{"id":2439,"date":"2024-12-17T11:01:22","date_gmt":"2024-12-17T03:01:22","guid":{"rendered":"https:\/\/zjbocon.com\/?p=2439"},"modified":"2025-12-05T10:53:23","modified_gmt":"2025-12-05T02:53:23","slug":"preparatory-work-before-eto-sterilization","status":"publish","type":"post","link":"https:\/\/zjbocon.com\/?p=2439","title":{"rendered":"Preparatory Work Before eto Sterilization"},"content":{"rendered":"\n<div class=\"wp-block-uagb-image uagb-block-2684756c wp-block-uagb-image--layout-default wp-block-uagb-image--effect-static wp-block-uagb-image--align-none\"><figure class=\"wp-block-uagb-image__figure\"><img loading=\"lazy\" decoding=\"async\" src=\"https:\/\/zjbocon.com\/wp-content\/uploads\/2025\/09\/sterilizer-station-design-2.webp\" alt=\"\" class=\"uag-image-8346\" width=\"1024\" height=\"473\" title=\"sterilizer-station-design-2\" role=\"img\" \><\/figure><\/div>\n\n\n\n<ol class=\"wp-block-list\">\n<li><strong>ظاهري معائنو:<\/strong> مٿاڇري تي ڪنهن به نقصان لاء مکيه يونٽ، ڪنٽرول ريڪ، ۽ برقي ڪنٽرول ڪابينا چيڪ ڪريو.<\/li>\n\n\n\n<li><strong>بجلي جي فراهمي جي چڪاس:<\/strong> پڪ ڪريو ته بجلي جي فراهمي جي ضرورتن کي پورو ڪرڻ، ۽ پاڻي جي پمپ ۽ ويڪيوم پمپ جي گردش جي هدايت کي چيڪ ڪريو.<\/li>\n\n\n\n<li><strong>پاور آن:<\/strong> پاور آن ڪريو ۽ ڏسو ته ڇا ڊوائيسز تي ڊسپلي قدر عام آھن. جيڪڏهن نه، بجلي بند ڪريو، معائنو ۽ مرمت ڪريو، پوء ٻيهر شروع ڪريو.<\/li>\n\n\n\n<li><strong>پائپ لائن جي چڪاس:<\/strong> چيڪ ڪريو پاڻي جي فراهمي، ويڪيوم، ۽ دوائن جي ترسيل پائپ لائنن ۾ ليڪ، ۽ تصديق ڪريو ته سڀئي والوز اسٽينڊ بائي پوزيشن ۾ آهن؛ جيڪڏهن ضروري هجي ته ترتيب ڏيو.<\/li>\n\n\n\n<li><strong>پيرا ميٽر سيٽنگ:<\/strong> For example, set the medication amount by placing the medication bottle on an electronic scale (scale provided by the user), confirm the weight of the bottle, start the vacuum pump to reach the set pressure value, and open the medication bottle to deliver the medication. Typically, the medication amount during eto Sterilization is 400-800 mg\/L (referring to the amount of pure ethylene oxide input; if using a mixture of gases with ethylene oxide, ensure that the amount of ethylene oxide meets this requirement). When the medication weight reaches the standard, the pressure at this point indicates the amount of medication delivered.<\/li>\n\n\n\n<li>هر eto اسٽريلائيزيشن چڪر کان اڳ، تصديق ڪريو ته پيٽرولر سيٽنگون sterilized شين جي بيچ جي ضرورتن کي پورا ڪن؛ ٻي صورت ۾، eto Sterilization parameters کي ري سيٽ ڪريو.<\/li>\n<\/ol>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"h-if-you-want-to-know-more-about-ethylene-oxide-sterilization\">جيڪڏھن توھان وڌيڪ ڄاڻڻ چاھيو ٿا ايٿيلين آڪسائيڊ اسٽريلائيزيشن بابت<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">فون:<a href=\"https:\/\/wa.me\/8619975258603\">+8619975258603<\/a><\/p>\n\n\n\n<p class=\"wp-block-paragraph\">اي ميل:<a href=\"mailto:hayley@hzbocon.com\">hayley@hzbocon.com<\/a><\/p>\n\n\n\n<p class=\"wp-block-paragraph\">مقامي سائيٽ: ڪمرو 1202، Caitong Zhongxin، Xiasha ضلعي، Hangzhou شهر، Zhejiang صوبي، چين<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">ويب سائيٽ:<a href=\"https:\/\/www.hzbocon.com\/\">hzbocon.com<\/a><a href=\"https:\/\/zjbocon.com\/\">&nbsp;zjbocon.com<\/a><\/p>\n","protected":false},"excerpt":{"rendered":"<p>ظاهري معائنو: مٿاڇري تي ڪنهن به نقصان لاء مکيه يونٽ، ڪنٽرول ريڪ، ۽ برقي ڪنٽرول ڪابينا چيڪ ڪريو.<\/p>\n","protected":false},"author":234312599,"featured_media":8346,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_uag_custom_page_level_css":"","site-sidebar-layout":"default","site-content-layout":"","ast-site-content-layout":"default","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","ast-disable-related-posts":"","theme-transparent-header-meta":"","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"set","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"_jetpack_newsletter_access":"","_jetpack_dont_email_post_to_subs":false,"_jetpack_newsletter_tier_id":0,"_jetpack_memberships_contains_paywalled_content":false,"_jetpack_feature_clip_id":0,"_jetpack_memberships_contains_paid_content":false,"footnotes":"","jetpack_publicize_message":"","jetpack_publicize_feature_enabled":true,"jetpack_social_post_already_shared":false,"jetpack_social_options":{"image_generator_settings":{"template":"highway","enabled":false},"version":2},"jetpack_post_was_ever_published":false},"categories":[133125,133124],"tags":[],"class_list":["post-2439","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-company-news","category-eto-sterilizer"],"yoast_head":"<!-- This site is optimized with the Yoast SEO Premium plugin v27.2 (Yoast SEO v28.0) - https:\/\/yoast.com\/product\/yoast-seo-premium-wordpress\/ -->\n<title>Eto Sterilization کان اڳ تياري وارو ڪم - ETO STERILIZER<\/title>\n<meta name=\"description\" content=\"Preparatory Work Before eto Sterilization Appearance Inspection: Check the main unit, control rack, and electrical\" \>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \>\n<link rel=\"canonical\" href=\"https:\/\/zjbocon.com\/?p=2439\" \>\n<meta property=\"og:locale\" content=\"en_US\" \>\n<meta property=\"og:type\" content=\"article\" \>\n<meta property=\"og:title\" content=\"Preparatory Work Before eto Sterilization\" \>\n<meta property=\"og:description\" content=\"Preparatory Work Before eto Sterilization Appearance Inspection: Check the main unit, control rack, and electrical\" \>\n<meta property=\"og:url\" content=\"https:\/\/zjbocon.com\/?p=2439\" \>\n<meta property=\"og:site_name\" content=\"ETO STERILIZER\" \>\n<meta property=\"article:publisher\" content=\"https:\/\/www.facebook.com\/profile.php?id=100088482339878\" \>\n<meta property=\"article:author\" content=\"https:\/\/www.facebook.com\/profile.php?id=100088482339878\" \>\n<meta property=\"article:published_time\" content=\"2024-12-17T03:01:22+00:00\" \>\n<meta property=\"article:modified_time\" content=\"2025-12-05T02:53:23+00:00\" \>\n<meta property=\"og:image\" content=\"https:\/\/zjbocon.com\/wp-content\/uploads\/2025\/09\/sterilizer-station-design-2.webp\" \>\n\t<meta property=\"og:image:width\" content=\"800\" \>\n\t<meta property=\"og:image:height\" content=\"400\" \>\n\t<meta property=\"og:image:type\" content=\"image\/webp\" \>\n<meta name=\"author\" content=\"Bocon Technical Team\" \>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \>\n<meta name=\"twitter:creator\" content=\"@BoconAnd\" \>\n<meta name=\"twitter:site\" content=\"@BoconAnd\" \>\n<meta name=\"twitter:label1\" content=\"Written by\" \>\n\t<meta name=\"twitter:data1\" content=\"Bocon Technical Team\" \>\n\t<meta name=\"twitter:label2\" content=\"Est. reading time\" \>\n\t<meta name=\"twitter:data2\" content=\"2 minutes\" \>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\\\/\\\/zjbocon.com\\\/?p=2439#article\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/zjbocon.com\\\/?p=2439\"},\"author\":{\"name\":\"Bocon Technical Team\",\"@id\":\"https:\\\/\\\/zjbocon.com\\\/#\\\/schema\\\/person\\\/f12be028b8ae9843a4396dcc8012b425\"},\"headline\":\"Preparatory Work Before eto Sterilization\",\"datePublished\":\"2024-12-17T03:01:22+00:00\",\"dateModified\":\"2025-12-05T02:53:23+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/zjbocon.com\\\/?p=2439\"},\"wordCount\":264,\"commentCount\":0,\"publisher\":{\"@id\":\"https:\\\/\\\/zjbocon.com\\\/#organization\"},\"image\":{\"@id\":\"https:\\\/\\\/zjbocon.com\\\/?p=2439#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/zjbocon.com\\\/wp-content\\\/uploads\\\/2025\\\/09\\\/sterilizer-station-design-2.webp\",\"articleSection\":[\"Company News\",\"ETO STERILIZER\"],\"inLanguage\":\"sd\",\"potentialAction\":[{\"@type\":\"CommentAction\",\"name\":\"Comment\",\"target\":[\"https:\\\/\\\/zjbocon.com\\\/?p=2439#respond\"]}]},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/zjbocon.com\\\/?p=2439\",\"url\":\"https:\\\/\\\/zjbocon.com\\\/?p=2439\",\"name\":\"Preparatory Work Before eto Sterilization - ETO STERILIZER\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/zjbocon.com\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/zjbocon.com\\\/?p=2439#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/zjbocon.com\\\/?p=2439#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/zjbocon.com\\\/wp-content\\\/uploads\\\/2025\\\/09\\\/sterilizer-station-design-2.webp\",\"datePublished\":\"2024-12-17T03:01:22+00:00\",\"dateModified\":\"2025-12-05T02:53:23+00:00\",\"description\":\"Preparatory Work Before eto Sterilization Appearance Inspection: Check the main unit, control rack, and electrical\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/zjbocon.com\\\/?p=2439#breadcrumb\"},\"inLanguage\":\"sd\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/zjbocon.com\\\/?p=2439\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"sd\",\"@id\":\"https:\\\/\\\/zjbocon.com\\\/?p=2439#primaryimage\",\"url\":\"https:\\\/\\\/zjbocon.com\\\/wp-content\\\/uploads\\\/2025\\\/09\\\/sterilizer-station-design-2.webp\",\"contentUrl\":\"https:\\\/\\\/zjbocon.com\\\/wp-content\\\/uploads\\\/2025\\\/09\\\/sterilizer-station-design-2.webp\",\"width\":800,\"height\":400},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/zjbocon.com\\\/?p=2439#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/zjbocon.com\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Preparatory Work Before eto Sterilization\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/zjbocon.com\\\/#website\",\"url\":\"https:\\\/\\\/zjbocon.com\\\/\",\"name\":\"ETO STERILIZER\",\"description\":\"One-stop Solution Supplier of Ethylene Oxide Sterilization\",\"publisher\":{\"@id\":\"https:\\\/\\\/zjbocon.com\\\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/zjbocon.com\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"sd\"},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/zjbocon.com\\\/#organization\",\"name\":\"ETO STERILIZER\",\"url\":\"https:\\\/\\\/zjbocon.com\\\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"sd\",\"@id\":\"https:\\\/\\\/zjbocon.com\\\/#\\\/schema\\\/logo\\\/image\\\/\",\"url\":\"https:\\\/\\\/zjbocon.com\\\/wp-content\\\/uploads\\\/2024\\\/10\\\/logo-1.webp\",\"contentUrl\":\"https:\\\/\\\/zjbocon.com\\\/wp-content\\\/uploads\\\/2024\\\/10\\\/logo-1.webp\",\"width\":180,\"height\":60,\"caption\":\"ETO STERILIZER\"},\"image\":{\"@id\":\"https:\\\/\\\/zjbocon.com\\\/#\\\/schema\\\/logo\\\/image\\\/\"},\"sameAs\":[\"https:\\\/\\\/www.facebook.com\\\/profile.php?id=100088482339878\",\"https:\\\/\\\/x.com\\\/BoconAnd\",\"https:\\\/\\\/www.linkedin.com\\\/in\\\/--06a221139\\\/\"]},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/zjbocon.com\\\/#\\\/schema\\\/person\\\/f12be028b8ae9843a4396dcc8012b425\",\"name\":\"Bocon Technical Team\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"sd\",\"@id\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/d7a825658be227f26b237e519f8541e05aabc9ff27b8eec4544a233a48c53be0?s=96&d=identicon&r=g\",\"url\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/d7a825658be227f26b237e519f8541e05aabc9ff27b8eec4544a233a48c53be0?s=96&d=identicon&r=g\",\"contentUrl\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/d7a825658be227f26b237e519f8541e05aabc9ff27b8eec4544a233a48c53be0?s=96&d=identicon&r=g\",\"caption\":\"Bocon Technical Team\"},\"sameAs\":[\"https:\\\/\\\/zjbocon.com\\\/\",\"https:\\\/\\\/www.facebook.com\\\/profile.php?id=100088482339878\",\"https:\\\/\\\/www.linkedin.com\\\/in\\\/\\\/hayley--968190269\\\/\"],\"url\":\"https:\\\/\\\/zjbocon.com\\\/?author=234312599\"}]}<\/script>\n<!-- \/ Yoast SEO Premium plugin. -->","yoast_head_json":{"title":"Preparatory Work Before eto Sterilization - ETO STERILIZER","description":"Preparatory Work Before eto Sterilization Appearance Inspection: Check the main unit, control rack, and electrical","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/zjbocon.com\/?p=2439","og_locale":"en_US","og_type":"article","og_title":"Preparatory Work Before eto Sterilization","og_description":"Preparatory Work Before eto Sterilization Appearance Inspection: Check the main unit, control rack, and electrical","og_url":"https:\/\/zjbocon.com\/?p=2439","og_site_name":"ETO STERILIZER","article_publisher":"https:\/\/www.facebook.com\/profile.php?id=100088482339878","article_author":"https:\/\/www.facebook.com\/profile.php?id=100088482339878","article_published_time":"2024-12-17T03:01:22+00:00","article_modified_time":"2025-12-05T02:53:23+00:00","og_image":[{"width":800,"height":400,"url":"https:\/\/zjbocon.com\/wp-content\/uploads\/2025\/09\/sterilizer-station-design-2.webp","type":"image\/webp"}],"author":"Bocon Technical Team","twitter_card":"summary_large_image","twitter_creator":"@BoconAnd","twitter_site":"@BoconAnd","twitter_misc":{"Written by":"Bocon Technical Team","Est. reading time":"2 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/zjbocon.com\/?p=2439#article","isPartOf":{"@id":"https:\/\/zjbocon.com\/?p=2439"},"author":{"name":"Bocon Technical Team","@id":"https:\/\/zjbocon.com\/#\/schema\/person\/f12be028b8ae9843a4396dcc8012b425"},"headline":"Preparatory Work Before eto Sterilization","datePublished":"2024-12-17T03:01:22+00:00","dateModified":"2025-12-05T02:53:23+00:00","mainEntityOfPage":{"@id":"https:\/\/zjbocon.com\/?p=2439"},"wordCount":264,"commentCount":0,"publisher":{"@id":"https:\/\/zjbocon.com\/#organization"},"image":{"@id":"https:\/\/zjbocon.com\/?p=2439#primaryimage"},"thumbnailUrl":"https:\/\/zjbocon.com\/wp-content\/uploads\/2025\/09\/sterilizer-station-design-2.webp","articleSection":["Company News","ETO STERILIZER"],"inLanguage":"sd","potentialAction":[{"@type":"CommentAction","name":"Comment","target":["https:\/\/zjbocon.com\/?p=2439#respond"]}]},{"@type":"WebPage","@id":"https:\/\/zjbocon.com\/?p=2439","url":"https:\/\/zjbocon.com\/?p=2439","name":"Preparatory Work Before eto Sterilization - ETO STERILIZER","isPartOf":{"@id":"https:\/\/zjbocon.com\/#website"},"primaryImageOfPage":{"@id":"https:\/\/zjbocon.com\/?p=2439#primaryimage"},"image":{"@id":"https:\/\/zjbocon.com\/?p=2439#primaryimage"},"thumbnailUrl":"https:\/\/zjbocon.com\/wp-content\/uploads\/2025\/09\/sterilizer-station-design-2.webp","datePublished":"2024-12-17T03:01:22+00:00","dateModified":"2025-12-05T02:53:23+00:00","description":"Preparatory Work Before eto Sterilization Appearance Inspection: Check the main unit, control rack, and electrical","breadcrumb":{"@id":"https:\/\/zjbocon.com\/?p=2439#breadcrumb"},"inLanguage":"sd","potentialAction":[{"@type":"ReadAction","target":["https:\/\/zjbocon.com\/?p=2439"]}]},{"@type":"ImageObject","inLanguage":"sd","@id":"https:\/\/zjbocon.com\/?p=2439#primaryimage","url":"https:\/\/zjbocon.com\/wp-content\/uploads\/2025\/09\/sterilizer-station-design-2.webp","contentUrl":"https:\/\/zjbocon.com\/wp-content\/uploads\/2025\/09\/sterilizer-station-design-2.webp","width":800,"height":400},{"@type":"BreadcrumbList","@id":"https:\/\/zjbocon.com\/?p=2439#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/zjbocon.com\/"},{"@type":"ListItem","position":2,"name":"Preparatory Work Before eto Sterilization"}]},{"@type":"WebSite","@id":"https:\/\/zjbocon.com\/#website","url":"https:\/\/zjbocon.com\/","name":"ETO STERILIZER","description":"One-stop Solution Supplier of Ethylene Oxide Sterilization","publisher":{"@id":"https:\/\/zjbocon.com\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/zjbocon.com\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"sd"},{"@type":"Organization","@id":"https:\/\/zjbocon.com\/#organization","name":"ETO STERILIZER","url":"https:\/\/zjbocon.com\/","logo":{"@type":"ImageObject","inLanguage":"sd","@id":"https:\/\/zjbocon.com\/#\/schema\/logo\/image\/","url":"https:\/\/zjbocon.com\/wp-content\/uploads\/2024\/10\/logo-1.webp","contentUrl":"https:\/\/zjbocon.com\/wp-content\/uploads\/2024\/10\/logo-1.webp","width":180,"height":60,"caption":"ETO STERILIZER"},"image":{"@id":"https:\/\/zjbocon.com\/#\/schema\/logo\/image\/"},"sameAs":["https:\/\/www.facebook.com\/profile.php?id=100088482339878","https:\/\/x.com\/BoconAnd","https:\/\/www.linkedin.com\/in\/--06a221139\/"]},{"@type":"Person","@id":"https:\/\/zjbocon.com\/#\/schema\/person\/f12be028b8ae9843a4396dcc8012b425","name":"Bocon Technical Team","image":{"@type":"ImageObject","inLanguage":"sd","@id":"https:\/\/secure.gravatar.com\/avatar\/d7a825658be227f26b237e519f8541e05aabc9ff27b8eec4544a233a48c53be0?s=96&d=identicon&r=g","url":"https:\/\/secure.gravatar.com\/avatar\/d7a825658be227f26b237e519f8541e05aabc9ff27b8eec4544a233a48c53be0?s=96&d=identicon&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/d7a825658be227f26b237e519f8541e05aabc9ff27b8eec4544a233a48c53be0?s=96&d=identicon&r=g","caption":"Bocon Technical Team"},"sameAs":["https:\/\/zjbocon.com\/","https:\/\/www.facebook.com\/profile.php?id=100088482339878","https:\/\/www.linkedin.com\/in\/\/hayley--968190269\/"],"url":"https:\/\/zjbocon.com\/?author=234312599"}]}},"jetpack_publicize_connections":[],"jetpack_featured_media_url":"https:\/\/zjbocon.com\/wp-content\/uploads\/2025\/09\/sterilizer-station-design-2.webp","uagb_featured_image_src":{"full":["https:\/\/zjbocon.com\/wp-content\/uploads\/2025\/09\/sterilizer-station-design-2.webp",800,400,false],"thumbnail":["https:\/\/zjbocon.com\/wp-content\/uploads\/2025\/09\/sterilizer-station-design-2-150x150.webp",150,150,true],"medium":["https:\/\/zjbocon.com\/wp-content\/uploads\/2025\/09\/sterilizer-station-design-2-300x150.webp",300,150,true],"medium_large":["https:\/\/zjbocon.com\/wp-content\/uploads\/2025\/09\/sterilizer-station-design-2-768x384.webp",768,384,true],"large":["https:\/\/zjbocon.com\/wp-content\/uploads\/2025\/09\/sterilizer-station-design-2.webp",800,400,false],"1536x1536":["https:\/\/zjbocon.com\/wp-content\/uploads\/2025\/09\/sterilizer-station-design-2.webp",800,400,false],"2048x2048":["https:\/\/zjbocon.com\/wp-content\/uploads\/2025\/09\/sterilizer-station-design-2.webp",800,400,false],"woocommerce_thumbnail":["https:\/\/zjbocon.com\/wp-content\/uploads\/2025\/09\/sterilizer-station-design-2-600x400.webp",600,400,true],"woocommerce_single":["https:\/\/zjbocon.com\/wp-content\/uploads\/2025\/09\/sterilizer-station-design-2-600x300.webp",600,300,true],"woocommerce_gallery_thumbnail":["https:\/\/zjbocon.com\/wp-content\/uploads\/2025\/09\/sterilizer-station-design-2-100x100.webp",100,100,true]},"uagb_author_info":{"display_name":"Bocon Technical Team","author_link":"https:\/\/zjbocon.com\/?author=234312599"},"uagb_comment_info":19,"uagb_excerpt":"Appearance Inspection: Check the main unit, control rack, and electrical control cabinet for any damage on the surface.","jetpack_likes_enabled":true,"jetpack_sharing_enabled":true,"jetpack_shortlink":"https:\/\/wp.me\/pgZDV6-Dl","jetpack-related-posts":[{"id":2880,"url":"https:\/\/zjbocon.com\/?p=2880","url_meta":{"origin":2439,"position":0},"title":"eto sterile machine manufacturer in china","author":"Bocon Technical Team","date":"2025-01-16","format":false,"excerpt":"Hangzhou Bocon Mechanical and Electrical Equipment Co., Ltd( eto sterile machine manufacturer in china) was established in 2006. The office is located in Hangzhou; And the factory is situated in Jiaxing. HZBOCON primarily engages in the research and development, production, and sales of eto sterile machine, the main advantage is\u2026","rel":"","context":"In &quot;Company News&quot;","block_context":{"text":"Company News","link":"https:\/\/zjbocon.com\/?cat=133125"},"img":{"alt_text":"","src":"https:\/\/i0.wp.com\/zjbocon.com\/wp-content\/uploads\/2025\/09\/cropped-cropped-hzbocon.png?resize=350%2C200&ssl=1","width":350,"height":200},"classes":[]},{"id":2013,"url":"https:\/\/zjbocon.com\/?p=2013","url_meta":{"origin":2439,"position":1},"title":"Purpose for eto sterilization validation","author":"Bocon Technical Team","date":"2024-10-28","format":false,"excerpt":"1.Purpose\u00a0for validation eto sterilization 1.1.the obtain of eto sterilization validation evidence that the equipment used for ETO sterilization has been provided and installed in accordance with its specification and can stably operate within predetermined limits and consistently performs in accordance with predetermined criteria and thereby yields product meeting its specification.\u2026","rel":"","context":"In &quot;ETO STERILIZER&quot;","block_context":{"text":"ETO STERILIZER","link":"https:\/\/zjbocon.com\/?cat=133124"},"img":{"alt_text":"eto sterilization validation","src":"https:\/\/i0.wp.com\/zjbocon.com\/wp-content\/uploads\/2024\/10\/Qualification_Services-2.webp?resize=350%2C200","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/zjbocon.com\/wp-content\/uploads\/2024\/10\/Qualification_Services-2.webp?resize=350%2C200 1x, https:\/\/i0.wp.com\/zjbocon.com\/wp-content\/uploads\/2024\/10\/Qualification_Services-2.webp?resize=525%2C300 1.5x, https:\/\/i0.wp.com\/zjbocon.com\/wp-content\/uploads\/2024\/10\/Qualification_Services-2.webp?resize=700%2C400 2x"},"classes":[]},{"id":2117,"url":"https:\/\/zjbocon.com\/?p=2117","url_meta":{"origin":2439,"position":2},"title":"Industry Eto Sterilizer Installation Verification","author":"Bocon Technical Team","date":"2024-11-06","format":false,"excerpt":"Industry Eto Sterilizer Installation Verification The installation of Industry Eto Sterilizer and all associated services should comply with the requirements of the construction and engineering drawings. It is recommended to verify the components of the Industry Eto Sterilizer to ensure the installation meets applicable standards and requirements. These equipment components\u2026","rel":"","context":"In &quot;ETO STERILIZER&quot;","block_context":{"text":"ETO STERILIZER","link":"https:\/\/zjbocon.com\/?cat=133124"},"img":{"alt_text":"","src":"https:\/\/i0.wp.com\/zjbocon.com\/wp-content\/uploads\/2024\/10\/sterilizer-station-design-2.webp?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/zjbocon.com\/wp-content\/uploads\/2024\/10\/sterilizer-station-design-2.webp?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/zjbocon.com\/wp-content\/uploads\/2024\/10\/sterilizer-station-design-2.webp?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/zjbocon.com\/wp-content\/uploads\/2024\/10\/sterilizer-station-design-2.webp?resize=700%2C400&ssl=1 2x"},"classes":[]},{"id":8772,"url":"https:\/\/zjbocon.com\/?p=8772","url_meta":{"origin":2439,"position":3},"title":"ETO STERILIZATION Safety Guidelines: Best Practices for Using Ethylene Oxide as a Sterilant","author":"Bocon Technical Team","date":"2025-11-25","format":false,"excerpt":"Ethylene oxide (ETO STERILIZATION) is widely used as a low-temperature sterilant in industries like healthcare, pharmaceuticals, and biotechnology. However, due to its toxic, flammable, and potentially carcinogenic properties, it's critical to follow strict safety protocols. This article outlines the essential safety guidelines for safely operating ETO STERILIZATION systems. 1. Regulatory\u2026","rel":"","context":"In &quot;Company News&quot;","block_context":{"text":"Company News","link":"https:\/\/zjbocon.com\/?cat=133125"},"img":{"alt_text":"","src":"https:\/\/i0.wp.com\/zjbocon.com\/wp-content\/uploads\/2025\/11\/eto-sterilzer-scaled.webp?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/zjbocon.com\/wp-content\/uploads\/2025\/11\/eto-sterilzer-scaled.webp?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/zjbocon.com\/wp-content\/uploads\/2025\/11\/eto-sterilzer-scaled.webp?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/zjbocon.com\/wp-content\/uploads\/2025\/11\/eto-sterilzer-scaled.webp?resize=700%2C400&ssl=1 2x, https:\/\/i0.wp.com\/zjbocon.com\/wp-content\/uploads\/2025\/11\/eto-sterilzer-scaled.webp?resize=1050%2C600&ssl=1 3x, https:\/\/i0.wp.com\/zjbocon.com\/wp-content\/uploads\/2025\/11\/eto-sterilzer-scaled.webp?resize=1400%2C800&ssl=1 4x"},"classes":[]},{"id":8776,"url":"https:\/\/zjbocon.com\/?p=8776","url_meta":{"origin":2439,"position":4},"title":"How to Test ETO Gas Sterilization Test Materials","author":"Bocon Technical Team","date":"2025-11-25","format":false,"excerpt":"When it comes to ETO gas sterilization, testing is an essential part of ensuring the effectiveness and safety of the sterilization process. ETO GAS STERILIZATION TEST MATERIALS","rel":"","context":"In &quot;Company News&quot;","block_context":{"text":"Company News","link":"https:\/\/zjbocon.com\/?cat=133125"},"img":{"alt_text":"","src":"https:\/\/i0.wp.com\/zjbocon.com\/wp-content\/uploads\/2025\/09\/ethylene-oxide-sterilization-68.webp?resize=350%2C200&ssl=1","width":350,"height":200},"classes":[]},{"id":8843,"url":"https:\/\/zjbocon.com\/?p=8843","url_meta":{"origin":2439,"position":5},"title":"Ethylene Oxide (EtO) Emissions Control: Technologies and Solutions","author":"Bocon Technical Team","date":"2025-12-03","format":false,"excerpt":"Effective EtO emissions control is essential for sterilization, chemical manufacturing, and industrial operations handling ethylene oxide (EtO). Modern abatement technologies help facilities meet regulatory requirements, improve safety, and minimize environmental impact. This guide provides an optimized, SEO-ready overview of primary EtO control technologies, including wet scrubbers, thermal oxidizers, dry bed\u2026","rel":"","context":"In &quot;Company News&quot;","block_context":{"text":"Company News","link":"https:\/\/zjbocon.com\/?cat=133125"},"img":{"alt_text":"","src":"https:\/\/i0.wp.com\/zjbocon.com\/wp-content\/uploads\/2025\/09\/eo-gas-scrubber-1.webp?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/zjbocon.com\/wp-content\/uploads\/2025\/09\/eo-gas-scrubber-1.webp?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/zjbocon.com\/wp-content\/uploads\/2025\/09\/eo-gas-scrubber-1.webp?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/zjbocon.com\/wp-content\/uploads\/2025\/09\/eo-gas-scrubber-1.webp?resize=700%2C400&ssl=1 2x, https:\/\/i0.wp.com\/zjbocon.com\/wp-content\/uploads\/2025\/09\/eo-gas-scrubber-1.webp?resize=1050%2C600&ssl=1 3x"},"classes":[]}],"_links":{"self":[{"href":"https:\/\/zjbocon.com\/index.php?rest_route=\/wp\/v2\/posts\/2439","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/zjbocon.com\/index.php?rest_route=\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/zjbocon.com\/index.php?rest_route=\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/zjbocon.com\/index.php?rest_route=\/wp\/v2\/users\/234312599"}],"replies":[{"embeddable":true,"href":"https:\/\/zjbocon.com\/index.php?rest_route=%2Fwp%2Fv2%2Fcomments&post=2439"}],"version-history":[{"count":4,"href":"https:\/\/zjbocon.com\/index.php?rest_route=\/wp\/v2\/posts\/2439\/revisions"}],"predecessor-version":[{"id":8865,"href":"https:\/\/zjbocon.com\/index.php?rest_route=\/wp\/v2\/posts\/2439\/revisions\/8865"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/zjbocon.com\/index.php?rest_route=\/wp\/v2\/media\/8346"}],"wp:attachment":[{"href":"https:\/\/zjbocon.com\/index.php?rest_route=%2Fwp%2Fv2%2Fmedia&parent=2439"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/zjbocon.com\/index.php?rest_route=%2Fwp%2Fv2%2Fcategories&post=2439"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/zjbocon.com\/index.php?rest_route=%2Fwp%2Fv2%2Ftags&post=2439"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}