{"id":2018,"date":"2024-10-28T11:23:57","date_gmt":"2024-10-28T03:23:57","guid":{"rendered":"https:\/\/zjbocon.com\/?p=2018"},"modified":"2024-11-06T14:09:44","modified_gmt":"2024-11-06T06:09:44","slug":"eto-sterilizer-system","status":"publish","type":"post","link":"https:\/\/zjbocon.com\/?p=2018","title":{"rendered":"Protection function OF eTO chamber SYSTEM"},"content":{"rendered":"\n<p class=\"wp-block-paragraph\"> <\/p>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"h-protection-mechanism-and-explanation-of-eto-sterilizer-system\">Mecanismul de protecție și explicația Sistemului de sterilizare ETO<\/h2>\n\n\n\n<div class=\"wp-block-uagb-image uagb-block-dba6a8eb wp-block-uagb-image--layout-default wp-block-uagb-image--effect-static wp-block-uagb-image--align-none\"><figure class=\"wp-block-uagb-image__figure\"><a class=\"\" href=\"https:\/\/zjbocon.com\/product\/sterilizer-control-system\/\" target=\"\" rel=\"noopener\"><img loading=\"lazy\" decoding=\"async\" src=\"https:\/\/zjbocon.com\/wp-content\/uploads\/2024\/10\/Ethylene-Oxide-Sterilizer-Control-System-5.webp\" alt=\"Ethylene Oxide Sterilizer Control System (5)\" class=\"uag-image-1277\" width=\"616\" height=\"786\" title=\"Ethylene role =\"img\" \><\/a><\/figure><\/div>\n\n\n\n<ol class=\"wp-block-list\">\n<li>Sistemul de sterilizare ETO are șase niveluri diferite de permisiuni de funcționare. Personalul cu permisiuni diferite poate opera conținuturi diferite pentru a preveni confuzia în funcționare sau defecțiunea echipamentului sau accidentul de siguranță cauzat de operarea de către personal fără pregătire profesională<\/li>\n<\/ol>\n\n\n\n<p class=\"wp-block-paragraph\">2. În mod implicit, sistemul va efectua testul de detectare a scurgerilor înainte de dozarea fiecărui lot. Dacă testul de detectare a scurgerilor eșuează, sistemul va opri automat ciclul și nu va mai continua, iar alarma va solicita<\/p>\n\n\n\n<div class=\"wp-block-uagb-image uagb-block-1cf2e572 wp-block-uagb-image--layout-default wp-block-uagb-image--effect-static wp-block-uagb-image--align-none\"><figure class=\"wp-block-uagb-image__figure\"><img loading=\"lazy\" decoding=\"async\" src=\"https:\/\/zjbocon.com\/wp-content\/uploads\/2024\/10\/4.-leak-testing.webp\" alt=\"\" class=\"uag-image-1015\" width=\"719\" height=\"544\" title=\"4. leak testing\" role=\"img\" \><\/figure><\/div>\n\n\n\n<p class=\"wp-block-paragraph\">3. Dacă corpul dulapului are scurgeri în timpul etapei de expunere a echipamentului, sistemul de cameră ETO va trece automat la etapa de curățare pentru a se asigura că EO nu se va scurge în atelier și nu va provoca accidente de siguranță.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">4. Când echipamentul este în funcțiune, dacă dorește să oprească ciclul la jumătate, sistemul va trece automat la un proces de procesare sigur în funcție de diferite condiții de operare. De exemplu, după dozare, sistemul are nevoie de curățare forțată pentru a reseta întregul proces.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">5. Dacă sistemul este echipat cu un cântar electronic, atâta timp cât echipamentul este pornit, puteți verifica dacă greutatea cilindrului EO se modifică în mod anormal în orice moment, pentru a notifica în timp util personalul de întreținere a echipamentului cu privire la potențiale pericole de siguranță<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">6. Sistemul de cameră ETO are funcția de detectare și protecție a presiunii ultra-înalte. Dacă sistemul detectează că presiunea din dulap este mai mare decât presiunea maximă admisă, indiferent dacă echipamentul este în funcțiune sau nu, pompa de vid trebuie să fie forțată să pornească pentru a reduce presiunea din dulap pentru a preveni scurgerea gazului din dulap în atelier, sau dulapul va fi deteriorat de presiunea ridicată din dulap.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">7. De fiecare dată când ușa este deschisă, sistemul de cameră ETO va verifica dacă presiunea din dulap se află în intervalul de siguranță și dacă starea de funcționare din dulap este în stare de siguranță, altfel ușa va fi blocată și nu poate fi deschisă<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">8.Pentru a asigura siguranța personală, echipamentul poate fi echipat cu un sistem de evacuare inofensiv. După ce ușa dulapului este deschisă, asigurați-vă că aerul din atelier poate intra doar în dulap, dar nu poate fi evacuat din dulap în mediul atelierului<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">9.Dacă echipamentul a fost curățat, dar ușa nu a fost deschisă, sistemul va verifica automat timpul de descărcare. Dacă expirarea timpului de descărcare este mai mare de 30 de minute, ușa va fi blocată și nu poate fi deschisă, iar procesul de curățare trebuie executat din nou. Această funcție este utilizată pentru a se asigura că EO din produs nu va fi eliberat lent în mediul atelierului, cauzând poluarea mediului în atelier și daune pentru sănătatea personală.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">10. Întregul sistem de control are funcție de auto-diagnosticare pentru toate tipurile de echipamente și senzori, care este utilizat pentru a preveni funcționarea anormală a echipamentului în caz de defecțiune a senzorului și, în același timp, indică personalului de întreținere ce senzor sau echipament a eșuat, astfel încât personalul de întreținere să poată găsi și rezolva rapid problemele<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">11.SISTEMUL de sterilizator ETO are peste 100 de informații despre erori și alarme, ceea ce permite operatorilor și personalului de întreținere să cunoască funcționarea echipamentului în timp util și precis, astfel încât personalul de întreținere să poată găsi și rezolva rapid problemele<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">12.După descărcarea parametrilor de proces, dacă există parametri nerezonabili, va apărea o solicitare de eșec de descărcare pentru a preveni funcționarea întregului lot să eșueze atunci când parametrii sunt nerezonabili<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">13.După descărcarea parametrilor de proces, dacă există parametri nerezonabili, va apărea o solicitare de eșec de descărcare pentru a preveni funcționarea întregului lot să eșueze atunci când parametrii sunt nerezonabili<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">14. În cazul pierderii sursei de alimentare externă, UPS-ul va continua să furnizeze energie sistemului, iar echipamentul se va ocupa de starea suspendată pentru a se asigura că echipamentul nu se va scurge după o întrerupere a alimentării și a asigura un timp tampon de siguranță de cel puțin 15 minute. După ce echipamentul este oprit prin procesul normal de funcționare, echipamentul poate continua să funcționeze atunci când alimentarea externă este restabilită<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">15. Când IPC eșuează în timpul funcționării sistemului, IPC poate fi repornit direct, iar software-ul poate conecta automat înregistrarea originală<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">16. Sistemul are o funcție detaliată de urmărire a auditului, care poate înregistra aproape toate acțiunile de operare pentru comoditatea analizei accidentelor și a prevenirii defecțiunilor în etapa ulterioară<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"h-contact\">Contact<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Telefon:<a href=\"https:\/\/wa.me\/8619975258603\">+8619975258603<\/a><\/p>\n\n\n\n<p class=\"wp-block-paragraph\">E-mail:<a href=\"mailto:hayley@hzbocon.com\">hayley@hzbocon.com<\/a><\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Site local: Camera 1202, Caitong Zhongxin, districtul Xiasha, orașul Hangzhou, provincia Zhejiang, China<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Site:<a href=\"https:\/\/www.hzbocon.com\/\">hzbocon.com<\/a><a href=\"https:\/\/zjbocon.com\/\">zjbocon.com<\/a><\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><\/p>\n","protected":false},"excerpt":{"rendered":"<p>Protection mechanism and explanation OF ETO Sterilizer System 2. By default, the system will perform the leak detection test before [&hellip;]<\/p>\n","protected":false},"author":234312599,"featured_media":1889,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_uag_custom_page_level_css":"","site-sidebar-layout":"default","site-content-layout":"","ast-site-content-layout":"default","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","ast-disable-related-posts":"","theme-transparent-header-meta":"","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"set","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"_jetpack_newsletter_access":"","_jetpack_dont_email_post_to_subs":false,"_jetpack_newsletter_tier_id":0,"_jetpack_memberships_contains_paywalled_content":false,"_jetpack_feature_clip_id":0,"_jetpack_memberships_contains_paid_content":false,"footnotes":"","jetpack_publicize_message":"","jetpack_publicize_feature_enabled":true,"jetpack_social_post_already_shared":false,"jetpack_social_options":{"image_generator_settings":{"template":"highway","enabled":false},"version":2},"jetpack_post_was_ever_published":false},"categories":[133124],"tags":[],"class_list":["post-2018","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-eto-sterilizer"],"yoast_head":"<!-- This site is optimized with the Yoast SEO Premium plugin v27.2 (Yoast SEO v28.0) - https:\/\/yoast.com\/product\/yoast-seo-premium-wordpress\/ -->\n<title>Funcția de protecție a SISTEMULUI de cameră eTO - STERILIZATOR ETO<\/title>\n<meta name=\"description\" content=\"ETO chamber System (The ETO sterilizer system )has six different levels of operation permissions. Personnel with permissions\" \>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \>\n<link rel=\"canonical\" href=\"https:\/\/zjbocon.com\/?p=2018\" \>\n<meta property=\"og:locale\" content=\"ro_RO\" \>\n<meta property=\"og:type\" content=\"article\" \>\n<meta property=\"og:title\" content=\"Protection function OF eTO chamber SYSTEM\" \>\n<meta property=\"og:description\" content=\"ETO chamber System (The ETO sterilizer system )has six different levels of operation permissions. Personnel with permissions\" \>\n<meta property=\"og:url\" content=\"https:\/\/zjbocon.com\/?p=2018\" \>\n<meta property=\"og:site_name\" content=\"ETO STERILIZER\" \>\n<meta property=\"article:publisher\" content=\"https:\/\/www.facebook.com\/profile.php?id=100088482339878\" \>\n<meta property=\"article:author\" content=\"https:\/\/www.facebook.com\/profile.php?id=100088482339878\" \>\n<meta property=\"article:published_time\" content=\"2024-10-28T03:23:57+00:00\" \>\n<meta property=\"article:modified_time\" content=\"2024-11-06T06:09:44+00:00\" \>\n<meta property=\"og:image\" content=\"https:\/\/zjbocon.com\/wp-content\/uploads\/2024\/10\/customer_5.webp\" \>\n\t<meta property=\"og:image:width\" content=\"300\" \>\n\t<meta property=\"og:image:height\" content=\"200\" \>\n\t<meta property=\"og:image:type\" content=\"image\/webp\" \>\n<meta name=\"author\" content=\"Bocon Technical Team\" \>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \>\n<meta name=\"twitter:creator\" content=\"@BoconAnd\" \>\n<meta name=\"twitter:site\" content=\"@BoconAnd\" \>\n<meta name=\"twitter:label1\" content=\"Written by\" \>\n\t<meta name=\"twitter:data1\" content=\"Bocon Technical Team\" \>\n\t<meta name=\"twitter:label2\" content=\"Est. reading time\" \>\n\t<meta name=\"twitter:data2\" content=\"4 minutes\" \>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\\\/\\\/zjbocon.com\\\/?p=2018#article\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/zjbocon.com\\\/?p=2018\"},\"author\":{\"name\":\"Bocon Technical Team\",\"@id\":\"https:\\\/\\\/zjbocon.com\\\/#\\\/schema\\\/person\\\/f12be028b8ae9843a4396dcc8012b425\"},\"headline\":\"Protection function OF eTO chamber SYSTEM\",\"datePublished\":\"2024-10-28T03:23:57+00:00\",\"dateModified\":\"2024-11-06T06:09:44+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/zjbocon.com\\\/?p=2018\"},\"wordCount\":765,\"commentCount\":0,\"publisher\":{\"@id\":\"https:\\\/\\\/zjbocon.com\\\/#organization\"},\"image\":{\"@id\":\"https:\\\/\\\/zjbocon.com\\\/?p=2018#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/zjbocon.com\\\/wp-content\\\/uploads\\\/2024\\\/10\\\/customer_5.webp\",\"articleSection\":[\"ETO STERILIZER\"],\"inLanguage\":\"ro-RO\",\"potentialAction\":[{\"@type\":\"CommentAction\",\"name\":\"Comment\",\"target\":[\"https:\\\/\\\/zjbocon.com\\\/?p=2018#respond\"]}]},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/zjbocon.com\\\/?p=2018\",\"url\":\"https:\\\/\\\/zjbocon.com\\\/?p=2018\",\"name\":\"Protection function OF eTO chamber SYSTEM - ETO STERILIZER\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/zjbocon.com\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/zjbocon.com\\\/?p=2018#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/zjbocon.com\\\/?p=2018#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/zjbocon.com\\\/wp-content\\\/uploads\\\/2024\\\/10\\\/customer_5.webp\",\"datePublished\":\"2024-10-28T03:23:57+00:00\",\"dateModified\":\"2024-11-06T06:09:44+00:00\",\"description\":\"ETO chamber System (The ETO sterilizer system )has six different levels of operation permissions. Personnel with different permissions\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/zjbocon.com\\\/?p=2018#breadcrumb\"},\"inLanguage\":\"ro-RO\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/zjbocon.com\\\/?p=2018\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"ro-RO\",\"@id\":\"https:\\\/\\\/zjbocon.com\\\/?p=2018#primaryimage\",\"url\":\"https:\\\/\\\/zjbocon.com\\\/wp-content\\\/uploads\\\/2024\\\/10\\\/customer_5.webp\",\"contentUrl\":\"https:\\\/\\\/zjbocon.com\\\/wp-content\\\/uploads\\\/2024\\\/10\\\/customer_5.webp\",\"width\":300,\"height\":200},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/zjbocon.com\\\/?p=2018#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/zjbocon.com\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Protection function OF eTO chamber SYSTEM\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/zjbocon.com\\\/#website\",\"url\":\"https:\\\/\\\/zjbocon.com\\\/\",\"name\":\"ETO STERILIZER\",\"description\":\"One-stop Solution Supplier of Ethylene Oxide Sterilization\",\"publisher\":{\"@id\":\"https:\\\/\\\/zjbocon.com\\\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/zjbocon.com\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"ro-RO\"},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/zjbocon.com\\\/#organization\",\"name\":\"ETO STERILIZER\",\"url\":\"https:\\\/\\\/zjbocon.com\\\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"ro-RO\",\"@id\":\"https:\\\/\\\/zjbocon.com\\\/#\\\/schema\\\/logo\\\/image\\\/\",\"url\":\"https:\\\/\\\/zjbocon.com\\\/wp-content\\\/uploads\\\/2024\\\/10\\\/logo-1.webp\",\"contentUrl\":\"https:\\\/\\\/zjbocon.com\\\/wp-content\\\/uploads\\\/2024\\\/10\\\/logo-1.webp\",\"width\":180,\"height\":60,\"caption\":\"ETO STERILIZER\"},\"image\":{\"@id\":\"https:\\\/\\\/zjbocon.com\\\/#\\\/schema\\\/logo\\\/image\\\/\"},\"sameAs\":[\"https:\\\/\\\/www.facebook.com\\\/profile.php?id=100088482339878\",\"https:\\\/\\\/x.com\\\/BoconAnd\",\"https:\\\/\\\/www.linkedin.com\\\/in\\\/--06a221139\\\/\"]},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/zjbocon.com\\\/#\\\/schema\\\/person\\\/f12be028b8ae9843a4396dcc8012b425\",\"name\":\"Bocon Technical Team\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"ro-RO\",\"@id\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/d7a825658be227f26b237e519f8541e05aabc9ff27b8eec4544a233a48c53be0?s=96&d=identicon&r=g\",\"url\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/d7a825658be227f26b237e519f8541e05aabc9ff27b8eec4544a233a48c53be0?s=96&d=identicon&r=g\",\"contentUrl\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/d7a825658be227f26b237e519f8541e05aabc9ff27b8eec4544a233a48c53be0?s=96&d=identicon&r=g\",\"caption\":\"Bocon Technical Team\"},\"sameAs\":[\"https:\\\/\\\/zjbocon.com\\\/\",\"https:\\\/\\\/www.facebook.com\\\/profile.php?id=100088482339878\",\"https:\\\/\\\/www.linkedin.com\\\/in\\\/\\\/hayley--968190269\\\/\"],\"url\":\"https:\\\/\\\/zjbocon.com\\\/?author=234312599\"}]}<\/script>\n<!-- \/ Yoast SEO Premium plugin. -->","yoast_head_json":{"title":"Protection function OF eTO chamber SYSTEM - ETO STERILIZER","description":"ETO chamber System (The ETO sterilizer system )has six different levels of operation permissions. Personnel with different permissions","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/zjbocon.com\/?p=2018","og_locale":"ro_RO","og_type":"article","og_title":"Protection function OF eTO chamber SYSTEM","og_description":"ETO chamber System (The ETO sterilizer system )has six different levels of operation permissions. Personnel with different permissions","og_url":"https:\/\/zjbocon.com\/?p=2018","og_site_name":"ETO STERILIZER","article_publisher":"https:\/\/www.facebook.com\/profile.php?id=100088482339878","article_author":"https:\/\/www.facebook.com\/profile.php?id=100088482339878","article_published_time":"2024-10-28T03:23:57+00:00","article_modified_time":"2024-11-06T06:09:44+00:00","og_image":[{"width":300,"height":200,"url":"https:\/\/zjbocon.com\/wp-content\/uploads\/2024\/10\/customer_5.webp","type":"image\/webp"}],"author":"Bocon Technical Team","twitter_card":"summary_large_image","twitter_creator":"@BoconAnd","twitter_site":"@BoconAnd","twitter_misc":{"Written by":"Bocon Technical Team","Est. reading time":"4 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/zjbocon.com\/?p=2018#article","isPartOf":{"@id":"https:\/\/zjbocon.com\/?p=2018"},"author":{"name":"Bocon Technical Team","@id":"https:\/\/zjbocon.com\/#\/schema\/person\/f12be028b8ae9843a4396dcc8012b425"},"headline":"Protection function OF eTO chamber SYSTEM","datePublished":"2024-10-28T03:23:57+00:00","dateModified":"2024-11-06T06:09:44+00:00","mainEntityOfPage":{"@id":"https:\/\/zjbocon.com\/?p=2018"},"wordCount":765,"commentCount":0,"publisher":{"@id":"https:\/\/zjbocon.com\/#organization"},"image":{"@id":"https:\/\/zjbocon.com\/?p=2018#primaryimage"},"thumbnailUrl":"https:\/\/zjbocon.com\/wp-content\/uploads\/2024\/10\/customer_5.webp","articleSection":["ETO STERILIZER"],"inLanguage":"ro-RO","potentialAction":[{"@type":"CommentAction","name":"Comment","target":["https:\/\/zjbocon.com\/?p=2018#respond"]}]},{"@type":"WebPage","@id":"https:\/\/zjbocon.com\/?p=2018","url":"https:\/\/zjbocon.com\/?p=2018","name":"Protection function OF eTO chamber SYSTEM - ETO STERILIZER","isPartOf":{"@id":"https:\/\/zjbocon.com\/#website"},"primaryImageOfPage":{"@id":"https:\/\/zjbocon.com\/?p=2018#primaryimage"},"image":{"@id":"https:\/\/zjbocon.com\/?p=2018#primaryimage"},"thumbnailUrl":"https:\/\/zjbocon.com\/wp-content\/uploads\/2024\/10\/customer_5.webp","datePublished":"2024-10-28T03:23:57+00:00","dateModified":"2024-11-06T06:09:44+00:00","description":"ETO chamber System (The ETO sterilizer system )has six different levels of operation permissions. Personnel with different permissions","breadcrumb":{"@id":"https:\/\/zjbocon.com\/?p=2018#breadcrumb"},"inLanguage":"ro-RO","potentialAction":[{"@type":"ReadAction","target":["https:\/\/zjbocon.com\/?p=2018"]}]},{"@type":"ImageObject","inLanguage":"ro-RO","@id":"https:\/\/zjbocon.com\/?p=2018#primaryimage","url":"https:\/\/zjbocon.com\/wp-content\/uploads\/2024\/10\/customer_5.webp","contentUrl":"https:\/\/zjbocon.com\/wp-content\/uploads\/2024\/10\/customer_5.webp","width":300,"height":200},{"@type":"BreadcrumbList","@id":"https:\/\/zjbocon.com\/?p=2018#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/zjbocon.com\/"},{"@type":"ListItem","position":2,"name":"Protection function OF eTO chamber SYSTEM"}]},{"@type":"WebSite","@id":"https:\/\/zjbocon.com\/#website","url":"https:\/\/zjbocon.com\/","name":"ETO STERILIZER","description":"One-stop Solution Supplier of Ethylene Oxide Sterilization","publisher":{"@id":"https:\/\/zjbocon.com\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/zjbocon.com\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"ro-RO"},{"@type":"Organization","@id":"https:\/\/zjbocon.com\/#organization","name":"ETO STERILIZER","url":"https:\/\/zjbocon.com\/","logo":{"@type":"ImageObject","inLanguage":"ro-RO","@id":"https:\/\/zjbocon.com\/#\/schema\/logo\/image\/","url":"https:\/\/zjbocon.com\/wp-content\/uploads\/2024\/10\/logo-1.webp","contentUrl":"https:\/\/zjbocon.com\/wp-content\/uploads\/2024\/10\/logo-1.webp","width":180,"height":60,"caption":"ETO STERILIZER"},"image":{"@id":"https:\/\/zjbocon.com\/#\/schema\/logo\/image\/"},"sameAs":["https:\/\/www.facebook.com\/profile.php?id=100088482339878","https:\/\/x.com\/BoconAnd","https:\/\/www.linkedin.com\/in\/--06a221139\/"]},{"@type":"Person","@id":"https:\/\/zjbocon.com\/#\/schema\/person\/f12be028b8ae9843a4396dcc8012b425","name":"Bocon Technical Team","image":{"@type":"ImageObject","inLanguage":"ro-RO","@id":"https:\/\/secure.gravatar.com\/avatar\/d7a825658be227f26b237e519f8541e05aabc9ff27b8eec4544a233a48c53be0?s=96&d=identicon&r=g","url":"https:\/\/secure.gravatar.com\/avatar\/d7a825658be227f26b237e519f8541e05aabc9ff27b8eec4544a233a48c53be0?s=96&d=identicon&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/d7a825658be227f26b237e519f8541e05aabc9ff27b8eec4544a233a48c53be0?s=96&d=identicon&r=g","caption":"Bocon Technical Team"},"sameAs":["https:\/\/zjbocon.com\/","https:\/\/www.facebook.com\/profile.php?id=100088482339878","https:\/\/www.linkedin.com\/in\/\/hayley--968190269\/"],"url":"https:\/\/zjbocon.com\/?author=234312599"}]}},"jetpack_publicize_connections":[],"jetpack_featured_media_url":"https:\/\/zjbocon.com\/wp-content\/uploads\/2024\/10\/customer_5.webp","uagb_featured_image_src":{"full":["https:\/\/zjbocon.com\/wp-content\/uploads\/2024\/10\/customer_5.webp",300,200,false],"thumbnail":["https:\/\/zjbocon.com\/wp-content\/uploads\/2024\/10\/customer_5-150x150.webp",150,150,true],"medium":["https:\/\/zjbocon.com\/wp-content\/uploads\/2024\/10\/customer_5.webp",300,200,false],"medium_large":["https:\/\/zjbocon.com\/wp-content\/uploads\/2024\/10\/customer_5.webp",300,200,false],"large":["https:\/\/zjbocon.com\/wp-content\/uploads\/2024\/10\/customer_5.webp",300,200,false],"1536x1536":["https:\/\/zjbocon.com\/wp-content\/uploads\/2024\/10\/customer_5.webp",300,200,false],"2048x2048":["https:\/\/zjbocon.com\/wp-content\/uploads\/2024\/10\/customer_5.webp",300,200,false],"woocommerce_thumbnail":["https:\/\/zjbocon.com\/wp-content\/uploads\/2024\/10\/customer_5.webp",300,200,false],"woocommerce_single":["https:\/\/zjbocon.com\/wp-content\/uploads\/2024\/10\/customer_5.webp",300,200,false],"woocommerce_gallery_thumbnail":["https:\/\/zjbocon.com\/wp-content\/uploads\/2024\/10\/customer_5-100x100.webp",100,100,true]},"uagb_author_info":{"display_name":"Bocon Technical Team","author_link":"https:\/\/zjbocon.com\/?author=234312599"},"uagb_comment_info":23,"uagb_excerpt":"Protection mechanism and explanation OF ETO Sterilizer System 2. By default, the system will perform the leak detection test before [&hellip;]","jetpack_likes_enabled":true,"jetpack_sharing_enabled":true,"jetpack_shortlink":"https:\/\/wp.me\/pgZDV6-wy","jetpack-related-posts":[{"id":2492,"url":"https:\/\/zjbocon.com\/?p=2492","url_meta":{"origin":2018,"position":0},"title":"Understanding ETO Sterilizer Performance: Keys to Efficiency","author":"Bocon Technical Team","date":"2024-12-24","format":false,"excerpt":"3.4.1 eto sterilizer machine Temperature Setting Range The temperature setting range for the eto sterilizer is: 30 to 70\u00b0C","rel":"","context":"In &quot;Company News&quot;","block_context":{"text":"Company News","link":"https:\/\/zjbocon.com\/?cat=133125"},"img":{"alt_text":"","src":"https:\/\/i0.wp.com\/zjbocon.com\/wp-content\/uploads\/2025\/09\/eto-sterilizer-1.webp?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/zjbocon.com\/wp-content\/uploads\/2025\/09\/eto-sterilizer-1.webp?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/zjbocon.com\/wp-content\/uploads\/2025\/09\/eto-sterilizer-1.webp?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/zjbocon.com\/wp-content\/uploads\/2025\/09\/eto-sterilizer-1.webp?resize=700%2C400&ssl=1 2x, https:\/\/i0.wp.com\/zjbocon.com\/wp-content\/uploads\/2025\/09\/eto-sterilizer-1.webp?resize=1050%2C600&ssl=1 3x"},"classes":[]},{"id":9255,"url":"https:\/\/zjbocon.com\/?p=9255","url_meta":{"origin":2018,"position":1},"title":"Featured System: The Bocon ETO Sterilizer Series","author":"Bocon Technical Team","date":"2026-02-06","format":false,"excerpt":"PHASE 01 PHASE 02 PHASE 03 PHASE 04 PHASE 05 Industrial Grade ETO Sterilization Solutions Explore Bocon ETO Sterilizer Details ? Why Leading Manufacturers Integrate Bocon Systems: Looking to upgrade your sterilization capacity? Explore the Technical Specifications of the Bocon ETO Sterilizer Series ? Headline: From Logistics to Operational Readiness:\u2026","rel":"","context":"In &quot;ETO STERILIZER&quot;","block_context":{"text":"ETO STERILIZER","link":"https:\/\/zjbocon.com\/?cat=133124"},"img":{"alt_text":"","src":"https:\/\/i0.wp.com\/zjbocon.com\/wp-content\/uploads\/2026\/02\/Featured-System-The-Bocon-ETO-Sterilizer-Series-1.webp?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/zjbocon.com\/wp-content\/uploads\/2026\/02\/Featured-System-The-Bocon-ETO-Sterilizer-Series-1.webp?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/zjbocon.com\/wp-content\/uploads\/2026\/02\/Featured-System-The-Bocon-ETO-Sterilizer-Series-1.webp?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/zjbocon.com\/wp-content\/uploads\/2026\/02\/Featured-System-The-Bocon-ETO-Sterilizer-Series-1.webp?resize=700%2C400&ssl=1 2x, https:\/\/i0.wp.com\/zjbocon.com\/wp-content\/uploads\/2026\/02\/Featured-System-The-Bocon-ETO-Sterilizer-Series-1.webp?resize=1050%2C600&ssl=1 3x, https:\/\/i0.wp.com\/zjbocon.com\/wp-content\/uploads\/2026\/02\/Featured-System-The-Bocon-ETO-Sterilizer-Series-1.webp?resize=1400%2C800&ssl=1 4x"},"classes":[]},{"id":2064,"url":"https:\/\/zjbocon.com\/?p=2064","url_meta":{"origin":2018,"position":2},"title":"OQ IN ETO STERILIZATION MACHINE","author":"Bocon Technical Team","date":"2024-10-31","format":false,"excerpt":"In OQ, the performance of the relevant auxiliary system should be determined and the software system should be tested by simulating the fault conditions.","rel":"","context":"In &quot;ETO STERILIZER&quot;","block_context":{"text":"ETO STERILIZER","link":"https:\/\/zjbocon.com\/?cat=133124"},"img":{"alt_text":"","src":"https:\/\/i0.wp.com\/zjbocon.com\/wp-content\/uploads\/2025\/09\/Ethylene-Oxide-Sterilizer-Installation-Guide-1-scaled.webp?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/zjbocon.com\/wp-content\/uploads\/2025\/09\/Ethylene-Oxide-Sterilizer-Installation-Guide-1-scaled.webp?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/zjbocon.com\/wp-content\/uploads\/2025\/09\/Ethylene-Oxide-Sterilizer-Installation-Guide-1-scaled.webp?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/zjbocon.com\/wp-content\/uploads\/2025\/09\/Ethylene-Oxide-Sterilizer-Installation-Guide-1-scaled.webp?resize=700%2C400&ssl=1 2x, https:\/\/i0.wp.com\/zjbocon.com\/wp-content\/uploads\/2025\/09\/Ethylene-Oxide-Sterilizer-Installation-Guide-1-scaled.webp?resize=1050%2C600&ssl=1 3x, https:\/\/i0.wp.com\/zjbocon.com\/wp-content\/uploads\/2025\/09\/Ethylene-Oxide-Sterilizer-Installation-Guide-1-scaled.webp?resize=1400%2C800&ssl=1 4x"},"classes":[]},{"id":2094,"url":"https:\/\/zjbocon.com\/?p=2094","url_meta":{"origin":2018,"position":3},"title":"ETO Sterilizer Manufacturer-HZBOCON","author":"Bocon Technical Team","date":"2024-11-04","format":false,"excerpt":"Hangzhou Bocon Mechanical and Electrical Equipment Co., Ltd., commonly referred to as HZBOCON, stands out as a dedicated Ethylene Oxide (EO\/ETO) sterilizer manufacturer. Established in 2006, HZBOCON has committed itself to the design, development, and manufacturing of EO sterilization equipment, catering to a wide array of industries that require effective\u2026","rel":"","context":"In &quot;ETO STERILIZER&quot;","block_context":{"text":"ETO STERILIZER","link":"https:\/\/zjbocon.com\/?cat=133124"},"img":{"alt_text":"","src":"https:\/\/i0.wp.com\/zjbocon.com\/wp-content\/uploads\/2024\/11\/eto-sterilizer-hzbocon-4.png?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/zjbocon.com\/wp-content\/uploads\/2024\/11\/eto-sterilizer-hzbocon-4.png?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/zjbocon.com\/wp-content\/uploads\/2024\/11\/eto-sterilizer-hzbocon-4.png?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/zjbocon.com\/wp-content\/uploads\/2024\/11\/eto-sterilizer-hzbocon-4.png?resize=700%2C400&ssl=1 2x, https:\/\/i0.wp.com\/zjbocon.com\/wp-content\/uploads\/2024\/11\/eto-sterilizer-hzbocon-4.png?resize=1050%2C600&ssl=1 3x"},"classes":[]},{"id":2534,"url":"https:\/\/zjbocon.com\/?p=2534","url_meta":{"origin":2018,"position":4},"title":"How to Loading Sterilization product when using eto gas sterilizer","author":"Bocon Technical Team","date":"2024-12-27","format":false,"excerpt":"Sterilizer-chamber-conveyor Sterilizer-chamber-conveyor Sterilizer-chamber-conveyor 8.4.1 Closing the eto gas sterilizer Discharge Door For double-door eto gas sterilizer, before loading sterilization goods, follow the closing procedure for the discharge door, and inflate the sealing gasket of the discharge door until the pressure reaches above 0.45 MPa to ensure a proper seal. Manually\u2026","rel":"","context":"In &quot;Company News&quot;","block_context":{"text":"Company News","link":"https:\/\/zjbocon.com\/?cat=133125"},"img":{"alt_text":"","src":"https:\/\/i0.wp.com\/zjbocon.com\/wp-content\/uploads\/2025\/09\/Automatic-Sterilizer-Chamber-Conveyor-1.webp?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/zjbocon.com\/wp-content\/uploads\/2025\/09\/Automatic-Sterilizer-Chamber-Conveyor-1.webp?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/zjbocon.com\/wp-content\/uploads\/2025\/09\/Automatic-Sterilizer-Chamber-Conveyor-1.webp?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/zjbocon.com\/wp-content\/uploads\/2025\/09\/Automatic-Sterilizer-Chamber-Conveyor-1.webp?resize=700%2C400&ssl=1 2x"},"classes":[]},{"id":2117,"url":"https:\/\/zjbocon.com\/?p=2117","url_meta":{"origin":2018,"position":5},"title":"Industry Eto Sterilizer Installation Verification","author":"Bocon Technical Team","date":"2024-11-06","format":false,"excerpt":"Industry Eto Sterilizer Installation Verification The installation of Industry Eto Sterilizer and all associated services should comply with the requirements of the construction and engineering drawings. It is recommended to verify the components of the Industry Eto Sterilizer to ensure the installation meets applicable standards and requirements. These equipment components\u2026","rel":"","context":"In &quot;ETO STERILIZER&quot;","block_context":{"text":"ETO STERILIZER","link":"https:\/\/zjbocon.com\/?cat=133124"},"img":{"alt_text":"","src":"https:\/\/i0.wp.com\/zjbocon.com\/wp-content\/uploads\/2024\/10\/sterilizer-station-design-2.webp?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/zjbocon.com\/wp-content\/uploads\/2024\/10\/sterilizer-station-design-2.webp?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/zjbocon.com\/wp-content\/uploads\/2024\/10\/sterilizer-station-design-2.webp?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/zjbocon.com\/wp-content\/uploads\/2024\/10\/sterilizer-station-design-2.webp?resize=700%2C400&ssl=1 2x"},"classes":[]}],"_links":{"self":[{"href":"https:\/\/zjbocon.com\/index.php?rest_route=\/wp\/v2\/posts\/2018","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/zjbocon.com\/index.php?rest_route=\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/zjbocon.com\/index.php?rest_route=\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/zjbocon.com\/index.php?rest_route=\/wp\/v2\/users\/234312599"}],"replies":[{"embeddable":true,"href":"https:\/\/zjbocon.com\/index.php?rest_route=%2Fwp%2Fv2%2Fcomments&post=2018"}],"version-history":[{"count":12,"href":"https:\/\/zjbocon.com\/index.php?rest_route=\/wp\/v2\/posts\/2018\/revisions"}],"predecessor-version":[{"id":2030,"href":"https:\/\/zjbocon.com\/index.php?rest_route=\/wp\/v2\/posts\/2018\/revisions\/2030"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/zjbocon.com\/index.php?rest_route=\/wp\/v2\/media\/1889"}],"wp:attachment":[{"href":"https:\/\/zjbocon.com\/index.php?rest_route=%2Fwp%2Fv2%2Fmedia&parent=2018"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/zjbocon.com\/index.php?rest_route=%2Fwp%2Fv2%2Fcategories&post=2018"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/zjbocon.com\/index.php?rest_route=%2Fwp%2Fv2%2Ftags&post=2018"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}