{"id":2308,"date":"2024-11-22T10:58:43","date_gmt":"2024-11-22T02:58:43","guid":{"rendered":"https:\/\/zjbocon.com\/?p=2308"},"modified":"2026-02-09T09:59:17","modified_gmt":"2026-02-09T01:59:17","slug":"request-for-eto-gas-sterilizer-manufacturer","status":"publish","type":"post","link":"https:\/\/zjbocon.com\/?p=2308","title":{"rendered":"Request For Eto Gas Sterilizer Manufacturer"},"content":{"rendered":"\n<div class=\"wp-block-uagb-image uagb-block-1607f3f6 wp-block-uagb-image--layout-default wp-block-uagb-image--effect-static wp-block-uagb-image--align-none\"><figure class=\"wp-block-uagb-image__figure\"><img loading=\"lazy\" decoding=\"async\" src=\"https:\/\/zjbocon.com\/wp-content\/uploads\/2025\/11\/eto-sterilzer-1024x452.webp\" alt=\"\" class=\"uag-image-8783\" width=\"1024\" height=\"452\" title=\"eto sterilzer\" role=\"img\" \><\/figure><\/div>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"h-2-1-appearance-and-structure-request-for-eto-gas-sterilizer-manufacturer\">2.1 Eto 가스 멸균기 제조사의 외관 및 구조 요구 사항<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">2.1.1 전체적인 형태는 정확하고 표면이 매끄럽고 깨끗하며 색상이 균일해야 한다. 거친 부분, 날카로운 모서리, 균열, 눈에 띄는 긁힘 또는 고르지 못한 부분이 없어야 합니다.<br>2.1.2 모든 외부 텍스트, 그래픽 및 기호는 정확하고 내구성 있는 표시와 함께 명확하게 인쇄되어야 합니다.<br>2.1.3 패스너는 단단히 설치되어야 합니다. 모든 제어 스위치와 조정 손잡이(또는 버튼)는 장애물 없이 원활하고 안정적으로 작동해야 합니다.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"h-2-2-dimensions-request-for-eto-gas-sterilizer-manufacturer\">2.2 Eto 가스 멸균기 제조업체에 대한 치수 요청<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">2.2.1 The sterilization chamber should adhere to the design dimensions in millimeters, with a tolerance of \u00b11%.<br>2.2.2 멸균 부하 주변의 부작용을 완화하기 위해 챔버는 가열된 표면에서 최소 15mm, 가열되지 않은 표면에서 30mm의 간격을 유지해야 합니다.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"h-2-3-materials-and-construction-request-for-eto-gas-sterilizer-manufacturer\">2.3 Eto 가스 멸균기 제조업체에 대한 자재 및 시공 요청<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">2.3.1 일반 요구사항<br>2.3.1.1 제조업체는 사용자가 선택할 수 있는 최대 작동 압력을 지정해야 합니다.<br>2.3.1.2 챔버 내부 표면은 섹션 2.13.1의 요구 사항을 충족하면서 부분적으로 또는 완전히 가열되어야 합니다.<br>2.3.1.3 작동 조건에서 산화에틸렌(EO)에 노출된 재료는 다음을 충족해야 합니다.<br>a) EO 가스 및 그 혼합물로 인한 부식을 방지합니다.<br>b) EO 또는 알려진 오염물질과 반응하지 않습니다.<br>c) EO 중합이나 분해를 촉진하지 마십시오.<br>건설에는 스테인레스 스틸 또는 부식 방지 저탄소 강철을 권장합니다.<br>2.3.1.4 내부 압력 부품에는 처리되지 않은 저탄소강을 사용해서는 안 됩니다.<br>2.3.2 테스트 포트<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">2.3.2.1 온도 포트<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Chambers ? 5 m\u00b3 must have at least 10 temperature ports. For chambers &gt; 5 m\u00b3, add one port for each additional cubic meter. Chambers ? 10 m\u00b3 require a minimum of 20 ports.<br>Each port must maintain at least 100 mm of clearance from internal or external obstacles and conform to GB\/T7307-2001 standards for external threads.<br>2.3.2.2 진공 테스트 포트<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">최소한 하나의 진공 테스트 포트가 안전하게 설치되어 챔버에 직접 연결되어야 합니다. 포트는 지정된 치수 및 안전 요구 사항을 충족해야 합니다.<br>2.3.2.3 샘플링 포트<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">챔버에는 진공 테스트 포트와 동일한 표준을 충족하는 EO 농도 또는 상대 습도를 측정하기 위한 샘플링 포트가 하나 이상 포함되어야 합니다.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"h-2-4-components-pipes-and-fittings-of-eto-sterilizer-manufacturer\">2.4 Eto 살균제 제조업체의 구성 요소, 파이프 및 피팅<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">2.4.1 구성요소<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">챔버에 연결된 모든 구성 요소는 일반 재료 요구 사항을 준수해야 하며 EO에 닿을 경우 쉽게 청소할 수 있어야 합니다.<br>2.4.2 배관 및 부속품<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">액체 멸균기와 접촉하는 배관은 이음매가 없어야 하며 누출을 방지하도록 설계되어야 합니다. 유지보수를 위해 분해가 필요한 경우를 제외하고 조인트는 용접되어야 합니다.<br>2.5 도어, 컨트롤러 및 인터록<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"h-2-5-1-door-seals\">2.5.1 도어 씰<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">도어는 자재 요구 사항을 준수하는 씰을 사용해야 하며 쉽게 청소하거나 교체할 수 있어야 합니다.<br>2.5.2 자동 및 수동 도어 작동<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">정전이 발생하더라도 자동문은 밀봉된 상태로 유지되어 안전을 보장해야 합니다. 수동 도어는 작동하는 데 150N 이상의 힘이 필요하지 않아야 합니다.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"h-2-6-control-valves\">2.6 제어 밸브<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">밸브는 파이프를 분리하지 않고도 유지 관리가 가능해야 하며 지정된 효율의 사전 필터를 포함해야 합니다.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"h-2-7-utilities\">2.7 유틸리티<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">2.7.1 물<br>분무된 물을 직접 주입해서는 안 됩니다.<br>2.7.2 증기<br>가습을 위한 증기 압력은 50kPa를 초과해서는 안 됩니다.<br>2.7.3 공기 및 불활성 가스<br>공기는 건조하고 기름이 없어야 하며 오염을 방지하기 위해 여과되어야 합니다.<br><\/p>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"h-if-you-want-to-know-more-about-ethylene-oxide-sterilization\">에틸렌옥사이드 멸균에 대해 더 알고 싶으시다면<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">핸드폰:<a href=\"https:\/\/wa.me\/8619975258603\">+8619975258603<\/a><\/p>\n\n\n\n<p class=\"wp-block-paragraph\">이메일:<a href=\"mailto:hayley@hzbocon.com\">hayley@hzbocon.com<\/a><\/p>\n\n\n\n<p class=\"wp-block-paragraph\">현지 사이트: 중국 절강성 항저우시 샤사구 차이통 중신 1202호<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">웹사이트:<a href=\"https:\/\/www.hzbocon.com\/\">hzbocon.com<\/a><a href=\"https:\/\/zjbocon.com\/\">&nbsp;zjbocon.com<\/a><\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><\/p>\n","protected":false},"excerpt":{"rendered":"<p>2.1.1 전체적인 형태는 정확하고 표면이 매끄럽고 깨끗하며 색상이 균일해야 한다. 거친 부분, 날카로운 모서리, 균열, 눈에 띄는 긁힘 또는 고르지 못한 부분이 없어야 합니다.<br \>\n2.1.2 All external text, graphics, and symbols must be printed clearly, with precise and durable markings.<br \>\n2.1.3 Fasteners must be securely installed. All control switches and adjustment knobs (or buttons) should operate smoothly and reliably without obstructions.<\/p>\n","protected":false},"author":234312599,"featured_media":8477,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_uag_custom_page_level_css":"","site-sidebar-layout":"default","site-content-layout":"","ast-site-content-layout":"default","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","ast-disable-related-posts":"","theme-transparent-header-meta":"","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"set","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"_jetpack_newsletter_access":"","_jetpack_dont_email_post_to_subs":false,"_jetpack_newsletter_tier_id":0,"_jetpack_memberships_contains_paywalled_content":false,"_jetpack_feature_clip_id":0,"_jetpack_memberships_contains_paid_content":false,"footnotes":"","jetpack_publicize_message":"","jetpack_publicize_feature_enabled":true,"jetpack_social_post_already_shared":false,"jetpack_social_options":{"image_generator_settings":{"template":"highway","enabled":false},"version":2},"jetpack_post_was_ever_published":false},"categories":[133124],"tags":[],"class_list":["post-2308","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-eto-sterilizer"],"yoast_head":"<!-- This site is optimized with the Yoast SEO Premium plugin v27.2 (Yoast SEO v28.0) - https:\/\/yoast.com\/product\/yoast-seo-premium-wordpress\/ -->\n<title>ETO 가스 멸균기 제조업체에 대한 요청 - ETO STERILIZER<\/title>\n<meta name=\"description\" content=\"2.1 Appearance and Structure of Eto Gas Sterilizer Manufacturer The overall shape should be precise, with smooth, clean\" \>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \>\n<link rel=\"canonical\" href=\"https:\/\/zjbocon.com\/?p=2308\" \>\n<meta property=\"og:locale\" content=\"ko_KR\" \>\n<meta property=\"og:type\" content=\"article\" \>\n<meta property=\"og:title\" content=\"Request For Eto Gas Sterilizer Manufacturer\" \>\n<meta property=\"og:description\" content=\"2.1 Appearance and Structure of Eto Gas Sterilizer Manufacturer The overall shape should be precise, with smooth, clean\" \>\n<meta property=\"og:url\" content=\"https:\/\/zjbocon.com\/?p=2308\" \>\n<meta property=\"og:site_name\" content=\"ETO STERILIZER\" \>\n<meta property=\"article:publisher\" content=\"https:\/\/www.facebook.com\/profile.php?id=100088482339878\" \>\n<meta property=\"article:author\" content=\"https:\/\/www.facebook.com\/profile.php?id=100088482339878\" \>\n<meta property=\"article:published_time\" content=\"2024-11-22T02:58:43+00:00\" \>\n<meta property=\"article:modified_time\" content=\"2026-02-09T01:59:17+00:00\" \>\n<meta property=\"og:image\" content=\"https:\/\/zjbocon.com\/wp-content\/uploads\/2025\/09\/eto-sterilizer-11.webp\" \>\n\t<meta property=\"og:image:width\" content=\"1200\" \>\n\t<meta property=\"og:image:height\" content=\"1200\" \>\n\t<meta property=\"og:image:type\" content=\"image\/webp\" \>\n<meta name=\"author\" content=\"Bocon Technical Team\" \>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \>\n<meta name=\"twitter:creator\" content=\"@BoconAnd\" \>\n<meta name=\"twitter:site\" content=\"@BoconAnd\" \>\n<meta name=\"twitter:label1\" content=\"Written by\" \>\n\t<meta name=\"twitter:data1\" content=\"Bocon Technical Team\" \>\n\t<meta name=\"twitter:label2\" content=\"Est. reading time\" \>\n\t<meta name=\"twitter:data2\" content=\"3 minutes\" \>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\\\/\\\/zjbocon.com\\\/?p=2308#article\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/zjbocon.com\\\/?p=2308\"},\"author\":{\"name\":\"Bocon Technical Team\",\"@id\":\"https:\\\/\\\/zjbocon.com\\\/#\\\/schema\\\/person\\\/f12be028b8ae9843a4396dcc8012b425\"},\"headline\":\"Request For Eto Gas Sterilizer Manufacturer\",\"datePublished\":\"2024-11-22T02:58:43+00:00\",\"dateModified\":\"2026-02-09T01:59:17+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/zjbocon.com\\\/?p=2308\"},\"wordCount\":512,\"commentCount\":0,\"publisher\":{\"@id\":\"https:\\\/\\\/zjbocon.com\\\/#organization\"},\"image\":{\"@id\":\"https:\\\/\\\/zjbocon.com\\\/?p=2308#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/zjbocon.com\\\/wp-content\\\/uploads\\\/2025\\\/09\\\/eto-sterilizer-11.webp\",\"articleSection\":[\"ETO STERILIZER\"],\"inLanguage\":\"ko-KR\",\"potentialAction\":[{\"@type\":\"CommentAction\",\"name\":\"Comment\",\"target\":[\"https:\\\/\\\/zjbocon.com\\\/?p=2308#respond\"]}]},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/zjbocon.com\\\/?p=2308\",\"url\":\"https:\\\/\\\/zjbocon.com\\\/?p=2308\",\"name\":\"Request For Eto Gas Sterilizer Manufacturer - ETO STERILIZER\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/zjbocon.com\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/zjbocon.com\\\/?p=2308#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/zjbocon.com\\\/?p=2308#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/zjbocon.com\\\/wp-content\\\/uploads\\\/2025\\\/09\\\/eto-sterilizer-11.webp\",\"datePublished\":\"2024-11-22T02:58:43+00:00\",\"dateModified\":\"2026-02-09T01:59:17+00:00\",\"description\":\"2.1 Appearance and Structure of Eto Gas Sterilizer Manufacturer The overall shape should be precise, with smooth, clean\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/zjbocon.com\\\/?p=2308#breadcrumb\"},\"inLanguage\":\"ko-KR\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/zjbocon.com\\\/?p=2308\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"ko-KR\",\"@id\":\"https:\\\/\\\/zjbocon.com\\\/?p=2308#primaryimage\",\"url\":\"https:\\\/\\\/zjbocon.com\\\/wp-content\\\/uploads\\\/2025\\\/09\\\/eto-sterilizer-11.webp\",\"contentUrl\":\"https:\\\/\\\/zjbocon.com\\\/wp-content\\\/uploads\\\/2025\\\/09\\\/eto-sterilizer-11.webp\",\"width\":1200,\"height\":1200},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/zjbocon.com\\\/?p=2308#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/zjbocon.com\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Request For Eto Gas Sterilizer Manufacturer\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/zjbocon.com\\\/#website\",\"url\":\"https:\\\/\\\/zjbocon.com\\\/\",\"name\":\"ETO STERILIZER\",\"description\":\"One-stop Solution Supplier of Ethylene Oxide Sterilization\",\"publisher\":{\"@id\":\"https:\\\/\\\/zjbocon.com\\\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/zjbocon.com\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"ko-KR\"},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/zjbocon.com\\\/#organization\",\"name\":\"ETO STERILIZER\",\"url\":\"https:\\\/\\\/zjbocon.com\\\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"ko-KR\",\"@id\":\"https:\\\/\\\/zjbocon.com\\\/#\\\/schema\\\/logo\\\/image\\\/\",\"url\":\"https:\\\/\\\/zjbocon.com\\\/wp-content\\\/uploads\\\/2024\\\/10\\\/logo-1.webp\",\"contentUrl\":\"https:\\\/\\\/zjbocon.com\\\/wp-content\\\/uploads\\\/2024\\\/10\\\/logo-1.webp\",\"width\":180,\"height\":60,\"caption\":\"ETO STERILIZER\"},\"image\":{\"@id\":\"https:\\\/\\\/zjbocon.com\\\/#\\\/schema\\\/logo\\\/image\\\/\"},\"sameAs\":[\"https:\\\/\\\/www.facebook.com\\\/profile.php?id=100088482339878\",\"https:\\\/\\\/x.com\\\/BoconAnd\",\"https:\\\/\\\/www.linkedin.com\\\/in\\\/--06a221139\\\/\"]},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/zjbocon.com\\\/#\\\/schema\\\/person\\\/f12be028b8ae9843a4396dcc8012b425\",\"name\":\"Bocon Technical Team\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"ko-KR\",\"@id\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/d7a825658be227f26b237e519f8541e05aabc9ff27b8eec4544a233a48c53be0?s=96&d=identicon&r=g\",\"url\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/d7a825658be227f26b237e519f8541e05aabc9ff27b8eec4544a233a48c53be0?s=96&d=identicon&r=g\",\"contentUrl\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/d7a825658be227f26b237e519f8541e05aabc9ff27b8eec4544a233a48c53be0?s=96&d=identicon&r=g\",\"caption\":\"Bocon Technical Team\"},\"sameAs\":[\"https:\\\/\\\/zjbocon.com\\\/\",\"https:\\\/\\\/www.facebook.com\\\/profile.php?id=100088482339878\",\"https:\\\/\\\/www.linkedin.com\\\/in\\\/\\\/hayley--968190269\\\/\"],\"url\":\"https:\\\/\\\/zjbocon.com\\\/?author=234312599\"}]}<\/script>\n<!-- \/ Yoast SEO Premium plugin. -->","yoast_head_json":{"title":"Request For Eto Gas Sterilizer Manufacturer - ETO STERILIZER","description":"2.1 Appearance and Structure of Eto Gas Sterilizer Manufacturer The overall shape should be precise, with smooth, clean","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/zjbocon.com\/?p=2308","og_locale":"ko_KR","og_type":"article","og_title":"Request For Eto Gas Sterilizer Manufacturer","og_description":"2.1 Appearance and Structure of Eto Gas Sterilizer Manufacturer The overall shape should be precise, with smooth, clean","og_url":"https:\/\/zjbocon.com\/?p=2308","og_site_name":"ETO STERILIZER","article_publisher":"https:\/\/www.facebook.com\/profile.php?id=100088482339878","article_author":"https:\/\/www.facebook.com\/profile.php?id=100088482339878","article_published_time":"2024-11-22T02:58:43+00:00","article_modified_time":"2026-02-09T01:59:17+00:00","og_image":[{"width":1200,"height":1200,"url":"https:\/\/zjbocon.com\/wp-content\/uploads\/2025\/09\/eto-sterilizer-11.webp","type":"image\/webp"}],"author":"Bocon Technical Team","twitter_card":"summary_large_image","twitter_creator":"@BoconAnd","twitter_site":"@BoconAnd","twitter_misc":{"Written by":"Bocon Technical Team","Est. reading time":"3 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/zjbocon.com\/?p=2308#article","isPartOf":{"@id":"https:\/\/zjbocon.com\/?p=2308"},"author":{"name":"Bocon Technical Team","@id":"https:\/\/zjbocon.com\/#\/schema\/person\/f12be028b8ae9843a4396dcc8012b425"},"headline":"Request For Eto Gas Sterilizer Manufacturer","datePublished":"2024-11-22T02:58:43+00:00","dateModified":"2026-02-09T01:59:17+00:00","mainEntityOfPage":{"@id":"https:\/\/zjbocon.com\/?p=2308"},"wordCount":512,"commentCount":0,"publisher":{"@id":"https:\/\/zjbocon.com\/#organization"},"image":{"@id":"https:\/\/zjbocon.com\/?p=2308#primaryimage"},"thumbnailUrl":"https:\/\/zjbocon.com\/wp-content\/uploads\/2025\/09\/eto-sterilizer-11.webp","articleSection":["ETO STERILIZER"],"inLanguage":"ko-KR","potentialAction":[{"@type":"CommentAction","name":"Comment","target":["https:\/\/zjbocon.com\/?p=2308#respond"]}]},{"@type":"WebPage","@id":"https:\/\/zjbocon.com\/?p=2308","url":"https:\/\/zjbocon.com\/?p=2308","name":"Request For Eto Gas Sterilizer Manufacturer - ETO STERILIZER","isPartOf":{"@id":"https:\/\/zjbocon.com\/#website"},"primaryImageOfPage":{"@id":"https:\/\/zjbocon.com\/?p=2308#primaryimage"},"image":{"@id":"https:\/\/zjbocon.com\/?p=2308#primaryimage"},"thumbnailUrl":"https:\/\/zjbocon.com\/wp-content\/uploads\/2025\/09\/eto-sterilizer-11.webp","datePublished":"2024-11-22T02:58:43+00:00","dateModified":"2026-02-09T01:59:17+00:00","description":"2.1 Appearance and Structure of Eto Gas Sterilizer Manufacturer The overall shape should be precise, with smooth, clean","breadcrumb":{"@id":"https:\/\/zjbocon.com\/?p=2308#breadcrumb"},"inLanguage":"ko-KR","potentialAction":[{"@type":"ReadAction","target":["https:\/\/zjbocon.com\/?p=2308"]}]},{"@type":"ImageObject","inLanguage":"ko-KR","@id":"https:\/\/zjbocon.com\/?p=2308#primaryimage","url":"https:\/\/zjbocon.com\/wp-content\/uploads\/2025\/09\/eto-sterilizer-11.webp","contentUrl":"https:\/\/zjbocon.com\/wp-content\/uploads\/2025\/09\/eto-sterilizer-11.webp","width":1200,"height":1200},{"@type":"BreadcrumbList","@id":"https:\/\/zjbocon.com\/?p=2308#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/zjbocon.com\/"},{"@type":"ListItem","position":2,"name":"Request For Eto Gas Sterilizer Manufacturer"}]},{"@type":"WebSite","@id":"https:\/\/zjbocon.com\/#website","url":"https:\/\/zjbocon.com\/","name":"ETO STERILIZER","description":"One-stop Solution Supplier of Ethylene Oxide Sterilization","publisher":{"@id":"https:\/\/zjbocon.com\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/zjbocon.com\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"ko-KR"},{"@type":"Organization","@id":"https:\/\/zjbocon.com\/#organization","name":"ETO STERILIZER","url":"https:\/\/zjbocon.com\/","logo":{"@type":"ImageObject","inLanguage":"ko-KR","@id":"https:\/\/zjbocon.com\/#\/schema\/logo\/image\/","url":"https:\/\/zjbocon.com\/wp-content\/uploads\/2024\/10\/logo-1.webp","contentUrl":"https:\/\/zjbocon.com\/wp-content\/uploads\/2024\/10\/logo-1.webp","width":180,"height":60,"caption":"ETO STERILIZER"},"image":{"@id":"https:\/\/zjbocon.com\/#\/schema\/logo\/image\/"},"sameAs":["https:\/\/www.facebook.com\/profile.php?id=100088482339878","https:\/\/x.com\/BoconAnd","https:\/\/www.linkedin.com\/in\/--06a221139\/"]},{"@type":"Person","@id":"https:\/\/zjbocon.com\/#\/schema\/person\/f12be028b8ae9843a4396dcc8012b425","name":"Bocon Technical Team","image":{"@type":"ImageObject","inLanguage":"ko-KR","@id":"https:\/\/secure.gravatar.com\/avatar\/d7a825658be227f26b237e519f8541e05aabc9ff27b8eec4544a233a48c53be0?s=96&d=identicon&r=g","url":"https:\/\/secure.gravatar.com\/avatar\/d7a825658be227f26b237e519f8541e05aabc9ff27b8eec4544a233a48c53be0?s=96&d=identicon&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/d7a825658be227f26b237e519f8541e05aabc9ff27b8eec4544a233a48c53be0?s=96&d=identicon&r=g","caption":"Bocon Technical Team"},"sameAs":["https:\/\/zjbocon.com\/","https:\/\/www.facebook.com\/profile.php?id=100088482339878","https:\/\/www.linkedin.com\/in\/\/hayley--968190269\/"],"url":"https:\/\/zjbocon.com\/?author=234312599"}]}},"jetpack_publicize_connections":[],"jetpack_featured_media_url":"https:\/\/zjbocon.com\/wp-content\/uploads\/2025\/09\/eto-sterilizer-11.webp","uagb_featured_image_src":{"full":["https:\/\/zjbocon.com\/wp-content\/uploads\/2025\/09\/eto-sterilizer-11.webp",1200,1200,false],"thumbnail":["https:\/\/zjbocon.com\/wp-content\/uploads\/2025\/09\/eto-sterilizer-11-150x150.webp",150,150,true],"medium":["https:\/\/zjbocon.com\/wp-content\/uploads\/2025\/09\/eto-sterilizer-11-300x300.webp",300,300,true],"medium_large":["https:\/\/zjbocon.com\/wp-content\/uploads\/2025\/09\/eto-sterilizer-11-768x768.webp",768,768,true],"large":["https:\/\/zjbocon.com\/wp-content\/uploads\/2025\/09\/eto-sterilizer-11-1024x1024.webp",1024,1024,true],"1536x1536":["https:\/\/zjbocon.com\/wp-content\/uploads\/2025\/09\/eto-sterilizer-11.webp",1200,1200,false],"2048x2048":["https:\/\/zjbocon.com\/wp-content\/uploads\/2025\/09\/eto-sterilizer-11.webp",1200,1200,false],"woocommerce_thumbnail":["https:\/\/zjbocon.com\/wp-content\/uploads\/2025\/09\/eto-sterilizer-11-600x600.webp",600,600,true],"woocommerce_single":["https:\/\/zjbocon.com\/wp-content\/uploads\/2025\/09\/eto-sterilizer-11-600x600.webp",600,600,true],"woocommerce_gallery_thumbnail":["https:\/\/zjbocon.com\/wp-content\/uploads\/2025\/09\/eto-sterilizer-11-100x100.webp",100,100,true]},"uagb_author_info":{"display_name":"Bocon Technical Team","author_link":"https:\/\/zjbocon.com\/?author=234312599"},"uagb_comment_info":29,"uagb_excerpt":"2.1.1 The overall shape should be precise, with smooth, clean surfaces and uniform color. There should be no burrs, sharp edges, cracks, visible scratches, or unevenness. 2.1.2 All external text, graphics, and symbols must be printed clearly, with precise and durable markings. 2.1.3 Fasteners must be securely installed. All control switches and adjustment knobs (or&hellip;","jetpack_likes_enabled":true,"jetpack_sharing_enabled":true,"jetpack_shortlink":"https:\/\/wp.me\/pgZDV6-Be","jetpack-related-posts":[{"id":2492,"url":"https:\/\/zjbocon.com\/?p=2492","url_meta":{"origin":2308,"position":0},"title":"Understanding ETO Sterilizer Performance: Keys to Efficiency","author":"Bocon Technical Team","date":"2024-12-24","format":false,"excerpt":"3.4.1 eto sterilizer machine Temperature Setting Range The temperature setting range for the eto sterilizer is: 30 to 70\u00b0C","rel":"","context":"In &quot;Company News&quot;","block_context":{"text":"Company News","link":"https:\/\/zjbocon.com\/?cat=133125"},"img":{"alt_text":"","src":"https:\/\/i0.wp.com\/zjbocon.com\/wp-content\/uploads\/2025\/09\/eto-sterilizer-1.webp?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/zjbocon.com\/wp-content\/uploads\/2025\/09\/eto-sterilizer-1.webp?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/zjbocon.com\/wp-content\/uploads\/2025\/09\/eto-sterilizer-1.webp?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/zjbocon.com\/wp-content\/uploads\/2025\/09\/eto-sterilizer-1.webp?resize=700%2C400&ssl=1 2x, https:\/\/i0.wp.com\/zjbocon.com\/wp-content\/uploads\/2025\/09\/eto-sterilizer-1.webp?resize=1050%2C600&ssl=1 3x"},"classes":[]},{"id":2880,"url":"https:\/\/zjbocon.com\/?p=2880","url_meta":{"origin":2308,"position":1},"title":"eto sterile machine manufacturer in china","author":"Bocon Technical Team","date":"2025-01-16","format":false,"excerpt":"Hangzhou Bocon Mechanical and Electrical Equipment Co., Ltd( eto sterile machine manufacturer in china) was established in 2006. The office is located in Hangzhou; And the factory is situated in Jiaxing. HZBOCON primarily engages in the research and development, production, and sales of eto sterile machine, the main advantage is\u2026","rel":"","context":"In &quot;Company News&quot;","block_context":{"text":"Company News","link":"https:\/\/zjbocon.com\/?cat=133125"},"img":{"alt_text":"","src":"https:\/\/i0.wp.com\/zjbocon.com\/wp-content\/uploads\/2025\/09\/cropped-cropped-hzbocon.png?resize=350%2C200&ssl=1","width":350,"height":200},"classes":[]},{"id":2094,"url":"https:\/\/zjbocon.com\/?p=2094","url_meta":{"origin":2308,"position":2},"title":"ETO Sterilizer Manufacturer-HZBOCON","author":"Bocon Technical Team","date":"2024-11-04","format":false,"excerpt":"Hangzhou Bocon Mechanical and Electrical Equipment Co., Ltd., commonly referred to as HZBOCON, stands out as a dedicated Ethylene Oxide (EO\/ETO) sterilizer manufacturer. Established in 2006, HZBOCON has committed itself to the design, development, and manufacturing of EO sterilization equipment, catering to a wide array of industries that require effective\u2026","rel":"","context":"In &quot;ETO STERILIZER&quot;","block_context":{"text":"ETO STERILIZER","link":"https:\/\/zjbocon.com\/?cat=133124"},"img":{"alt_text":"","src":"https:\/\/i0.wp.com\/zjbocon.com\/wp-content\/uploads\/2024\/11\/eto-sterilizer-hzbocon-4.png?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/zjbocon.com\/wp-content\/uploads\/2024\/11\/eto-sterilizer-hzbocon-4.png?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/zjbocon.com\/wp-content\/uploads\/2024\/11\/eto-sterilizer-hzbocon-4.png?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/zjbocon.com\/wp-content\/uploads\/2024\/11\/eto-sterilizer-hzbocon-4.png?resize=700%2C400&ssl=1 2x, https:\/\/i0.wp.com\/zjbocon.com\/wp-content\/uploads\/2024\/11\/eto-sterilizer-hzbocon-4.png?resize=1050%2C600&ssl=1 3x"},"classes":[]},{"id":2515,"url":"https:\/\/zjbocon.com\/?p=2515","url_meta":{"origin":2308,"position":3},"title":"12m3 eto sterilizer is ready to send to our customer","author":"Bocon Technical Team","date":"2024-12-27","format":false,"excerpt":"12m3 eto sterilizer is ready to send to our customer","rel":"","context":"In &quot;Company News&quot;","block_context":{"text":"Company News","link":"https:\/\/zjbocon.com\/?cat=133125"},"img":{"alt_text":"","src":"https:\/\/i0.wp.com\/zjbocon.com\/wp-content\/uploads\/2025\/09\/eto-sterilizer-3.webp?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/zjbocon.com\/wp-content\/uploads\/2025\/09\/eto-sterilizer-3.webp?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/zjbocon.com\/wp-content\/uploads\/2025\/09\/eto-sterilizer-3.webp?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/zjbocon.com\/wp-content\/uploads\/2025\/09\/eto-sterilizer-3.webp?resize=700%2C400&ssl=1 2x, https:\/\/i0.wp.com\/zjbocon.com\/wp-content\/uploads\/2025\/09\/eto-sterilizer-3.webp?resize=1050%2C600&ssl=1 3x"},"classes":[]},{"id":2117,"url":"https:\/\/zjbocon.com\/?p=2117","url_meta":{"origin":2308,"position":4},"title":"Industry Eto Sterilizer Installation Verification","author":"Bocon Technical Team","date":"2024-11-06","format":false,"excerpt":"Industry Eto Sterilizer Installation Verification The installation of Industry Eto Sterilizer and all associated services should comply with the requirements of the construction and engineering drawings. It is recommended to verify the components of the Industry Eto Sterilizer to ensure the installation meets applicable standards and requirements. These equipment components\u2026","rel":"","context":"In &quot;ETO STERILIZER&quot;","block_context":{"text":"ETO STERILIZER","link":"https:\/\/zjbocon.com\/?cat=133124"},"img":{"alt_text":"","src":"https:\/\/i0.wp.com\/zjbocon.com\/wp-content\/uploads\/2024\/10\/sterilizer-station-design-2.webp?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/zjbocon.com\/wp-content\/uploads\/2024\/10\/sterilizer-station-design-2.webp?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/zjbocon.com\/wp-content\/uploads\/2024\/10\/sterilizer-station-design-2.webp?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/zjbocon.com\/wp-content\/uploads\/2024\/10\/sterilizer-station-design-2.webp?resize=700%2C400&ssl=1 2x"},"classes":[]},{"id":2554,"url":"https:\/\/zjbocon.com\/?p=2554","url_meta":{"origin":2308,"position":5},"title":"30 m\u00b3 eto gas sterilizer","author":"Bocon Technical Team","date":"2024-12-31","format":false,"excerpt":"The 30 m\u00b3 eto gas sterilizer consists of the sterilizer housing, auxiliary equipment (heating and thermal cycling device, vacuum extraction device, dosing and vaporization device, humidification device, sealing device, residual gas processing device), and monitoring and control device.","rel":"","context":"In &quot;Company News&quot;","block_context":{"text":"Company News","link":"https:\/\/zjbocon.com\/?cat=133125"},"img":{"alt_text":"","src":"https:\/\/i0.wp.com\/zjbocon.com\/wp-content\/uploads\/2025\/09\/ethylene-oxide-sterilization-57-scaled.webp?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/zjbocon.com\/wp-content\/uploads\/2025\/09\/ethylene-oxide-sterilization-57-scaled.webp?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/zjbocon.com\/wp-content\/uploads\/2025\/09\/ethylene-oxide-sterilization-57-scaled.webp?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/zjbocon.com\/wp-content\/uploads\/2025\/09\/ethylene-oxide-sterilization-57-scaled.webp?resize=700%2C400&ssl=1 2x, https:\/\/i0.wp.com\/zjbocon.com\/wp-content\/uploads\/2025\/09\/ethylene-oxide-sterilization-57-scaled.webp?resize=1050%2C600&ssl=1 3x, https:\/\/i0.wp.com\/zjbocon.com\/wp-content\/uploads\/2025\/09\/ethylene-oxide-sterilization-57-scaled.webp?resize=1400%2C800&ssl=1 4x"},"classes":[]}],"_links":{"self":[{"href":"https:\/\/zjbocon.com\/index.php?rest_route=\/wp\/v2\/posts\/2308","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/zjbocon.com\/index.php?rest_route=\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/zjbocon.com\/index.php?rest_route=\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/zjbocon.com\/index.php?rest_route=\/wp\/v2\/users\/234312599"}],"replies":[{"embeddable":true,"href":"https:\/\/zjbocon.com\/index.php?rest_route=%2Fwp%2Fv2%2Fcomments&post=2308"}],"version-history":[{"count":9,"href":"https:\/\/zjbocon.com\/index.php?rest_route=\/wp\/v2\/posts\/2308\/revisions"}],"predecessor-version":[{"id":8875,"href":"https:\/\/zjbocon.com\/index.php?rest_route=\/wp\/v2\/posts\/2308\/revisions\/8875"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/zjbocon.com\/index.php?rest_route=\/wp\/v2\/media\/8477"}],"wp:attachment":[{"href":"https:\/\/zjbocon.com\/index.php?rest_route=%2Fwp%2Fv2%2Fmedia&parent=2308"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/zjbocon.com\/index.php?rest_route=%2Fwp%2Fv2%2Fcategories&post=2308"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/zjbocon.com\/index.php?rest_route=%2Fwp%2Fv2%2Ftags&post=2308"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}