{"id":2471,"date":"2024-12-23T09:49:40","date_gmt":"2024-12-23T01:49:40","guid":{"rendered":"https:\/\/zjbocon.com\/?p=2471"},"modified":"2025-10-01T19:14:06","modified_gmt":"2025-10-01T11:14:06","slug":"safety-requirements-for-using-ethylene-oxide-in-sterilization","status":"publish","type":"post","link":"https:\/\/zjbocon.com\/?p=2471","title":{"rendered":"Safety Requirements for Using Ethylene Oxide in sterilization"},"content":{"rendered":"\n<div class=\"wp-block-uagb-image uagb-block-3a59f9d8 wp-block-uagb-image--layout-default wp-block-uagb-image--effect-static wp-block-uagb-image--align-none\"><figure class=\"wp-block-uagb-image__figure\"><img loading=\"lazy\" decoding=\"async\" src=\"https:\/\/zjbocon.com\/wp-content\/uploads\/2024\/10\/Electrical-Scale.png\" alt=\"\" class=\"uag-image-1673\" width=\"255\" height=\"569\" title=\"Electrical Scale\" role=\"img\" \><\/figure><\/div>\n\n\n\n<ol class=\"wp-block-list\">\n<li>ариутгах камер дахь этилен исэл нь гал түймрээс урьдчилан сэргийлэх төхөөрөмжөөр тоноглогдсон байх ёстой.<\/li>\n\n\n\n<li>Этилений ислийн цилиндрийг тамхи татах, ил гал асаахыг хатуу хориглож, хуурай, агааржуулалт сайтай өрөөнд тусад нь хадгална.<\/li>\n\n\n\n<li>Ариутгалын камерын гэрэлтүүлэг нь тэсрэлтээс хамгаалагдсан байх ёстой бөгөөд цахилгаан оч үүсгэж болзошгүй цахилгаан хэрэгслийг ашиглахаас зайлсхийх хэрэгтэй. Ил гал асаахыг хатуу хориглоно.<\/li>\n\n\n\n<li>Зүйл бүрийг ариутгахаас өмнө GB18279-2000 үндэсний стандартын дагуу параметрүүдийг баталгаажуулах шаардлагатай.<\/li>\n\n\n\n<li>Ариутгагчийн хяналтын хэсгийг үндсэн нэгжээс тусад нь суурилуулсан байх ёстой (диаграм D.1-ийг үз).<\/li>\n\n\n\n<li>Нүүлгэн шилжүүлэх (угаах) үе шат дууссаны дараа ариутгасан эд зүйлсийг битүүмжилсэн ариутгалын камерт 15 минутаас илүү байлгаж болохгүй. Үгүй бол хаалгыг онгойлгохын өмнө нүүлгэн шилжүүлэх үе шатыг давтах ёстой.<\/li>\n\n\n\n<li>Ариутгал дахь этилений исэл дууссаны дараа нүүлгэн шилжүүлэх агаарыг ариутгах үйл ажиллагааны холбогдох журмын дагуу боловсруулах ёстой. Эд зүйлсийг зайлуулахын тулд хаалгыг онгойлгохын өмнө агааржуулалтыг хангахын тулд тэнхлэгийн сэнсийг асаах хэрэгтэй. Ариутгалын камерт хортой үлдэгдэл хийд өртөхгүйн тулд хаалгыг онгойлгосны дараа эд зүйлсийг нэн даруй гаргаж болохгүй.<\/li>\n\n\n\n<li><strong>Эмийн сэрэмжлүүлэг:<\/strong> Эмийн хэмжээнээс хамаарч даралт эсвэл жинг тогтооно. Шаардлагатай тундаа хүрсэн үед дуут дохио дуугарна. Энэ үед оператор эмийн савны унтраалга болон үндсэн нэгжийн тунг тохируулах хавхлагыг нэн даруй хаах ёстой.<\/li>\n\n\n\n<li>Этилений оксидын холимог хийн хэрэглэгчид эмийн савны гаралтын хэсэгт даралт зохицуулагч (хэрэглэгч суулгасан) суурилуулж, лонхны гаралтын даралтыг 0.4 МПа-аас доош буулгаж, өндөр даралтын улмаас тунг дамжуулах хоолойд гоожихоос сэргийлнэ.<\/li>\n\n\n\n<li>Ариутгагч хангамжийн системийн аль нэг хэсгийг салгах, нээхээс өмнө системийг цэвэрлэх шаардлагатай (хийн савны хангамжийн системээс бусад).<\/li>\n\n\n\n<li>Ариутгалын камер дахь хаалганы жийргэвчний агаарын даралт ариутгалын явцад 0.45 МПа-аас бага байвал резинэн битүүмжлэлийн агаарын хангамжийг хааж, резинэн битүүмжлэлийг даралттай байлгахын тулд нөөц даралтын эх үүсвэрийг холбоно. 0.45 МПа-аас их. Үүний зэрэгцээ этилен исэл алдагдсантай харьцах журмыг идэвхжүүлж ариутгах камерыг нүүлгэн шилжүүлэх, цэвэрлэх шаардлагатай. Дараа нь анхны агаарын эх үүсвэрийг сэргээх арга хэмжээ авах хэрэгтэй.<\/li>\n\n\n\n<li>Ажлын байрны агааржуулалтын систем доголдсон тохиолдолд төхөөрөмжийг унтрааж, дахин эхлүүлэхгүй байх шаардлагатай. Хэрэв ариутгагч бодис камерт аль хэдийн нэвтэрсэн байхад алдаа гарвал ариутгагч бодисыг зайлуулах, угаах процедур бүрэн дууссаны дараа ариутгасан эд зүйлстэй холбоо барихын тулд оператор камерт орох ёстой.<\/li>\n\n\n\n<li>Ажлын мөчлөг бүрийн дараа этилен исэл дамжуулах хоолойн системийг цэвэрлэх шаардлагатай. Цэвэрлэх хэрэгсэлд ус, шахсан агаар эсвэл уур орно. Хэрэглэгч ариутгалын хий хуримтлагдаж болзошгүй газруудад, тухайлбал ариутгалын хаалганы ойролцоо, ариутгасан эд зүйлсийг хадгалах газар, ариутгагч бодис хадгалах газар зэрэгт орон нутгийн яндангийн системийг суурилуулах ёстой. Яндангийн систем нь аюул учруулж болзошгүй аливаа бодисыг гадагшлуулахгүй байх ёстой.<\/li>\n<\/ol>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Жич:<\/strong> Тоног төхөөрөмж хэвийн ажиллагаатай, доголдолтой, засвар үйлчилгээ хийж байгаа эсэхээс үл хамааран ажилтнууд ариутгалын камерт орох шаардлагатай бол хаалгыг газарт буулгах эсвэл дэмжих шаардлагатай. Хаалга нь түгжигдсэн, хаах боломжгүй гэдгийг батлах хэрэгтэй. Ажилтнууд танхимд орохоосоо өмнө түлхүүрийг авч эсвэл аюулгүй хадгалах ёстой.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"h-contact\">Холбоо барих<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Утас:<a href=\"https:\/\/wa.me\/8619975258603\">+8619975258603<\/a><\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Имэйл:<a href=\"mailto:hayley@hzbocon.com\">hayley@hzbocon.com<\/a><\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Орон нутгийн сайт: Хятад, Жэжян муж, Ханжоу хот, Шиаша дүүрэг, Кайтон Жүншин, 1202 тоот<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Вэбсайт:<a href=\"https:\/\/www.hzbocon.com\/\">hzbocon.com<\/a><a href=\"https:\/\/zjbocon.com\/\">&nbsp;zjbocon.com<\/a><\/p>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"h-know-more-about-us\">Бидний талаар илүү ихийг мэдэж аваарай<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\"><a href=\"https:\/\/zjbocon.com\/sterilization-for-spice\/\">Халуун ногооны ETO, Гамма, уурын ариутгалыг харьцуулах<\/a><\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><a href=\"https:\/\/zjbocon.com\/understanding-eto-sterilizer-performance-keys-to-efficiency\/\">ETO ариутгагчийн гүйцэтгэлийг ойлгох нь: Үр ашгийн түлхүүрүүд<\/a><\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><a href=\"https:\/\/zjbocon.com\/ethylene-oxide-leak-handling-when-using-eto-sterilizer\/\">Это ариутгагчийг хэрэглэх үед этилен ислийн алдагдлыг зохицуулах<\/a><\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><a href=\"https:\/\/zjbocon.com\/safety-requirements-for-using-ethylene-oxide-in-sterilization\/\">Ариутгалд этилен ислийг ашиглахад тавигдах аюулгүй байдлын шаардлага<\/a><\/p>\n","protected":false},"excerpt":{"rendered":"<p>Note: Regardless of whether the equipment is in normal operation, malfunction, or maintenance state, if personnel need to enter the [&hellip;Гэж]<\/p>\n","protected":false},"author":234312599,"featured_media":1686,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_uag_custom_page_level_css":"","site-sidebar-layout":"default","site-content-layout":"","ast-site-content-layout":"default","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","ast-disable-related-posts":"","theme-transparent-header-meta":"","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"set","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"_jetpack_newsletter_access":"","_jetpack_dont_email_post_to_subs":false,"_jetpack_newsletter_tier_id":0,"_jetpack_memberships_contains_paywalled_content":false,"_jetpack_feature_clip_id":0,"_jetpack_memberships_contains_paid_content":false,"footnotes":"","jetpack_publicize_message":"","jetpack_publicize_feature_enabled":true,"jetpack_social_post_already_shared":false,"jetpack_social_options":{"image_generator_settings":{"template":"highway","enabled":false},"version":2},"jetpack_post_was_ever_published":false},"categories":[133125,133124],"tags":[],"class_list":["post-2471","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-company-news","category-eto-sterilizer"],"yoast_head":"<!-- This site is optimized with the Yoast SEO Premium plugin v27.2 (Yoast SEO v28.0) - https:\/\/yoast.com\/product\/yoast-seo-premium-wordpress\/ -->\n<title>Ариутгалд этилен ислийг ашиглахад тавигдах аюулгүй байдлын шаардлага - ETO стерилизатор<\/title>\n<meta name=\"description\" content=\"The ethylene oxide gas(Ethylene Oxide in sterilization) for the sterilizer should be supplied by dedicated steel cylinders.\" \>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \>\n<link rel=\"canonical\" href=\"https:\/\/zjbocon.com\/?p=2471\" \>\n<meta property=\"og:locale\" content=\"mn_MN\" \>\n<meta property=\"og:type\" content=\"article\" \>\n<meta property=\"og:title\" content=\"Safety Requirements for Using Ethylene Oxide in sterilization\" \>\n<meta property=\"og:description\" content=\"The ethylene oxide gas(Ethylene Oxide in sterilization) for the sterilizer should be supplied by dedicated steel cylinders.\" \>\n<meta property=\"og:url\" content=\"https:\/\/zjbocon.com\/?p=2471\" \>\n<meta property=\"og:site_name\" content=\"ETO STERILIZER\" \>\n<meta property=\"article:publisher\" content=\"https:\/\/www.facebook.com\/profile.php?id=100088482339878\" \>\n<meta property=\"article:author\" content=\"https:\/\/www.facebook.com\/profile.php?id=100088482339878\" \>\n<meta property=\"article:published_time\" content=\"2024-12-23T01:49:40+00:00\" \>\n<meta property=\"article:modified_time\" content=\"2025-10-01T11:14:06+00:00\" \>\n<meta property=\"og:image\" content=\"https:\/\/zjbocon.com\/wp-content\/uploads\/2024\/10\/Electrical-Scale.webp\" \>\n\t<meta property=\"og:image:width\" content=\"255\" \>\n\t<meta property=\"og:image:height\" content=\"569\" \>\n\t<meta property=\"og:image:type\" content=\"image\/webp\" \>\n<meta name=\"author\" content=\"Bocon Technical Team\" \>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \>\n<meta name=\"twitter:creator\" content=\"@BoconAnd\" \>\n<meta name=\"twitter:site\" content=\"@BoconAnd\" \>\n<meta name=\"twitter:label1\" content=\"Written by\" \>\n\t<meta name=\"twitter:data1\" content=\"Bocon Technical Team\" \>\n\t<meta name=\"twitter:label2\" content=\"Est. reading time\" \>\n\t<meta name=\"twitter:data2\" content=\"4 minutes\" \>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\\\/\\\/zjbocon.com\\\/?p=2471#article\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/zjbocon.com\\\/?p=2471\"},\"author\":{\"name\":\"Bocon Technical Team\",\"@id\":\"https:\\\/\\\/zjbocon.com\\\/#\\\/schema\\\/person\\\/f12be028b8ae9843a4396dcc8012b425\"},\"headline\":\"Safety Requirements for Using Ethylene Oxide in sterilization\",\"datePublished\":\"2024-12-23T01:49:40+00:00\",\"dateModified\":\"2025-10-01T11:14:06+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/zjbocon.com\\\/?p=2471\"},\"wordCount\":619,\"commentCount\":0,\"publisher\":{\"@id\":\"https:\\\/\\\/zjbocon.com\\\/#organization\"},\"image\":{\"@id\":\"https:\\\/\\\/zjbocon.com\\\/?p=2471#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/zjbocon.com\\\/wp-content\\\/uploads\\\/2024\\\/10\\\/Electrical-Scale.webp\",\"articleSection\":[\"Company News\",\"ETO STERILIZER\"],\"inLanguage\":\"mn\",\"potentialAction\":[{\"@type\":\"CommentAction\",\"name\":\"Comment\",\"target\":[\"https:\\\/\\\/zjbocon.com\\\/?p=2471#respond\"]}]},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/zjbocon.com\\\/?p=2471\",\"url\":\"https:\\\/\\\/zjbocon.com\\\/?p=2471\",\"name\":\"Safety Requirements for Using Ethylene Oxide in sterilization - ETO STERILIZER\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/zjbocon.com\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/zjbocon.com\\\/?p=2471#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/zjbocon.com\\\/?p=2471#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/zjbocon.com\\\/wp-content\\\/uploads\\\/2024\\\/10\\\/Electrical-Scale.webp\",\"datePublished\":\"2024-12-23T01:49:40+00:00\",\"dateModified\":\"2025-10-01T11:14:06+00:00\",\"description\":\"The ethylene oxide gas(Ethylene Oxide in sterilization) for the sterilizer should be supplied by dedicated ethylene oxide steel cylinders.\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/zjbocon.com\\\/?p=2471#breadcrumb\"},\"inLanguage\":\"mn\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/zjbocon.com\\\/?p=2471\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"mn\",\"@id\":\"https:\\\/\\\/zjbocon.com\\\/?p=2471#primaryimage\",\"url\":\"https:\\\/\\\/zjbocon.com\\\/wp-content\\\/uploads\\\/2024\\\/10\\\/Electrical-Scale.webp\",\"contentUrl\":\"https:\\\/\\\/zjbocon.com\\\/wp-content\\\/uploads\\\/2024\\\/10\\\/Electrical-Scale.webp\",\"width\":255,\"height\":569,\"caption\":\"eo gas\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/zjbocon.com\\\/?p=2471#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/zjbocon.com\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Safety Requirements for Using Ethylene Oxide in sterilization\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/zjbocon.com\\\/#website\",\"url\":\"https:\\\/\\\/zjbocon.com\\\/\",\"name\":\"ETO STERILIZER\",\"description\":\"One-stop Solution Supplier of Ethylene Oxide Sterilization\",\"publisher\":{\"@id\":\"https:\\\/\\\/zjbocon.com\\\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/zjbocon.com\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"mn\"},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/zjbocon.com\\\/#organization\",\"name\":\"ETO STERILIZER\",\"url\":\"https:\\\/\\\/zjbocon.com\\\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"mn\",\"@id\":\"https:\\\/\\\/zjbocon.com\\\/#\\\/schema\\\/logo\\\/image\\\/\",\"url\":\"https:\\\/\\\/zjbocon.com\\\/wp-content\\\/uploads\\\/2024\\\/10\\\/logo-1.webp\",\"contentUrl\":\"https:\\\/\\\/zjbocon.com\\\/wp-content\\\/uploads\\\/2024\\\/10\\\/logo-1.webp\",\"width\":180,\"height\":60,\"caption\":\"ETO STERILIZER\"},\"image\":{\"@id\":\"https:\\\/\\\/zjbocon.com\\\/#\\\/schema\\\/logo\\\/image\\\/\"},\"sameAs\":[\"https:\\\/\\\/www.facebook.com\\\/profile.php?id=100088482339878\",\"https:\\\/\\\/x.com\\\/BoconAnd\",\"https:\\\/\\\/www.linkedin.com\\\/in\\\/--06a221139\\\/\"]},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/zjbocon.com\\\/#\\\/schema\\\/person\\\/f12be028b8ae9843a4396dcc8012b425\",\"name\":\"Bocon Technical Team\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"mn\",\"@id\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/d7a825658be227f26b237e519f8541e05aabc9ff27b8eec4544a233a48c53be0?s=96&d=identicon&r=g\",\"url\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/d7a825658be227f26b237e519f8541e05aabc9ff27b8eec4544a233a48c53be0?s=96&d=identicon&r=g\",\"contentUrl\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/d7a825658be227f26b237e519f8541e05aabc9ff27b8eec4544a233a48c53be0?s=96&d=identicon&r=g\",\"caption\":\"Bocon Technical Team\"},\"sameAs\":[\"https:\\\/\\\/zjbocon.com\\\/\",\"https:\\\/\\\/www.facebook.com\\\/profile.php?id=100088482339878\",\"https:\\\/\\\/www.linkedin.com\\\/in\\\/\\\/hayley--968190269\\\/\"],\"url\":\"https:\\\/\\\/zjbocon.com\\\/?author=234312599\"}]}<\/script>\n<!-- \/ Yoast SEO Premium plugin. -->","yoast_head_json":{"title":"Safety Requirements for Using Ethylene Oxide in sterilization - ETO STERILIZER","description":"The ethylene oxide gas(Ethylene Oxide in sterilization) for the sterilizer should be supplied by dedicated ethylene oxide steel cylinders.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/zjbocon.com\/?p=2471","og_locale":"mn_MN","og_type":"article","og_title":"Safety Requirements for Using Ethylene Oxide in sterilization","og_description":"The ethylene oxide gas(Ethylene Oxide in sterilization) for the sterilizer should be supplied by dedicated ethylene oxide steel cylinders.","og_url":"https:\/\/zjbocon.com\/?p=2471","og_site_name":"ETO STERILIZER","article_publisher":"https:\/\/www.facebook.com\/profile.php?id=100088482339878","article_author":"https:\/\/www.facebook.com\/profile.php?id=100088482339878","article_published_time":"2024-12-23T01:49:40+00:00","article_modified_time":"2025-10-01T11:14:06+00:00","og_image":[{"width":255,"height":569,"url":"https:\/\/zjbocon.com\/wp-content\/uploads\/2024\/10\/Electrical-Scale.webp","type":"image\/webp"}],"author":"Bocon Technical Team","twitter_card":"summary_large_image","twitter_creator":"@BoconAnd","twitter_site":"@BoconAnd","twitter_misc":{"Written by":"Bocon Technical Team","Est. reading time":"4 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/zjbocon.com\/?p=2471#article","isPartOf":{"@id":"https:\/\/zjbocon.com\/?p=2471"},"author":{"name":"Bocon Technical Team","@id":"https:\/\/zjbocon.com\/#\/schema\/person\/f12be028b8ae9843a4396dcc8012b425"},"headline":"Safety Requirements for Using Ethylene Oxide in sterilization","datePublished":"2024-12-23T01:49:40+00:00","dateModified":"2025-10-01T11:14:06+00:00","mainEntityOfPage":{"@id":"https:\/\/zjbocon.com\/?p=2471"},"wordCount":619,"commentCount":0,"publisher":{"@id":"https:\/\/zjbocon.com\/#organization"},"image":{"@id":"https:\/\/zjbocon.com\/?p=2471#primaryimage"},"thumbnailUrl":"https:\/\/zjbocon.com\/wp-content\/uploads\/2024\/10\/Electrical-Scale.webp","articleSection":["Company News","ETO STERILIZER"],"inLanguage":"mn","potentialAction":[{"@type":"CommentAction","name":"Comment","target":["https:\/\/zjbocon.com\/?p=2471#respond"]}]},{"@type":"WebPage","@id":"https:\/\/zjbocon.com\/?p=2471","url":"https:\/\/zjbocon.com\/?p=2471","name":"Safety Requirements for Using Ethylene Oxide in sterilization - ETO STERILIZER","isPartOf":{"@id":"https:\/\/zjbocon.com\/#website"},"primaryImageOfPage":{"@id":"https:\/\/zjbocon.com\/?p=2471#primaryimage"},"image":{"@id":"https:\/\/zjbocon.com\/?p=2471#primaryimage"},"thumbnailUrl":"https:\/\/zjbocon.com\/wp-content\/uploads\/2024\/10\/Electrical-Scale.webp","datePublished":"2024-12-23T01:49:40+00:00","dateModified":"2025-10-01T11:14:06+00:00","description":"The ethylene oxide gas(Ethylene Oxide in sterilization) for the sterilizer should be supplied by dedicated ethylene oxide steel cylinders.","breadcrumb":{"@id":"https:\/\/zjbocon.com\/?p=2471#breadcrumb"},"inLanguage":"mn","potentialAction":[{"@type":"ReadAction","target":["https:\/\/zjbocon.com\/?p=2471"]}]},{"@type":"ImageObject","inLanguage":"mn","@id":"https:\/\/zjbocon.com\/?p=2471#primaryimage","url":"https:\/\/zjbocon.com\/wp-content\/uploads\/2024\/10\/Electrical-Scale.webp","contentUrl":"https:\/\/zjbocon.com\/wp-content\/uploads\/2024\/10\/Electrical-Scale.webp","width":255,"height":569,"caption":"eo gas"},{"@type":"BreadcrumbList","@id":"https:\/\/zjbocon.com\/?p=2471#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/zjbocon.com\/"},{"@type":"ListItem","position":2,"name":"Safety Requirements for Using Ethylene Oxide in sterilization"}]},{"@type":"WebSite","@id":"https:\/\/zjbocon.com\/#website","url":"https:\/\/zjbocon.com\/","name":"ETO STERILIZER","description":"One-stop Solution Supplier of Ethylene Oxide Sterilization","publisher":{"@id":"https:\/\/zjbocon.com\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/zjbocon.com\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"mn"},{"@type":"Organization","@id":"https:\/\/zjbocon.com\/#organization","name":"ETO STERILIZER","url":"https:\/\/zjbocon.com\/","logo":{"@type":"ImageObject","inLanguage":"mn","@id":"https:\/\/zjbocon.com\/#\/schema\/logo\/image\/","url":"https:\/\/zjbocon.com\/wp-content\/uploads\/2024\/10\/logo-1.webp","contentUrl":"https:\/\/zjbocon.com\/wp-content\/uploads\/2024\/10\/logo-1.webp","width":180,"height":60,"caption":"ETO STERILIZER"},"image":{"@id":"https:\/\/zjbocon.com\/#\/schema\/logo\/image\/"},"sameAs":["https:\/\/www.facebook.com\/profile.php?id=100088482339878","https:\/\/x.com\/BoconAnd","https:\/\/www.linkedin.com\/in\/--06a221139\/"]},{"@type":"Person","@id":"https:\/\/zjbocon.com\/#\/schema\/person\/f12be028b8ae9843a4396dcc8012b425","name":"Bocon Technical Team","image":{"@type":"ImageObject","inLanguage":"mn","@id":"https:\/\/secure.gravatar.com\/avatar\/d7a825658be227f26b237e519f8541e05aabc9ff27b8eec4544a233a48c53be0?s=96&d=identicon&r=g","url":"https:\/\/secure.gravatar.com\/avatar\/d7a825658be227f26b237e519f8541e05aabc9ff27b8eec4544a233a48c53be0?s=96&d=identicon&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/d7a825658be227f26b237e519f8541e05aabc9ff27b8eec4544a233a48c53be0?s=96&d=identicon&r=g","caption":"Bocon Technical Team"},"sameAs":["https:\/\/zjbocon.com\/","https:\/\/www.facebook.com\/profile.php?id=100088482339878","https:\/\/www.linkedin.com\/in\/\/hayley--968190269\/"],"url":"https:\/\/zjbocon.com\/?author=234312599"}]}},"jetpack_publicize_connections":[],"jetpack_featured_media_url":"https:\/\/zjbocon.com\/wp-content\/uploads\/2024\/10\/Electrical-Scale.webp","uagb_featured_image_src":{"full":["https:\/\/zjbocon.com\/wp-content\/uploads\/2024\/10\/Electrical-Scale.webp",255,569,false],"thumbnail":["https:\/\/zjbocon.com\/wp-content\/uploads\/2024\/10\/Electrical-Scale-150x150.webp",150,150,true],"medium":["https:\/\/zjbocon.com\/wp-content\/uploads\/2024\/10\/Electrical-Scale-134x300.webp",134,300,true],"medium_large":["https:\/\/zjbocon.com\/wp-content\/uploads\/2024\/10\/Electrical-Scale.webp",255,569,false],"large":["https:\/\/zjbocon.com\/wp-content\/uploads\/2024\/10\/Electrical-Scale.webp",255,569,false],"1536x1536":["https:\/\/zjbocon.com\/wp-content\/uploads\/2024\/10\/Electrical-Scale.webp",255,569,false],"2048x2048":["https:\/\/zjbocon.com\/wp-content\/uploads\/2024\/10\/Electrical-Scale.webp",255,569,false],"woocommerce_thumbnail":["https:\/\/zjbocon.com\/wp-content\/uploads\/2024\/10\/Electrical-Scale.webp",255,569,false],"woocommerce_single":["https:\/\/zjbocon.com\/wp-content\/uploads\/2024\/10\/Electrical-Scale.webp",255,569,false],"woocommerce_gallery_thumbnail":["https:\/\/zjbocon.com\/wp-content\/uploads\/2024\/10\/Electrical-Scale-100x100.webp",100,100,true]},"uagb_author_info":{"display_name":"Bocon Technical Team","author_link":"https:\/\/zjbocon.com\/?author=234312599"},"uagb_comment_info":0,"uagb_excerpt":"Note: Regardless of whether the equipment is in normal operation, malfunction, or maintenance state, if personnel need to enter the [&hellip;]","jetpack_likes_enabled":true,"jetpack_sharing_enabled":true,"jetpack_shortlink":"https:\/\/wp.me\/pgZDV6-DR","jetpack-related-posts":[{"id":2476,"url":"https:\/\/zjbocon.com\/?p=2476","url_meta":{"origin":2471,"position":0},"title":"Ethylene Oxide Leak Handling when using eto sterilizer","author":"Bocon Technical Team","date":"2024-12-23","format":false,"excerpt":"If a leak is detected in the eto sterilizer dosing pipeline during the administration process, immediately close the medication bottle, switch and the dosing valve on the main unit. Turn on the axial fan to ensure proper ventilation, and then proceed with repairs.","rel":"","context":"In &quot;Company News&quot;","block_context":{"text":"Company News","link":"https:\/\/zjbocon.com\/?cat=133125"},"img":{"alt_text":"","src":"https:\/\/i0.wp.com\/zjbocon.com\/wp-content\/uploads\/2025\/09\/ethylene-oxide-sterilization-19-scaled.webp?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/zjbocon.com\/wp-content\/uploads\/2025\/09\/ethylene-oxide-sterilization-19-scaled.webp?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/zjbocon.com\/wp-content\/uploads\/2025\/09\/ethylene-oxide-sterilization-19-scaled.webp?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/zjbocon.com\/wp-content\/uploads\/2025\/09\/ethylene-oxide-sterilization-19-scaled.webp?resize=700%2C400&ssl=1 2x, https:\/\/i0.wp.com\/zjbocon.com\/wp-content\/uploads\/2025\/09\/ethylene-oxide-sterilization-19-scaled.webp?resize=1050%2C600&ssl=1 3x, https:\/\/i0.wp.com\/zjbocon.com\/wp-content\/uploads\/2025\/09\/ethylene-oxide-sterilization-19-scaled.webp?resize=1400%2C800&ssl=1 4x"},"classes":[]},{"id":8958,"url":"https:\/\/zjbocon.com\/?p=8958","url_meta":{"origin":2471,"position":1},"title":"Understanding What is ETO Sterilizers: A Comprehensive Guide","author":"Bocon Technical Team","date":"2025-12-16","format":false,"excerpt":"Discover the essentials of ETO sterilizers and ethylene oxide sterilization, ensuring the highest hygiene standards in healthcare and beyond.","rel":"","context":"In &quot;Company News&quot;","block_context":{"text":"Company News","link":"https:\/\/zjbocon.com\/?cat=133125"},"img":{"alt_text":"","src":"https:\/\/i0.wp.com\/zjbocon.com\/wp-content\/uploads\/2024\/11\/eto-sterilizer-hzbocon-3.png?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/zjbocon.com\/wp-content\/uploads\/2024\/11\/eto-sterilizer-hzbocon-3.png?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/zjbocon.com\/wp-content\/uploads\/2024\/11\/eto-sterilizer-hzbocon-3.png?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/zjbocon.com\/wp-content\/uploads\/2024\/11\/eto-sterilizer-hzbocon-3.png?resize=700%2C400&ssl=1 2x, https:\/\/i0.wp.com\/zjbocon.com\/wp-content\/uploads\/2024\/11\/eto-sterilizer-hzbocon-3.png?resize=1050%2C600&ssl=1 3x"},"classes":[]},{"id":3093,"url":"https:\/\/zjbocon.com\/?p=3093","url_meta":{"origin":2471,"position":2},"title":"Introduction to Ethylene Oxide Sterilizers","author":"Bocon Technical Team","date":"2025-02-05","format":false,"excerpt":"Discover how ethylene oxide sterilizers work, their applications, benefits, and safety considerations. Learn why they are essential for medical and industrial sterilization.","rel":"","context":"In &quot;Company News&quot;","block_context":{"text":"Company News","link":"https:\/\/zjbocon.com\/?cat=133125"},"img":{"alt_text":"","src":"https:\/\/i0.wp.com\/zjbocon.com\/wp-content\/uploads\/2024\/11\/ethylene-oxide-sterilization-21.webp?resize=350%2C200","width":350,"height":200},"classes":[]},{"id":2453,"url":"https:\/\/zjbocon.com\/?p=2453","url_meta":{"origin":2471,"position":3},"title":"Microbial Killing Performance of Ethylene Oxide Sterilizers","author":"Bocon Technical Team","date":"2024-12-20","format":false,"excerpt":"Note 1: The Ethylene Oxide sterilization conditions must be obtained through validation confirmation and should be verified with monitoring and routine control during each sterilization cycle. The requirements for validation and routine control are outlined in GB 18279. Note 2: This testing method is also applicable to A class Ethylene\u2026","rel":"","context":"In &quot;Company News&quot;","block_context":{"text":"Company News","link":"https:\/\/zjbocon.com\/?cat=133125"},"img":{"alt_text":"eto sterilizer","src":"https:\/\/i0.wp.com\/zjbocon.com\/wp-content\/uploads\/2024\/10\/banner__.webp?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/zjbocon.com\/wp-content\/uploads\/2024\/10\/banner__.webp?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/zjbocon.com\/wp-content\/uploads\/2024\/10\/banner__.webp?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/zjbocon.com\/wp-content\/uploads\/2024\/10\/banner__.webp?resize=700%2C400&ssl=1 2x"},"classes":[]},{"id":2448,"url":"https:\/\/zjbocon.com\/?p=2448","url_meta":{"origin":2471,"position":4},"title":"eto sterilization Chamber Temperature Distribution Testing","author":"Bocon Technical Team","date":"2024-12-20","format":false,"excerpt":"The temperature of representative areas on the inner surfaces should be measured and recorded using temperature recording instruments that comply with the requirements of Appendix B.","rel":"","context":"In &quot;Company News&quot;","block_context":{"text":"Company News","link":"https:\/\/zjbocon.com\/?cat=133125"},"img":{"alt_text":"","src":"https:\/\/i0.wp.com\/zjbocon.com\/wp-content\/uploads\/2025\/09\/ethylene-oxide-sterilization-54.webp?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/zjbocon.com\/wp-content\/uploads\/2025\/09\/ethylene-oxide-sterilization-54.webp?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/zjbocon.com\/wp-content\/uploads\/2025\/09\/ethylene-oxide-sterilization-54.webp?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/zjbocon.com\/wp-content\/uploads\/2025\/09\/ethylene-oxide-sterilization-54.webp?resize=700%2C400&ssl=1 2x, https:\/\/i0.wp.com\/zjbocon.com\/wp-content\/uploads\/2025\/09\/ethylene-oxide-sterilization-54.webp?resize=1050%2C600&ssl=1 3x"},"classes":[]},{"id":2439,"url":"https:\/\/zjbocon.com\/?p=2439","url_meta":{"origin":2471,"position":5},"title":"Preparatory Work Before eto Sterilization","author":"Bocon Technical Team","date":"2024-12-17","format":false,"excerpt":"Appearance Inspection: Check the main unit, control rack, and electrical control cabinet for any damage on the surface.","rel":"","context":"In &quot;Company News&quot;","block_context":{"text":"Company News","link":"https:\/\/zjbocon.com\/?cat=133125"},"img":{"alt_text":"","src":"https:\/\/i0.wp.com\/zjbocon.com\/wp-content\/uploads\/2025\/09\/sterilizer-station-design-2.webp?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/zjbocon.com\/wp-content\/uploads\/2025\/09\/sterilizer-station-design-2.webp?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/zjbocon.com\/wp-content\/uploads\/2025\/09\/sterilizer-station-design-2.webp?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/zjbocon.com\/wp-content\/uploads\/2025\/09\/sterilizer-station-design-2.webp?resize=700%2C400&ssl=1 2x"},"classes":[]}],"_links":{"self":[{"href":"https:\/\/zjbocon.com\/index.php?rest_route=\/wp\/v2\/posts\/2471","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/zjbocon.com\/index.php?rest_route=\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/zjbocon.com\/index.php?rest_route=\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/zjbocon.com\/index.php?rest_route=\/wp\/v2\/users\/234312599"}],"replies":[{"embeddable":true,"href":"https:\/\/zjbocon.com\/index.php?rest_route=%2Fwp%2Fv2%2Fcomments&post=2471"}],"version-history":[{"count":5,"href":"https:\/\/zjbocon.com\/index.php?rest_route=\/wp\/v2\/posts\/2471\/revisions"}],"predecessor-version":[{"id":2499,"href":"https:\/\/zjbocon.com\/index.php?rest_route=\/wp\/v2\/posts\/2471\/revisions\/2499"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/zjbocon.com\/index.php?rest_route=\/wp\/v2\/media\/1686"}],"wp:attachment":[{"href":"https:\/\/zjbocon.com\/index.php?rest_route=%2Fwp%2Fv2%2Fmedia&parent=2471"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/zjbocon.com\/index.php?rest_route=%2Fwp%2Fv2%2Fcategories&post=2471"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/zjbocon.com\/index.php?rest_route=%2Fwp%2Fv2%2Ftags&post=2471"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}