{"id":2018,"date":"2024-10-28T11:23:57","date_gmt":"2024-10-28T03:23:57","guid":{"rendered":"https:\/\/zjbocon.com\/?p=2018"},"modified":"2024-11-06T14:09:44","modified_gmt":"2024-11-06T06:09:44","slug":"eto-sterilizer-system","status":"publish","type":"post","link":"https:\/\/zjbocon.com\/?p=2018","title":{"rendered":"Protection function OF eTO chamber SYSTEM"},"content":{"rendered":"\n<p class=\"wp-block-paragraph\"> <\/p>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"h-protection-mechanism-and-explanation-of-eto-sterilizer-system\">Mekkaniżmu ta &#039;protezzjoni u spjegazzjoni TAS-Sistema ta&#039; Sterilizzatur ETO<\/h2>\n\n\n\n<div class=\"wp-block-uagb-image uagb-block-dba6a8eb wp-block-uagb-image--layout-default wp-block-uagb-image--effect-static wp-block-uagb-image--align-none\"><figure class=\"wp-block-uagb-image__figure\"><a class=\"\" href=\"https:\/\/zjbocon.com\/product\/sterilizer-control-system\/\" target=\"\" rel=\"noopener\"><img loading=\"lazy\" decoding=\"async\" src=\"https:\/\/zjbocon.com\/wp-content\/uploads\/2024\/10\/Ethylene-Oxide-Sterilizer-Control-System-5.webp\" alt=\"Ethylene Oxide Sterilizer Control System (5)\" class=\"uag-image-1277\" width=\"616\" height=\"786\" title=\"Ethylene role =\"img\" \><\/a><\/figure><\/div>\n\n\n\n<ol class=\"wp-block-list\">\n<li>Is-sistema ta &#039;sterilizzatur ETO għandha sitt livelli differenti ta&#039; permessi ta &#039;tħaddim. Persunal b&#039;permessi differenti jista&#039; jopera kontenut differenti biex jipprevjeni l-konfużjoni ta&#039; tħaddim, jew ħsara fit-tagħmir jew inċident tas-sigurtà kkawżat minn tħaddim minn persunal mingħajr taħriġ professjonali<\/li>\n<\/ol>\n\n\n\n<p class=\"wp-block-paragraph\">2. B&#039;mod awtomatiku, is-sistema se twettaq it-test ta &#039;skoperta ta&#039; tnixxija qabel id-dożaġġ ta &#039;kull lott. Jekk it-test tas-sejbien tat-tnixxija jfalli, is-sistema awtomatikament twaqqaf iċ-ċiklu u ma tibqax tkompli, u l-allarm iħeġġeġ<\/p>\n\n\n\n<div class=\"wp-block-uagb-image uagb-block-1cf2e572 wp-block-uagb-image--layout-default wp-block-uagb-image--effect-static wp-block-uagb-image--align-none\"><figure class=\"wp-block-uagb-image__figure\"><img loading=\"lazy\" decoding=\"async\" src=\"https:\/\/zjbocon.com\/wp-content\/uploads\/2024\/10\/4.-leak-testing.webp\" alt=\"\" class=\"uag-image-1015\" width=\"719\" height=\"544\" title=\"4. leak testing\" role=\"img\" \><\/figure><\/div>\n\n\n\n<p class=\"wp-block-paragraph\">3.Jekk il-korp tal-kabinett joħroġ matul l-istadju ta &#039;espożizzjoni tat-tagħmir, is-Sistema tal-kamra ETO se taqbeż awtomatikament għall-istadju tat-tindif biex tiżgura li l-EO ma jnixxix fil-workshop u tikkawża inċidenti ta&#039; sikurezza<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">4. Meta t-tagħmir ikun qed jaħdem, jekk irid iwaqqaf iċ-ċiklu fin-nofs, is-sistema awtomatikament taqbeż għal proċess ta &#039;proċessar sikur skont kundizzjonijiet operattivi differenti. Pereżempju, wara d-dożaġġ, is-sistema teħtieġ tindif sfurzat biex tirrisettja l-proċess kollu.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">5. Jekk is-sistema hija mgħammra bi skala elettronika, sakemm it-tagħmir ikun mixgħul, tista &#039;tiċċekkja jekk il-piż taċ-ċilindru EO jinbidelx b&#039;mod anormali fi kwalunkwe ħin, sabiex tinnotifika f&#039;waqtu lill-persunal tal-manutenzjoni tat-tagħmir dwar perikli potenzjali għas-sigurtà.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">6. Is-Sistema tal-kamra ETO għandha l-funzjoni ta &#039;skoperta u protezzjoni ta&#039; pressjoni ultra-għolja. Jekk is-sistema tiskopri li l-pressjoni fil-kabinett hija akbar mill-pressjoni massima permissibbli, kemm jekk it-tagħmir ikun qed jaħdem jew le, il-pompa tal-vakwu għandha tkun sfurzata tibda tnaqqas il-pressjoni fil-kabinett biex tevita li l-gass fil-kabinett joħroġ fil-workshop, jew il-kabinett ikun bil-ħsara mill-pressjoni għolja fil-kabinett<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">7.Kull darba li jinfetaħ il-bieb, is-Sistema tal-kamra tal-ETO se tivverifika jekk il-pressjoni fil-kabinett hijiex fil-medda sikura, u jekk l-istat tal-operazzjoni fil-kabinett huwiex fl-istat sikur, inkella l-bieb ikun imsakkar u ma jistax jinfetaħ<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">8.Sabiex tiġi żgurata s-sigurtà personali, it-tagħmir jista &#039;jkun mgħammar b&#039;sistema ta&#039; exhaust li ma tagħmilx ħsara. Wara li jinfetaħ il-bieb tal-kabinett, kun żgur li l-arja fil-workshop tista &#039;tidħol biss fil-kabinett, iżda ma tistax tiġi skarikata mill-kabinett għall-ambjent tal-workshop<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">9.Jekk it-tagħmir ikun ġie mnaddaf iżda l-bieb ma nfetaħx, is-sistema awtomatikament tiċċekkja l-ħin tal-ħatt. Jekk il-ħin tal-ħatt ikun aktar minn 30 minuta, il-bieb ikun imsakkar u ma jistax jinfetaħ, u l-proċess tat-tindif għandu jerġa &#039;jiġi eżegwit. Din il-funzjoni tintuża biex tiżgura li l-EO fil-prodott mhux se jiġi rilaxxat bil-mod fl-ambjent tal-workshop, u jikkawża tniġġis fl-ambjent tal-workshop u ħsara għas-saħħa personali<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">10.Is-sistema kollha ta &#039;kontroll għandha funzjoni ta&#039; awto-dijanjosi għal kull tip ta &#039;tagħmir u sensuri, li tintuża biex tipprevjeni t-tħaddim anormali tat-tagħmir f&#039;każ ta&#039; falliment tas-sensuri, u fl-istess ħin tħeġġeġ lill-persunal tal-manutenzjoni liema sensor jew tagħmir falla, sabiex il-persunal tal-manutenzjoni jkun jista &#039;malajr isib u jsolvi problemi<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">11.Is-SISTEMA ta &#039;sterilizzatur ETO għandha aktar minn 100 informazzjoni dwar tort u allarm, li tippermetti lill-operaturi u lill-persunal tal-manutenzjoni jkunu jafu l-operat tat-tagħmir f&#039;waqtu u preċiż, sabiex il-persunal tal-manutenzjoni jkun jista&#039; jsib u jsolvi l-problemi malajr.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">12.Wara t-tniżżil tal-parametri tal-proċess, jekk ikun hemm parametri mhux raġonevoli, se jkun hemm fil-pront ta &#039;falliment tat-tniżżil biex jipprevjeni l-operazzjoni tal-lott kollu milli tfalli meta l-parametri ma jkunux raġonevoli<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">13.Wara t-tniżżil tal-parametri tal-proċess, jekk ikun hemm parametri mhux raġonevoli, se jkun hemm fil-pront ta &#039;falliment tat-tniżżil biex jipprevjeni l-operazzjoni tal-lott kollu milli tfalli meta l-parametri ma jkunux raġonevoli<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">14. F&#039;każ ta &#039;telf ta&#039; provvista ta &#039;enerġija esterna, UPS se jkompli jforni l-enerġija lis-sistema, u t-tagħmir se jittratta l-istat sospiż biex jiżgura li t-tagħmir ma jnixxix wara nuqqas ta&#039; enerġija, u jiżgura ħin ta &#039;buffer ta&#039; sigurtà ta &#039;mill-inqas 15-il minuta. Wara li t-tagħmir jingħalaq permezz tal-proċess ta &#039;tħaddim normali, it-tagħmir xorta jista&#039; jkompli jaħdem meta l-enerġija esterna tiġi restawrata<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">15.Meta l-IPC jonqos matul l-operazzjoni tas-sistema, l-IPC jista &#039;jerġa&#039; jinbeda direttament, u s-softwer jista &#039;jgħaqqad awtomatikament ir-rekord oriġinali<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">16.Is-sistema għandha funzjoni ta &#039;traċċar ta&#039; verifika dettaljata, li tista &#039;tirreġistra l-azzjonijiet ta&#039; operazzjoni kważi kollha għall-konvenjenza tal-analiżi tal-inċidenti u l-prevenzjoni tal-ħsarat fl-istadju aktar tard<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"h-contact\">Kuntatt<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Telefon:<a href=\"https:\/\/wa.me\/8619975258603\">+8619975258603<\/a><\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Email:<a href=\"mailto:hayley@hzbocon.com\">hayley@hzbocon.com<\/a><\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Sit Lokali: Kamra 1202, Caitong Zhongxin, Distrett Xiasha, Belt Hangzhou, Provinċja ta &#039;Zhejiang, Ċina<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Websajt:<a href=\"https:\/\/www.hzbocon.com\/\">hzbocon.com<\/a><a href=\"https:\/\/zjbocon.com\/\">zjbocon.com<\/a><\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><\/p>\n","protected":false},"excerpt":{"rendered":"<p>Protection mechanism and explanation OF ETO Sterilizer System 2. By default, the system will perform the leak detection test before [&hellip;]<\/p>\n","protected":false},"author":234312599,"featured_media":1889,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_uag_custom_page_level_css":"","site-sidebar-layout":"default","site-content-layout":"","ast-site-content-layout":"default","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","ast-disable-related-posts":"","theme-transparent-header-meta":"","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"set","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"_jetpack_newsletter_access":"","_jetpack_dont_email_post_to_subs":false,"_jetpack_newsletter_tier_id":0,"_jetpack_memberships_contains_paywalled_content":false,"_jetpack_feature_clip_id":0,"_jetpack_memberships_contains_paid_content":false,"footnotes":"","jetpack_publicize_message":"","jetpack_publicize_feature_enabled":true,"jetpack_social_post_already_shared":false,"jetpack_social_options":{"image_generator_settings":{"template":"highway","enabled":false},"version":2},"jetpack_post_was_ever_published":false},"categories":[133124],"tags":[],"class_list":["post-2018","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-eto-sterilizer"],"yoast_head":"<!-- This site is optimized with the Yoast SEO Premium plugin v27.2 (Yoast SEO v28.0) - https:\/\/yoast.com\/product\/yoast-seo-premium-wordpress\/ -->\n<title>Funzjoni ta &#039;protezzjoni TAS-SISTEMA tal-kamra tal-eTO - ETO STERILIZER<\/title>\n<meta name=\"description\" content=\"ETO chamber System (The ETO sterilizer system )has six different levels of operation permissions. Personnel with permissions\" \>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \>\n<link rel=\"canonical\" href=\"https:\/\/zjbocon.com\/?p=2018\" \>\n<meta property=\"og:locale\" content=\"mt_MT\" \>\n<meta property=\"og:type\" content=\"article\" \>\n<meta property=\"og:title\" content=\"Protection function OF eTO chamber SYSTEM\" \>\n<meta property=\"og:description\" content=\"ETO chamber System (The ETO sterilizer system )has six different levels of operation permissions. Personnel with permissions\" \>\n<meta property=\"og:url\" content=\"https:\/\/zjbocon.com\/?p=2018\" \>\n<meta property=\"og:site_name\" content=\"ETO STERILIZER\" \>\n<meta property=\"article:publisher\" content=\"https:\/\/www.facebook.com\/profile.php?id=100088482339878\" \>\n<meta property=\"article:author\" content=\"https:\/\/www.facebook.com\/profile.php?id=100088482339878\" \>\n<meta property=\"article:published_time\" content=\"2024-10-28T03:23:57+00:00\" \>\n<meta property=\"article:modified_time\" content=\"2024-11-06T06:09:44+00:00\" \>\n<meta property=\"og:image\" content=\"https:\/\/zjbocon.com\/wp-content\/uploads\/2024\/10\/customer_5.webp\" \>\n\t<meta property=\"og:image:width\" content=\"300\" \>\n\t<meta property=\"og:image:height\" content=\"200\" \>\n\t<meta property=\"og:image:type\" content=\"image\/webp\" \>\n<meta name=\"author\" content=\"Bocon Technical Team\" \>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \>\n<meta name=\"twitter:creator\" content=\"@BoconAnd\" \>\n<meta name=\"twitter:site\" content=\"@BoconAnd\" \>\n<meta name=\"twitter:label1\" content=\"Written by\" \>\n\t<meta name=\"twitter:data1\" content=\"Bocon Technical Team\" \>\n\t<meta name=\"twitter:label2\" content=\"Est. reading time\" \>\n\t<meta name=\"twitter:data2\" content=\"4 minutes\" \>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\\\/\\\/zjbocon.com\\\/?p=2018#article\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/zjbocon.com\\\/?p=2018\"},\"author\":{\"name\":\"Bocon Technical Team\",\"@id\":\"https:\\\/\\\/zjbocon.com\\\/#\\\/schema\\\/person\\\/f12be028b8ae9843a4396dcc8012b425\"},\"headline\":\"Protection function OF eTO chamber SYSTEM\",\"datePublished\":\"2024-10-28T03:23:57+00:00\",\"dateModified\":\"2024-11-06T06:09:44+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/zjbocon.com\\\/?p=2018\"},\"wordCount\":765,\"commentCount\":0,\"publisher\":{\"@id\":\"https:\\\/\\\/zjbocon.com\\\/#organization\"},\"image\":{\"@id\":\"https:\\\/\\\/zjbocon.com\\\/?p=2018#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/zjbocon.com\\\/wp-content\\\/uploads\\\/2024\\\/10\\\/customer_5.webp\",\"articleSection\":[\"ETO STERILIZER\"],\"inLanguage\":\"mt\",\"potentialAction\":[{\"@type\":\"CommentAction\",\"name\":\"Comment\",\"target\":[\"https:\\\/\\\/zjbocon.com\\\/?p=2018#respond\"]}]},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/zjbocon.com\\\/?p=2018\",\"url\":\"https:\\\/\\\/zjbocon.com\\\/?p=2018\",\"name\":\"Protection function OF eTO chamber SYSTEM - ETO STERILIZER\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/zjbocon.com\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/zjbocon.com\\\/?p=2018#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/zjbocon.com\\\/?p=2018#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/zjbocon.com\\\/wp-content\\\/uploads\\\/2024\\\/10\\\/customer_5.webp\",\"datePublished\":\"2024-10-28T03:23:57+00:00\",\"dateModified\":\"2024-11-06T06:09:44+00:00\",\"description\":\"ETO chamber System (The ETO sterilizer system )has six different levels of operation permissions. Personnel with different permissions\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/zjbocon.com\\\/?p=2018#breadcrumb\"},\"inLanguage\":\"mt\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/zjbocon.com\\\/?p=2018\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"mt\",\"@id\":\"https:\\\/\\\/zjbocon.com\\\/?p=2018#primaryimage\",\"url\":\"https:\\\/\\\/zjbocon.com\\\/wp-content\\\/uploads\\\/2024\\\/10\\\/customer_5.webp\",\"contentUrl\":\"https:\\\/\\\/zjbocon.com\\\/wp-content\\\/uploads\\\/2024\\\/10\\\/customer_5.webp\",\"width\":300,\"height\":200},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/zjbocon.com\\\/?p=2018#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/zjbocon.com\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Protection function OF eTO chamber SYSTEM\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/zjbocon.com\\\/#website\",\"url\":\"https:\\\/\\\/zjbocon.com\\\/\",\"name\":\"ETO STERILIZER\",\"description\":\"One-stop Solution Supplier of Ethylene Oxide Sterilization\",\"publisher\":{\"@id\":\"https:\\\/\\\/zjbocon.com\\\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/zjbocon.com\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"mt\"},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/zjbocon.com\\\/#organization\",\"name\":\"ETO STERILIZER\",\"url\":\"https:\\\/\\\/zjbocon.com\\\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"mt\",\"@id\":\"https:\\\/\\\/zjbocon.com\\\/#\\\/schema\\\/logo\\\/image\\\/\",\"url\":\"https:\\\/\\\/zjbocon.com\\\/wp-content\\\/uploads\\\/2024\\\/10\\\/logo-1.webp\",\"contentUrl\":\"https:\\\/\\\/zjbocon.com\\\/wp-content\\\/uploads\\\/2024\\\/10\\\/logo-1.webp\",\"width\":180,\"height\":60,\"caption\":\"ETO STERILIZER\"},\"image\":{\"@id\":\"https:\\\/\\\/zjbocon.com\\\/#\\\/schema\\\/logo\\\/image\\\/\"},\"sameAs\":[\"https:\\\/\\\/www.facebook.com\\\/profile.php?id=100088482339878\",\"https:\\\/\\\/x.com\\\/BoconAnd\",\"https:\\\/\\\/www.linkedin.com\\\/in\\\/--06a221139\\\/\"]},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/zjbocon.com\\\/#\\\/schema\\\/person\\\/f12be028b8ae9843a4396dcc8012b425\",\"name\":\"Bocon Technical Team\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"mt\",\"@id\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/d7a825658be227f26b237e519f8541e05aabc9ff27b8eec4544a233a48c53be0?s=96&d=identicon&r=g\",\"url\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/d7a825658be227f26b237e519f8541e05aabc9ff27b8eec4544a233a48c53be0?s=96&d=identicon&r=g\",\"contentUrl\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/d7a825658be227f26b237e519f8541e05aabc9ff27b8eec4544a233a48c53be0?s=96&d=identicon&r=g\",\"caption\":\"Bocon Technical Team\"},\"sameAs\":[\"https:\\\/\\\/zjbocon.com\\\/\",\"https:\\\/\\\/www.facebook.com\\\/profile.php?id=100088482339878\",\"https:\\\/\\\/www.linkedin.com\\\/in\\\/\\\/hayley--968190269\\\/\"],\"url\":\"https:\\\/\\\/zjbocon.com\\\/?author=234312599\"}]}<\/script>\n<!-- \/ Yoast SEO Premium plugin. -->","yoast_head_json":{"title":"Protection function OF eTO chamber SYSTEM - ETO STERILIZER","description":"ETO chamber System (The ETO sterilizer system )has six different levels of operation permissions. Personnel with different permissions","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/zjbocon.com\/?p=2018","og_locale":"mt_MT","og_type":"article","og_title":"Protection function OF eTO chamber SYSTEM","og_description":"ETO chamber System (The ETO sterilizer system )has six different levels of operation permissions. Personnel with different permissions","og_url":"https:\/\/zjbocon.com\/?p=2018","og_site_name":"ETO STERILIZER","article_publisher":"https:\/\/www.facebook.com\/profile.php?id=100088482339878","article_author":"https:\/\/www.facebook.com\/profile.php?id=100088482339878","article_published_time":"2024-10-28T03:23:57+00:00","article_modified_time":"2024-11-06T06:09:44+00:00","og_image":[{"width":300,"height":200,"url":"https:\/\/zjbocon.com\/wp-content\/uploads\/2024\/10\/customer_5.webp","type":"image\/webp"}],"author":"Bocon Technical Team","twitter_card":"summary_large_image","twitter_creator":"@BoconAnd","twitter_site":"@BoconAnd","twitter_misc":{"Written by":"Bocon Technical Team","Est. reading time":"4 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/zjbocon.com\/?p=2018#article","isPartOf":{"@id":"https:\/\/zjbocon.com\/?p=2018"},"author":{"name":"Bocon Technical Team","@id":"https:\/\/zjbocon.com\/#\/schema\/person\/f12be028b8ae9843a4396dcc8012b425"},"headline":"Protection function OF eTO chamber SYSTEM","datePublished":"2024-10-28T03:23:57+00:00","dateModified":"2024-11-06T06:09:44+00:00","mainEntityOfPage":{"@id":"https:\/\/zjbocon.com\/?p=2018"},"wordCount":765,"commentCount":0,"publisher":{"@id":"https:\/\/zjbocon.com\/#organization"},"image":{"@id":"https:\/\/zjbocon.com\/?p=2018#primaryimage"},"thumbnailUrl":"https:\/\/zjbocon.com\/wp-content\/uploads\/2024\/10\/customer_5.webp","articleSection":["ETO STERILIZER"],"inLanguage":"mt","potentialAction":[{"@type":"CommentAction","name":"Comment","target":["https:\/\/zjbocon.com\/?p=2018#respond"]}]},{"@type":"WebPage","@id":"https:\/\/zjbocon.com\/?p=2018","url":"https:\/\/zjbocon.com\/?p=2018","name":"Protection function OF eTO chamber SYSTEM - ETO STERILIZER","isPartOf":{"@id":"https:\/\/zjbocon.com\/#website"},"primaryImageOfPage":{"@id":"https:\/\/zjbocon.com\/?p=2018#primaryimage"},"image":{"@id":"https:\/\/zjbocon.com\/?p=2018#primaryimage"},"thumbnailUrl":"https:\/\/zjbocon.com\/wp-content\/uploads\/2024\/10\/customer_5.webp","datePublished":"2024-10-28T03:23:57+00:00","dateModified":"2024-11-06T06:09:44+00:00","description":"ETO chamber System (The ETO sterilizer system )has six different levels of operation permissions. Personnel with different permissions","breadcrumb":{"@id":"https:\/\/zjbocon.com\/?p=2018#breadcrumb"},"inLanguage":"mt","potentialAction":[{"@type":"ReadAction","target":["https:\/\/zjbocon.com\/?p=2018"]}]},{"@type":"ImageObject","inLanguage":"mt","@id":"https:\/\/zjbocon.com\/?p=2018#primaryimage","url":"https:\/\/zjbocon.com\/wp-content\/uploads\/2024\/10\/customer_5.webp","contentUrl":"https:\/\/zjbocon.com\/wp-content\/uploads\/2024\/10\/customer_5.webp","width":300,"height":200},{"@type":"BreadcrumbList","@id":"https:\/\/zjbocon.com\/?p=2018#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/zjbocon.com\/"},{"@type":"ListItem","position":2,"name":"Protection function OF eTO chamber SYSTEM"}]},{"@type":"WebSite","@id":"https:\/\/zjbocon.com\/#website","url":"https:\/\/zjbocon.com\/","name":"ETO STERILIZER","description":"One-stop Solution Supplier of Ethylene Oxide Sterilization","publisher":{"@id":"https:\/\/zjbocon.com\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/zjbocon.com\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"mt"},{"@type":"Organization","@id":"https:\/\/zjbocon.com\/#organization","name":"ETO STERILIZER","url":"https:\/\/zjbocon.com\/","logo":{"@type":"ImageObject","inLanguage":"mt","@id":"https:\/\/zjbocon.com\/#\/schema\/logo\/image\/","url":"https:\/\/zjbocon.com\/wp-content\/uploads\/2024\/10\/logo-1.webp","contentUrl":"https:\/\/zjbocon.com\/wp-content\/uploads\/2024\/10\/logo-1.webp","width":180,"height":60,"caption":"ETO STERILIZER"},"image":{"@id":"https:\/\/zjbocon.com\/#\/schema\/logo\/image\/"},"sameAs":["https:\/\/www.facebook.com\/profile.php?id=100088482339878","https:\/\/x.com\/BoconAnd","https:\/\/www.linkedin.com\/in\/--06a221139\/"]},{"@type":"Person","@id":"https:\/\/zjbocon.com\/#\/schema\/person\/f12be028b8ae9843a4396dcc8012b425","name":"Bocon Technical Team","image":{"@type":"ImageObject","inLanguage":"mt","@id":"https:\/\/secure.gravatar.com\/avatar\/d7a825658be227f26b237e519f8541e05aabc9ff27b8eec4544a233a48c53be0?s=96&d=identicon&r=g","url":"https:\/\/secure.gravatar.com\/avatar\/d7a825658be227f26b237e519f8541e05aabc9ff27b8eec4544a233a48c53be0?s=96&d=identicon&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/d7a825658be227f26b237e519f8541e05aabc9ff27b8eec4544a233a48c53be0?s=96&d=identicon&r=g","caption":"Bocon Technical Team"},"sameAs":["https:\/\/zjbocon.com\/","https:\/\/www.facebook.com\/profile.php?id=100088482339878","https:\/\/www.linkedin.com\/in\/\/hayley--968190269\/"],"url":"https:\/\/zjbocon.com\/?author=234312599"}]}},"jetpack_publicize_connections":[],"jetpack_featured_media_url":"https:\/\/zjbocon.com\/wp-content\/uploads\/2024\/10\/customer_5.webp","uagb_featured_image_src":{"full":["https:\/\/zjbocon.com\/wp-content\/uploads\/2024\/10\/customer_5.webp",300,200,false],"thumbnail":["https:\/\/zjbocon.com\/wp-content\/uploads\/2024\/10\/customer_5-150x150.webp",150,150,true],"medium":["https:\/\/zjbocon.com\/wp-content\/uploads\/2024\/10\/customer_5.webp",300,200,false],"medium_large":["https:\/\/zjbocon.com\/wp-content\/uploads\/2024\/10\/customer_5.webp",300,200,false],"large":["https:\/\/zjbocon.com\/wp-content\/uploads\/2024\/10\/customer_5.webp",300,200,false],"1536x1536":["https:\/\/zjbocon.com\/wp-content\/uploads\/2024\/10\/customer_5.webp",300,200,false],"2048x2048":["https:\/\/zjbocon.com\/wp-content\/uploads\/2024\/10\/customer_5.webp",300,200,false],"woocommerce_thumbnail":["https:\/\/zjbocon.com\/wp-content\/uploads\/2024\/10\/customer_5.webp",300,200,false],"woocommerce_single":["https:\/\/zjbocon.com\/wp-content\/uploads\/2024\/10\/customer_5.webp",300,200,false],"woocommerce_gallery_thumbnail":["https:\/\/zjbocon.com\/wp-content\/uploads\/2024\/10\/customer_5-100x100.webp",100,100,true]},"uagb_author_info":{"display_name":"Bocon Technical Team","author_link":"https:\/\/zjbocon.com\/?author=234312599"},"uagb_comment_info":23,"uagb_excerpt":"Protection mechanism and explanation OF ETO Sterilizer System 2. By default, the system will perform the leak detection test before [&hellip;]","jetpack_likes_enabled":true,"jetpack_sharing_enabled":true,"jetpack_shortlink":"https:\/\/wp.me\/pgZDV6-wy","jetpack-related-posts":[{"id":2492,"url":"https:\/\/zjbocon.com\/?p=2492","url_meta":{"origin":2018,"position":0},"title":"Understanding ETO Sterilizer Performance: Keys to Efficiency","author":"Bocon Technical Team","date":"2024-12-24","format":false,"excerpt":"3.4.1 eto sterilizer machine Temperature Setting Range The temperature setting range for the eto sterilizer is: 30 to 70\u00b0C","rel":"","context":"In &quot;Company News&quot;","block_context":{"text":"Company News","link":"https:\/\/zjbocon.com\/?cat=133125"},"img":{"alt_text":"","src":"https:\/\/i0.wp.com\/zjbocon.com\/wp-content\/uploads\/2025\/09\/eto-sterilizer-1.webp?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/zjbocon.com\/wp-content\/uploads\/2025\/09\/eto-sterilizer-1.webp?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/zjbocon.com\/wp-content\/uploads\/2025\/09\/eto-sterilizer-1.webp?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/zjbocon.com\/wp-content\/uploads\/2025\/09\/eto-sterilizer-1.webp?resize=700%2C400&ssl=1 2x, https:\/\/i0.wp.com\/zjbocon.com\/wp-content\/uploads\/2025\/09\/eto-sterilizer-1.webp?resize=1050%2C600&ssl=1 3x"},"classes":[]},{"id":9255,"url":"https:\/\/zjbocon.com\/?p=9255","url_meta":{"origin":2018,"position":1},"title":"Featured System: The Bocon ETO Sterilizer Series","author":"Bocon Technical Team","date":"2026-02-06","format":false,"excerpt":"PHASE 01 PHASE 02 PHASE 03 PHASE 04 PHASE 05 Industrial Grade ETO Sterilization Solutions Explore Bocon ETO Sterilizer Details ? Why Leading Manufacturers Integrate Bocon Systems: Looking to upgrade your sterilization capacity? Explore the Technical Specifications of the Bocon ETO Sterilizer Series ? Headline: From Logistics to Operational Readiness:\u2026","rel":"","context":"In &quot;ETO STERILIZER&quot;","block_context":{"text":"ETO STERILIZER","link":"https:\/\/zjbocon.com\/?cat=133124"},"img":{"alt_text":"","src":"https:\/\/i0.wp.com\/zjbocon.com\/wp-content\/uploads\/2026\/02\/Featured-System-The-Bocon-ETO-Sterilizer-Series-1.webp?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/zjbocon.com\/wp-content\/uploads\/2026\/02\/Featured-System-The-Bocon-ETO-Sterilizer-Series-1.webp?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/zjbocon.com\/wp-content\/uploads\/2026\/02\/Featured-System-The-Bocon-ETO-Sterilizer-Series-1.webp?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/zjbocon.com\/wp-content\/uploads\/2026\/02\/Featured-System-The-Bocon-ETO-Sterilizer-Series-1.webp?resize=700%2C400&ssl=1 2x, https:\/\/i0.wp.com\/zjbocon.com\/wp-content\/uploads\/2026\/02\/Featured-System-The-Bocon-ETO-Sterilizer-Series-1.webp?resize=1050%2C600&ssl=1 3x, https:\/\/i0.wp.com\/zjbocon.com\/wp-content\/uploads\/2026\/02\/Featured-System-The-Bocon-ETO-Sterilizer-Series-1.webp?resize=1400%2C800&ssl=1 4x"},"classes":[]},{"id":2064,"url":"https:\/\/zjbocon.com\/?p=2064","url_meta":{"origin":2018,"position":2},"title":"OQ IN ETO STERILIZATION MACHINE","author":"Bocon Technical Team","date":"2024-10-31","format":false,"excerpt":"In OQ, the performance of the relevant auxiliary system should be determined and the software system should be tested by simulating the fault conditions.","rel":"","context":"In &quot;ETO STERILIZER&quot;","block_context":{"text":"ETO STERILIZER","link":"https:\/\/zjbocon.com\/?cat=133124"},"img":{"alt_text":"","src":"https:\/\/i0.wp.com\/zjbocon.com\/wp-content\/uploads\/2025\/09\/Ethylene-Oxide-Sterilizer-Installation-Guide-1-scaled.webp?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/zjbocon.com\/wp-content\/uploads\/2025\/09\/Ethylene-Oxide-Sterilizer-Installation-Guide-1-scaled.webp?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/zjbocon.com\/wp-content\/uploads\/2025\/09\/Ethylene-Oxide-Sterilizer-Installation-Guide-1-scaled.webp?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/zjbocon.com\/wp-content\/uploads\/2025\/09\/Ethylene-Oxide-Sterilizer-Installation-Guide-1-scaled.webp?resize=700%2C400&ssl=1 2x, https:\/\/i0.wp.com\/zjbocon.com\/wp-content\/uploads\/2025\/09\/Ethylene-Oxide-Sterilizer-Installation-Guide-1-scaled.webp?resize=1050%2C600&ssl=1 3x, https:\/\/i0.wp.com\/zjbocon.com\/wp-content\/uploads\/2025\/09\/Ethylene-Oxide-Sterilizer-Installation-Guide-1-scaled.webp?resize=1400%2C800&ssl=1 4x"},"classes":[]},{"id":2094,"url":"https:\/\/zjbocon.com\/?p=2094","url_meta":{"origin":2018,"position":3},"title":"ETO Sterilizer Manufacturer-HZBOCON","author":"Bocon Technical Team","date":"2024-11-04","format":false,"excerpt":"Hangzhou Bocon Mechanical and Electrical Equipment Co., Ltd., commonly referred to as HZBOCON, stands out as a dedicated Ethylene Oxide (EO\/ETO) sterilizer manufacturer. Established in 2006, HZBOCON has committed itself to the design, development, and manufacturing of EO sterilization equipment, catering to a wide array of industries that require effective\u2026","rel":"","context":"In &quot;ETO STERILIZER&quot;","block_context":{"text":"ETO STERILIZER","link":"https:\/\/zjbocon.com\/?cat=133124"},"img":{"alt_text":"","src":"https:\/\/i0.wp.com\/zjbocon.com\/wp-content\/uploads\/2024\/11\/eto-sterilizer-hzbocon-4.png?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/zjbocon.com\/wp-content\/uploads\/2024\/11\/eto-sterilizer-hzbocon-4.png?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/zjbocon.com\/wp-content\/uploads\/2024\/11\/eto-sterilizer-hzbocon-4.png?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/zjbocon.com\/wp-content\/uploads\/2024\/11\/eto-sterilizer-hzbocon-4.png?resize=700%2C400&ssl=1 2x, https:\/\/i0.wp.com\/zjbocon.com\/wp-content\/uploads\/2024\/11\/eto-sterilizer-hzbocon-4.png?resize=1050%2C600&ssl=1 3x"},"classes":[]},{"id":2534,"url":"https:\/\/zjbocon.com\/?p=2534","url_meta":{"origin":2018,"position":4},"title":"How to Loading Sterilization product when using eto gas sterilizer","author":"Bocon Technical Team","date":"2024-12-27","format":false,"excerpt":"Sterilizer-chamber-conveyor Sterilizer-chamber-conveyor Sterilizer-chamber-conveyor 8.4.1 Closing the eto gas sterilizer Discharge Door For double-door eto gas sterilizer, before loading sterilization goods, follow the closing procedure for the discharge door, and inflate the sealing gasket of the discharge door until the pressure reaches above 0.45 MPa to ensure a proper seal. Manually\u2026","rel":"","context":"In &quot;Company News&quot;","block_context":{"text":"Company News","link":"https:\/\/zjbocon.com\/?cat=133125"},"img":{"alt_text":"","src":"https:\/\/i0.wp.com\/zjbocon.com\/wp-content\/uploads\/2025\/09\/Automatic-Sterilizer-Chamber-Conveyor-1.webp?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/zjbocon.com\/wp-content\/uploads\/2025\/09\/Automatic-Sterilizer-Chamber-Conveyor-1.webp?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/zjbocon.com\/wp-content\/uploads\/2025\/09\/Automatic-Sterilizer-Chamber-Conveyor-1.webp?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/zjbocon.com\/wp-content\/uploads\/2025\/09\/Automatic-Sterilizer-Chamber-Conveyor-1.webp?resize=700%2C400&ssl=1 2x"},"classes":[]},{"id":2117,"url":"https:\/\/zjbocon.com\/?p=2117","url_meta":{"origin":2018,"position":5},"title":"Industry Eto Sterilizer Installation Verification","author":"Bocon Technical Team","date":"2024-11-06","format":false,"excerpt":"Industry Eto Sterilizer Installation Verification The installation of Industry Eto Sterilizer and all associated services should comply with the requirements of the construction and engineering drawings. It is recommended to verify the components of the Industry Eto Sterilizer to ensure the installation meets applicable standards and requirements. These equipment components\u2026","rel":"","context":"In &quot;ETO STERILIZER&quot;","block_context":{"text":"ETO STERILIZER","link":"https:\/\/zjbocon.com\/?cat=133124"},"img":{"alt_text":"","src":"https:\/\/i0.wp.com\/zjbocon.com\/wp-content\/uploads\/2024\/10\/sterilizer-station-design-2.webp?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/zjbocon.com\/wp-content\/uploads\/2024\/10\/sterilizer-station-design-2.webp?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/zjbocon.com\/wp-content\/uploads\/2024\/10\/sterilizer-station-design-2.webp?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/zjbocon.com\/wp-content\/uploads\/2024\/10\/sterilizer-station-design-2.webp?resize=700%2C400&ssl=1 2x"},"classes":[]}],"_links":{"self":[{"href":"https:\/\/zjbocon.com\/index.php?rest_route=\/wp\/v2\/posts\/2018","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/zjbocon.com\/index.php?rest_route=\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/zjbocon.com\/index.php?rest_route=\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/zjbocon.com\/index.php?rest_route=\/wp\/v2\/users\/234312599"}],"replies":[{"embeddable":true,"href":"https:\/\/zjbocon.com\/index.php?rest_route=%2Fwp%2Fv2%2Fcomments&post=2018"}],"version-history":[{"count":12,"href":"https:\/\/zjbocon.com\/index.php?rest_route=\/wp\/v2\/posts\/2018\/revisions"}],"predecessor-version":[{"id":2030,"href":"https:\/\/zjbocon.com\/index.php?rest_route=\/wp\/v2\/posts\/2018\/revisions\/2030"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/zjbocon.com\/index.php?rest_route=\/wp\/v2\/media\/1889"}],"wp:attachment":[{"href":"https:\/\/zjbocon.com\/index.php?rest_route=%2Fwp%2Fv2%2Fmedia&parent=2018"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/zjbocon.com\/index.php?rest_route=%2Fwp%2Fv2%2Fcategories&post=2018"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/zjbocon.com\/index.php?rest_route=%2Fwp%2Fv2%2Ftags&post=2018"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}