{"id":2047,"date":"2024-10-30T11:16:45","date_gmt":"2024-10-30T03:16:45","guid":{"rendered":"https:\/\/zjbocon.com\/?p=2047"},"modified":"2025-12-05T11:16:43","modified_gmt":"2025-12-05T03:16:43","slug":"iq-in-eto-sterilization-process","status":"publish","type":"post","link":"https:\/\/zjbocon.com\/?p=2047","title":{"rendered":"IQ IN ETO STERILIZATION PROCESS"},"content":{"rendered":"\n<p class=\"wp-block-paragraph\">Iq in eto sterilization جي عمل کي ظاھر ڪرڻ لاءِ ڪيو ويو آھي ته نسبندي جو سامان ۽ ڪا به ذيلي سامان فراهم ڪئي وئي آھي ۽ انھن جي وضاحتن جي مطابق انسٽال ڪئي وئي آھي. IQ انجام ڏيڻ کان اڳ، سامان ٺاهيندڙ FAT ۽ SAT کي يقيني بڻائيندو ته سامان عام طور تي پهچايو ويو آهي.<\/p>\n\n\n\n<div class=\"wp-block-uagb-image uagb-block-a3122174 wp-block-uagb-image--layout-default wp-block-uagb-image--effect-static wp-block-uagb-image--align-none\"><figure class=\"wp-block-uagb-image__figure\"><img loading=\"lazy\" decoding=\"async\" src=\"https:\/\/zjbocon.com\/wp-content\/uploads\/2025\/09\/Ethylene-Oxide-Sterilizer-Installation-Guide-1-1024x473.webp\" alt=\"\" class=\"uag-image-8475\" width=\"1024\" height=\"473\" title=\"Ethylene-Oxide-Sterilizer-Installation-Guide-1\" role=\"img\" \><\/figure><\/div>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"h-during-iq-the-following-events-need-to-be-further-identified-and-substantiated\">IQ دوران هيٺين واقعن کي وڌيڪ سڃاڻڻ ۽ ثابت ڪرڻ جي ضرورت آهي.<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">a. نسبندي جي عمل ۾ استعمال ٿيڻ وارو سامان، بشمول ڪا به ذيلي شيون، ان جي ڊيزائن جي وضاحتن جي تعميل ڪرڻ گهرجن. لاڳاپيل دستاويزن ۾ فنڪشنل ڊيزائن جي وضاحت، صارف جي ضرورتن جي وضاحت، ڊيزائن ڊرائنگ، وغيره شامل آهن.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">b. تصديق ڪريو ته سڀئي حصا (بشمول ڪنٽرول سافٽ ويئر) صحيح ڪم ڪري رهيا آهن؛ اھم ماپنگ آلات کي حساب ڪرڻ جي ضرورت آھي؛ اهم جزو معلومات کي رڪارڊ ڪيو وڃي؛<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">c.انصاف کي يقيني بڻائڻ ۽ استعمال ڪرڻ جو ماحول محفوظ آهي ۽ مقامي ضابطن سان تعميل آهي. حفاظت ۽ عملي جي صحت جي ضرورتن کي پورا ڪريو.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">d. حفاظت جي پيداوار ۽ آپريٽنگ پروسيسنگ دستاويزن کي ترقي ڪريو، بشمول سار سنڀال ۽ استثناء کي سنڀالڻ وارا دستاويز؛ آپريٽر ٽريننگ هلائڻ؛ آپريٽر صرف ڪم شروع ڪري سگھن ٿا جڏهن اهي قابليت رکن ٿا.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">e. IQ ٿي سگھي ٿو ھڪڙي وقت جي مشق آھي مخصوص سامان لاءِ جيڪو sterilization جي عمل لاءِ استعمال ڪيو پيو وڃي.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">f. اضافي IQ ضروري جزن جي تبديلين يا فنڪشنل تبديلين جي صورت ۾ پڻ انجام ڏيڻ جي ضرورت آهي<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"h-if-you-want-to-know-more-about-iq-in-eto-sterilization-process\">جيڪڏھن توھان وڌيڪ ڄاڻڻ چاھيو ٿا IQ بابت ETO Sterilization Process ۾<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">فون:<a href=\"https:\/\/wa.me\/8619975258603\">+8619975258603<\/a><\/p>\n\n\n\n<p class=\"wp-block-paragraph\">اي ميل:<a href=\"mailto:hayley@hzbocon.com\">hayley@hzbocon.com<\/a><\/p>\n\n\n\n<p class=\"wp-block-paragraph\">مقامي سائيٽ: ڪمرو 1202، Caitong Zhongxin، Xiasha ضلعي، Hangzhou شهر، Zhejiang صوبي، چين<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">ويب سائيٽ:<a href=\"https:\/\/www.hzbocon.com\/\">hzbocon.com<\/a><a href=\"https:\/\/zjbocon.com\/\">zjbocon.com<\/a><\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><\/p>\n","protected":false},"excerpt":{"rendered":"<p>a.Equipment to be used in the sterilization process, including any\u00a0ancillary items, shall comply with its design specifications.The corresponding documents include functional design specifications, user requirements specifications, design drawings, etc. (Equipment schematic diagram, energy supply diagram, electrical schematic diagram, system schematic diagram, etc.)<\/p>\n","protected":false},"author":234312599,"featured_media":8475,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_uag_custom_page_level_css":"","site-sidebar-layout":"default","site-content-layout":"","ast-site-content-layout":"default","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","ast-disable-related-posts":"","theme-transparent-header-meta":"","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"set","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"_jetpack_newsletter_access":"","_jetpack_dont_email_post_to_subs":false,"_jetpack_newsletter_tier_id":0,"_jetpack_memberships_contains_paywalled_content":false,"_jetpack_feature_clip_id":0,"_jetpack_memberships_contains_paid_content":false,"footnotes":"","jetpack_publicize_message":"","jetpack_publicize_feature_enabled":true,"jetpack_social_post_already_shared":false,"jetpack_social_options":{"image_generator_settings":{"template":"highway","enabled":false},"version":2},"jetpack_post_was_ever_published":false},"categories":[133124],"tags":[],"class_list":["post-2047","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-eto-sterilizer"],"yoast_head":"<!-- This site is optimized with the Yoast SEO Premium plugin v27.2 (Yoast SEO v28.0) - https:\/\/yoast.com\/product\/yoast-seo-premium-wordpress\/ -->\n<title>IQ IN ETO sterilization process - ETO sterilizer<\/title>\n<meta name=\"description\" content=\"Iq in eto sterilization process is undertaken to demonstrate that the equipment and any ancillary items have been\" \>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \>\n<link rel=\"canonical\" href=\"https:\/\/zjbocon.com\/?p=2047\" \>\n<meta property=\"og:locale\" content=\"en_US\" \>\n<meta property=\"og:type\" content=\"article\" \>\n<meta property=\"og:title\" content=\"IQ IN ETO STERILIZATION PROCESS\" \>\n<meta property=\"og:description\" content=\"Iq in eto sterilization process is undertaken to demonstrate that the equipment and any ancillary items have been\" \>\n<meta property=\"og:url\" content=\"https:\/\/zjbocon.com\/?p=2047\" \>\n<meta property=\"og:site_name\" content=\"ETO STERILIZER\" \>\n<meta property=\"article:publisher\" content=\"https:\/\/www.facebook.com\/profile.php?id=100088482339878\" \>\n<meta property=\"article:author\" content=\"https:\/\/www.facebook.com\/profile.php?id=100088482339878\" \>\n<meta property=\"article:published_time\" content=\"2024-10-30T03:16:45+00:00\" \>\n<meta property=\"article:modified_time\" content=\"2025-12-05T03:16:43+00:00\" \>\n<meta property=\"og:image\" content=\"https:\/\/zjbocon.com\/wp-content\/uploads\/2025\/09\/Ethylene-Oxide-Sterilizer-Installation-Guide-1-scaled.webp\" \>\n\t<meta property=\"og:image:width\" content=\"2560\" \>\n\t<meta property=\"og:image:height\" content=\"1183\" \>\n\t<meta property=\"og:image:type\" content=\"image\/webp\" \>\n<meta name=\"author\" content=\"Bocon Technical Team\" \>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \>\n<meta name=\"twitter:creator\" content=\"@BoconAnd\" \>\n<meta name=\"twitter:site\" content=\"@BoconAnd\" \>\n<meta name=\"twitter:label1\" content=\"Written by\" \>\n\t<meta name=\"twitter:data1\" content=\"Bocon Technical Team\" \>\n\t<meta name=\"twitter:label2\" content=\"Est. reading time\" \>\n\t<meta name=\"twitter:data2\" content=\"2 minutes\" \>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\\\/\\\/zjbocon.com\\\/?p=2047#article\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/zjbocon.com\\\/?p=2047\"},\"author\":{\"name\":\"Bocon Technical Team\",\"@id\":\"https:\\\/\\\/zjbocon.com\\\/#\\\/schema\\\/person\\\/f12be028b8ae9843a4396dcc8012b425\"},\"headline\":\"IQ IN ETO STERILIZATION PROCESS\",\"datePublished\":\"2024-10-30T03:16:45+00:00\",\"dateModified\":\"2025-12-05T03:16:43+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/zjbocon.com\\\/?p=2047\"},\"wordCount\":254,\"commentCount\":0,\"publisher\":{\"@id\":\"https:\\\/\\\/zjbocon.com\\\/#organization\"},\"image\":{\"@id\":\"https:\\\/\\\/zjbocon.com\\\/?p=2047#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/zjbocon.com\\\/wp-content\\\/uploads\\\/2025\\\/09\\\/Ethylene-Oxide-Sterilizer-Installation-Guide-1-scaled.webp\",\"articleSection\":[\"ETO STERILIZER\"],\"inLanguage\":\"sd\",\"potentialAction\":[{\"@type\":\"CommentAction\",\"name\":\"Comment\",\"target\":[\"https:\\\/\\\/zjbocon.com\\\/?p=2047#respond\"]}]},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/zjbocon.com\\\/?p=2047\",\"url\":\"https:\\\/\\\/zjbocon.com\\\/?p=2047\",\"name\":\"IQ IN ETO STERILIZATION PROCESS - ETO STERILIZER\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/zjbocon.com\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/zjbocon.com\\\/?p=2047#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/zjbocon.com\\\/?p=2047#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/zjbocon.com\\\/wp-content\\\/uploads\\\/2025\\\/09\\\/Ethylene-Oxide-Sterilizer-Installation-Guide-1-scaled.webp\",\"datePublished\":\"2024-10-30T03:16:45+00:00\",\"dateModified\":\"2025-12-05T03:16:43+00:00\",\"description\":\"Iq in eto sterilization process is undertaken to demonstrate that the sterilization equipment and any ancillary items have been\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/zjbocon.com\\\/?p=2047#breadcrumb\"},\"inLanguage\":\"sd\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/zjbocon.com\\\/?p=2047\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"sd\",\"@id\":\"https:\\\/\\\/zjbocon.com\\\/?p=2047#primaryimage\",\"url\":\"https:\\\/\\\/zjbocon.com\\\/wp-content\\\/uploads\\\/2025\\\/09\\\/Ethylene-Oxide-Sterilizer-Installation-Guide-1-scaled.webp\",\"contentUrl\":\"https:\\\/\\\/zjbocon.com\\\/wp-content\\\/uploads\\\/2025\\\/09\\\/Ethylene-Oxide-Sterilizer-Installation-Guide-1-scaled.webp\",\"width\":2560,\"height\":1183},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/zjbocon.com\\\/?p=2047#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/zjbocon.com\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"IQ IN ETO STERILIZATION PROCESS\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/zjbocon.com\\\/#website\",\"url\":\"https:\\\/\\\/zjbocon.com\\\/\",\"name\":\"ETO STERILIZER\",\"description\":\"One-stop Solution Supplier of Ethylene Oxide Sterilization\",\"publisher\":{\"@id\":\"https:\\\/\\\/zjbocon.com\\\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/zjbocon.com\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"sd\"},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/zjbocon.com\\\/#organization\",\"name\":\"ETO STERILIZER\",\"url\":\"https:\\\/\\\/zjbocon.com\\\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"sd\",\"@id\":\"https:\\\/\\\/zjbocon.com\\\/#\\\/schema\\\/logo\\\/image\\\/\",\"url\":\"https:\\\/\\\/zjbocon.com\\\/wp-content\\\/uploads\\\/2024\\\/10\\\/logo-1.webp\",\"contentUrl\":\"https:\\\/\\\/zjbocon.com\\\/wp-content\\\/uploads\\\/2024\\\/10\\\/logo-1.webp\",\"width\":180,\"height\":60,\"caption\":\"ETO STERILIZER\"},\"image\":{\"@id\":\"https:\\\/\\\/zjbocon.com\\\/#\\\/schema\\\/logo\\\/image\\\/\"},\"sameAs\":[\"https:\\\/\\\/www.facebook.com\\\/profile.php?id=100088482339878\",\"https:\\\/\\\/x.com\\\/BoconAnd\",\"https:\\\/\\\/www.linkedin.com\\\/in\\\/--06a221139\\\/\"]},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/zjbocon.com\\\/#\\\/schema\\\/person\\\/f12be028b8ae9843a4396dcc8012b425\",\"name\":\"Bocon Technical Team\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"sd\",\"@id\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/d7a825658be227f26b237e519f8541e05aabc9ff27b8eec4544a233a48c53be0?s=96&d=identicon&r=g\",\"url\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/d7a825658be227f26b237e519f8541e05aabc9ff27b8eec4544a233a48c53be0?s=96&d=identicon&r=g\",\"contentUrl\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/d7a825658be227f26b237e519f8541e05aabc9ff27b8eec4544a233a48c53be0?s=96&d=identicon&r=g\",\"caption\":\"Bocon Technical Team\"},\"sameAs\":[\"https:\\\/\\\/zjbocon.com\\\/\",\"https:\\\/\\\/www.facebook.com\\\/profile.php?id=100088482339878\",\"https:\\\/\\\/www.linkedin.com\\\/in\\\/\\\/hayley--968190269\\\/\"],\"url\":\"https:\\\/\\\/zjbocon.com\\\/?author=234312599\"}]}<\/script>\n<!-- \/ Yoast SEO Premium plugin. -->","yoast_head_json":{"title":"IQ IN ETO STERILIZATION PROCESS - ETO STERILIZER","description":"Iq in eto sterilization process is undertaken to demonstrate that the sterilization equipment and any ancillary items have been","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/zjbocon.com\/?p=2047","og_locale":"en_US","og_type":"article","og_title":"IQ IN ETO STERILIZATION PROCESS","og_description":"Iq in eto sterilization process is undertaken to demonstrate that the sterilization equipment and any ancillary items have been","og_url":"https:\/\/zjbocon.com\/?p=2047","og_site_name":"ETO STERILIZER","article_publisher":"https:\/\/www.facebook.com\/profile.php?id=100088482339878","article_author":"https:\/\/www.facebook.com\/profile.php?id=100088482339878","article_published_time":"2024-10-30T03:16:45+00:00","article_modified_time":"2025-12-05T03:16:43+00:00","og_image":[{"width":2560,"height":1183,"url":"https:\/\/zjbocon.com\/wp-content\/uploads\/2025\/09\/Ethylene-Oxide-Sterilizer-Installation-Guide-1-scaled.webp","type":"image\/webp"}],"author":"Bocon Technical Team","twitter_card":"summary_large_image","twitter_creator":"@BoconAnd","twitter_site":"@BoconAnd","twitter_misc":{"Written by":"Bocon Technical Team","Est. reading time":"2 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/zjbocon.com\/?p=2047#article","isPartOf":{"@id":"https:\/\/zjbocon.com\/?p=2047"},"author":{"name":"Bocon Technical Team","@id":"https:\/\/zjbocon.com\/#\/schema\/person\/f12be028b8ae9843a4396dcc8012b425"},"headline":"IQ IN ETO STERILIZATION PROCESS","datePublished":"2024-10-30T03:16:45+00:00","dateModified":"2025-12-05T03:16:43+00:00","mainEntityOfPage":{"@id":"https:\/\/zjbocon.com\/?p=2047"},"wordCount":254,"commentCount":0,"publisher":{"@id":"https:\/\/zjbocon.com\/#organization"},"image":{"@id":"https:\/\/zjbocon.com\/?p=2047#primaryimage"},"thumbnailUrl":"https:\/\/zjbocon.com\/wp-content\/uploads\/2025\/09\/Ethylene-Oxide-Sterilizer-Installation-Guide-1-scaled.webp","articleSection":["ETO STERILIZER"],"inLanguage":"sd","potentialAction":[{"@type":"CommentAction","name":"Comment","target":["https:\/\/zjbocon.com\/?p=2047#respond"]}]},{"@type":"WebPage","@id":"https:\/\/zjbocon.com\/?p=2047","url":"https:\/\/zjbocon.com\/?p=2047","name":"IQ IN ETO STERILIZATION PROCESS - ETO STERILIZER","isPartOf":{"@id":"https:\/\/zjbocon.com\/#website"},"primaryImageOfPage":{"@id":"https:\/\/zjbocon.com\/?p=2047#primaryimage"},"image":{"@id":"https:\/\/zjbocon.com\/?p=2047#primaryimage"},"thumbnailUrl":"https:\/\/zjbocon.com\/wp-content\/uploads\/2025\/09\/Ethylene-Oxide-Sterilizer-Installation-Guide-1-scaled.webp","datePublished":"2024-10-30T03:16:45+00:00","dateModified":"2025-12-05T03:16:43+00:00","description":"Iq in eto sterilization process is undertaken to demonstrate that the sterilization equipment and any ancillary items have been","breadcrumb":{"@id":"https:\/\/zjbocon.com\/?p=2047#breadcrumb"},"inLanguage":"sd","potentialAction":[{"@type":"ReadAction","target":["https:\/\/zjbocon.com\/?p=2047"]}]},{"@type":"ImageObject","inLanguage":"sd","@id":"https:\/\/zjbocon.com\/?p=2047#primaryimage","url":"https:\/\/zjbocon.com\/wp-content\/uploads\/2025\/09\/Ethylene-Oxide-Sterilizer-Installation-Guide-1-scaled.webp","contentUrl":"https:\/\/zjbocon.com\/wp-content\/uploads\/2025\/09\/Ethylene-Oxide-Sterilizer-Installation-Guide-1-scaled.webp","width":2560,"height":1183},{"@type":"BreadcrumbList","@id":"https:\/\/zjbocon.com\/?p=2047#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/zjbocon.com\/"},{"@type":"ListItem","position":2,"name":"IQ IN ETO STERILIZATION PROCESS"}]},{"@type":"WebSite","@id":"https:\/\/zjbocon.com\/#website","url":"https:\/\/zjbocon.com\/","name":"ETO STERILIZER","description":"One-stop Solution Supplier of Ethylene Oxide Sterilization","publisher":{"@id":"https:\/\/zjbocon.com\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/zjbocon.com\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"sd"},{"@type":"Organization","@id":"https:\/\/zjbocon.com\/#organization","name":"ETO STERILIZER","url":"https:\/\/zjbocon.com\/","logo":{"@type":"ImageObject","inLanguage":"sd","@id":"https:\/\/zjbocon.com\/#\/schema\/logo\/image\/","url":"https:\/\/zjbocon.com\/wp-content\/uploads\/2024\/10\/logo-1.webp","contentUrl":"https:\/\/zjbocon.com\/wp-content\/uploads\/2024\/10\/logo-1.webp","width":180,"height":60,"caption":"ETO STERILIZER"},"image":{"@id":"https:\/\/zjbocon.com\/#\/schema\/logo\/image\/"},"sameAs":["https:\/\/www.facebook.com\/profile.php?id=100088482339878","https:\/\/x.com\/BoconAnd","https:\/\/www.linkedin.com\/in\/--06a221139\/"]},{"@type":"Person","@id":"https:\/\/zjbocon.com\/#\/schema\/person\/f12be028b8ae9843a4396dcc8012b425","name":"Bocon Technical Team","image":{"@type":"ImageObject","inLanguage":"sd","@id":"https:\/\/secure.gravatar.com\/avatar\/d7a825658be227f26b237e519f8541e05aabc9ff27b8eec4544a233a48c53be0?s=96&d=identicon&r=g","url":"https:\/\/secure.gravatar.com\/avatar\/d7a825658be227f26b237e519f8541e05aabc9ff27b8eec4544a233a48c53be0?s=96&d=identicon&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/d7a825658be227f26b237e519f8541e05aabc9ff27b8eec4544a233a48c53be0?s=96&d=identicon&r=g","caption":"Bocon Technical Team"},"sameAs":["https:\/\/zjbocon.com\/","https:\/\/www.facebook.com\/profile.php?id=100088482339878","https:\/\/www.linkedin.com\/in\/\/hayley--968190269\/"],"url":"https:\/\/zjbocon.com\/?author=234312599"}]}},"jetpack_publicize_connections":[],"jetpack_featured_media_url":"https:\/\/zjbocon.com\/wp-content\/uploads\/2025\/09\/Ethylene-Oxide-Sterilizer-Installation-Guide-1-scaled.webp","uagb_featured_image_src":{"full":["https:\/\/zjbocon.com\/wp-content\/uploads\/2025\/09\/Ethylene-Oxide-Sterilizer-Installation-Guide-1-scaled.webp",2560,1183,false],"thumbnail":["https:\/\/zjbocon.com\/wp-content\/uploads\/2025\/09\/Ethylene-Oxide-Sterilizer-Installation-Guide-1-150x150.webp",150,150,true],"medium":["https:\/\/zjbocon.com\/wp-content\/uploads\/2025\/09\/Ethylene-Oxide-Sterilizer-Installation-Guide-1-300x139.webp",300,139,true],"medium_large":["https:\/\/zjbocon.com\/wp-content\/uploads\/2025\/09\/Ethylene-Oxide-Sterilizer-Installation-Guide-1-768x355.webp",768,355,true],"large":["https:\/\/zjbocon.com\/wp-content\/uploads\/2025\/09\/Ethylene-Oxide-Sterilizer-Installation-Guide-1-1024x473.webp",1024,473,true],"1536x1536":["https:\/\/zjbocon.com\/wp-content\/uploads\/2025\/09\/Ethylene-Oxide-Sterilizer-Installation-Guide-1-1536x710.webp",1536,710,true],"2048x2048":["https:\/\/zjbocon.com\/wp-content\/uploads\/2025\/09\/Ethylene-Oxide-Sterilizer-Installation-Guide-1-2048x946.webp",2048,946,true],"woocommerce_thumbnail":["https:\/\/zjbocon.com\/wp-content\/uploads\/2025\/09\/Ethylene-Oxide-Sterilizer-Installation-Guide-1-600x600.webp",600,600,true],"woocommerce_single":["https:\/\/zjbocon.com\/wp-content\/uploads\/2025\/09\/Ethylene-Oxide-Sterilizer-Installation-Guide-1-600x277.webp",600,277,true],"woocommerce_gallery_thumbnail":["https:\/\/zjbocon.com\/wp-content\/uploads\/2025\/09\/Ethylene-Oxide-Sterilizer-Installation-Guide-1-100x100.webp",100,100,true]},"uagb_author_info":{"display_name":"Bocon Technical Team","author_link":"https:\/\/zjbocon.com\/?author=234312599"},"uagb_comment_info":17,"uagb_excerpt":"a.Equipment to be used in the sterilization process, including any\u00a0ancillary items, shall comply with its design specifications.The corresponding documents include functional design specifications, user requirements specifications, design drawings, etc. (Equipment schematic diagram, energy supply diagram, electrical schematic diagram, system schematic diagram, etc.)","jetpack_likes_enabled":true,"jetpack_sharing_enabled":true,"jetpack_shortlink":"https:\/\/wp.me\/pgZDV6-x1","jetpack-related-posts":[{"id":2013,"url":"https:\/\/zjbocon.com\/?p=2013","url_meta":{"origin":2047,"position":0},"title":"Purpose for eto sterilization validation","author":"Bocon Technical Team","date":"2024-10-28","format":false,"excerpt":"1.Purpose\u00a0for validation eto sterilization 1.1.the obtain of eto sterilization validation evidence that the equipment used for ETO sterilization has been provided and installed in accordance with its specification and can stably operate within predetermined limits and consistently performs in accordance with predetermined criteria and thereby yields product meeting its specification.\u2026","rel":"","context":"In &quot;ETO STERILIZER&quot;","block_context":{"text":"ETO STERILIZER","link":"https:\/\/zjbocon.com\/?cat=133124"},"img":{"alt_text":"eto sterilization validation","src":"https:\/\/i0.wp.com\/zjbocon.com\/wp-content\/uploads\/2024\/10\/Qualification_Services-2.webp?resize=350%2C200","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/zjbocon.com\/wp-content\/uploads\/2024\/10\/Qualification_Services-2.webp?resize=350%2C200 1x, https:\/\/i0.wp.com\/zjbocon.com\/wp-content\/uploads\/2024\/10\/Qualification_Services-2.webp?resize=525%2C300 1.5x, https:\/\/i0.wp.com\/zjbocon.com\/wp-content\/uploads\/2024\/10\/Qualification_Services-2.webp?resize=700%2C400 2x"},"classes":[]},{"id":7286,"url":"https:\/\/zjbocon.com\/?p=7286","url_meta":{"origin":2047,"position":1},"title":"ETO Sterilization Re-qualification","author":"Bocon Technical Team","date":"2025-07-29","format":false,"excerpt":"ETO Sterilization Re-qualification Requirements 1. Re-qualification Frequency \u2022\u00a0Minimum annual requirement\u2022 At least once per year, verification data, subsequent re-validation data, and routine processing data must be reviewed\u2022 The scope of re-qualification must be determined and documented\u2022 The review procedure shall be documented 2. Is Re-qualification Needed if No Product Changes\u2026","rel":"","context":"In &quot;Company News&quot;","block_context":{"text":"Company News","link":"https:\/\/zjbocon.com\/?cat=133125"},"img":{"alt_text":"","src":"https:\/\/i0.wp.com\/zjbocon.com\/wp-content\/uploads\/2025\/09\/eto-sterilizer-9.webp?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/zjbocon.com\/wp-content\/uploads\/2025\/09\/eto-sterilizer-9.webp?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/zjbocon.com\/wp-content\/uploads\/2025\/09\/eto-sterilizer-9.webp?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/zjbocon.com\/wp-content\/uploads\/2025\/09\/eto-sterilizer-9.webp?resize=700%2C400&ssl=1 2x, https:\/\/i0.wp.com\/zjbocon.com\/wp-content\/uploads\/2025\/09\/eto-sterilizer-9.webp?resize=1050%2C600&ssl=1 3x"},"classes":[]},{"id":2076,"url":"https:\/\/zjbocon.com\/?p=2076","url_meta":{"origin":2047,"position":2},"title":"PQ in Ethylene oxide sterilization chamber","author":"Bocon Technical Team","date":"2024-10-31","format":false,"excerpt":"PQ is the stage of validation that uses Ethylene oxide sterilization chamber to demonstrate that the Ethylene oxide sterilization equipment consistently operates in accordance with predetermined acceptance criteria and the process yields a product that is sterile and meets the specified requirements.","rel":"","context":"In &quot;ETO STERILIZER&quot;","block_context":{"text":"ETO STERILIZER","link":"https:\/\/zjbocon.com\/?cat=133124"},"img":{"alt_text":"","src":"https:\/\/i0.wp.com\/zjbocon.com\/wp-content\/uploads\/2025\/09\/eto-sterilizer-1.webp?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/zjbocon.com\/wp-content\/uploads\/2025\/09\/eto-sterilizer-1.webp?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/zjbocon.com\/wp-content\/uploads\/2025\/09\/eto-sterilizer-1.webp?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/zjbocon.com\/wp-content\/uploads\/2025\/09\/eto-sterilizer-1.webp?resize=700%2C400&ssl=1 2x, https:\/\/i0.wp.com\/zjbocon.com\/wp-content\/uploads\/2025\/09\/eto-sterilizer-1.webp?resize=1050%2C600&ssl=1 3x"},"classes":[]},{"id":2064,"url":"https:\/\/zjbocon.com\/?p=2064","url_meta":{"origin":2047,"position":3},"title":"OQ IN ETO STERILIZATION MACHINE","author":"Bocon Technical Team","date":"2024-10-31","format":false,"excerpt":"In OQ, the performance of the relevant auxiliary system should be determined and the software system should be tested by simulating the fault conditions.","rel":"","context":"In &quot;ETO STERILIZER&quot;","block_context":{"text":"ETO STERILIZER","link":"https:\/\/zjbocon.com\/?cat=133124"},"img":{"alt_text":"","src":"https:\/\/i0.wp.com\/zjbocon.com\/wp-content\/uploads\/2025\/09\/Ethylene-Oxide-Sterilizer-Installation-Guide-1-scaled.webp?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/zjbocon.com\/wp-content\/uploads\/2025\/09\/Ethylene-Oxide-Sterilizer-Installation-Guide-1-scaled.webp?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/zjbocon.com\/wp-content\/uploads\/2025\/09\/Ethylene-Oxide-Sterilizer-Installation-Guide-1-scaled.webp?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/zjbocon.com\/wp-content\/uploads\/2025\/09\/Ethylene-Oxide-Sterilizer-Installation-Guide-1-scaled.webp?resize=700%2C400&ssl=1 2x, https:\/\/i0.wp.com\/zjbocon.com\/wp-content\/uploads\/2025\/09\/Ethylene-Oxide-Sterilizer-Installation-Guide-1-scaled.webp?resize=1050%2C600&ssl=1 3x, https:\/\/i0.wp.com\/zjbocon.com\/wp-content\/uploads\/2025\/09\/Ethylene-Oxide-Sterilizer-Installation-Guide-1-scaled.webp?resize=1400%2C800&ssl=1 4x"},"classes":[]},{"id":2471,"url":"https:\/\/zjbocon.com\/?p=2471","url_meta":{"origin":2047,"position":4},"title":"Safety Requirements for Using Ethylene Oxide in sterilization","author":"Bocon Technical Team","date":"2024-12-23","format":false,"excerpt":"when Ethylene Oxide in sterilization chamber should be equipped with fire prevention facilities. Ethylene oxide cylinders should be stored separately in a dry, well-ventilated room, with strict prohibition of smoking and open flames. The lighting in the sterilization chamber should be explosion-proof, and any electrical appliances that may cause electric\u2026","rel":"","context":"In &quot;Company News&quot;","block_context":{"text":"Company News","link":"https:\/\/zjbocon.com\/?cat=133125"},"img":{"alt_text":"","src":"https:\/\/i0.wp.com\/zjbocon.com\/wp-content\/uploads\/2024\/10\/Electrical-Scale.png?resize=350%2C200","width":350,"height":200},"classes":[]},{"id":8776,"url":"https:\/\/zjbocon.com\/?p=8776","url_meta":{"origin":2047,"position":5},"title":"How to Test ETO Gas Sterilization Test Materials","author":"Bocon Technical Team","date":"2025-11-25","format":false,"excerpt":"When it comes to ETO gas sterilization, testing is an essential part of ensuring the effectiveness and safety of the sterilization process. ETO GAS STERILIZATION TEST MATERIALS","rel":"","context":"In &quot;Company News&quot;","block_context":{"text":"Company News","link":"https:\/\/zjbocon.com\/?cat=133125"},"img":{"alt_text":"","src":"https:\/\/i0.wp.com\/zjbocon.com\/wp-content\/uploads\/2025\/09\/ethylene-oxide-sterilization-68.webp?resize=350%2C200&ssl=1","width":350,"height":200},"classes":[]}],"_links":{"self":[{"href":"https:\/\/zjbocon.com\/index.php?rest_route=\/wp\/v2\/posts\/2047","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/zjbocon.com\/index.php?rest_route=\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/zjbocon.com\/index.php?rest_route=\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/zjbocon.com\/index.php?rest_route=\/wp\/v2\/users\/234312599"}],"replies":[{"embeddable":true,"href":"https:\/\/zjbocon.com\/index.php?rest_route=%2Fwp%2Fv2%2Fcomments&post=2047"}],"version-history":[{"count":10,"href":"https:\/\/zjbocon.com\/index.php?rest_route=\/wp\/v2\/posts\/2047\/revisions"}],"predecessor-version":[{"id":8903,"href":"https:\/\/zjbocon.com\/index.php?rest_route=\/wp\/v2\/posts\/2047\/revisions\/8903"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/zjbocon.com\/index.php?rest_route=\/wp\/v2\/media\/8475"}],"wp:attachment":[{"href":"https:\/\/zjbocon.com\/index.php?rest_route=%2Fwp%2Fv2%2Fmedia&parent=2047"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/zjbocon.com\/index.php?rest_route=%2Fwp%2Fv2%2Fcategories&post=2047"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/zjbocon.com\/index.php?rest_route=%2Fwp%2Fv2%2Ftags&post=2047"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}