{"id":8843,"date":"2025-12-03T11:22:59","date_gmt":"2025-12-03T03:22:59","guid":{"rendered":"https:\/\/zjbocon.com\/?p=8843"},"modified":"2026-05-09T11:39:04","modified_gmt":"2026-05-09T03:39:04","slug":"eo-scrubber","status":"publish","type":"post","link":"https:\/\/zjbocon.com\/?p=8843","title":{"rendered":"Ethylene Oxide (EtO) Emissions Control: Technologies and Solutions"},"content":{"rendered":"\n<div class=\"wp-block-uagb-image uagb-block-847e6ceb wp-block-uagb-image--layout-default wp-block-uagb-image--effect-static wp-block-uagb-image--align-none\"><figure class=\"wp-block-uagb-image__figure\"><img loading=\"lazy\" decoding=\"async\" src=\"https:\/\/zjbocon.com\/wp-content\/uploads\/2025\/09\/eo-gas-scrubber-1024x1024.webp\" alt=\"\" class=\"uag-image-8100\" width=\"584\" height=\"584\" title=\"eo-gas-scrubber\" role=\"img\" \><\/figure><\/div>\n\n\n\n<p class=\"wp-block-paragraph\">효과적인 <strong>EtO 배출 제어<\/strong> 멸균, 화학물질 제조, 산업 운영 처리에 필수적입니다. <strong>산화에틸렌(EtO)<\/strong>. 최신 저감 기술은 시설이 규제 요구 사항을 충족하고 안전성을 향상하며 환경에 미치는 영향을 최소화하는 데 도움이 됩니다. 이 가이드는 기본 개요를 제공합니다. <strong>EtO 제어 기술<\/strong>, 습식 세정기, 열 산화기, 건식 베드 세정기, 촉매 산화기, 플레어, 버블링 세정기 및 통합 고려 사항을 포함합니다.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"h-5-1-eo-scrubber-packed-tower\"><strong>5.1 EO <a href=\"https:\/\/zjbocon.com\/product\/eo-scrubber\/\">가스 세정기<\/a> \/ Packed Tower<\/strong><\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Wet scrubbers, also known as packed towers, are effective devices for removing pollutants like EtO from industrial gas streams. These systems utilize a low-pH scrubbing liquid\u2014typically a water and acid mixture\u2014to absorb EtO. The acid catalyzes the conversion of EtO into Monoethylene Glycol (MEG).<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>작동 방식:<\/strong>&nbsp;오염된 가스는 탑 바닥으로 유입되어 충전재 층을 통해 위쪽으로 흐릅니다. 동시에 스프레이 노즐은 세정액을 패킹 위에 고르게 아래쪽으로 분배합니다. 이 디자인은 기액 접촉 표면적을 최대화하여 효율적인 흡수를 보장합니다. EtO 및 내산성 플라스틱 또는 금속으로 만들어진 포장재는 가스 흐름을 무작위화하고 표면 장력을 통해 액체 분산을 촉진합니다. 상단의 미스트 제거기는 깨끗한 공기가 빠져나가기 전에 동반된 모든 물방울을 포착합니다. 이제 액체 형태로 흡수된 EtO는 탑 바닥의 저장소에 수집되고 MEG로 완전히 전환되기 위해 저장 탱크로 펌핑됩니다.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>주요 설계 요소:<\/strong>&nbsp;타워 크기를 결정하는 주요 변수는 공기 흐름 속도입니다. 충전층은 완전한 EtO 흡수를 위해 충분한 체류 시간을 제공해야 합니다. 일관된 제어는 안정적인 액체 유속과 pH 수준을 유지하는 데 달려 있습니다.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>장점:<\/strong><\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>고온 및 고습도의 가스 흐름을 처리합니다.<\/li>\n\n\n\n<li>화재나 폭발 위험이 최소화됩니다.<\/li>\n\n\n\n<li>큰 공기량을 처리할 수 있습니다.<\/li>\n\n\n\n<li>달성할 수 있다 &gt;높은 유입 농도에 대한 파괴 효율은 99%입니다.<\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>단점:<\/strong><\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>산성 액체 및 이월로 인한 부식 가능성.<\/li>\n\n\n\n<li>추운 기후에서는 배관이 동결될 위험이 있습니다.<\/li>\n\n\n\n<li>수질이 좋지 않아 패킹과 액체가 오염될 가능성이 있습니다.<\/li>\n\n\n\n<li>높은 전력 소비.<\/li>\n\n\n\n<li>폐액 처리 및 지속적인 산 보충이 필요합니다.<\/li>\n\n\n\n<li>유지 관리에 필요한 안전 예방 조치.<\/li>\n<\/ul>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"h-5-2-thermal-oxidizers\"><strong>5.2 열산화제<\/strong><\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Thermal oxidizers destroy volatile organic compounds (VOCs), including EtO and other hazardous air pollutants (HAPs), through high-temperature combustion. Systems operate between 760\u00b0C (1,400\u00b0F) and 820\u00b0C (1,510\u00b0F), converting pollutants into carbon dioxide (CO?) and water vapor.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>작동 방식:<\/strong>&nbsp;안전을 위해 고농도 EtO 스트림은 먼저 물 균형 탱크 또는 화염 방지 장치를 통해 라우팅됩니다. 그런 다음 가스는 천연 가스 버너가 산화를 시작하는 연소실로 들어갑니다. EtO 자체가 열 방출에 기여합니다. 재생열산화기(RTO)에서 세라믹 열교환기는 배기가스에서 에너지를 포착하고 재사용하여 연료 효율성을 크게 향상시킵니다. EtO가 함유된 공기는 방출 전 완전한 산화를 보장하기 위해 설계된 체류 시간 동안 고온으로 유지됩니다.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>장점:<\/strong><\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>매우 높음(&gt;99%) 집중된 흐름에 대한 파괴 효율.<\/li>\n\n\n\n<li>상대적으로 작은 물리적 공간.<\/li>\n\n\n\n<li>에너지 회수 가능성(특히 RTO에서)<\/li>\n\n\n\n<li>간단한 운영 메커니즘.<\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>단점:<\/strong><\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>공기 흐름이 매우 높고 농도가 낮은 흐름에는 적합하지 않습니다.<\/li>\n\n\n\n<li>연료 가스 소비량이 높습니다(재생용이 아닌 경우).<\/li>\n\n\n\n<li>폭발 위험과 관련된 잠재적인 안전 문제.<\/li>\n\n\n\n<li>연소 부산물로 질소산화물(NOx)이 생성될 수 있습니다.<\/li>\n<\/ul>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"h-5-3-dry-bed-scrubber\"><strong>5.3 건식 베드 스크러버<\/strong><\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">건식 베드 스크러버는 화학적으로 함침된 폴리머 비드(반응 매체)로 채워진 용기를 사용하여 화학 흡착 및 화학 반응을 통해 EtO를 영구적으로 제거하여 무해한 폴리머로 변환합니다.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>작동 방식:<\/strong>&nbsp;오염된 공기는 EtO 분자가 비드 표면에 부착되어 반응하는 고정된 매체층을 통과합니다. 시스템은 특정 공기 흐름 속도에서 반응에 적절한 체류 시간을 제공하도록 크기가 조정되었습니다. 침대 배출구의 지지 스크린은 미디어의 이월을 방지합니다. 이러한 시스템은 매우 효과적이며 다음과 같은 목표를 달성합니다. &gt;~5ppmv 이상의 유입 농도에 대해 99% 파괴 효율.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>장점:<\/strong><\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>모듈형 설계로 쉽게 확장할 수 있습니다.<\/li>\n\n\n\n<li>낮은 운영 복잡성; 팬만 필요합니다.<\/li>\n\n\n\n<li>일부 시스템에 비해 자본 및 운영 비용이 낮습니다.<\/li>\n\n\n\n<li>영구적인 EtO 전환; 유해하지 않은 폐기물을 생성합니다.<\/li>\n\n\n\n<li>안전한 작동 및 유지 관리.<\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>단점:<\/strong><\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>습도가 높거나 온도가 높은 하천은 처리할 수 없습니다.<\/li>\n\n\n\n<li>미디어는 용량이 한정되어 있어 정기적인 교체가 필요합니다.<\/li>\n\n\n\n<li>농도에 적합하지 않음 &gt;발열 반응 위험으로 인해 5,000ppmv.<\/li>\n<\/ul>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"h-5-4-thermal-flare\"><strong>5.4 열 플레어<\/strong><\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">플레어는 정유소, 화학 공장 및 유사한 시설에서 공정 통풍구, 안전 밸브 방출 또는 폐쇄형 통풍 시스템의 결합 폐기물 흐름에서 EtO를 안전하게 파괴하는 데 사용됩니다.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>작동 방식:<\/strong>&nbsp;연료 가스에 의해 유지되는 파일럿 화염이 항상 유지됩니다. EtO 스트림(종종 기화되고 희석됨)이 이 연소 구역으로 도입됩니다. 시스템은 연소율을 지속적으로 모니터링하고 조정하여 최소 순 발열량을 유지하여 안정적인 연소를 보장합니다. &gt;파괴효율 99%. EtO가 CO로 분해되나요? 그리고 물. 플레어는 수직 또는 수평이 될 수 있으며 일부 모델에는 폐열 회수 시스템이 통합되어 있습니다.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>장점:<\/strong><\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>매우 가변적이거나 간헐적이거나 복잡한 혼합 스트림을 처리할 수 있습니다.<\/li>\n\n\n\n<li>고에너지, 고VOC 공정에 효과적입니다.<\/li>\n\n\n\n<li>열 회수 가능성.<\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>단점:<\/strong><\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Very high fuel\/utility usage.<\/li>\n\n\n\n<li>눈에 보이는 불꽃은 빛공해나 대중의 우려를 유발할 수 있습니다.<\/li>\n\n\n\n<li>복잡한 유지 관리 및 통합.<\/li>\n\n\n\n<li>역화 위험이 있어 화염 방지 장치, 퍼지 시스템, 속도 모니터링과 같은 보호 장치가 필요합니다.<\/li>\n<\/ul>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"h-5-5-bubbling-scrubbers\"><strong>5.5 버블링 스크러버<\/strong><\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Bubbling scrubbers, or bubble tank scrubbers, use a low-pH acid\/water solution to chemically convert EtO to MEG through a direct bubbling contact method.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>작동 방식:<\/strong>&nbsp;저유량 EtO 가스는 일련의 반응 탱크(종종 2단계)의 바닥으로 펌핑됩니다. 천공형 디퓨저는 액체를 통해 상승하는 미세한 기포를 생성하여 반응이 일어나기 위한 체류 시간을 제공합니다. 원심 송풍기는 부압을 유지하여 가스를 스테이지를 통해 밀어냅니다. MEG가 생산됨에 따라 주요 모니터링 매개변수인 액체 레벨과 비중이 상승합니다. 중화 및 폐기를 위해 MEG 용액을 이송하여 탱크를 주기적으로 재생합니다.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>장점:<\/strong><\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>본질적으로 안전한 액체 기반 시스템.<\/li>\n\n\n\n<li>고농도, 저유량 흐름을 위한 높은(99-99.9%) 효율성.<\/li>\n\n\n\n<li>고장이 거의 없는 심플한 디자인.<\/li>\n\n\n\n<li>매개변수가 안정적일 때 일관된 제어.<\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>단점:<\/strong><\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>공기 흐름이 높은 용도에는 적합하지 않습니다.<\/li>\n\n\n\n<li>산과 염기의 취급과 관련됩니다.<\/li>\n\n\n\n<li>산 및 폐기물 MEG 용액 관리에 대한 지속적인 비용.<\/li>\n\n\n\n<li><strong>메모:<\/strong>&nbsp;EtO가 함유된 물을 처리하지 않고 저장만 하는 패시브 밸런싱 탱크(피크 면도기)와는 다릅니다.<\/li>\n<\/ul>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"h-5-6-catalytic-oxidizer\"><strong>5.6 촉매 산화제<\/strong><\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">촉매산화제는 귀금속이나 금속산화물 촉매를 사용해 열산화제보다 훨씬 낮은 온도에서 산화를 촉진해 EtO 같은 VOC를 제어한다.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>작동 방식:<\/strong>&nbsp;The process gas is heated to a catalyst activation temperature (typically 150\u00b0C to 400\u00b0C \/ 300\u00b0F to 750\u00b0F) before passing over the catalyst bed. In the presence of excess oxygen, the catalyst promotes the complete oxidation of EtO to CO? and water vapor. Heat exchangers can be added for energy recovery. This technology is ideal for low-concentration EtO streams.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>장점:<\/strong><\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>낮은 작동 온도는 연료 소비 감소와 에너지 효율성 향상을 의미합니다.<\/li>\n\n\n\n<li>열적 NOx 및 CO의 형성을 최소화합니다.<\/li>\n\n\n\n<li>99-99.9% 파괴 효율을 달성할 수 있습니다.<\/li>\n\n\n\n<li>더욱 친환경적인 운영.<\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>단점:<\/strong><\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>촉매는 황, 규소, 인 또는 중금속으로 인한 중독에 민감합니다.<\/li>\n\n\n\n<li>일반적으로 열산화기보다 설치 면적이 더 큽니다.<\/li>\n\n\n\n<li>높은 자본 비용과 주기적인 촉매 교체 비용.<\/li>\n<\/ul>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"h-if-you-want-to-know-more\">더 알고 싶다면<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">핸드폰:<a href=\"https:\/\/wa.me\/8619975258603\">+8619975258603<\/a><\/p>\n\n\n\n<p class=\"wp-block-paragraph\">이메일:<a href=\"mailto:hayley@hzbocon.com\">hayley@hzbocon.com<\/a><\/p>\n\n\n\n<p class=\"wp-block-paragraph\">현지 사이트: 중국 절강성 항저우시 샤사구 차이통 중신 1202호<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">웹사이트:<a href=\"https:\/\/www.hzbocon.com\/\">hzbocon.com<\/a><\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><\/p>\n","protected":false},"excerpt":{"rendered":"<p>효과적인 EtO 배출 제어는 산화에틸렌(EtO)을 취급하는 멸균, 화학물질 제조 및 산업 운영에 필수적입니다. 최신 저감 기술은 시설이 규제 요구 사항을 충족하고 안전성을 향상하며 환경에 미치는 영향을 최소화하는 데 도움이 됩니다. 이 가이드는 습식 스크러버, 열 산화기, 건식 베드 스크러버, 촉매 산화기, 플레어, 버블링 스크러버 및 통합 고려 사항을 포함한 기본 EtO 제어 기술에 대한 최적화되고 SEO가 가능한 개요를 제공합니다.<\/p>\n","protected":false},"author":234312599,"featured_media":8182,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_uag_custom_page_level_css":"","site-sidebar-layout":"default","site-content-layout":"","ast-site-content-layout":"default","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","ast-disable-related-posts":"","theme-transparent-header-meta":"","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"default","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"_jetpack_newsletter_access":"","_jetpack_dont_email_post_to_subs":false,"_jetpack_newsletter_tier_id":0,"_jetpack_memberships_contains_paywalled_content":false,"_jetpack_feature_clip_id":0,"_jetpack_memberships_contains_paid_content":false,"footnotes":"","jetpack_publicize_message":"","jetpack_publicize_feature_enabled":true,"jetpack_social_post_already_shared":false,"jetpack_social_options":{"image_generator_settings":{"template":"highway","default_image_id":0,"font":"","enabled":false},"version":2},"jetpack_post_was_ever_published":false},"categories":[133125,133124],"tags":[],"class_list":["post-8843","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-company-news","category-eto-sterilizer"],"yoast_head":"<!-- This site is optimized with the Yoast SEO Premium plugin v27.2 (Yoast SEO v28.0) - https:\/\/yoast.com\/product\/yoast-seo-premium-wordpress\/ -->\n<title>EtO(에틸렌산화물) 배출 제어: 기술 및 솔루션 - ETO STERILIZER<\/title>\n<meta name=\"description\" content=\"Effective EtO emissions control is essential for sterilization, chemical manufacturing, and industrial operations handling ethylene oxide (EtO). Modern abatement technologies help facilities meet regulatory requirements, improve safety, minimize environmental impact. This guide provides an optimized, SEO-ready overview of primary technologies, including wet scrubbers, thermal oxidizers, dry bed catalytic flares, bubbling integration considerations.\" \>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \>\n<link rel=\"canonical\" href=\"https:\/\/zjbocon.com\/?p=8843\" \>\n<meta property=\"og:locale\" content=\"ko_KR\" \>\n<meta property=\"og:type\" content=\"article\" \>\n<meta property=\"og:title\" content=\"Ethylene Oxide (EtO) Emissions Control: Technologies and Solutions\" \>\n<meta property=\"og:description\" content=\"Effective EtO emissions control is essential for sterilization, chemical manufacturing, and industrial operations handling ethylene oxide (EtO). Modern abatement technologies help facilities meet regulatory requirements, improve safety, minimize environmental impact. This guide provides an optimized, SEO-ready overview of primary technologies, including wet scrubbers, thermal oxidizers, dry bed catalytic flares, bubbling integration considerations.\" \>\n<meta property=\"og:url\" content=\"https:\/\/zjbocon.com\/?p=8843\" \>\n<meta property=\"og:site_name\" content=\"ETO STERILIZER\" \>\n<meta property=\"article:publisher\" content=\"https:\/\/www.facebook.com\/profile.php?id=100088482339878\" \>\n<meta property=\"article:author\" content=\"https:\/\/www.facebook.com\/profile.php?id=100088482339878\" \>\n<meta property=\"article:published_time\" content=\"2025-12-03T03:22:59+00:00\" \>\n<meta property=\"article:modified_time\" content=\"2026-05-09T03:39:04+00:00\" \>\n<meta property=\"og:image\" content=\"https:\/\/zjbocon.com\/wp-content\/uploads\/2025\/09\/eo-gas-scrubber-1.webp\" \>\n\t<meta property=\"og:image:width\" content=\"1080\" \>\n\t<meta property=\"og:image:height\" content=\"1080\" \>\n\t<meta property=\"og:image:type\" content=\"image\/webp\" \>\n<meta name=\"author\" content=\"Bocon Technical Team\" \>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \>\n<meta name=\"twitter:creator\" content=\"@BoconAnd\" \>\n<meta name=\"twitter:site\" content=\"@BoconAnd\" \>\n<meta name=\"twitter:label1\" content=\"Written by\" \>\n\t<meta name=\"twitter:data1\" content=\"Bocon Technical Team\" \>\n\t<meta name=\"twitter:label2\" content=\"Est. reading time\" \>\n\t<meta name=\"twitter:data2\" content=\"6 minutes\" \>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\\\/\\\/zjbocon.com\\\/?p=8843#article\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/zjbocon.com\\\/?p=8843\"},\"author\":{\"name\":\"Bocon Technical Team\",\"@id\":\"https:\\\/\\\/zjbocon.com\\\/#\\\/schema\\\/person\\\/f12be028b8ae9843a4396dcc8012b425\"},\"headline\":\"Ethylene Oxide (EtO) Emissions Control: Technologies and Solutions\",\"datePublished\":\"2025-12-03T03:22:59+00:00\",\"dateModified\":\"2026-05-09T03:39:04+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/zjbocon.com\\\/?p=8843\"},\"wordCount\":1145,\"commentCount\":0,\"publisher\":{\"@id\":\"https:\\\/\\\/zjbocon.com\\\/#organization\"},\"image\":{\"@id\":\"https:\\\/\\\/zjbocon.com\\\/?p=8843#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/zjbocon.com\\\/wp-content\\\/uploads\\\/2025\\\/09\\\/eo-gas-scrubber-1.webp\",\"articleSection\":[\"Company News\",\"ETO STERILIZER\"],\"inLanguage\":\"ko-KR\",\"potentialAction\":[{\"@type\":\"CommentAction\",\"name\":\"Comment\",\"target\":[\"https:\\\/\\\/zjbocon.com\\\/?p=8843#respond\"]}]},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/zjbocon.com\\\/?p=8843\",\"url\":\"https:\\\/\\\/zjbocon.com\\\/?p=8843\",\"name\":\"Ethylene Oxide (EtO) Emissions Control: Technologies and Solutions - ETO STERILIZER\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/zjbocon.com\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/zjbocon.com\\\/?p=8843#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/zjbocon.com\\\/?p=8843#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/zjbocon.com\\\/wp-content\\\/uploads\\\/2025\\\/09\\\/eo-gas-scrubber-1.webp\",\"datePublished\":\"2025-12-03T03:22:59+00:00\",\"dateModified\":\"2026-05-09T03:39:04+00:00\",\"description\":\"Effective EtO emissions control is essential for sterilization, chemical manufacturing, and industrial operations handling ethylene oxide (EtO). Modern abatement technologies help facilities meet regulatory requirements, improve safety, and minimize environmental impact. This guide provides an optimized, SEO-ready overview of primary EtO control technologies, including wet scrubbers, thermal oxidizers, dry bed scrubbers, catalytic oxidizers, flares, bubbling scrubbers, and integration considerations.\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/zjbocon.com\\\/?p=8843#breadcrumb\"},\"inLanguage\":\"ko-KR\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/zjbocon.com\\\/?p=8843\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"ko-KR\",\"@id\":\"https:\\\/\\\/zjbocon.com\\\/?p=8843#primaryimage\",\"url\":\"https:\\\/\\\/zjbocon.com\\\/wp-content\\\/uploads\\\/2025\\\/09\\\/eo-gas-scrubber-1.webp\",\"contentUrl\":\"https:\\\/\\\/zjbocon.com\\\/wp-content\\\/uploads\\\/2025\\\/09\\\/eo-gas-scrubber-1.webp\",\"width\":1080,\"height\":1080},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/zjbocon.com\\\/?p=8843#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/zjbocon.com\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Ethylene Oxide (EtO) Emissions Control: Technologies and Solutions\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/zjbocon.com\\\/#website\",\"url\":\"https:\\\/\\\/zjbocon.com\\\/\",\"name\":\"ETO STERILIZER\",\"description\":\"One-stop Solution Supplier of Ethylene Oxide Sterilization\",\"publisher\":{\"@id\":\"https:\\\/\\\/zjbocon.com\\\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/zjbocon.com\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"ko-KR\"},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/zjbocon.com\\\/#organization\",\"name\":\"ETO STERILIZER\",\"url\":\"https:\\\/\\\/zjbocon.com\\\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"ko-KR\",\"@id\":\"https:\\\/\\\/zjbocon.com\\\/#\\\/schema\\\/logo\\\/image\\\/\",\"url\":\"https:\\\/\\\/zjbocon.com\\\/wp-content\\\/uploads\\\/2024\\\/10\\\/logo-1.webp\",\"contentUrl\":\"https:\\\/\\\/zjbocon.com\\\/wp-content\\\/uploads\\\/2024\\\/10\\\/logo-1.webp\",\"width\":180,\"height\":60,\"caption\":\"ETO STERILIZER\"},\"image\":{\"@id\":\"https:\\\/\\\/zjbocon.com\\\/#\\\/schema\\\/logo\\\/image\\\/\"},\"sameAs\":[\"https:\\\/\\\/www.facebook.com\\\/profile.php?id=100088482339878\",\"https:\\\/\\\/x.com\\\/BoconAnd\",\"https:\\\/\\\/www.linkedin.com\\\/in\\\/--06a221139\\\/\"]},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/zjbocon.com\\\/#\\\/schema\\\/person\\\/f12be028b8ae9843a4396dcc8012b425\",\"name\":\"Bocon Technical Team\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"ko-KR\",\"@id\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/d7a825658be227f26b237e519f8541e05aabc9ff27b8eec4544a233a48c53be0?s=96&d=identicon&r=g\",\"url\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/d7a825658be227f26b237e519f8541e05aabc9ff27b8eec4544a233a48c53be0?s=96&d=identicon&r=g\",\"contentUrl\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/d7a825658be227f26b237e519f8541e05aabc9ff27b8eec4544a233a48c53be0?s=96&d=identicon&r=g\",\"caption\":\"Bocon Technical Team\"},\"sameAs\":[\"https:\\\/\\\/zjbocon.com\\\/\",\"https:\\\/\\\/www.facebook.com\\\/profile.php?id=100088482339878\",\"https:\\\/\\\/www.linkedin.com\\\/in\\\/\\\/hayley--968190269\\\/\"],\"url\":\"https:\\\/\\\/zjbocon.com\\\/?author=234312599\"}]}<\/script>\n<!-- \/ Yoast SEO Premium plugin. -->","yoast_head_json":{"title":"Ethylene Oxide (EtO) Emissions Control: Technologies and Solutions - ETO STERILIZER","description":"Effective EtO emissions control is essential for sterilization, chemical manufacturing, and industrial operations handling ethylene oxide (EtO). Modern abatement technologies help facilities meet regulatory requirements, improve safety, and minimize environmental impact. This guide provides an optimized, SEO-ready overview of primary EtO control technologies, including wet scrubbers, thermal oxidizers, dry bed scrubbers, catalytic oxidizers, flares, bubbling scrubbers, and integration considerations.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/zjbocon.com\/?p=8843","og_locale":"ko_KR","og_type":"article","og_title":"Ethylene Oxide (EtO) Emissions Control: Technologies and Solutions","og_description":"Effective EtO emissions control is essential for sterilization, chemical manufacturing, and industrial operations handling ethylene oxide (EtO). Modern abatement technologies help facilities meet regulatory requirements, improve safety, and minimize environmental impact. This guide provides an optimized, SEO-ready overview of primary EtO control technologies, including wet scrubbers, thermal oxidizers, dry bed scrubbers, catalytic oxidizers, flares, bubbling scrubbers, and integration considerations.","og_url":"https:\/\/zjbocon.com\/?p=8843","og_site_name":"ETO STERILIZER","article_publisher":"https:\/\/www.facebook.com\/profile.php?id=100088482339878","article_author":"https:\/\/www.facebook.com\/profile.php?id=100088482339878","article_published_time":"2025-12-03T03:22:59+00:00","article_modified_time":"2026-05-09T03:39:04+00:00","og_image":[{"width":1080,"height":1080,"url":"https:\/\/zjbocon.com\/wp-content\/uploads\/2025\/09\/eo-gas-scrubber-1.webp","type":"image\/webp"}],"author":"Bocon Technical Team","twitter_card":"summary_large_image","twitter_creator":"@BoconAnd","twitter_site":"@BoconAnd","twitter_misc":{"Written by":"Bocon Technical Team","Est. reading time":"6 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/zjbocon.com\/?p=8843#article","isPartOf":{"@id":"https:\/\/zjbocon.com\/?p=8843"},"author":{"name":"Bocon Technical Team","@id":"https:\/\/zjbocon.com\/#\/schema\/person\/f12be028b8ae9843a4396dcc8012b425"},"headline":"Ethylene Oxide (EtO) Emissions Control: Technologies and Solutions","datePublished":"2025-12-03T03:22:59+00:00","dateModified":"2026-05-09T03:39:04+00:00","mainEntityOfPage":{"@id":"https:\/\/zjbocon.com\/?p=8843"},"wordCount":1145,"commentCount":0,"publisher":{"@id":"https:\/\/zjbocon.com\/#organization"},"image":{"@id":"https:\/\/zjbocon.com\/?p=8843#primaryimage"},"thumbnailUrl":"https:\/\/zjbocon.com\/wp-content\/uploads\/2025\/09\/eo-gas-scrubber-1.webp","articleSection":["Company News","ETO STERILIZER"],"inLanguage":"ko-KR","potentialAction":[{"@type":"CommentAction","name":"Comment","target":["https:\/\/zjbocon.com\/?p=8843#respond"]}]},{"@type":"WebPage","@id":"https:\/\/zjbocon.com\/?p=8843","url":"https:\/\/zjbocon.com\/?p=8843","name":"Ethylene Oxide (EtO) Emissions Control: Technologies and Solutions - ETO STERILIZER","isPartOf":{"@id":"https:\/\/zjbocon.com\/#website"},"primaryImageOfPage":{"@id":"https:\/\/zjbocon.com\/?p=8843#primaryimage"},"image":{"@id":"https:\/\/zjbocon.com\/?p=8843#primaryimage"},"thumbnailUrl":"https:\/\/zjbocon.com\/wp-content\/uploads\/2025\/09\/eo-gas-scrubber-1.webp","datePublished":"2025-12-03T03:22:59+00:00","dateModified":"2026-05-09T03:39:04+00:00","description":"Effective EtO emissions control is essential for sterilization, chemical manufacturing, and industrial operations handling ethylene oxide (EtO). Modern abatement technologies help facilities meet regulatory requirements, improve safety, and minimize environmental impact. This guide provides an optimized, SEO-ready overview of primary EtO control technologies, including wet scrubbers, thermal oxidizers, dry bed scrubbers, catalytic oxidizers, flares, bubbling scrubbers, and integration considerations.","breadcrumb":{"@id":"https:\/\/zjbocon.com\/?p=8843#breadcrumb"},"inLanguage":"ko-KR","potentialAction":[{"@type":"ReadAction","target":["https:\/\/zjbocon.com\/?p=8843"]}]},{"@type":"ImageObject","inLanguage":"ko-KR","@id":"https:\/\/zjbocon.com\/?p=8843#primaryimage","url":"https:\/\/zjbocon.com\/wp-content\/uploads\/2025\/09\/eo-gas-scrubber-1.webp","contentUrl":"https:\/\/zjbocon.com\/wp-content\/uploads\/2025\/09\/eo-gas-scrubber-1.webp","width":1080,"height":1080},{"@type":"BreadcrumbList","@id":"https:\/\/zjbocon.com\/?p=8843#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/zjbocon.com\/"},{"@type":"ListItem","position":2,"name":"Ethylene Oxide (EtO) Emissions Control: Technologies and Solutions"}]},{"@type":"WebSite","@id":"https:\/\/zjbocon.com\/#website","url":"https:\/\/zjbocon.com\/","name":"ETO STERILIZER","description":"One-stop Solution Supplier of Ethylene Oxide Sterilization","publisher":{"@id":"https:\/\/zjbocon.com\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/zjbocon.com\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"ko-KR"},{"@type":"Organization","@id":"https:\/\/zjbocon.com\/#organization","name":"ETO STERILIZER","url":"https:\/\/zjbocon.com\/","logo":{"@type":"ImageObject","inLanguage":"ko-KR","@id":"https:\/\/zjbocon.com\/#\/schema\/logo\/image\/","url":"https:\/\/zjbocon.com\/wp-content\/uploads\/2024\/10\/logo-1.webp","contentUrl":"https:\/\/zjbocon.com\/wp-content\/uploads\/2024\/10\/logo-1.webp","width":180,"height":60,"caption":"ETO STERILIZER"},"image":{"@id":"https:\/\/zjbocon.com\/#\/schema\/logo\/image\/"},"sameAs":["https:\/\/www.facebook.com\/profile.php?id=100088482339878","https:\/\/x.com\/BoconAnd","https:\/\/www.linkedin.com\/in\/--06a221139\/"]},{"@type":"Person","@id":"https:\/\/zjbocon.com\/#\/schema\/person\/f12be028b8ae9843a4396dcc8012b425","name":"Bocon Technical Team","image":{"@type":"ImageObject","inLanguage":"ko-KR","@id":"https:\/\/secure.gravatar.com\/avatar\/d7a825658be227f26b237e519f8541e05aabc9ff27b8eec4544a233a48c53be0?s=96&d=identicon&r=g","url":"https:\/\/secure.gravatar.com\/avatar\/d7a825658be227f26b237e519f8541e05aabc9ff27b8eec4544a233a48c53be0?s=96&d=identicon&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/d7a825658be227f26b237e519f8541e05aabc9ff27b8eec4544a233a48c53be0?s=96&d=identicon&r=g","caption":"Bocon Technical Team"},"sameAs":["https:\/\/zjbocon.com\/","https:\/\/www.facebook.com\/profile.php?id=100088482339878","https:\/\/www.linkedin.com\/in\/\/hayley--968190269\/"],"url":"https:\/\/zjbocon.com\/?author=234312599"}]}},"jetpack_publicize_connections":[],"jetpack_featured_media_url":"https:\/\/zjbocon.com\/wp-content\/uploads\/2025\/09\/eo-gas-scrubber-1.webp","uagb_featured_image_src":{"full":["https:\/\/zjbocon.com\/wp-content\/uploads\/2025\/09\/eo-gas-scrubber-1.webp",1080,1080,false],"thumbnail":["https:\/\/zjbocon.com\/wp-content\/uploads\/2025\/09\/eo-gas-scrubber-1-150x150.webp",150,150,true],"medium":["https:\/\/zjbocon.com\/wp-content\/uploads\/2025\/09\/eo-gas-scrubber-1-300x300.webp",300,300,true],"medium_large":["https:\/\/zjbocon.com\/wp-content\/uploads\/2025\/09\/eo-gas-scrubber-1-768x768.webp",768,768,true],"large":["https:\/\/zjbocon.com\/wp-content\/uploads\/2025\/09\/eo-gas-scrubber-1-1024x1024.webp",1024,1024,true],"1536x1536":["https:\/\/zjbocon.com\/wp-content\/uploads\/2025\/09\/eo-gas-scrubber-1.webp",1080,1080,false],"2048x2048":["https:\/\/zjbocon.com\/wp-content\/uploads\/2025\/09\/eo-gas-scrubber-1.webp",1080,1080,false],"woocommerce_thumbnail":["https:\/\/zjbocon.com\/wp-content\/uploads\/2025\/09\/eo-gas-scrubber-1-600x600.webp",600,600,true],"woocommerce_single":["https:\/\/zjbocon.com\/wp-content\/uploads\/2025\/09\/eo-gas-scrubber-1-600x600.webp",600,600,true],"woocommerce_gallery_thumbnail":["https:\/\/zjbocon.com\/wp-content\/uploads\/2025\/09\/eo-gas-scrubber-1-100x100.webp",100,100,true]},"uagb_author_info":{"display_name":"Bocon Technical Team","author_link":"https:\/\/zjbocon.com\/?author=234312599"},"uagb_comment_info":0,"uagb_excerpt":"Effective EtO emissions control is essential for sterilization, chemical manufacturing, and industrial operations handling ethylene oxide (EtO). Modern abatement technologies help facilities meet regulatory requirements, improve safety, and minimize environmental impact. This guide provides an optimized, SEO-ready overview of primary EtO control technologies, including wet scrubbers, thermal oxidizers, dry bed scrubbers, catalytic oxidizers, flares, bubbling&hellip;","jetpack_likes_enabled":true,"jetpack_sharing_enabled":true,"jetpack_shortlink":"https:\/\/wp.me\/pgZDV6-2iD","jetpack-related-posts":[{"id":8772,"url":"https:\/\/zjbocon.com\/?p=8772","url_meta":{"origin":8843,"position":0},"title":"ETO STERILIZATION Safety Guidelines: Best Practices for Using Ethylene Oxide as a Sterilant","author":"Bocon Technical Team","date":"2025-11-25","format":false,"excerpt":"Ethylene oxide (ETO STERILIZATION) is widely used as a low-temperature sterilant in industries like healthcare, pharmaceuticals, and biotechnology. However, due to its toxic, flammable, and potentially carcinogenic properties, it's critical to follow strict safety protocols. This article outlines the essential safety guidelines for safely operating ETO STERILIZATION systems. 1. Regulatory\u2026","rel":"","context":"In &quot;Company News&quot;","block_context":{"text":"Company News","link":"https:\/\/zjbocon.com\/?cat=133125"},"img":{"alt_text":"","src":"https:\/\/i0.wp.com\/zjbocon.com\/wp-content\/uploads\/2025\/11\/eto-sterilzer-scaled.webp?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/zjbocon.com\/wp-content\/uploads\/2025\/11\/eto-sterilzer-scaled.webp?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/zjbocon.com\/wp-content\/uploads\/2025\/11\/eto-sterilzer-scaled.webp?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/zjbocon.com\/wp-content\/uploads\/2025\/11\/eto-sterilzer-scaled.webp?resize=700%2C400&ssl=1 2x, https:\/\/i0.wp.com\/zjbocon.com\/wp-content\/uploads\/2025\/11\/eto-sterilzer-scaled.webp?resize=1050%2C600&ssl=1 3x, https:\/\/i0.wp.com\/zjbocon.com\/wp-content\/uploads\/2025\/11\/eto-sterilzer-scaled.webp?resize=1400%2C800&ssl=1 4x"},"classes":[]},{"id":9304,"url":"https:\/\/zjbocon.com\/?p=9304","url_meta":{"origin":8843,"position":1},"title":"Code Compliance: Ethylene Oxide (ETO)","author":"Bocon Technical Team","date":"2026-02-09","format":false,"excerpt":"Expert guide to California ETO safety codes. Explore ASME-standard sterilization and BOCON's EO Scrubber systems to ensure 100% compliance for your facility.","rel":"","context":"In &quot;ETO STERILIZER&quot;","block_context":{"text":"ETO STERILIZER","link":"https:\/\/zjbocon.com\/?cat=133124"},"img":{"alt_text":"Turnkey-EO-Sterilisation-Project","src":"https:\/\/i0.wp.com\/zjbocon.com\/wp-content\/uploads\/2025\/09\/Turnkey-EO-Sterilisation-Project-1-scaled.webp?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/zjbocon.com\/wp-content\/uploads\/2025\/09\/Turnkey-EO-Sterilisation-Project-1-scaled.webp?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/zjbocon.com\/wp-content\/uploads\/2025\/09\/Turnkey-EO-Sterilisation-Project-1-scaled.webp?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/zjbocon.com\/wp-content\/uploads\/2025\/09\/Turnkey-EO-Sterilisation-Project-1-scaled.webp?resize=700%2C400&ssl=1 2x, https:\/\/i0.wp.com\/zjbocon.com\/wp-content\/uploads\/2025\/09\/Turnkey-EO-Sterilisation-Project-1-scaled.webp?resize=1050%2C600&ssl=1 3x, https:\/\/i0.wp.com\/zjbocon.com\/wp-content\/uploads\/2025\/09\/Turnkey-EO-Sterilisation-Project-1-scaled.webp?resize=1400%2C800&ssl=1 4x"},"classes":[]},{"id":8958,"url":"https:\/\/zjbocon.com\/?p=8958","url_meta":{"origin":8843,"position":2},"title":"Understanding What is ETO Sterilizers: A Comprehensive Guide","author":"Bocon Technical Team","date":"2025-12-16","format":false,"excerpt":"Discover the essentials of ETO sterilizers and ethylene oxide sterilization, ensuring the highest hygiene standards in healthcare and beyond.","rel":"","context":"In &quot;Company News&quot;","block_context":{"text":"Company News","link":"https:\/\/zjbocon.com\/?cat=133125"},"img":{"alt_text":"","src":"https:\/\/i0.wp.com\/zjbocon.com\/wp-content\/uploads\/2024\/11\/eto-sterilizer-hzbocon-3.png?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/zjbocon.com\/wp-content\/uploads\/2024\/11\/eto-sterilizer-hzbocon-3.png?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/zjbocon.com\/wp-content\/uploads\/2024\/11\/eto-sterilizer-hzbocon-3.png?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/zjbocon.com\/wp-content\/uploads\/2024\/11\/eto-sterilizer-hzbocon-3.png?resize=700%2C400&ssl=1 2x, https:\/\/i0.wp.com\/zjbocon.com\/wp-content\/uploads\/2024\/11\/eto-sterilizer-hzbocon-3.png?resize=1050%2C600&ssl=1 3x"},"classes":[]},{"id":9276,"url":"https:\/\/zjbocon.com\/?p=9276","url_meta":{"origin":8843,"position":3},"title":"Sterilization Compatibility of Sterile Barrier Systems","author":"Bocon Technical Team","date":"2026-02-06","format":false,"excerpt":"Sterilization Compatibility of Sterile Barrier Systems Technical White Paper 1. Introduction The compatibility between sterile barrier systems (SBS) and sterilization processes is a critical engineering consideration in medical device packaging design. Inappropriate material-process combinations may lead to insufficient sterilant penetration, material degradation, or loss of microbial barrier integrity. This technical\u2026","rel":"","context":"In &quot;ETO STERILIZER&quot;","block_context":{"text":"ETO STERILIZER","link":"https:\/\/zjbocon.com\/?cat=133124"},"img":{"alt_text":"","src":"https:\/\/i0.wp.com\/zjbocon.com\/wp-content\/uploads\/2024\/11\/eto-sterilizer-hzbocon-5.png?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/zjbocon.com\/wp-content\/uploads\/2024\/11\/eto-sterilizer-hzbocon-5.png?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/zjbocon.com\/wp-content\/uploads\/2024\/11\/eto-sterilizer-hzbocon-5.png?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/zjbocon.com\/wp-content\/uploads\/2024\/11\/eto-sterilizer-hzbocon-5.png?resize=700%2C400&ssl=1 2x, https:\/\/i0.wp.com\/zjbocon.com\/wp-content\/uploads\/2024\/11\/eto-sterilizer-hzbocon-5.png?resize=1050%2C600&ssl=1 3x"},"classes":[]},{"id":2004,"url":"https:\/\/zjbocon.com\/?p=2004","url_meta":{"origin":8843,"position":4},"title":"The Guide to ethylene oxide in sterilization","author":"Bocon Technical Team","date":"2024-10-28","format":false,"excerpt":"ethylene oxide in sterilization Introduction ETO is a colorless gas that is flammable and explosive. The four essential parameters (operational ranges) of ethylene oxide in sterilization are: gas concentration (450 to 1200 mg\/l); temperature (37 to 63\u00b0C); relative humidity (40 to 80%)(water molecules carry ETO to reactive sites); and exposure\u2026","rel":"","context":"In &quot;ETO STERILIZER&quot;","block_context":{"text":"ETO STERILIZER","link":"https:\/\/zjbocon.com\/?cat=133124"},"img":{"alt_text":"Industry_ETO_Sterilizer","src":"https:\/\/i0.wp.com\/zjbocon.com\/wp-content\/uploads\/2024\/10\/Industry_ETO_Sterilizer.webp?resize=350%2C200","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/zjbocon.com\/wp-content\/uploads\/2024\/10\/Industry_ETO_Sterilizer.webp?resize=350%2C200 1x, https:\/\/i0.wp.com\/zjbocon.com\/wp-content\/uploads\/2024\/10\/Industry_ETO_Sterilizer.webp?resize=525%2C300 1.5x, https:\/\/i0.wp.com\/zjbocon.com\/wp-content\/uploads\/2024\/10\/Industry_ETO_Sterilizer.webp?resize=700%2C400 2x"},"classes":[]},{"id":2439,"url":"https:\/\/zjbocon.com\/?p=2439","url_meta":{"origin":8843,"position":5},"title":"Preparatory Work Before eto Sterilization","author":"Bocon Technical Team","date":"2024-12-17","format":false,"excerpt":"Appearance Inspection: Check the main unit, control rack, and electrical control cabinet for any damage on the surface.","rel":"","context":"In &quot;Company News&quot;","block_context":{"text":"Company News","link":"https:\/\/zjbocon.com\/?cat=133125"},"img":{"alt_text":"","src":"https:\/\/i0.wp.com\/zjbocon.com\/wp-content\/uploads\/2025\/09\/sterilizer-station-design-2.webp?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/zjbocon.com\/wp-content\/uploads\/2025\/09\/sterilizer-station-design-2.webp?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/zjbocon.com\/wp-content\/uploads\/2025\/09\/sterilizer-station-design-2.webp?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/zjbocon.com\/wp-content\/uploads\/2025\/09\/sterilizer-station-design-2.webp?resize=700%2C400&ssl=1 2x"},"classes":[]}],"_links":{"self":[{"href":"https:\/\/zjbocon.com\/index.php?rest_route=\/wp\/v2\/posts\/8843","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/zjbocon.com\/index.php?rest_route=\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/zjbocon.com\/index.php?rest_route=\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/zjbocon.com\/index.php?rest_route=\/wp\/v2\/users\/234312599"}],"replies":[{"embeddable":true,"href":"https:\/\/zjbocon.com\/index.php?rest_route=%2Fwp%2Fv2%2Fcomments&post=8843"}],"version-history":[{"count":2,"href":"https:\/\/zjbocon.com\/index.php?rest_route=\/wp\/v2\/posts\/8843\/revisions"}],"predecessor-version":[{"id":9631,"href":"https:\/\/zjbocon.com\/index.php?rest_route=\/wp\/v2\/posts\/8843\/revisions\/9631"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/zjbocon.com\/index.php?rest_route=\/wp\/v2\/media\/8182"}],"wp:attachment":[{"href":"https:\/\/zjbocon.com\/index.php?rest_route=%2Fwp%2Fv2%2Fmedia&parent=8843"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/zjbocon.com\/index.php?rest_route=%2Fwp%2Fv2%2Fcategories&post=8843"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/zjbocon.com\/index.php?rest_route=%2Fwp%2Fv2%2Ftags&post=8843"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}