{"id":2420,"date":"2024-12-17T10:31:42","date_gmt":"2024-12-17T02:31:42","guid":{"rendered":"https:\/\/zjbocon.com\/?p=2420"},"modified":"2025-12-05T10:21:30","modified_gmt":"2025-12-05T02:21:30","slug":"maintenance-guide-for-eto-sterilizers","status":"publish","type":"post","link":"https:\/\/zjbocon.com\/maintenance-guide-for-eto-sterilizers\/","title":{"rendered":"Maintenance Guide for ETO Sterilizers"},"content":{"rendered":"\n<div class=\"wp-block-uagb-image uagb-block-48bf8c89 wp-block-uagb-image--layout-default wp-block-uagb-image--effect-static wp-block-uagb-image--align-none\"><figure class=\"wp-block-uagb-image__figure\"><img loading=\"lazy\" decoding=\"async\" src=\"https:\/\/zjbocon.com\/wp-content\/uploads\/2025\/09\/eto-sterilizer-7-1024x1024.webp\" alt=\"\" class=\"uag-image-8479\" width=\"1024\" height=\"1024\" title=\"eto-sterilizer-7\" role=\"img\" \><\/figure><\/div>\n\n\n\n<p class=\"wp-block-paragraph\">9.1 ETO sterilizasyonu sırasında, operatörlerin çalışma alanından ayrılmasına izin verilmez ve sürekli olarak ETO sterilizasyon sürecini gözlemlemelidir. Herhangi bir anormal fenomen meydana gelirse, makine hemen kapatılmalı ve güç kaynağı muayene için kesilmelidir.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">9.2 Isıtma sistemindeki sirkülasyon suyunu her üç ayda bir değiştirin. Suyu değiştirirken öncelikle haznenin alt kısmında ve kapının alt kısmında bulunan tüm su tahliye anahtarlarını açarak suyun tamamen boşaltılmasını sağlayın. Boruları ve su tankını temiz suyla duruladıktan sonra, dolaşan yeni suyla yeniden doldurun.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">9.3 Hava, ısıtma, buharlaştırma ve etilen oksit sistemi filtrelerini en az her 30 ETO Sterilizasyon döngüsünden sonra inceleyin ve temizleyin; hasarlı veya arızalı filtreleri değiştirin. (Temizlik ortamları su, basınçlı hava veya buhar içerebilir.)<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">9.4 Vakumlu basınç göstergeleri, basınç sensörleri ve diğer ölçüm cihazları, ulusal metroloji yasalarına göre her altı ayda bir yerel metroloji departmanı tarafından kalibre edilmelidir.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">9.5 Sızdırmazlık contaları altı ayda bir değiştirilmelidir.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">9.6 Elektrik kontrol sistemindeki tüm terminal bağlantılarının sağlam olduğunu düzenli olarak kontrol edin.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">9.7 Günde en az bir kez sirkülasyon suyu, vakum, etilen oksit, buhar ve buharlaştırma cihazı boru hatlarında sızıntı olup olmadığını kontrol edin. Herhangi bir sızıntı bulunursa, bunların güvenli bir şekilde giderilmesi için önlemler alınmalıdır.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">9.8 Kapı menteşelerini haftada bir kez yağlayın ve iç duvarlarda veya menteşelerde kir birikmemesini sağlamak için iç duvarları, kapı çerçevesini ve menteşeleri temizleyin.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">9.9 Ekipman etrafındaki ortam sıcaklığı sıfır santigrat derecenin altına düşerse ve ekipman sürekli çalışamaz hale gelirse, ısıtma sistemi üç saatten fazla ısıtmayı durdurduysa sistemin donmasını ve çatlamasını önlemek için sirkülasyon sistemindeki su boşaltılmalıdır. .<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"h-if-you-want-to-know-more-about-ethylene-oxide-sterilization\">Etilen Oksit Sterilizasyonu Hakkında Daha Fazla Bilgi Almak İstiyorsanız<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Telefon:<a href=\"https:\/\/wa.me\/8619975258603\">+8619975258603<\/a><\/p>\n\n\n\n<p class=\"wp-block-paragraph\">E-posta:<a href=\"mailto:hayley@hzbocon.com\">hayley@hzbocon.com<\/a><\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Yerel Site: Oda 1202, Caitong Zhongxin, Xiasha Bölgesi, Hangzhou Şehri, Zhejiang Eyaleti, Çin<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Web sitesi:<a href=\"https:\/\/www.hzbocon.com\/\">hzbocon.com<\/a><a href=\"https:\/\/zjbocon.com\/\">&nbsp;zjbocon.com<\/a><\/p>\n","protected":false},"excerpt":{"rendered":"<p>9.1 ETO sterilizasyonu sırasında, operatörlerin çalışma alanından ayrılmasına izin verilmez ve sürekli olarak ETO sterilizasyon sürecini gözlemlemelidir. Herhangi bir anormal fenomen meydana gelirse, makine hemen kapatılmalı ve güç kaynağı muayene için kesilmelidir.<\/p>\n","protected":false},"author":234312599,"featured_media":8485,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_uag_custom_page_level_css":"","site-sidebar-layout":"default","site-content-layout":"","ast-site-content-layout":"default","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","ast-disable-related-posts":"","theme-transparent-header-meta":"","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"set","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"_jetpack_newsletter_access":"","_jetpack_dont_email_post_to_subs":false,"_jetpack_newsletter_tier_id":0,"_jetpack_memberships_contains_paywalled_content":false,"_jetpack_feature_clip_id":0,"_jetpack_memberships_contains_paid_content":false,"footnotes":"","jetpack_publicize_message":"","jetpack_publicize_feature_enabled":true,"jetpack_social_post_already_shared":true,"jetpack_social_options":{"image_generator_settings":{"template":"highway","enabled":false},"version":2},"jetpack_post_was_ever_published":false},"categories":[133124],"tags":[],"class_list":["post-2420","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-eto-sterilizer"],"yoast_head":"<!-- This site is optimized with the Yoast SEO Premium plugin v27.2 (Yoast SEO v28.0) - https:\/\/yoast.com\/product\/yoast-seo-premium-wordpress\/ -->\n<title>ETO Sterilizatörleri için Bakım Kılavuzu - ETO STERİLİZATÖR<\/title>\n<meta name=\"description\" content=\"During sterilization, operators are not allowed to leave the operating area and must continuously observe eto sterilization process.\" \>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \>\n<link rel=\"canonical\" href=\"https:\/\/zjbocon.com\/maintenance-guide-for-eto-sterilizers\/\" \>\n<meta property=\"og:locale\" content=\"tr_TR\" \>\n<meta property=\"og:type\" content=\"article\" \>\n<meta property=\"og:title\" content=\"Maintenance Guide for ETO Sterilizers\" \>\n<meta property=\"og:description\" content=\"During sterilization, operators are not allowed to leave the operating area and must continuously observe eto sterilization process.\" \>\n<meta property=\"og:url\" content=\"https:\/\/zjbocon.com\/maintenance-guide-for-eto-sterilizers\/\" \>\n<meta property=\"og:site_name\" content=\"ETO STERILIZER\" \>\n<meta property=\"article:publisher\" content=\"https:\/\/www.facebook.com\/profile.php?id=100088482339878\" \>\n<meta property=\"article:author\" content=\"https:\/\/www.facebook.com\/profile.php?id=100088482339878\" \>\n<meta property=\"article:published_time\" content=\"2024-12-17T02:31:42+00:00\" \>\n<meta property=\"article:modified_time\" content=\"2025-12-05T02:21:30+00:00\" \>\n<meta property=\"og:image\" content=\"https:\/\/zjbocon.com\/wp-content\/uploads\/2025\/09\/eto-sterilizer-4.webp\" \>\n\t<meta property=\"og:image:width\" content=\"1200\" \>\n\t<meta property=\"og:image:height\" content=\"1200\" \>\n\t<meta property=\"og:image:type\" content=\"image\/webp\" \>\n<meta name=\"author\" content=\"Bocon Technical Team\" \>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \>\n<meta name=\"twitter:creator\" content=\"@BoconAnd\" \>\n<meta name=\"twitter:site\" content=\"@BoconAnd\" \>\n<meta name=\"twitter:label1\" content=\"Written by\" \>\n\t<meta name=\"twitter:data1\" content=\"Bocon Technical Team\" \>\n\t<meta name=\"twitter:label2\" content=\"Est. reading time\" \>\n\t<meta name=\"twitter:data2\" content=\"2 minutes\" \>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\\\/\\\/zjbocon.com\\\/maintenance-guide-for-eto-sterilizers\\\/#article\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/zjbocon.com\\\/maintenance-guide-for-eto-sterilizers\\\/\"},\"author\":{\"name\":\"Bocon Technical Team\",\"@id\":\"https:\\\/\\\/zjbocon.com\\\/#\\\/schema\\\/person\\\/f12be028b8ae9843a4396dcc8012b425\"},\"headline\":\"Maintenance Guide for ETO Sterilizers\",\"datePublished\":\"2024-12-17T02:31:42+00:00\",\"dateModified\":\"2025-12-05T02:21:30+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/zjbocon.com\\\/maintenance-guide-for-eto-sterilizers\\\/\"},\"wordCount\":323,\"commentCount\":0,\"publisher\":{\"@id\":\"https:\\\/\\\/zjbocon.com\\\/#organization\"},\"image\":{\"@id\":\"https:\\\/\\\/zjbocon.com\\\/maintenance-guide-for-eto-sterilizers\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/zjbocon.com\\\/wp-content\\\/uploads\\\/2025\\\/09\\\/eto-sterilizer-4.webp\",\"articleSection\":[\"ETO STERILIZER\"],\"inLanguage\":\"tr-TR\",\"potentialAction\":[{\"@type\":\"CommentAction\",\"name\":\"Comment\",\"target\":[\"https:\\\/\\\/zjbocon.com\\\/maintenance-guide-for-eto-sterilizers\\\/#respond\"]}]},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/zjbocon.com\\\/maintenance-guide-for-eto-sterilizers\\\/\",\"url\":\"https:\\\/\\\/zjbocon.com\\\/maintenance-guide-for-eto-sterilizers\\\/\",\"name\":\"Maintenance Guide for ETO Sterilizers - ETO STERILIZER\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/zjbocon.com\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/zjbocon.com\\\/maintenance-guide-for-eto-sterilizers\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/zjbocon.com\\\/maintenance-guide-for-eto-sterilizers\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/zjbocon.com\\\/wp-content\\\/uploads\\\/2025\\\/09\\\/eto-sterilizer-4.webp\",\"datePublished\":\"2024-12-17T02:31:42+00:00\",\"dateModified\":\"2025-12-05T02:21:30+00:00\",\"description\":\"During sterilization, operators are not allowed to leave the operating area and must continuously observe the eto sterilization process.\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/zjbocon.com\\\/maintenance-guide-for-eto-sterilizers\\\/#breadcrumb\"},\"inLanguage\":\"tr-TR\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/zjbocon.com\\\/maintenance-guide-for-eto-sterilizers\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"tr-TR\",\"@id\":\"https:\\\/\\\/zjbocon.com\\\/maintenance-guide-for-eto-sterilizers\\\/#primaryimage\",\"url\":\"https:\\\/\\\/zjbocon.com\\\/wp-content\\\/uploads\\\/2025\\\/09\\\/eto-sterilizer-4.webp\",\"contentUrl\":\"https:\\\/\\\/zjbocon.com\\\/wp-content\\\/uploads\\\/2025\\\/09\\\/eto-sterilizer-4.webp\",\"width\":1200,\"height\":1200,\"caption\":\"ETO STERILIZER-HZBOCON\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/zjbocon.com\\\/maintenance-guide-for-eto-sterilizers\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/zjbocon.com\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Maintenance Guide for ETO Sterilizers\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/zjbocon.com\\\/#website\",\"url\":\"https:\\\/\\\/zjbocon.com\\\/\",\"name\":\"ETO STERILIZER\",\"description\":\"One-stop Solution Supplier of Ethylene Oxide Sterilization\",\"publisher\":{\"@id\":\"https:\\\/\\\/zjbocon.com\\\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/zjbocon.com\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"tr-TR\"},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/zjbocon.com\\\/#organization\",\"name\":\"ETO STERILIZER\",\"url\":\"https:\\\/\\\/zjbocon.com\\\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"tr-TR\",\"@id\":\"https:\\\/\\\/zjbocon.com\\\/#\\\/schema\\\/logo\\\/image\\\/\",\"url\":\"https:\\\/\\\/zjbocon.com\\\/wp-content\\\/uploads\\\/2024\\\/10\\\/logo-1.webp\",\"contentUrl\":\"https:\\\/\\\/zjbocon.com\\\/wp-content\\\/uploads\\\/2024\\\/10\\\/logo-1.webp\",\"width\":180,\"height\":60,\"caption\":\"ETO STERILIZER\"},\"image\":{\"@id\":\"https:\\\/\\\/zjbocon.com\\\/#\\\/schema\\\/logo\\\/image\\\/\"},\"sameAs\":[\"https:\\\/\\\/www.facebook.com\\\/profile.php?id=100088482339878\",\"https:\\\/\\\/x.com\\\/BoconAnd\",\"https:\\\/\\\/www.linkedin.com\\\/in\\\/--06a221139\\\/\"]},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/zjbocon.com\\\/#\\\/schema\\\/person\\\/f12be028b8ae9843a4396dcc8012b425\",\"name\":\"Bocon Technical Team\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"tr-TR\",\"@id\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/d7a825658be227f26b237e519f8541e05aabc9ff27b8eec4544a233a48c53be0?s=96&d=identicon&r=g\",\"url\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/d7a825658be227f26b237e519f8541e05aabc9ff27b8eec4544a233a48c53be0?s=96&d=identicon&r=g\",\"contentUrl\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/d7a825658be227f26b237e519f8541e05aabc9ff27b8eec4544a233a48c53be0?s=96&d=identicon&r=g\",\"caption\":\"Bocon Technical Team\"},\"sameAs\":[\"https:\\\/\\\/zjbocon.com\\\/\",\"https:\\\/\\\/www.facebook.com\\\/profile.php?id=100088482339878\",\"https:\\\/\\\/www.linkedin.com\\\/in\\\/\\\/hayley--968190269\\\/\"],\"url\":\"https:\\\/\\\/zjbocon.com\\\/author\\\/15657615935a\\\/\"}]}<\/script>\n<!-- \/ Yoast SEO Premium plugin. -->","yoast_head_json":{"title":"Maintenance Guide for ETO Sterilizers - ETO STERILIZER","description":"During sterilization, operators are not allowed to leave the operating area and must continuously observe the eto sterilization process.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/zjbocon.com\/maintenance-guide-for-eto-sterilizers\/","og_locale":"tr_TR","og_type":"article","og_title":"Maintenance Guide for ETO Sterilizers","og_description":"During sterilization, operators are not allowed to leave the operating area and must continuously observe the eto sterilization process.","og_url":"https:\/\/zjbocon.com\/maintenance-guide-for-eto-sterilizers\/","og_site_name":"ETO STERILIZER","article_publisher":"https:\/\/www.facebook.com\/profile.php?id=100088482339878","article_author":"https:\/\/www.facebook.com\/profile.php?id=100088482339878","article_published_time":"2024-12-17T02:31:42+00:00","article_modified_time":"2025-12-05T02:21:30+00:00","og_image":[{"width":1200,"height":1200,"url":"https:\/\/zjbocon.com\/wp-content\/uploads\/2025\/09\/eto-sterilizer-4.webp","type":"image\/webp"}],"author":"Bocon Technical Team","twitter_card":"summary_large_image","twitter_creator":"@BoconAnd","twitter_site":"@BoconAnd","twitter_misc":{"Written by":"Bocon Technical Team","Est. reading time":"2 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/zjbocon.com\/maintenance-guide-for-eto-sterilizers\/#article","isPartOf":{"@id":"https:\/\/zjbocon.com\/maintenance-guide-for-eto-sterilizers\/"},"author":{"name":"Bocon Technical Team","@id":"https:\/\/zjbocon.com\/#\/schema\/person\/f12be028b8ae9843a4396dcc8012b425"},"headline":"Maintenance Guide for ETO Sterilizers","datePublished":"2024-12-17T02:31:42+00:00","dateModified":"2025-12-05T02:21:30+00:00","mainEntityOfPage":{"@id":"https:\/\/zjbocon.com\/maintenance-guide-for-eto-sterilizers\/"},"wordCount":323,"commentCount":0,"publisher":{"@id":"https:\/\/zjbocon.com\/#organization"},"image":{"@id":"https:\/\/zjbocon.com\/maintenance-guide-for-eto-sterilizers\/#primaryimage"},"thumbnailUrl":"https:\/\/zjbocon.com\/wp-content\/uploads\/2025\/09\/eto-sterilizer-4.webp","articleSection":["ETO STERILIZER"],"inLanguage":"tr-TR","potentialAction":[{"@type":"CommentAction","name":"Comment","target":["https:\/\/zjbocon.com\/maintenance-guide-for-eto-sterilizers\/#respond"]}]},{"@type":"WebPage","@id":"https:\/\/zjbocon.com\/maintenance-guide-for-eto-sterilizers\/","url":"https:\/\/zjbocon.com\/maintenance-guide-for-eto-sterilizers\/","name":"Maintenance Guide for ETO Sterilizers - ETO STERILIZER","isPartOf":{"@id":"https:\/\/zjbocon.com\/#website"},"primaryImageOfPage":{"@id":"https:\/\/zjbocon.com\/maintenance-guide-for-eto-sterilizers\/#primaryimage"},"image":{"@id":"https:\/\/zjbocon.com\/maintenance-guide-for-eto-sterilizers\/#primaryimage"},"thumbnailUrl":"https:\/\/zjbocon.com\/wp-content\/uploads\/2025\/09\/eto-sterilizer-4.webp","datePublished":"2024-12-17T02:31:42+00:00","dateModified":"2025-12-05T02:21:30+00:00","description":"During sterilization, operators are not allowed to leave the operating area and must continuously observe the eto sterilization process.","breadcrumb":{"@id":"https:\/\/zjbocon.com\/maintenance-guide-for-eto-sterilizers\/#breadcrumb"},"inLanguage":"tr-TR","potentialAction":[{"@type":"ReadAction","target":["https:\/\/zjbocon.com\/maintenance-guide-for-eto-sterilizers\/"]}]},{"@type":"ImageObject","inLanguage":"tr-TR","@id":"https:\/\/zjbocon.com\/maintenance-guide-for-eto-sterilizers\/#primaryimage","url":"https:\/\/zjbocon.com\/wp-content\/uploads\/2025\/09\/eto-sterilizer-4.webp","contentUrl":"https:\/\/zjbocon.com\/wp-content\/uploads\/2025\/09\/eto-sterilizer-4.webp","width":1200,"height":1200,"caption":"ETO STERILIZER-HZBOCON"},{"@type":"BreadcrumbList","@id":"https:\/\/zjbocon.com\/maintenance-guide-for-eto-sterilizers\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/zjbocon.com\/"},{"@type":"ListItem","position":2,"name":"Maintenance Guide for ETO Sterilizers"}]},{"@type":"WebSite","@id":"https:\/\/zjbocon.com\/#website","url":"https:\/\/zjbocon.com\/","name":"ETO STERILIZER","description":"One-stop Solution Supplier of Ethylene Oxide Sterilization","publisher":{"@id":"https:\/\/zjbocon.com\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/zjbocon.com\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"tr-TR"},{"@type":"Organization","@id":"https:\/\/zjbocon.com\/#organization","name":"ETO STERILIZER","url":"https:\/\/zjbocon.com\/","logo":{"@type":"ImageObject","inLanguage":"tr-TR","@id":"https:\/\/zjbocon.com\/#\/schema\/logo\/image\/","url":"https:\/\/zjbocon.com\/wp-content\/uploads\/2024\/10\/logo-1.webp","contentUrl":"https:\/\/zjbocon.com\/wp-content\/uploads\/2024\/10\/logo-1.webp","width":180,"height":60,"caption":"ETO STERILIZER"},"image":{"@id":"https:\/\/zjbocon.com\/#\/schema\/logo\/image\/"},"sameAs":["https:\/\/www.facebook.com\/profile.php?id=100088482339878","https:\/\/x.com\/BoconAnd","https:\/\/www.linkedin.com\/in\/--06a221139\/"]},{"@type":"Person","@id":"https:\/\/zjbocon.com\/#\/schema\/person\/f12be028b8ae9843a4396dcc8012b425","name":"Bocon Technical Team","image":{"@type":"ImageObject","inLanguage":"tr-TR","@id":"https:\/\/secure.gravatar.com\/avatar\/d7a825658be227f26b237e519f8541e05aabc9ff27b8eec4544a233a48c53be0?s=96&d=identicon&r=g","url":"https:\/\/secure.gravatar.com\/avatar\/d7a825658be227f26b237e519f8541e05aabc9ff27b8eec4544a233a48c53be0?s=96&d=identicon&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/d7a825658be227f26b237e519f8541e05aabc9ff27b8eec4544a233a48c53be0?s=96&d=identicon&r=g","caption":"Bocon Technical Team"},"sameAs":["https:\/\/zjbocon.com\/","https:\/\/www.facebook.com\/profile.php?id=100088482339878","https:\/\/www.linkedin.com\/in\/\/hayley--968190269\/"],"url":"https:\/\/zjbocon.com\/author\/15657615935a\/"}]}},"jetpack_publicize_connections":[],"jetpack_featured_media_url":"https:\/\/zjbocon.com\/wp-content\/uploads\/2025\/09\/eto-sterilizer-4.webp","uagb_featured_image_src":{"full":["https:\/\/zjbocon.com\/wp-content\/uploads\/2025\/09\/eto-sterilizer-4.webp",1200,1200,false],"thumbnail":["https:\/\/zjbocon.com\/wp-content\/uploads\/2025\/09\/eto-sterilizer-4-150x150.webp",150,150,true],"medium":["https:\/\/zjbocon.com\/wp-content\/uploads\/2025\/09\/eto-sterilizer-4-300x300.webp",300,300,true],"medium_large":["https:\/\/zjbocon.com\/wp-content\/uploads\/2025\/09\/eto-sterilizer-4-768x768.webp",768,768,true],"large":["https:\/\/zjbocon.com\/wp-content\/uploads\/2025\/09\/eto-sterilizer-4-1024x1024.webp",1024,1024,true],"1536x1536":["https:\/\/zjbocon.com\/wp-content\/uploads\/2025\/09\/eto-sterilizer-4.webp",1200,1200,false],"2048x2048":["https:\/\/zjbocon.com\/wp-content\/uploads\/2025\/09\/eto-sterilizer-4.webp",1200,1200,false],"woocommerce_thumbnail":["https:\/\/zjbocon.com\/wp-content\/uploads\/2025\/09\/eto-sterilizer-4-600x600.webp",600,600,true],"woocommerce_single":["https:\/\/zjbocon.com\/wp-content\/uploads\/2025\/09\/eto-sterilizer-4-600x600.webp",600,600,true],"woocommerce_gallery_thumbnail":["https:\/\/zjbocon.com\/wp-content\/uploads\/2025\/09\/eto-sterilizer-4-100x100.webp",100,100,true]},"uagb_author_info":{"display_name":"Bocon Technical Team","author_link":"https:\/\/zjbocon.com\/author\/15657615935a\/"},"uagb_comment_info":28,"uagb_excerpt":"9.1 During ETO Sterilization, operators are not allowed to leave the operating area and must continuously observe the ETO Sterilization process. If any abnormal phenomena occur, the machine must be immediately shut down, and the power supply should be cut off for inspection.","jetpack_likes_enabled":true,"jetpack_sharing_enabled":true,"jetpack_shortlink":"https:\/\/wp.me\/pgZDV6-D2","jetpack-related-posts":[{"id":8772,"url":"https:\/\/zjbocon.com\/eto-sterilization-safety-guidelines-best-practices-for-using-ethylene-oxide-as-a-sterilant\/","url_meta":{"origin":2420,"position":0},"title":"ETO STERILIZATION Safety Guidelines: Best Practices for Using Ethylene Oxide as a Sterilant","author":"Bocon Technical Team","date":"2025-11-25","format":false,"excerpt":"Ethylene oxide (ETO STERILIZATION) is widely used as a low-temperature sterilant in industries like healthcare, pharmaceuticals, and biotechnology. However, due to its toxic, flammable, and potentially carcinogenic properties, it's critical to follow strict safety protocols. This article outlines the essential safety guidelines for safely operating ETO STERILIZATION systems. 1. Regulatory\u2026","rel":"","context":"In &quot;Company News&quot;","block_context":{"text":"Company News","link":"https:\/\/zjbocon.com\/category\/company-news\/"},"img":{"alt_text":"","src":"https:\/\/i0.wp.com\/zjbocon.com\/wp-content\/uploads\/2025\/11\/eto-sterilzer-scaled.webp?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/zjbocon.com\/wp-content\/uploads\/2025\/11\/eto-sterilzer-scaled.webp?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/zjbocon.com\/wp-content\/uploads\/2025\/11\/eto-sterilzer-scaled.webp?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/zjbocon.com\/wp-content\/uploads\/2025\/11\/eto-sterilzer-scaled.webp?resize=700%2C400&ssl=1 2x, https:\/\/i0.wp.com\/zjbocon.com\/wp-content\/uploads\/2025\/11\/eto-sterilzer-scaled.webp?resize=1050%2C600&ssl=1 3x, https:\/\/i0.wp.com\/zjbocon.com\/wp-content\/uploads\/2025\/11\/eto-sterilzer-scaled.webp?resize=1400%2C800&ssl=1 4x"},"classes":[]},{"id":1950,"url":"https:\/\/zjbocon.com\/eto-sterilization-process\/","url_meta":{"origin":2420,"position":1},"title":"eto sterilization process","author":"Bocon Technical Team","date":"2024-10-23","format":false,"excerpt":"Eto Sterilization is conducted using a eto sterilizer located in a dedicated facility.","rel":"","context":"In &quot;ETO STERILIZER&quot;","block_context":{"text":"ETO STERILIZER","link":"https:\/\/zjbocon.com\/category\/eto-sterilizer\/"},"img":{"alt_text":"eto sterilization process","src":"https:\/\/i0.wp.com\/zjbocon.com\/wp-content\/uploads\/2024\/10\/eto-sterilization-process-e1729654271899.webp?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/zjbocon.com\/wp-content\/uploads\/2024\/10\/eto-sterilization-process-e1729654271899.webp?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/zjbocon.com\/wp-content\/uploads\/2024\/10\/eto-sterilization-process-e1729654271899.webp?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/zjbocon.com\/wp-content\/uploads\/2024\/10\/eto-sterilization-process-e1729654271899.webp?resize=700%2C400&ssl=1 2x"},"classes":[]},{"id":8776,"url":"https:\/\/zjbocon.com\/how-to-test-eto-gas-sterilization-test-materials\/","url_meta":{"origin":2420,"position":2},"title":"How to Test ETO Gas Sterilization Test Materials","author":"Bocon Technical Team","date":"2025-11-25","format":false,"excerpt":"When it comes to ETO gas sterilization, testing is an essential part of ensuring the effectiveness and safety of the sterilization process. ETO GAS STERILIZATION TEST MATERIALS","rel":"","context":"In &quot;Company News&quot;","block_context":{"text":"Company News","link":"https:\/\/zjbocon.com\/category\/company-news\/"},"img":{"alt_text":"","src":"https:\/\/i0.wp.com\/zjbocon.com\/wp-content\/uploads\/2025\/09\/ethylene-oxide-sterilization-68.webp?resize=350%2C200&ssl=1","width":350,"height":200},"classes":[]},{"id":9276,"url":"https:\/\/zjbocon.com\/9276-2\/","url_meta":{"origin":2420,"position":3},"title":"Sterilization Compatibility of Sterile Barrier Systems","author":"Bocon Technical Team","date":"2026-02-06","format":false,"excerpt":"Sterilization Compatibility of Sterile Barrier Systems Technical White Paper 1. Introduction The compatibility between sterile barrier systems (SBS) and sterilization processes is a critical engineering consideration in medical device packaging design. Inappropriate material-process combinations may lead to insufficient sterilant penetration, material degradation, or loss of microbial barrier integrity. This technical\u2026","rel":"","context":"In &quot;ETO STERILIZER&quot;","block_context":{"text":"ETO STERILIZER","link":"https:\/\/zjbocon.com\/category\/eto-sterilizer\/"},"img":{"alt_text":"","src":"https:\/\/i0.wp.com\/zjbocon.com\/wp-content\/uploads\/2024\/11\/eto-sterilizer-hzbocon-5.png?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/zjbocon.com\/wp-content\/uploads\/2024\/11\/eto-sterilizer-hzbocon-5.png?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/zjbocon.com\/wp-content\/uploads\/2024\/11\/eto-sterilizer-hzbocon-5.png?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/zjbocon.com\/wp-content\/uploads\/2024\/11\/eto-sterilizer-hzbocon-5.png?resize=700%2C400&ssl=1 2x, https:\/\/i0.wp.com\/zjbocon.com\/wp-content\/uploads\/2024\/11\/eto-sterilizer-hzbocon-5.png?resize=1050%2C600&ssl=1 3x"},"classes":[]},{"id":8958,"url":"https:\/\/zjbocon.com\/understanding-what-is-eto-sterilizers-a-comprehensive-guide\/","url_meta":{"origin":2420,"position":4},"title":"Understanding What is ETO Sterilizers: A Comprehensive Guide","author":"Bocon Technical Team","date":"2025-12-16","format":false,"excerpt":"Discover the essentials of ETO sterilizers and ethylene oxide sterilization, ensuring the highest hygiene standards in healthcare and beyond.","rel":"","context":"In &quot;Company News&quot;","block_context":{"text":"Company News","link":"https:\/\/zjbocon.com\/category\/company-news\/"},"img":{"alt_text":"","src":"https:\/\/i0.wp.com\/zjbocon.com\/wp-content\/uploads\/2024\/11\/eto-sterilizer-hzbocon-3.png?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/zjbocon.com\/wp-content\/uploads\/2024\/11\/eto-sterilizer-hzbocon-3.png?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/zjbocon.com\/wp-content\/uploads\/2024\/11\/eto-sterilizer-hzbocon-3.png?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/zjbocon.com\/wp-content\/uploads\/2024\/11\/eto-sterilizer-hzbocon-3.png?resize=700%2C400&ssl=1 2x, https:\/\/i0.wp.com\/zjbocon.com\/wp-content\/uploads\/2024\/11\/eto-sterilizer-hzbocon-3.png?resize=1050%2C600&ssl=1 3x"},"classes":[]},{"id":2004,"url":"https:\/\/zjbocon.com\/the-guide-to-ethylene-oxide-in-sterilization\/","url_meta":{"origin":2420,"position":5},"title":"The Guide to ethylene oxide in sterilization","author":"Bocon Technical Team","date":"2024-10-28","format":false,"excerpt":"ethylene oxide in sterilization Introduction ETO is a colorless gas that is flammable and explosive. The four essential parameters (operational ranges) of ethylene oxide in sterilization are: gas concentration (450 to 1200 mg\/l); temperature (37 to 63\u00b0C); relative humidity (40 to 80%)(water molecules carry ETO to reactive sites); and exposure\u2026","rel":"","context":"In &quot;ETO STERILIZER&quot;","block_context":{"text":"ETO STERILIZER","link":"https:\/\/zjbocon.com\/category\/eto-sterilizer\/"},"img":{"alt_text":"Industry_ETO_Sterilizer","src":"https:\/\/i0.wp.com\/zjbocon.com\/wp-content\/uploads\/2024\/10\/Industry_ETO_Sterilizer.webp?resize=350%2C200","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/zjbocon.com\/wp-content\/uploads\/2024\/10\/Industry_ETO_Sterilizer.webp?resize=350%2C200 1x, https:\/\/i0.wp.com\/zjbocon.com\/wp-content\/uploads\/2024\/10\/Industry_ETO_Sterilizer.webp?resize=525%2C300 1.5x, https:\/\/i0.wp.com\/zjbocon.com\/wp-content\/uploads\/2024\/10\/Industry_ETO_Sterilizer.webp?resize=700%2C400 2x"},"classes":[]}],"_links":{"self":[{"href":"https:\/\/zjbocon.com\/wp-json\/wp\/v2\/posts\/2420","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/zjbocon.com\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/zjbocon.com\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/zjbocon.com\/wp-json\/wp\/v2\/users\/234312599"}],"replies":[{"embeddable":true,"href":"https:\/\/zjbocon.com\/wp-json\/wp\/v2\/comments?post=2420"}],"version-history":[{"count":5,"href":"https:\/\/zjbocon.com\/wp-json\/wp\/v2\/posts\/2420\/revisions"}],"predecessor-version":[{"id":8867,"href":"https:\/\/zjbocon.com\/wp-json\/wp\/v2\/posts\/2420\/revisions\/8867"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/zjbocon.com\/wp-json\/wp\/v2\/media\/8485"}],"wp:attachment":[{"href":"https:\/\/zjbocon.com\/wp-json\/wp\/v2\/media?parent=2420"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/zjbocon.com\/wp-json\/wp\/v2\/categories?post=2420"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/zjbocon.com\/wp-json\/wp\/v2\/tags?post=2420"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}