{"id":2471,"date":"2024-12-23T09:49:40","date_gmt":"2024-12-23T01:49:40","guid":{"rendered":"https:\/\/zjbocon.com\/?p=2471"},"modified":"2025-10-01T19:14:06","modified_gmt":"2025-10-01T11:14:06","slug":"safety-requirements-for-using-ethylene-oxide-in-sterilization","status":"publish","type":"post","link":"https:\/\/zjbocon.com\/?p=2471","title":{"rendered":"Safety Requirements for Using Ethylene Oxide in sterilization"},"content":{"rendered":"\n<div class=\"wp-block-uagb-image uagb-block-3a59f9d8 wp-block-uagb-image--layout-default wp-block-uagb-image--effect-static wp-block-uagb-image--align-none\"><figure class=\"wp-block-uagb-image__figure\"><img loading=\"lazy\" decoding=\"async\" src=\"https:\/\/zjbocon.com\/wp-content\/uploads\/2024\/10\/Electrical-Scale.png\" alt=\"\" class=\"uag-image-1673\" width=\"255\" height=\"569\" title=\"Electrical Scale\" role=\"img\" \><\/figure><\/div>\n\n\n\n<ol class=\"wp-block-list\">\n<li>جب نس بندی کے چیمبر میں ایتھیلین آکسائیڈ کو آگ سے بچاؤ کی سہولیات سے لیس کیا جانا چاہئے۔<\/li>\n\n\n\n<li>ایتھیلین آکسائیڈ سلنڈروں کو ایک خشک، ہوادار کمرے میں الگ سے ذخیرہ کیا جانا چاہیے، جہاں تمباکو نوشی اور کھلے شعلوں کی سخت ممانعت ہو۔<\/li>\n\n\n\n<li>جراثیم کشی کے چیمبر میں روشنی دھماکے سے پاک ہونی چاہیے، اور کوئی بھی برقی آلات جو برقی چنگاریوں کا سبب بن سکتے ہیں سے گریز کیا جانا چاہیے۔ کھلے شعلوں کی سختی سے ممانعت ہے۔<\/li>\n\n\n\n<li>ہر قسم کی شے کو جراثیم سے پاک کرنے سے پہلے، قومی معیار GB18279-2000 کے مطابق پیرامیٹرز کی تصدیق ہونی چاہیے۔<\/li>\n\n\n\n<li>جراثیم کش کے کنٹرول سیکشن کو مرکزی یونٹ سے الگ سے نصب کیا جانا چاہیے (دیکھیں خاکہ D.1)۔<\/li>\n\n\n\n<li>نقل مکانی (فلشنگ) کا مرحلہ مکمل ہونے کے بعد، جراثیم سے پاک اشیاء کو 15 منٹ سے زیادہ مہر بند سٹرلائزیشن چیمبر میں نہیں رہنا چاہیے۔ بصورت دیگر، دروازہ کھولنے سے پہلے نقل مکانی کا مرحلہ دہرایا جانا چاہیے۔<\/li>\n\n\n\n<li>نس بندی میں ایتھیلین آکسائیڈ کے مکمل ہونے کے بعد، نقل مکانی کرنے والی ہوا پر متعلقہ نس بندی آپریشن کے ضوابط کے مطابق کارروائی کی جانی چاہیے۔ اشیاء کو ہٹانے کے لیے دروازہ کھولنے سے پہلے، وینٹیلیشن کو یقینی بنانے کے لیے محوری پنکھے کو آن کرنا چاہیے۔ سٹرلائزیشن چیمبر میں نقصان دہ بقایا گیسوں کی نمائش سے بچنے کے لیے دروازہ کھولنے کے بعد فوری طور پر اشیاء کو باہر نہ نکالیں۔<\/li>\n\n\n\n<li><strong>ادویات کا انتباہ:<\/strong> ادویات کی مقدار کی بنیاد پر، دباؤ یا وزن مقرر کریں۔ جب مطلوبہ خوراک تک پہنچ جائے گی، ایک قابل سماعت الرٹ آواز آئے گا۔ اس مقام پر، آپریٹر کو فوری طور پر ادویات کی بوتل کے سوئچ اور مین یونٹ کے ڈوزنگ والو کو بند کرنا چاہیے۔<\/li>\n\n\n\n<li>ایتھیلین آکسائیڈ مکسڈ گیسوں کے استعمال کنندگان کو دوا کی بوتل کے آؤٹ لیٹ پر پریشر ریگولیٹر (صارف کے ذریعے نصب) نصب کرنا چاہیے تاکہ بوتل کے آؤٹ لیٹ پریشر کو 0.4 MPa سے کم کیا جا سکے، جس سے زیادہ دباؤ کو ڈوزنگ پائپ لائن میں لیک ہونے سے روکا جا سکے۔<\/li>\n\n\n\n<li>جراثیم کش سپلائی سسٹم کے کسی بھی حصے کو منقطع کرنے یا کھولنے سے پہلے، سسٹم کو صاف کرنا ضروری ہے (سوائے گیس ٹینک سپلائی سسٹم کے)۔<\/li>\n\n\n\n<li>اگر نس بندی کے عمل کے دوران ڈور سیل گسکیٹ کا ہوا کا دباؤ 0.45 MPa سے نیچے آجاتا ہے، تو ربڑ کی مہر کو ہوا کی سپلائی بند کر دی جانی چاہیے، اور اس بات کو یقینی بنانے کے لیے کہ ربڑ کی مہر کا دباؤ 0.45 MPa سے زیادہ ہو۔ ایک ہی وقت میں، ایتھیلین آکسائڈ لیک کو سنبھالنے کے طریقہ کار کو جراثیم سے پاک کرنے اور اسے صاف کرنے کے لیے چالو کیا جانا چاہیے۔ اس کے بعد، ہوا کے اصل منبع کو بحال کرنے کے لیے اقدامات کیے جائیں۔<\/li>\n\n\n\n<li>اگر کام کی جگہ کا وینٹیلیشن سسٹم ناکام ہو جاتا ہے، تو آلات کو بند کر دینا چاہیے اور دوبارہ شروع نہیں کرنا چاہیے۔ اگر جراثیم کش ایجنٹ کے پہلے ہی چیمبر میں داخل ہونے کے دوران ناکامی واقع ہوتی ہے، تو آپریٹر کو جراثیم سے پاک اشیاء سے رابطہ کرنے کے لیے صرف اس صورت میں داخل ہونا چاہیے جب جراثیم کو ہٹانے اور فلش کرنے کے طریقہ کار کو مکمل طور پر مکمل کر لیا جائے۔<\/li>\n\n\n\n<li>ہر کام کے چکر کے بعد، ایتھیلین آکسائیڈ پائپ لائن سسٹم کو صاف کرنا چاہیے۔ میڈیا کی صفائی میں پانی، کمپریسڈ ہوا، یا بھاپ شامل ہو سکتی ہے۔ صارف کو ان علاقوں میں مقامی ایگزاسٹ سسٹم انسٹال کرنا چاہیے جہاں جراثیم کش گیس جمع ہو سکتی ہے، جیسے کہ جراثیم کش دروازے کے قریب، جراثیم سے پاک اشیاء کے لیے ذخیرہ کرنے کی جگہ، اور جراثیم کش ذخیرہ کرنے کی جگہ۔ ایگزاسٹ سسٹم کو کوئی ایسا مادہ خارج نہیں کرنا چاہیے جو خطرے کا باعث بن سکے۔<\/li>\n<\/ol>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>نوٹ:<\/strong> اس سے قطع نظر کہ آیا سامان معمول کے کام، خرابی، یا دیکھ بھال کی حالت میں ہے، اگر اہلکاروں کو جراثیم کشی کرنے والے چیمبر میں داخل ہونے کی ضرورت ہے، تو دروازے کو زمین پر نیچے یا سہارا دینا چاہیے۔ اس بات کی تصدیق ہونی چاہیے کہ دروازہ مقفل ہے اور اسے بند نہیں کیا جا سکتا۔ عملے کو چیمبر میں داخل ہونے سے پہلے چابی لے لینا چاہیے یا اسے محفوظ طریقے سے رکھنا چاہیے۔<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"h-contact\">رابطہ کریں۔<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">فون:<a href=\"https:\/\/wa.me\/8619975258603\">+8619975258603<\/a><\/p>\n\n\n\n<p class=\"wp-block-paragraph\">ای میل:<a href=\"mailto:hayley@hzbocon.com\">hayley@hzbocon.com<\/a><\/p>\n\n\n\n<p class=\"wp-block-paragraph\">مقامی سائٹ: کمرہ 1202، Caitong Zhongxin، Xiasha ڈسٹرکٹ، Hangzhou City، Zhejiang Province، China<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">ویب سائٹ:<a href=\"https:\/\/www.hzbocon.com\/\">hzbocon.com<\/a><a href=\"https:\/\/zjbocon.com\/\">&nbsp;zjbocon.com<\/a><\/p>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"h-know-more-about-us\">ہمارے بارے میں مزید جانیں۔<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\"><a href=\"https:\/\/zjbocon.com\/sterilization-for-spice\/\">مسالوں کے لیے ETO، Gamma، اور Steam Sterilization کا موازنہ کرنا<\/a><\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><a href=\"https:\/\/zjbocon.com\/understanding-eto-sterilizer-performance-keys-to-efficiency\/\">ETO Sterilizer کی کارکردگی کو سمجھنا: کارکردگی کی کلید<\/a><\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><a href=\"https:\/\/zjbocon.com\/ethylene-oxide-leak-handling-when-using-eto-sterilizer\/\">eto sterilizer استعمال کرتے وقت Ethylene Oxide Leak سے ہینڈلنگ<\/a><\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><a href=\"https:\/\/zjbocon.com\/safety-requirements-for-using-ethylene-oxide-in-sterilization\/\">نس بندی میں ایتھیلین آکسائیڈ کے استعمال کے لیے حفاظتی تقاضے<\/a><\/p>\n","protected":false},"excerpt":{"rendered":"<p>Note: Regardless of whether the equipment is in normal operation, malfunction, or maintenance state, if personnel need to enter the [&hellip;]<\/p>\n","protected":false},"author":234312599,"featured_media":1686,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_uag_custom_page_level_css":"","site-sidebar-layout":"default","site-content-layout":"","ast-site-content-layout":"default","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","ast-disable-related-posts":"","theme-transparent-header-meta":"","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"set","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"_jetpack_newsletter_access":"","_jetpack_dont_email_post_to_subs":false,"_jetpack_newsletter_tier_id":0,"_jetpack_memberships_contains_paywalled_content":false,"_jetpack_feature_clip_id":0,"_jetpack_memberships_contains_paid_content":false,"footnotes":"","jetpack_publicize_message":"","jetpack_publicize_feature_enabled":true,"jetpack_social_post_already_shared":false,"jetpack_social_options":{"image_generator_settings":{"template":"highway","enabled":false},"version":2},"jetpack_post_was_ever_published":false},"categories":[133125,133124],"tags":[],"class_list":["post-2471","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-company-news","category-eto-sterilizer"],"yoast_head":"<!-- This site is optimized with the Yoast SEO Premium plugin v27.2 (Yoast SEO v28.0) - https:\/\/yoast.com\/product\/yoast-seo-premium-wordpress\/ -->\n<title>نس بندی میں ایتھیلین آکسائیڈ کے استعمال کے لیے حفاظتی تقاضے - ETO STERILIZER<\/title>\n<meta name=\"description\" content=\"The ethylene oxide gas(Ethylene Oxide in sterilization) for the sterilizer should be supplied by dedicated steel cylinders.\" \>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \>\n<link rel=\"canonical\" href=\"https:\/\/zjbocon.com\/?p=2471\" \>\n<meta property=\"og:locale\" content=\"en_US\" \>\n<meta property=\"og:type\" content=\"article\" \>\n<meta property=\"og:title\" content=\"Safety Requirements for Using Ethylene Oxide in sterilization\" \>\n<meta property=\"og:description\" content=\"The ethylene oxide gas(Ethylene Oxide in sterilization) for the sterilizer should be supplied by dedicated steel cylinders.\" \>\n<meta property=\"og:url\" content=\"https:\/\/zjbocon.com\/?p=2471\" \>\n<meta property=\"og:site_name\" content=\"ETO STERILIZER\" \>\n<meta property=\"article:publisher\" content=\"https:\/\/www.facebook.com\/profile.php?id=100088482339878\" \>\n<meta property=\"article:author\" content=\"https:\/\/www.facebook.com\/profile.php?id=100088482339878\" \>\n<meta property=\"article:published_time\" content=\"2024-12-23T01:49:40+00:00\" \>\n<meta property=\"article:modified_time\" content=\"2025-10-01T11:14:06+00:00\" \>\n<meta property=\"og:image\" content=\"https:\/\/zjbocon.com\/wp-content\/uploads\/2024\/10\/Electrical-Scale.webp\" \>\n\t<meta property=\"og:image:width\" content=\"255\" \>\n\t<meta property=\"og:image:height\" content=\"569\" \>\n\t<meta property=\"og:image:type\" content=\"image\/webp\" \>\n<meta name=\"author\" content=\"Bocon Technical Team\" \>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \>\n<meta name=\"twitter:creator\" content=\"@BoconAnd\" \>\n<meta name=\"twitter:site\" content=\"@BoconAnd\" \>\n<meta name=\"twitter:label1\" content=\"Written by\" \>\n\t<meta name=\"twitter:data1\" content=\"Bocon Technical Team\" \>\n\t<meta name=\"twitter:label2\" content=\"Est. reading time\" \>\n\t<meta name=\"twitter:data2\" content=\"4 minutes\" \>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\\\/\\\/zjbocon.com\\\/?p=2471#article\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/zjbocon.com\\\/?p=2471\"},\"author\":{\"name\":\"Bocon Technical Team\",\"@id\":\"https:\\\/\\\/zjbocon.com\\\/#\\\/schema\\\/person\\\/f12be028b8ae9843a4396dcc8012b425\"},\"headline\":\"Safety Requirements for Using Ethylene Oxide in sterilization\",\"datePublished\":\"2024-12-23T01:49:40+00:00\",\"dateModified\":\"2025-10-01T11:14:06+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/zjbocon.com\\\/?p=2471\"},\"wordCount\":619,\"commentCount\":0,\"publisher\":{\"@id\":\"https:\\\/\\\/zjbocon.com\\\/#organization\"},\"image\":{\"@id\":\"https:\\\/\\\/zjbocon.com\\\/?p=2471#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/zjbocon.com\\\/wp-content\\\/uploads\\\/2024\\\/10\\\/Electrical-Scale.webp\",\"articleSection\":[\"Company News\",\"ETO STERILIZER\"],\"inLanguage\":\"ur\",\"potentialAction\":[{\"@type\":\"CommentAction\",\"name\":\"Comment\",\"target\":[\"https:\\\/\\\/zjbocon.com\\\/?p=2471#respond\"]}]},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/zjbocon.com\\\/?p=2471\",\"url\":\"https:\\\/\\\/zjbocon.com\\\/?p=2471\",\"name\":\"Safety Requirements for Using Ethylene Oxide in sterilization - ETO STERILIZER\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/zjbocon.com\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/zjbocon.com\\\/?p=2471#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/zjbocon.com\\\/?p=2471#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/zjbocon.com\\\/wp-content\\\/uploads\\\/2024\\\/10\\\/Electrical-Scale.webp\",\"datePublished\":\"2024-12-23T01:49:40+00:00\",\"dateModified\":\"2025-10-01T11:14:06+00:00\",\"description\":\"The ethylene oxide gas(Ethylene Oxide in sterilization) for the sterilizer should be supplied by dedicated ethylene oxide steel cylinders.\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/zjbocon.com\\\/?p=2471#breadcrumb\"},\"inLanguage\":\"ur\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/zjbocon.com\\\/?p=2471\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"ur\",\"@id\":\"https:\\\/\\\/zjbocon.com\\\/?p=2471#primaryimage\",\"url\":\"https:\\\/\\\/zjbocon.com\\\/wp-content\\\/uploads\\\/2024\\\/10\\\/Electrical-Scale.webp\",\"contentUrl\":\"https:\\\/\\\/zjbocon.com\\\/wp-content\\\/uploads\\\/2024\\\/10\\\/Electrical-Scale.webp\",\"width\":255,\"height\":569,\"caption\":\"eo gas\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/zjbocon.com\\\/?p=2471#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/zjbocon.com\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Safety Requirements for Using Ethylene Oxide in sterilization\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/zjbocon.com\\\/#website\",\"url\":\"https:\\\/\\\/zjbocon.com\\\/\",\"name\":\"ETO STERILIZER\",\"description\":\"One-stop Solution Supplier of Ethylene Oxide Sterilization\",\"publisher\":{\"@id\":\"https:\\\/\\\/zjbocon.com\\\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/zjbocon.com\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"ur\"},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/zjbocon.com\\\/#organization\",\"name\":\"ETO STERILIZER\",\"url\":\"https:\\\/\\\/zjbocon.com\\\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"ur\",\"@id\":\"https:\\\/\\\/zjbocon.com\\\/#\\\/schema\\\/logo\\\/image\\\/\",\"url\":\"https:\\\/\\\/zjbocon.com\\\/wp-content\\\/uploads\\\/2024\\\/10\\\/logo-1.webp\",\"contentUrl\":\"https:\\\/\\\/zjbocon.com\\\/wp-content\\\/uploads\\\/2024\\\/10\\\/logo-1.webp\",\"width\":180,\"height\":60,\"caption\":\"ETO STERILIZER\"},\"image\":{\"@id\":\"https:\\\/\\\/zjbocon.com\\\/#\\\/schema\\\/logo\\\/image\\\/\"},\"sameAs\":[\"https:\\\/\\\/www.facebook.com\\\/profile.php?id=100088482339878\",\"https:\\\/\\\/x.com\\\/BoconAnd\",\"https:\\\/\\\/www.linkedin.com\\\/in\\\/--06a221139\\\/\"]},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/zjbocon.com\\\/#\\\/schema\\\/person\\\/f12be028b8ae9843a4396dcc8012b425\",\"name\":\"Bocon Technical Team\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"ur\",\"@id\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/d7a825658be227f26b237e519f8541e05aabc9ff27b8eec4544a233a48c53be0?s=96&d=identicon&r=g\",\"url\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/d7a825658be227f26b237e519f8541e05aabc9ff27b8eec4544a233a48c53be0?s=96&d=identicon&r=g\",\"contentUrl\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/d7a825658be227f26b237e519f8541e05aabc9ff27b8eec4544a233a48c53be0?s=96&d=identicon&r=g\",\"caption\":\"Bocon Technical Team\"},\"sameAs\":[\"https:\\\/\\\/zjbocon.com\\\/\",\"https:\\\/\\\/www.facebook.com\\\/profile.php?id=100088482339878\",\"https:\\\/\\\/www.linkedin.com\\\/in\\\/\\\/hayley--968190269\\\/\"],\"url\":\"https:\\\/\\\/zjbocon.com\\\/?author=234312599\"}]}<\/script>\n<!-- \/ Yoast SEO Premium plugin. -->","yoast_head_json":{"title":"Safety Requirements for Using Ethylene Oxide in sterilization - ETO STERILIZER","description":"The ethylene oxide gas(Ethylene Oxide in sterilization) for the sterilizer should be supplied by dedicated ethylene oxide steel cylinders.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/zjbocon.com\/?p=2471","og_locale":"en_US","og_type":"article","og_title":"Safety Requirements for Using Ethylene Oxide in sterilization","og_description":"The ethylene oxide gas(Ethylene Oxide in sterilization) for the sterilizer should be supplied by dedicated ethylene oxide steel cylinders.","og_url":"https:\/\/zjbocon.com\/?p=2471","og_site_name":"ETO STERILIZER","article_publisher":"https:\/\/www.facebook.com\/profile.php?id=100088482339878","article_author":"https:\/\/www.facebook.com\/profile.php?id=100088482339878","article_published_time":"2024-12-23T01:49:40+00:00","article_modified_time":"2025-10-01T11:14:06+00:00","og_image":[{"width":255,"height":569,"url":"https:\/\/zjbocon.com\/wp-content\/uploads\/2024\/10\/Electrical-Scale.webp","type":"image\/webp"}],"author":"Bocon Technical Team","twitter_card":"summary_large_image","twitter_creator":"@BoconAnd","twitter_site":"@BoconAnd","twitter_misc":{"Written by":"Bocon Technical Team","Est. reading time":"4 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/zjbocon.com\/?p=2471#article","isPartOf":{"@id":"https:\/\/zjbocon.com\/?p=2471"},"author":{"name":"Bocon Technical Team","@id":"https:\/\/zjbocon.com\/#\/schema\/person\/f12be028b8ae9843a4396dcc8012b425"},"headline":"Safety Requirements for Using Ethylene Oxide in sterilization","datePublished":"2024-12-23T01:49:40+00:00","dateModified":"2025-10-01T11:14:06+00:00","mainEntityOfPage":{"@id":"https:\/\/zjbocon.com\/?p=2471"},"wordCount":619,"commentCount":0,"publisher":{"@id":"https:\/\/zjbocon.com\/#organization"},"image":{"@id":"https:\/\/zjbocon.com\/?p=2471#primaryimage"},"thumbnailUrl":"https:\/\/zjbocon.com\/wp-content\/uploads\/2024\/10\/Electrical-Scale.webp","articleSection":["Company News","ETO STERILIZER"],"inLanguage":"ur","potentialAction":[{"@type":"CommentAction","name":"Comment","target":["https:\/\/zjbocon.com\/?p=2471#respond"]}]},{"@type":"WebPage","@id":"https:\/\/zjbocon.com\/?p=2471","url":"https:\/\/zjbocon.com\/?p=2471","name":"Safety Requirements for Using Ethylene Oxide in sterilization - ETO STERILIZER","isPartOf":{"@id":"https:\/\/zjbocon.com\/#website"},"primaryImageOfPage":{"@id":"https:\/\/zjbocon.com\/?p=2471#primaryimage"},"image":{"@id":"https:\/\/zjbocon.com\/?p=2471#primaryimage"},"thumbnailUrl":"https:\/\/zjbocon.com\/wp-content\/uploads\/2024\/10\/Electrical-Scale.webp","datePublished":"2024-12-23T01:49:40+00:00","dateModified":"2025-10-01T11:14:06+00:00","description":"The ethylene oxide gas(Ethylene Oxide in sterilization) for the sterilizer should be supplied by dedicated ethylene oxide steel cylinders.","breadcrumb":{"@id":"https:\/\/zjbocon.com\/?p=2471#breadcrumb"},"inLanguage":"ur","potentialAction":[{"@type":"ReadAction","target":["https:\/\/zjbocon.com\/?p=2471"]}]},{"@type":"ImageObject","inLanguage":"ur","@id":"https:\/\/zjbocon.com\/?p=2471#primaryimage","url":"https:\/\/zjbocon.com\/wp-content\/uploads\/2024\/10\/Electrical-Scale.webp","contentUrl":"https:\/\/zjbocon.com\/wp-content\/uploads\/2024\/10\/Electrical-Scale.webp","width":255,"height":569,"caption":"eo gas"},{"@type":"BreadcrumbList","@id":"https:\/\/zjbocon.com\/?p=2471#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/zjbocon.com\/"},{"@type":"ListItem","position":2,"name":"Safety Requirements for Using Ethylene Oxide in sterilization"}]},{"@type":"WebSite","@id":"https:\/\/zjbocon.com\/#website","url":"https:\/\/zjbocon.com\/","name":"ETO STERILIZER","description":"One-stop Solution Supplier of Ethylene Oxide Sterilization","publisher":{"@id":"https:\/\/zjbocon.com\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/zjbocon.com\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"ur"},{"@type":"Organization","@id":"https:\/\/zjbocon.com\/#organization","name":"ETO STERILIZER","url":"https:\/\/zjbocon.com\/","logo":{"@type":"ImageObject","inLanguage":"ur","@id":"https:\/\/zjbocon.com\/#\/schema\/logo\/image\/","url":"https:\/\/zjbocon.com\/wp-content\/uploads\/2024\/10\/logo-1.webp","contentUrl":"https:\/\/zjbocon.com\/wp-content\/uploads\/2024\/10\/logo-1.webp","width":180,"height":60,"caption":"ETO STERILIZER"},"image":{"@id":"https:\/\/zjbocon.com\/#\/schema\/logo\/image\/"},"sameAs":["https:\/\/www.facebook.com\/profile.php?id=100088482339878","https:\/\/x.com\/BoconAnd","https:\/\/www.linkedin.com\/in\/--06a221139\/"]},{"@type":"Person","@id":"https:\/\/zjbocon.com\/#\/schema\/person\/f12be028b8ae9843a4396dcc8012b425","name":"Bocon Technical Team","image":{"@type":"ImageObject","inLanguage":"ur","@id":"https:\/\/secure.gravatar.com\/avatar\/d7a825658be227f26b237e519f8541e05aabc9ff27b8eec4544a233a48c53be0?s=96&d=identicon&r=g","url":"https:\/\/secure.gravatar.com\/avatar\/d7a825658be227f26b237e519f8541e05aabc9ff27b8eec4544a233a48c53be0?s=96&d=identicon&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/d7a825658be227f26b237e519f8541e05aabc9ff27b8eec4544a233a48c53be0?s=96&d=identicon&r=g","caption":"Bocon Technical Team"},"sameAs":["https:\/\/zjbocon.com\/","https:\/\/www.facebook.com\/profile.php?id=100088482339878","https:\/\/www.linkedin.com\/in\/\/hayley--968190269\/"],"url":"https:\/\/zjbocon.com\/?author=234312599"}]}},"jetpack_publicize_connections":[],"jetpack_featured_media_url":"https:\/\/zjbocon.com\/wp-content\/uploads\/2024\/10\/Electrical-Scale.webp","uagb_featured_image_src":{"full":["https:\/\/zjbocon.com\/wp-content\/uploads\/2024\/10\/Electrical-Scale.webp",255,569,false],"thumbnail":["https:\/\/zjbocon.com\/wp-content\/uploads\/2024\/10\/Electrical-Scale-150x150.webp",150,150,true],"medium":["https:\/\/zjbocon.com\/wp-content\/uploads\/2024\/10\/Electrical-Scale-134x300.webp",134,300,true],"medium_large":["https:\/\/zjbocon.com\/wp-content\/uploads\/2024\/10\/Electrical-Scale.webp",255,569,false],"large":["https:\/\/zjbocon.com\/wp-content\/uploads\/2024\/10\/Electrical-Scale.webp",255,569,false],"1536x1536":["https:\/\/zjbocon.com\/wp-content\/uploads\/2024\/10\/Electrical-Scale.webp",255,569,false],"2048x2048":["https:\/\/zjbocon.com\/wp-content\/uploads\/2024\/10\/Electrical-Scale.webp",255,569,false],"woocommerce_thumbnail":["https:\/\/zjbocon.com\/wp-content\/uploads\/2024\/10\/Electrical-Scale.webp",255,569,false],"woocommerce_single":["https:\/\/zjbocon.com\/wp-content\/uploads\/2024\/10\/Electrical-Scale.webp",255,569,false],"woocommerce_gallery_thumbnail":["https:\/\/zjbocon.com\/wp-content\/uploads\/2024\/10\/Electrical-Scale-100x100.webp",100,100,true]},"uagb_author_info":{"display_name":"Bocon Technical Team","author_link":"https:\/\/zjbocon.com\/?author=234312599"},"uagb_comment_info":0,"uagb_excerpt":"Note: Regardless of whether the equipment is in normal operation, malfunction, or maintenance state, if personnel need to enter the [&hellip;]","jetpack_likes_enabled":true,"jetpack_sharing_enabled":true,"jetpack_shortlink":"https:\/\/wp.me\/pgZDV6-DR","jetpack-related-posts":[{"id":2476,"url":"https:\/\/zjbocon.com\/?p=2476","url_meta":{"origin":2471,"position":0},"title":"Ethylene Oxide Leak Handling when using eto sterilizer","author":"Bocon Technical Team","date":"2024-12-23","format":false,"excerpt":"If a leak is detected in the eto sterilizer dosing pipeline during the administration process, immediately close the medication bottle, switch and the dosing valve on the main unit. Turn on the axial fan to ensure proper ventilation, and then proceed with repairs.","rel":"","context":"In &quot;Company News&quot;","block_context":{"text":"Company News","link":"https:\/\/zjbocon.com\/?cat=133125"},"img":{"alt_text":"","src":"https:\/\/i0.wp.com\/zjbocon.com\/wp-content\/uploads\/2025\/09\/ethylene-oxide-sterilization-19-scaled.webp?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/zjbocon.com\/wp-content\/uploads\/2025\/09\/ethylene-oxide-sterilization-19-scaled.webp?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/zjbocon.com\/wp-content\/uploads\/2025\/09\/ethylene-oxide-sterilization-19-scaled.webp?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/zjbocon.com\/wp-content\/uploads\/2025\/09\/ethylene-oxide-sterilization-19-scaled.webp?resize=700%2C400&ssl=1 2x, https:\/\/i0.wp.com\/zjbocon.com\/wp-content\/uploads\/2025\/09\/ethylene-oxide-sterilization-19-scaled.webp?resize=1050%2C600&ssl=1 3x, https:\/\/i0.wp.com\/zjbocon.com\/wp-content\/uploads\/2025\/09\/ethylene-oxide-sterilization-19-scaled.webp?resize=1400%2C800&ssl=1 4x"},"classes":[]},{"id":8958,"url":"https:\/\/zjbocon.com\/?p=8958","url_meta":{"origin":2471,"position":1},"title":"Understanding What is ETO Sterilizers: A Comprehensive Guide","author":"Bocon Technical Team","date":"2025-12-16","format":false,"excerpt":"Discover the essentials of ETO sterilizers and ethylene oxide sterilization, ensuring the highest hygiene standards in healthcare and beyond.","rel":"","context":"In &quot;Company News&quot;","block_context":{"text":"Company News","link":"https:\/\/zjbocon.com\/?cat=133125"},"img":{"alt_text":"","src":"https:\/\/i0.wp.com\/zjbocon.com\/wp-content\/uploads\/2024\/11\/eto-sterilizer-hzbocon-3.png?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/zjbocon.com\/wp-content\/uploads\/2024\/11\/eto-sterilizer-hzbocon-3.png?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/zjbocon.com\/wp-content\/uploads\/2024\/11\/eto-sterilizer-hzbocon-3.png?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/zjbocon.com\/wp-content\/uploads\/2024\/11\/eto-sterilizer-hzbocon-3.png?resize=700%2C400&ssl=1 2x, https:\/\/i0.wp.com\/zjbocon.com\/wp-content\/uploads\/2024\/11\/eto-sterilizer-hzbocon-3.png?resize=1050%2C600&ssl=1 3x"},"classes":[]},{"id":3093,"url":"https:\/\/zjbocon.com\/?p=3093","url_meta":{"origin":2471,"position":2},"title":"Introduction to Ethylene Oxide Sterilizers","author":"Bocon Technical Team","date":"2025-02-05","format":false,"excerpt":"Discover how ethylene oxide sterilizers work, their applications, benefits, and safety considerations. Learn why they are essential for medical and industrial sterilization.","rel":"","context":"In &quot;Company News&quot;","block_context":{"text":"Company News","link":"https:\/\/zjbocon.com\/?cat=133125"},"img":{"alt_text":"","src":"https:\/\/i0.wp.com\/zjbocon.com\/wp-content\/uploads\/2024\/11\/ethylene-oxide-sterilization-21.webp?resize=350%2C200","width":350,"height":200},"classes":[]},{"id":2453,"url":"https:\/\/zjbocon.com\/?p=2453","url_meta":{"origin":2471,"position":3},"title":"Microbial Killing Performance of Ethylene Oxide Sterilizers","author":"Bocon Technical Team","date":"2024-12-20","format":false,"excerpt":"Note 1: The Ethylene Oxide sterilization conditions must be obtained through validation confirmation and should be verified with monitoring and routine control during each sterilization cycle. The requirements for validation and routine control are outlined in GB 18279. Note 2: This testing method is also applicable to A class Ethylene\u2026","rel":"","context":"In &quot;Company News&quot;","block_context":{"text":"Company News","link":"https:\/\/zjbocon.com\/?cat=133125"},"img":{"alt_text":"eto sterilizer","src":"https:\/\/i0.wp.com\/zjbocon.com\/wp-content\/uploads\/2024\/10\/banner__.webp?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/zjbocon.com\/wp-content\/uploads\/2024\/10\/banner__.webp?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/zjbocon.com\/wp-content\/uploads\/2024\/10\/banner__.webp?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/zjbocon.com\/wp-content\/uploads\/2024\/10\/banner__.webp?resize=700%2C400&ssl=1 2x"},"classes":[]},{"id":2448,"url":"https:\/\/zjbocon.com\/?p=2448","url_meta":{"origin":2471,"position":4},"title":"eto sterilization Chamber Temperature Distribution Testing","author":"Bocon Technical Team","date":"2024-12-20","format":false,"excerpt":"The temperature of representative areas on the inner surfaces should be measured and recorded using temperature recording instruments that comply with the requirements of Appendix B.","rel":"","context":"In &quot;Company News&quot;","block_context":{"text":"Company News","link":"https:\/\/zjbocon.com\/?cat=133125"},"img":{"alt_text":"","src":"https:\/\/i0.wp.com\/zjbocon.com\/wp-content\/uploads\/2025\/09\/ethylene-oxide-sterilization-54.webp?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/zjbocon.com\/wp-content\/uploads\/2025\/09\/ethylene-oxide-sterilization-54.webp?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/zjbocon.com\/wp-content\/uploads\/2025\/09\/ethylene-oxide-sterilization-54.webp?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/zjbocon.com\/wp-content\/uploads\/2025\/09\/ethylene-oxide-sterilization-54.webp?resize=700%2C400&ssl=1 2x, https:\/\/i0.wp.com\/zjbocon.com\/wp-content\/uploads\/2025\/09\/ethylene-oxide-sterilization-54.webp?resize=1050%2C600&ssl=1 3x"},"classes":[]},{"id":2439,"url":"https:\/\/zjbocon.com\/?p=2439","url_meta":{"origin":2471,"position":5},"title":"Preparatory Work Before eto Sterilization","author":"Bocon Technical Team","date":"2024-12-17","format":false,"excerpt":"Appearance Inspection: Check the main unit, control rack, and electrical control cabinet for any damage on the surface.","rel":"","context":"In &quot;Company News&quot;","block_context":{"text":"Company News","link":"https:\/\/zjbocon.com\/?cat=133125"},"img":{"alt_text":"","src":"https:\/\/i0.wp.com\/zjbocon.com\/wp-content\/uploads\/2025\/09\/sterilizer-station-design-2.webp?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/zjbocon.com\/wp-content\/uploads\/2025\/09\/sterilizer-station-design-2.webp?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/zjbocon.com\/wp-content\/uploads\/2025\/09\/sterilizer-station-design-2.webp?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/zjbocon.com\/wp-content\/uploads\/2025\/09\/sterilizer-station-design-2.webp?resize=700%2C400&ssl=1 2x"},"classes":[]}],"_links":{"self":[{"href":"https:\/\/zjbocon.com\/index.php?rest_route=\/wp\/v2\/posts\/2471","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/zjbocon.com\/index.php?rest_route=\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/zjbocon.com\/index.php?rest_route=\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/zjbocon.com\/index.php?rest_route=\/wp\/v2\/users\/234312599"}],"replies":[{"embeddable":true,"href":"https:\/\/zjbocon.com\/index.php?rest_route=%2Fwp%2Fv2%2Fcomments&post=2471"}],"version-history":[{"count":5,"href":"https:\/\/zjbocon.com\/index.php?rest_route=\/wp\/v2\/posts\/2471\/revisions"}],"predecessor-version":[{"id":2499,"href":"https:\/\/zjbocon.com\/index.php?rest_route=\/wp\/v2\/posts\/2471\/revisions\/2499"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/zjbocon.com\/index.php?rest_route=\/wp\/v2\/media\/1686"}],"wp:attachment":[{"href":"https:\/\/zjbocon.com\/index.php?rest_route=%2Fwp%2Fv2%2Fmedia&parent=2471"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/zjbocon.com\/index.php?rest_route=%2Fwp%2Fv2%2Fcategories&post=2471"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/zjbocon.com\/index.php?rest_route=%2Fwp%2Fv2%2Ftags&post=2471"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}