstrate that the Ethylene oxide sterilization equipment consistently operates in accordance with predetermined acceptance criteria and the process yields a product that is sterile and meets the specified requirements.","rel":"","context":"In &quot;ETO STERILIZER&quot;","block_context":{"text":"ETO STERILIZER","link":"https:\/\/zjbocon.com\/?cat=133124"},"img":{"alt_text":"","src":"https:\/\/i0.wp.com\/zjbocon.com\/wp-content\/uploads\/2025\/09\/eto-sterilizer-1.webp?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/zjbocon.com\/wp-content\/uploads\/2025\/09\/eto-sterilizer-1.webp?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/zjbocon.com\/wp-content\/uploads\/2025\/09\/eto-sterilizer-1.webp?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/zjbocon.com\/wp-content\/uploads\/2025\/09\/eto-sterilizer-1.webp?resize=700%2C400&ssl=1 2x, https:\/\/i0.wp.com\/zjbocon.com\/wp-content\/uploads\/2025\/09\/eto-sterilizer-1.webp?resize=1050%2C600&ssl=1 3x"},"classes":[]},{"id":7277,"url":"https:\/\/zjbocon.com\/?p=7277","url_meta":{"origin":7286,"position":3},"title":"Performance Qualification(pq)-ppq in eo sterilization","author":"Bocon Technical Team","date":"2025-07-29","format":false,"excerpt":"Physical Performance Qualification (PPQ)\u2022 It shall be demonstrated that all specified acceptance criteria are reproducible throughout the entire process.How many runs should the PPQ process perform?\u2022 To demonstrate process reproducibility, at least 3 runs are required;\u2022 If 3 half-cycles were run during the MPQ process, then at least 1 additional\u2026","rel":"","context":"In &quot;Company News&quot;","block_context":{"text":"Company News","link":"https:\/\/zjbocon.com\/?cat=133125"},"img":{"alt_text":"","src":"https:\/\/i0.wp.com\/zjbocon.com\/wp-content\/uploads\/2025\/09\/eto-sterilizer-11.webp?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/zjbocon.com\/wp-content\/uploads\/2025\/09\/eto-sterilizer-11.webp?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/zjbocon.com\/wp-content\/uploads\/2025\/09\/eto-sterilizer-11.webp?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/zjbocon.com\/wp-content\/uploads\/2025\/09\/eto-sterilizer-11.webp?resize=700%2C400&ssl=1 2x, https:\/\/i0.wp.com\/zjbocon.com\/wp-content\/uploads\/2025\/09\/eto-sterilizer-11.webp?resize=1050%2C600&ssl=1 3x"},"classes":[]},{"id":2332,"url":"https:\/\/zjbocon.com\/?p=2332","url_meta":{"origin":7286,"position":4},"title":"Terms and definitions of eto gas sterilization","author":"Bocon Technical Team","date":"2024-11-26","format":false,"excerpt":"For the purposes of this document, the following terms and definitions apply in ethylene oxide sterilization 3.1 Aeration part of the eto gas sterilization process during which ethylene oxide and\/or its reaction products desorb from the medical device until predetermined levels are reached \u00a0 Note 1 to entry: This can\u2026","rel":"","context":"In &quot;ETO STERILIZER&quot;","block_context":{"text":"ETO STERILIZER","link":"https:\/\/zjbocon.com\/?cat=133124"},"img":{"alt_text":"","src":"https:\/\/i0.wp.com\/zjbocon.com\/wp-content\/uploads\/2025\/09\/eto-sterilizer-11.webp?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/zjbocon.com\/wp-content\/uploads\/2025\/09\/eto-sterilizer-11.webp?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/zjbocon.com\/wp-content\/uploads\/2025\/09\/eto-sterilizer-11.webp?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/zjbocon.com\/wp-content\/uploads\/2025\/09\/eto-sterilizer-11.webp?resize=700%2C400&ssl=1 2x, https:\/\/i0.wp.com\/zjbocon.com\/wp-content\/uploads\/2025\/09\/eto-sterilizer-11.webp?resize=1050%2C600&ssl=1 3x"},"classes":[]},{"id":2138,"url":"https:\/\/zjbocon.com\/?p=2138","url_meta":{"origin":7286,"position":5},"title":"ETO Sterilization Chamber Testing","author":"Bocon Technical Team","date":"2024-11-07","format":false,"excerpt":"The temperature setting range of the ETO Sterilization Chamber should be between 30-60\u00b0C. It is recommended to perform temperature distribution testing of the sterilizer's internal surface and temperature and humidity distribution testing inside the sterilization chamber to ensure the effectiveness of the heating and humidifying systems.","rel":"","context":"In &quot;ETO STERILIZER&quot;","block_context":{"text":"ETO STERILIZER","link":"https:\/\/zjbocon.com\/?cat=133124"},"img":{"alt_text":"","src":"https:\/\/i0.wp.com\/zjbocon.com\/wp-content\/uploads\/2025\/09\/cropped-cropped-hzbocon.png?resize=350%2C200&ssl=1","width":350,"height":200},"classes":[]}],"_links":{"self":[{"href":"https:\/\/zjbocon.com\/index.php?rest_route=\/wp\/v2\/posts\/7286","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/zjbocon.com\/index.php?rest_route=\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/zjbocon.com\/index.php?rest_route=\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/zjbocon.com\/index.php?rest_route=\/wp\/v2\/users\/234312599"}],"replies":[{"embeddable":true,"href":"https:\/\/zjbocon.com\/index.php?rest_route=%2Fwp%2Fv2%2Fcomments&post=7286"}],"version-history":[{"count":12,"href":"https:\/\/zjbocon.com\/index.php?rest_route=\/wp\/v2\/posts\/7286\/revisions"}],"predecessor-version":[{"id":8613,"href":"https:\/\/zjbocon.com\/index.php?rest_route=\/wp\/v2\/posts\/7286\/revisions\/8613"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/zjbocon.com\/index.php?rest_route=\/wp\/v2\/media\/8487"}],"wp:attachment":[{"href":"https:\/\/zjbocon.com\/index.php?rest_route=%2Fwp%2Fv2%2Fmedia&parent=7286"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/zjbocon.com\/index.php?rest_route=%2Fwp%2Fv2%2Fcategories&post=7286"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/zjbocon.com\/index.php?rest_route=%2Fwp%2Fv2%2Ftags&post=7286"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}