{"id":2471,"date":"2024-12-23T09:49:40","date_gmt":"2024-12-23T01:49:40","guid":{"rendered":"https:\/\/zjbocon.com\/?p=2471"},"modified":"2025-10-01T19:14:06","modified_gmt":"2025-10-01T11:14:06","slug":"safety-requirements-for-using-ethylene-oxide-in-sterilization","status":"publish","type":"post","link":"https:\/\/zjbocon.com\/?p=2471","title":{"rendered":"Safety Requirements for Using Ethylene Oxide in sterilization"},"content":{"rendered":"\n<div class=\"wp-block-uagb-image uagb-block-3a59f9d8 wp-block-uagb-image--layout-default wp-block-uagb-image--effect-static wp-block-uagb-image--align-none\"><figure class=\"wp-block-uagb-image__figure\"><img loading=\"lazy\" decoding=\"async\" src=\"https:\/\/zjbocon.com\/wp-content\/uploads\/2024\/10\/Electrical-Scale.png\" alt=\"\" class=\"uag-image-1673\" width=\"255\" height=\"569\" title=\"Electrical Scale\" role=\"img\" \><\/figure><\/div>\n\n\n\n<ol class=\"wp-block-list\">\n<li>when Ethylene Oxide in sterilization chamber should be equipped with fire prevention facilities.<\/li>\n\n\n\n<li>Ethylene oxide cylinders should be stored separately in a dry, well-ventilated room, with strict prohibition of smoking and open flames.<\/li>\n\n\n\n<li>The lighting in the sterilization chamber should be explosion-proof, and any electrical appliances that may cause electric sparks should be avoided. Open flames are strictly prohibited.<\/li>\n\n\n\n<li>Before sterilizing each type of item, the parameters must be confirmed according to the national standard GB18279-2000.<\/li>\n\n\n\n<li>The control section of the sterilizer should be installed separately from the main unit (see diagram D.1).<\/li>\n\n\n\n<li>After the displacement (flushing) phase is completed, the sterilized items should not remain in the sealed sterilization chamber for more than 15 minutes. Otherwise, the displacement phase must be repeated before opening the door.<\/li>\n\n\n\n<li>After Ethylene Oxide in sterilization is complete, the displacement air must be processed according to the relevant sterilization operation regulations. Before opening the door to remove the items, the axial fan should be turned on to ensure ventilation. Do not immediately take out the items after opening the door to avoid exposure to harmful residual gases in the sterilization chamber.<\/li>\n\n\n\n<li><strong>Medication Alert:<\/strong> Based on the amount of medication to be administered, set the pressure or weight. When the required dosage is reached, an audible alert will sound. At this point, the operator must immediately close the medication bottle switch and the main unit&#8217;s dosing valve.<\/li>\n\n\n\n<li>Users of ethylene oxide mixed gases must install a pressure regulator (user-installed) at the outlet of the medication bottle to reduce the bottle outlet pressure to below 0.4 MPa, preventing high pressure from causing leaks in the dosing pipeline.<\/li>\n\n\n\n<li>Before disconnecting or opening any part of the sterilant supply system, it is necessary to clean the system (except for the gas tank supply system).<\/li>\n\n\n\n<li>If the air pressure of the door seal gasket in the sterilization chamber falls below 0.45 MPa during the sterilization process, the air supply to the rubber seal should be shut off, and a backup pressure source should be connected to ensure the rubber seal has a pressure greater than 0.45 MPa. At the same time, the ethylene oxide leak handling procedure should be activated to evacuate and clean the sterilization chamber. Then, measures should be taken to restore the original air source.<\/li>\n\n\n\n<li>If the workplace ventilation system fails, the equipment should be shut down and not restarted. If the failure occurs while the sterilizing agent has already entered the chamber, the operator should only enter the chamber to contact the sterilized items after the sterilant removal and flushing procedures have been fully completed.<\/li>\n\n\n\n<li>After each work cycle, the ethylene oxide pipeline system should be cleaned. Cleaning media can include water, compressed air, or steam. The user should install local exhaust systems in areas where sterilizing gas may accumulate, such as near the sterilizer door, the storage area for sterilized items, and the sterilant storage area. The exhaust system should not discharge any substances that could cause danger.<\/li>\n<\/ol>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>नोट:<\/strong> Regardless of whether the equipment is in normal operation, malfunction, or maintenance state, if personnel need to enter the sterilizer chamber, the door must be lowered to the ground or supported. It should be confirmed that the door is locked and cannot be closed. Personnel should take or safely store the key before entering the chamber.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"h-contact\">सम्पर्क गर्नुहोस्<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">फोन:<a href=\"https:\/\/wa.me\/8619975258603\">+८६१९९७५२५८६०३<\/a><\/p>\n\n\n\n<p class=\"wp-block-paragraph\">इमेल:<a href=\"mailto:hayley@hzbocon.com\">hayley@hzbocon.com<\/a><\/p>\n\n\n\n<p class=\"wp-block-paragraph\">स्थानीय साइट: कोठा 1202, Caitong Zhongxin, Xiasha जिल्ला, Hangzhou शहर, Zhejiang प्रान्त, चीन<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">वेबसाइट:<a href=\"https:\/\/www.hzbocon.com\/\">hzbocon.com<\/a><a href=\"https:\/\/zjbocon.com\/\">&nbsp;zjbocon.com<\/a><\/p>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"h-know-more-about-us\">Know more about us<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\"><a href=\"https:\/\/zjbocon.com\/sterilization-for-spice\/\">ETO, गामा, र मसलाका लागि स्टीम नसबंदी तुलना<\/a><\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><a href=\"https:\/\/zjbocon.com\/understanding-eto-sterilizer-performance-keys-to-efficiency\/\">ETO स्टेरिलाइजर प्रदर्शन बुझ्दै: दक्षताको कुञ्जी<\/a><\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><a href=\"https:\/\/zjbocon.com\/ethylene-oxide-leak-handling-when-using-eto-sterilizer\/\">ईटो स्टेरिलाइजर प्रयोग गर्दा इथिलीन अक्साइड लीक ह्यान्डलिंग<\/a><\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><a href=\"https:\/\/zjbocon.com\/safety-requirements-for-using-ethylene-oxide-in-sterilization\/\">नसबंदीमा इथिलीन अक्साइड प्रयोग गर्नका लागि सुरक्षा आवश्यकताहरू<\/a><\/p>\n","protected":false},"excerpt":{"rendered":"<p>Note: Regardless of whether the equipment is in normal operation, malfunction, or maintenance state, if personnel need to enter the [&hellip;]<\/p>\n","protected":false},"author":234312599,"featured_media":1686,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_uag_custom_page_level_css":"","site-sidebar-layout":"default","site-content-layout":"","ast-site-content-layout":"default","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","ast-disable-related-posts":"","theme-transparent-header-meta":"","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"set","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"_jetpack_newsletter_access":"","_jetpack_dont_email_post_to_subs":false,"_jetpack_newsletter_tier_id":0,"_jetpack_memberships_contains_paywalled_content":false,"_jetpack_feature_clip_id":0,"_jetpack_memberships_contains_paid_content":false,"footnotes":"","jetpack_publicize_message":"","jetpack_publicize_feature_enabled":true,"jetpack_social_post_already_shared":false,"jetpack_social_options":{"image_generator_settings":{"template":"highway","enabled":false},"version":2},"jetpack_post_was_ever_published":false},"categories":[133125,133124],"tags":[],"class_list":["post-2471","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-company-news","category-eto-sterilizer"],"yoast_head":"<!-- This site is optimized with the Yoast SEO Premium plugin v27.2 (Yoast SEO v28.0) - https:\/\/yoast.com\/product\/yoast-seo-premium-wordpress\/ -->\n<title>Safety Requirements for Using Ethylene Oxide in sterilization - ETO STERILIZER<\/title>\n<meta name=\"description\" content=\"The ethylene oxide gas(Ethylene Oxide in sterilization) for the sterilizer should be supplied by dedicated steel cylinders.\" \>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \>\n<link rel=\"canonical\" href=\"https:\/\/zjbocon.com\/?p=2471\" \>\n<meta property=\"og:locale\" content=\"ne_NP\" \>\n<meta property=\"og:type\" content=\"article\" \>\n<meta property=\"og:title\" content=\"Safety Requirements for Using Ethylene Oxide in sterilization\" \>\n<meta property=\"og:description\" content=\"The ethylene oxide gas(Ethylene Oxide in sterilization) for the sterilizer should be supplied by dedicated steel cylinders.\" \>\n<meta property=\"og:url\" content=\"https:\/\/zjbocon.com\/?p=2471\" \>\n<meta property=\"og:site_name\" content=\"ETO STERILIZER\" \>\n<meta property=\"article:publisher\" content=\"https:\/\/www.facebook.com\/profile.php?id=100088482339878\" \>\n<meta property=\"article:author\" content=\"https:\/\/www.facebook.com\/profile.php?id=100088482339878\" \>\n<meta property=\"article:published_time\" content=\"2024-12-23T01:49:40+00:00\" \>\n<meta property=\"article:modified_time\" content=\"2025-10-01T11:14:06+00:00\" \>\n<meta property=\"og:image\" content=\"https:\/\/zjbocon.com\/wp-content\/uploads\/2024\/10\/Electrical-Scale.webp\" \>\n\t<meta property=\"og:image:width\" content=\"255\" \>\n\t<meta property=\"og:image:height\" content=\"569\" \>\n\t<meta property=\"og:image:type\" content=\"image\/webp\" \>\n<meta name=\"author\" content=\"Bocon Technical Team\" \>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \>\n<meta name=\"twitter:creator\" content=\"@BoconAnd\" \>\n<meta name=\"twitter:site\" content=\"@BoconAnd\" \>\n<meta name=\"twitter:label1\" content=\"Written by\" \>\n\t<meta name=\"twitter:data1\" content=\"Bocon Technical Team\" \>\n\t<meta name=\"twitter:label2\" content=\"Est. reading time\" \>\n\t<meta name=\"twitter:data2\" content=\"4 minutes\" \>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\\\/\\\/zjbocon.com\\\/?p=2471#article\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/zjbocon.com\\\/?p=2471\"},\"author\":{\"name\":\"Bocon Technical Team\",\"@id\":\"https:\\\/\\\/zjbocon.com\\\/#\\\/schema\\\/person\\\/f12be028b8ae9843a4396dcc8012b425\"},\"headline\":\"Safety Requirements for Using Ethylene Oxide in sterilization\",\"datePublished\":\"2024-12-23T01:49:40+00:00\",\"dateModified\":\"2025-10-01T11:14:06+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/zjbocon.com\\\/?p=2471\"},\"wordCount\":619,\"commentCount\":0,\"publisher\":{\"@id\":\"https:\\\/\\\/zjbocon.com\\\/#organization\"},\"image\":{\"@id\":\"https:\\\/\\\/zjbocon.com\\\/?p=2471#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/zjbocon.com\\\/wp-content\\\/uploads\\\/2024\\\/10\\\/Electrical-Scale.webp\",\"articleSection\":[\"Company News\",\"ETO STERILIZER\"],\"inLanguage\":\"ne-NP\",\"potentialAction\":[{\"@type\":\"CommentAction\",\"name\":\"Comment\",\"target\":[\"https:\\\/\\\/zjbocon.com\\\/?p=2471#respond\"]}]},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/zjbocon.com\\\/?p=2471\",\"url\":\"https:\\\/\\\/zjbocon.com\\\/?p=2471\",\"name\":\"Safety Requirements for Using Ethylene Oxide in sterilization - ETO STERILIZER\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/zjbocon.com\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/zjbocon.com\\\/?p=2471#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/zjbocon.com\\\/?p=2471#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/zjbocon.com\\\/wp-content\\\/uploads\\\/2024\\\/10\\\/Electrical-Scale.webp\",\"datePublished\":\"2024-12-23T01:49:40+00:00\",\"dateModified\":\"2025-10-01T11:14:06+00:00\",\"description\":\"The ethylene oxide gas(Ethylene Oxide in sterilization) for the sterilizer should be supplied by dedicated ethylene oxide steel cylinders.\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/zjbocon.com\\\/?p=2471#breadcrumb\"},\"inLanguage\":\"ne-NP\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/zjbocon.com\\\/?p=2471\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"ne-NP\",\"@id\":\"https:\\\/\\\/zjbocon.com\\\/?p=2471#primaryimage\",\"url\":\"https:\\\/\\\/zjbocon.com\\\/wp-content\\\/uploads\\\/2024\\\/10\\\/Electrical-Scale.webp\",\"contentUrl\":\"https:\\\/\\\/zjbocon.com\\\/wp-content\\\/uploads\\\/2024\\\/10\\\/Electrical-Scale.webp\",\"width\":255,\"height\":569,\"caption\":\"eo gas\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/zjbocon.com\\\/?p=2471#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/zjbocon.com\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Safety Requirements for Using Ethylene Oxide in sterilization\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/zjbocon.com\\\/#website\",\"url\":\"https:\\\/\\\/zjbocon.com\\\/\",\"name\":\"ETO STERILIZER\",\"description\":\"One-stop Solution Supplier of Ethylene Oxide Sterilization\",\"publisher\":{\"@id\":\"https:\\\/\\\/zjbocon.com\\\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/zjbocon.com\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"ne-NP\"},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/zjbocon.com\\\/#organization\",\"name\":\"ETO STERILIZER\",\"url\":\"https:\\\/\\\/zjbocon.com\\\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"ne-NP\",\"@id\":\"https:\\\/\\\/zjbocon.com\\\/#\\\/schema\\\/logo\\\/image\\\/\",\"url\":\"https:\\\/\\\/zjbocon.com\\\/wp-content\\\/uploads\\\/2024\\\/10\\\/logo-1.webp\",\"contentUrl\":\"https:\\\/\\\/zjbocon.com\\\/wp-content\\\/uploads\\\/2024\\\/10\\\/logo-1.webp\",\"width\":180,\"height\":60,\"caption\":\"ETO STERILIZER\"},\"image\":{\"@id\":\"https:\\\/\\\/zjbocon.com\\\/#\\\/schema\\\/logo\\\/image\\\/\"},\"sameAs\":[\"https:\\\/\\\/www.facebook.com\\\/profile.php?id=100088482339878\",\"https:\\\/\\\/x.com\\\/BoconAnd\",\"https:\\\/\\\/www.linkedin.com\\\/in\\\/--06a221139\\\/\"]},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/zjbocon.com\\\/#\\\/schema\\\/person\\\/f12be028b8ae9843a4396dcc8012b425\",\"name\":\"Bocon Technical Team\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"ne-NP\",\"@id\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/d7a825658be227f26b237e519f8541e05aabc9ff27b8eec4544a233a48c53be0?s=96&d=identicon&r=g\",\"url\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/d7a825658be227f26b237e519f8541e05aabc9ff27b8eec4544a233a48c53be0?s=96&d=identicon&r=g\",\"contentUrl\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/d7a825658be227f26b237e519f8541e05aabc9ff27b8eec4544a233a48c53be0?s=96&d=identicon&r=g\",\"caption\":\"Bocon Technical Team\"},\"sameAs\":[\"https:\\\/\\\/zjbocon.com\\\/\",\"https:\\\/\\\/www.facebook.com\\\/profile.php?id=100088482339878\",\"https:\\\/\\\/www.linkedin.com\\\/in\\\/\\\/hayley--968190269\\\/\"],\"url\":\"https:\\\/\\\/zjbocon.com\\\/?author=234312599\"}]}<\/script>\n<!-- \/ Yoast SEO Premium plugin. -->","yoast_head_json":{"title":"Safety Requirements for Using Ethylene Oxide in sterilization - ETO STERILIZER","description":"The ethylene oxide gas(Ethylene Oxide in sterilization) for the sterilizer should be supplied by dedicated ethylene oxide steel cylinders.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/zjbocon.com\/?p=2471","og_locale":"ne_NP","og_type":"article","og_title":"Safety Requirements for Using Ethylene Oxide in sterilization","og_description":"The ethylene oxide gas(Ethylene Oxide in sterilization) for the sterilizer should be supplied by dedicated ethylene oxide steel cylinders.","og_url":"https:\/\/zjbocon.com\/?p=2471","og_site_name":"ETO STERILIZER","article_publisher":"https:\/\/www.facebook.com\/profile.php?id=100088482339878","article_author":"https:\/\/www.facebook.com\/profile.php?id=100088482339878","article_published_time":"2024-12-23T01:49:40+00:00","article_modified_time":"2025-10-01T11:14:06+00:00","og_image":[{"width":255,"height":569,"url":"https:\/\/zjbocon.com\/wp-content\/uploads\/2024\/10\/Electrical-Scale.webp","type":"image\/webp"}],"author":"Bocon Technical Team","twitter_card":"summary_large_image","twitter_creator":"@BoconAnd","twitter_site":"@BoconAnd","twitter_misc":{"Written by":"Bocon Technical Team","Est. reading time":"4 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/zjbocon.com\/?p=2471#article","isPartOf":{"@id":"https:\/\/zjbocon.com\/?p=2471"},"author":{"name":"Bocon Technical Team","@id":"https:\/\/zjbocon.com\/#\/schema\/person\/f12be028b8ae9843a4396dcc8012b425"},"headline":"Safety Requirements for Using Ethylene Oxide in sterilization","datePublished":"2024-12-23T01:49:40+00:00","dateModified":"2025-10-01T11:14:06+00:00","mainEntityOfPage":{"@id":"https:\/\/zjbocon.com\/?p=2471"},"wordCount":619,"commentCount":0,"publisher":{"@id":"https:\/\/zjbocon.com\/#organization"},"image":{"@id":"https:\/\/zjbocon.com\/?p=2471#primaryimage"},"thumbnailUrl":"https:\/\/zjbocon.com\/wp-content\/uploads\/2024\/10\/Electrical-Scale.webp","articleSection":["Company News","ETO STERILIZER"],"inLanguage":"ne-NP","potentialAction":[{"@type":"CommentAction","name":"Comment","target":["https:\/\/zjbocon.com\/?p=2471#respond"]}]},{"@type":"WebPage","@id":"https:\/\/zjbocon.com\/?p=2471","url":"https:\/\/zjbocon.com\/?p=2471","name":"Safety Requirements for Using Ethylene Oxide in sterilization - ETO STERILIZER","isPartOf":{"@id":"https:\/\/zjbocon.com\/#website"},"primaryImageOfPage":{"@id":"https:\/\/zjbocon.com\/?p=2471#primaryimage"},"image":{"@id":"https:\/\/zjbocon.com\/?p=2471#primaryimage"},"thumbnailUrl":"https:\/\/zjbocon.com\/wp-content\/uploads\/2024\/10\/Electrical-Scale.webp","datePublished":"2024-12-23T01:49:40+00:00","dateModified":"2025-10-01T11:14:06+00:00","description":"The ethylene oxide gas(Ethylene Oxide in sterilization) for the sterilizer should be supplied by dedicated ethylene oxide steel cylinders.","breadcrumb":{"@id":"https:\/\/zjbocon.com\/?p=2471#breadcrumb"},"inLanguage":"ne-NP","potentialAction":[{"@type":"ReadAction","target":["https:\/\/zjbocon.com\/?p=2471"]}]},{"@type":"ImageObject","inLanguage":"ne-NP","@id":"https:\/\/zjbocon.com\/?p=2471#primaryimage","url":"https:\/\/zjbocon.com\/wp-content\/uploads\/2024\/10\/Electrical-Scale.webp","contentUrl":"https:\/\/zjbocon.com\/wp-content\/uploads\/2024\/10\/Electrical-Scale.webp","width":255,"height":569,"caption":"eo gas"},{"@type":"BreadcrumbList","@id":"https:\/\/zjbocon.com\/?p=2471#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/zjbocon.com\/"},{"@type":"ListItem","position":2,"name":"Safety Requirements for Using Ethylene Oxide in sterilization"}]},{"@type":"WebSite","@id":"https:\/\/zjbocon.com\/#website","url":"https:\/\/zjbocon.com\/","name":"ETO STERILIZER","description":"One-stop Solution Supplier of Ethylene Oxide Sterilization","publisher":{"@id":"https:\/\/zjbocon.com\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/zjbocon.com\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"ne-NP"},{"@type":"Organization","@id":"https:\/\/zjbocon.com\/#organization","name":"ETO STERILIZER","url":"https:\/\/zjbocon.com\/","logo":{"@type":"ImageObject","inLanguage":"ne-NP","@id":"https:\/\/zjbocon.com\/#\/schema\/logo\/image\/","url":"https:\/\/zjbocon.com\/wp-content\/uploads\/2024\/10\/logo-1.webp","contentUrl":"https:\/\/zjbocon.com\/wp-content\/uploads\/2024\/10\/logo-1.webp","width":180,"height":60,"caption":"ETO STERILIZER"},"image":{"@id":"https:\/\/zjbocon.com\/#\/schema\/logo\/image\/"},"sameAs":["https:\/\/www.facebook.com\/profile.php?id=100088482339878","https:\/\/x.com\/BoconAnd","https:\/\/www.linkedin.com\/in\/--06a221139\/"]},{"@type":"Person","@id":"https:\/\/zjbocon.com\/#\/schema\/person\/f12be028b8ae9843a4396dcc8012b425","name":"Bocon Technical Team","image":{"@type":"ImageObject","inLanguage":"ne-NP","@id":"https:\/\/secure.gravatar.com\/avatar\/d7a825658be227f26b237e519f8541e05aabc9ff27b8eec4544a233a48c53be0?s=96&d=identicon&r=g","url":"https:\/\/secure.gravatar.com\/avatar\/d7a825658be227f26b237e519f8541e05aabc9ff27b8eec4544a233a48c53be0?s=96&d=identicon&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/d7a825658be227f26b237e519f8541e05aabc9ff27b8eec4544a233a48c53be0?s=96&d=identicon&r=g","caption":"Bocon Technical Team"},"sameAs":["https:\/\/zjbocon.com\/","https:\/\/www.facebook.com\/profile.php?id=100088482339878","https:\/\/www.linkedin.com\/in\/\/hayley--968190269\/"],"url":"https:\/\/zjbocon.com\/?author=234312599"}]}},"jetpack_publicize_connections":[],"jetpack_featured_media_url":"https:\/\/zjbocon.com\/wp-content\/uploads\/2024\/10\/Electrical-Scale.webp","uagb_featured_image_src":{"full":["https:\/\/zjbocon.com\/wp-content\/uploads\/2024\/10\/Electrical-Scale.webp",255,569,false],"thumbnail":["https:\/\/zjbocon.com\/wp-content\/uploads\/2024\/10\/Electrical-Scale-150x150.webp",150,150,true],"medium":["https:\/\/zjbocon.com\/wp-content\/uploads\/2024\/10\/Electrical-Scale-134x300.webp",134,300,true],"medium_large":["https:\/\/zjbocon.com\/wp-content\/uploads\/2024\/10\/Electrical-Scale.webp",255,569,false],"large":["https:\/\/zjbocon.com\/wp-content\/uploads\/2024\/10\/Electrical-Scale.webp",255,569,false],"1536x1536":["https:\/\/zjbocon.com\/wp-content\/uploads\/2024\/10\/Electrical-Scale.webp",255,569,false],"2048x2048":["https:\/\/zjbocon.com\/wp-content\/uploads\/2024\/10\/Electrical-Scale.webp",255,569,false],"woocommerce_thumbnail":["https:\/\/zjbocon.com\/wp-content\/uploads\/2024\/10\/Electrical-Scale.webp",255,569,false],"woocommerce_single":["https:\/\/zjbocon.com\/wp-content\/uploads\/2024\/10\/Electrical-Scale.webp",255,569,false],"woocommerce_gallery_thumbnail":["https:\/\/zjbocon.com\/wp-content\/uploads\/2024\/10\/Electrical-Scale-100x100.webp",100,100,true]},"uagb_author_info":{"display_name":"Bocon Technical Team","author_link":"https:\/\/zjbocon.com\/?author=234312599"},"uagb_comment_info":0,"uagb_excerpt":"Note: Regardless of whether the equipment is in normal operation, malfunction, or maintenance state, if personnel need to enter the [&hellip;]","jetpack_likes_enabled":true,"jetpack_sharing_enabled":true,"jetpack_shortlink":"https:\/\/wp.me\/pgZDV6-DR","jetpack-related-posts":[{"id":2476,"url":"https:\/\/zjbocon.com\/?p=2476","url_meta":{"origin":2471,"position":0},"title":"Ethylene Oxide Leak Handling when using eto sterilizer","author":"Bocon Technical Team","date":"2024-12-23","format":false,"excerpt":"If a leak is detected in the eto sterilizer dosing pipeline during the administration process, immediately close the medication bottle, switch and the dosing valve on the main unit. Turn on the axial fan to ensure proper ventilation, and then proceed with repairs.","rel":"","context":"In &quot;Company News&quot;","block_context":{"text":"Company News","link":"https:\/\/zjbocon.com\/?cat=133125"},"img":{"alt_text":"","src":"https:\/\/i0.wp.com\/zjbocon.com\/wp-content\/uploads\/2025\/09\/ethylene-oxide-sterilization-19-scaled.webp?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/zjbocon.com\/wp-content\/uploads\/2025\/09\/ethylene-oxide-sterilization-19-scaled.webp?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/zjbocon.com\/wp-content\/uploads\/2025\/09\/ethylene-oxide-sterilization-19-scaled.webp?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/zjbocon.com\/wp-content\/uploads\/2025\/09\/ethylene-oxide-sterilization-19-scaled.webp?resize=700%2C400&ssl=1 2x, https:\/\/i0.wp.com\/zjbocon.com\/wp-content\/uploads\/2025\/09\/ethylene-oxide-sterilization-19-scaled.webp?resize=1050%2C600&ssl=1 3x, https:\/\/i0.wp.com\/zjbocon.com\/wp-content\/uploads\/2025\/09\/ethylene-oxide-sterilization-19-scaled.webp?resize=1400%2C800&ssl=1 4x"},"classes":[]},{"id":8958,"url":"https:\/\/zjbocon.com\/?p=8958","url_meta":{"origin":2471,"position":1},"title":"Understanding What is ETO Sterilizers: A Comprehensive Guide","author":"Bocon Technical Team","date":"2025-12-16","format":false,"excerpt":"Discover the essentials of ETO sterilizers and ethylene oxide sterilization, ensuring the highest hygiene standards in healthcare and beyond.","rel":"","context":"In &quot;Company News&quot;","block_context":{"text":"Company News","link":"https:\/\/zjbocon.com\/?cat=133125"},"img":{"alt_text":"","src":"https:\/\/i0.wp.com\/zjbocon.com\/wp-content\/uploads\/2024\/11\/eto-sterilizer-hzbocon-3.png?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/zjbocon.com\/wp-content\/uploads\/2024\/11\/eto-sterilizer-hzbocon-3.png?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/zjbocon.com\/wp-content\/uploads\/2024\/11\/eto-sterilizer-hzbocon-3.png?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/zjbocon.com\/wp-content\/uploads\/2024\/11\/eto-sterilizer-hzbocon-3.png?resize=700%2C400&ssl=1 2x, https:\/\/i0.wp.com\/zjbocon.com\/wp-content\/uploads\/2024\/11\/eto-sterilizer-hzbocon-3.png?resize=1050%2C600&ssl=1 3x"},"classes":[]},{"id":3093,"url":"https:\/\/zjbocon.com\/?p=3093","url_meta":{"origin":2471,"position":2},"title":"Introduction to Ethylene Oxide Sterilizers","author":"Bocon Technical Team","date":"2025-02-05","format":false,"excerpt":"Discover how ethylene oxide sterilizers work, their applications, benefits, and safety considerations. Learn why they are essential for medical and industrial sterilization.","rel":"","context":"In &quot;Company News&quot;","block_context":{"text":"Company News","link":"https:\/\/zjbocon.com\/?cat=133125"},"img":{"alt_text":"","src":"https:\/\/i0.wp.com\/zjbocon.com\/wp-content\/uploads\/2024\/11\/ethylene-oxide-sterilization-21.webp?resize=350%2C200","width":350,"height":200},"classes":[]},{"id":2453,"url":"https:\/\/zjbocon.com\/?p=2453","url_meta":{"origin":2471,"position":3},"title":"Microbial Killing Performance of Ethylene Oxide Sterilizers","author":"Bocon Technical Team","date":"2024-12-20","format":false,"excerpt":"Note 1: The Ethylene Oxide sterilization conditions must be obtained through validation confirmation and should be verified with monitoring and routine control during each sterilization cycle. The requirements for validation and routine control are outlined in GB 18279. Note 2: This testing method is also applicable to A class Ethylene\u2026","rel":"","context":"In &quot;Company News&quot;","block_context":{"text":"Company News","link":"https:\/\/zjbocon.com\/?cat=133125"},"img":{"alt_text":"eto sterilizer","src":"https:\/\/i0.wp.com\/zjbocon.com\/wp-content\/uploads\/2024\/10\/banner__.webp?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/zjbocon.com\/wp-content\/uploads\/2024\/10\/banner__.webp?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/zjbocon.com\/wp-content\/uploads\/2024\/10\/banner__.webp?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/zjbocon.com\/wp-content\/uploads\/2024\/10\/banner__.webp?resize=700%2C400&ssl=1 2x"},"classes":[]},{"id":2448,"url":"https:\/\/zjbocon.com\/?p=2448","url_meta":{"origin":2471,"position":4},"title":"eto sterilization Chamber Temperature Distribution Testing","author":"Bocon Technical Team","date":"2024-12-20","format":false,"excerpt":"The temperature of representative areas on the inner surfaces should be measured and recorded using temperature recording instruments that comply with the requirements of Appendix B.","rel":"","context":"In &quot;Company News&quot;","block_context":{"text":"Company News","link":"https:\/\/zjbocon.com\/?cat=133125"},"img":{"alt_text":"","src":"https:\/\/i0.wp.com\/zjbocon.com\/wp-content\/uploads\/2025\/09\/ethylene-oxide-sterilization-54.webp?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/zjbocon.com\/wp-content\/uploads\/2025\/09\/ethylene-oxide-sterilization-54.webp?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/zjbocon.com\/wp-content\/uploads\/2025\/09\/ethylene-oxide-sterilization-54.webp?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/zjbocon.com\/wp-content\/uploads\/2025\/09\/ethylene-oxide-sterilization-54.webp?resize=700%2C400&ssl=1 2x, https:\/\/i0.wp.com\/zjbocon.com\/wp-content\/uploads\/2025\/09\/ethylene-oxide-sterilization-54.webp?resize=1050%2C600&ssl=1 3x"},"classes":[]},{"id":2439,"url":"https:\/\/zjbocon.com\/?p=2439","url_meta":{"origin":2471,"position":5},"title":"Preparatory Work Before eto Sterilization","author":"Bocon Technical Team","date":"2024-12-17","format":false,"excerpt":"Appearance Inspection: Check the main unit, control rack, and electrical control cabinet for any damage on the surface.","rel":"","context":"In &quot;Company News&quot;","block_context":{"text":"Company News","link":"https:\/\/zjbocon.com\/?cat=133125"},"img":{"alt_text":"","src":"https:\/\/i0.wp.com\/zjbocon.com\/wp-content\/uploads\/2025\/09\/sterilizer-station-design-2.webp?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/zjbocon.com\/wp-content\/uploads\/2025\/09\/sterilizer-station-design-2.webp?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/zjbocon.com\/wp-content\/uploads\/2025\/09\/sterilizer-station-design-2.webp?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/zjbocon.com\/wp-content\/uploads\/2025\/09\/sterilizer-station-design-2.webp?resize=700%2C400&ssl=1 2x"},"classes":[]}],"_links":{"self":[{"href":"https:\/\/zjbocon.com\/index.php?rest_route=\/wp\/v2\/posts\/2471","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/zjbocon.com\/index.php?rest_route=\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/zjbocon.com\/index.php?rest_route=\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/zjbocon.com\/index.php?rest_route=\/wp\/v2\/users\/234312599"}],"replies":[{"embeddable":true,"href":"https:\/\/zjbocon.com\/index.php?rest_route=%2Fwp%2Fv2%2Fcomments&post=2471"}],"version-history":[{"count":5,"href":"https:\/\/zjbocon.com\/index.php?rest_route=\/wp\/v2\/posts\/2471\/revisions"}],"predecessor-version":[{"id":2499,"href":"https:\/\/zjbocon.com\/index.php?rest_route=\/wp\/v2\/posts\/2471\/revisions\/2499"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/zjbocon.com\/index.php?rest_route=\/wp\/v2\/media\/1686"}],"wp:attachment":[{"href":"https:\/\/zjbocon.com\/index.php?rest_route=%2Fwp%2Fv2%2Fmedia&parent=2471"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/zjbocon.com\/index.php?rest_route=%2Fwp%2Fv2%2Fcategories&post=2471"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/zjbocon.com\/index.php?rest_route=%2Fwp%2Fv2%2Ftags&post=2471"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}