{"id":2224,"date":"2024-11-22T09:47:27","date_gmt":"2024-11-22T01:47:27","guid":{"rendered":"https:\/\/zjbocon.com\/?p=2224"},"modified":"2026-02-09T09:59:21","modified_gmt":"2026-02-09T01:59:21","slug":"factors-affecting-the-eo-gas-sterilization-process","status":"publish","type":"post","link":"https:\/\/zjbocon.com\/factors-affecting-the-eo-gas-sterilization-process\/","title":{"rendered":"Factors Affecting the EO Gas Sterilization Process"},"content":{"rendered":"\n<p class=\"wp-block-paragraph\">Có nhiều yếu tố ảnh hưởng đến quá trình khử trùng khí EO, vui lòng xem những điều sau: <\/p>\n\n\n\n<div class=\"wp-block-uagb-image uagb-block-40de1a6e wp-block-uagb-image--layout-default wp-block-uagb-image--effect-static wp-block-uagb-image--align-none\"><figure class=\"wp-block-uagb-image__figure\"><img loading=\"lazy\" decoding=\"async\" src=\"https:\/\/zjbocon.com\/wp-content\/uploads\/2024\/10\/Pneumatic_Sliding_Door_Eto_Sterilizer.webp\" alt=\"ethylene oxide sterilization\" class=\"uag-image-1936\" width=\"341\" height=\"492\" title=\"Pneumatic_Sliding_Door_Eto_Sterilizer\" role=\"img\" \><\/figure><\/div>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"h-1-gas-concentration\">1. Nồng độ khí<\/h2>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Within a certain range of gas concentration, the higher the concentration, the better theEO Gas Sterilization effect; beyond 1000 mg\/L, the improvement in sterilization effect is not significant.<\/li>\n<\/ul>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"h-2-relative-humidity\">2. Độ ẩm tương đối<\/h2>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Khi độ ẩm tương đối nằm trong khoảng 40% -80%, không có sự khác biệt đáng kể về hiệu quả khử trùng; dưới 40%, hiệu quả khử trùng giảm đáng kể; trên 90% thì không có sự cải thiện rõ rệt và dễ tạo ra các giọt nước, ảnh hưởng xấu đến quá trình khử trùng.<\/li>\n<\/ul>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"h-3-temperature\">3. Nhiệt độ<\/h2>\n\n\n\n<ul class=\"wp-block-list\">\n<li>At temperatures between 30-65\u00b0C, for every increase of 10\u00b0C, the EO Gas Sterilization effect doubles; above 65\u00b0C, there is no significant improvement in sterilization effect.<\/li>\n<\/ul>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"h-time\">Thời gian<\/h2>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Nồng độ ETO cao hơn đòi hỏi thời gian hành động ngắn hơn; nồng độ ETO thấp hơn đòi hỏi thời gian hành động lâu hơn.<\/li>\n<\/ul>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"h-survival-probability\">Xác suất sống sót<\/h3>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Thời gian khử trùng bằng khí EO càng dài thì khả năng sống sót của vi sinh vật trong sản phẩm càng thấp (hiệu quả khử trùng càng tốt).<\/li>\n\n\n\n<li>Thời gian khử trùng bằng khí EO có mối quan hệ tuyến tính với logarit của số lượng vi sinh vật sống sót (đây là cơ sở lý thuyết quan trọng nhất để xác định tỷ lệ tử vong).<\/li>\n<\/ul>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"h-other-influencing-factors\">Các yếu tố ảnh hưởng khác<\/h2>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"h-product-characteristics\">Đặc tính sản phẩm<\/h3>\n\n\n\n<ol class=\"wp-block-list\">\n<li><strong>Vật liệu và cấu trúc sản phẩm<\/strong>:\n<ul class=\"wp-block-list\">\n<li>The structure affects gas ingress and egress; some materials are unsuitable for ethylene oxide sterilization, and certain materials need to absorb more moisture\/heat.<\/li>\n<\/ul>\n<\/li>\n\n\n\n<li><strong>Vật liệu đóng gói<\/strong>.<\/li>\n\n\n\n<li><strong>Ô nhiễm ban đầu<\/strong>:\n<ul class=\"wp-block-list\">\n<li>Số lượng và loại vi khuẩn gây ô nhiễm ban đầu trong sản phẩm (các phương pháp như xác suất tồn dư và đếm trực tiếp có yêu cầu về mức độ ô nhiễm ban đầu; một số sản phẩm có yêu cầu về nội độc tố; một số vi sinh vật có biểu hiện kháng ethylene oxit).<\/li>\n<\/ul>\n<\/li>\n<\/ol>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"h-process-operations\">Quy trình hoạt động<\/h3>\n\n\n\n<ol class=\"wp-block-list\">\n<li><strong>Mức độ chân không<\/strong>:\n<ul class=\"wp-block-list\">\n<li>Ảnh hưởng đến sự khuếch tán và thâm nhập của khí, ảnh hưởng đến nồng độ khí tác dụng lên sản phẩm; ảnh hưởng đến an toàn bao bì, an toàn sản phẩm; ảnh hưởng đến hiệu quả dịch chuyển và dư lượng.<\/li>\n<\/ul>\n<\/li>\n\n\n\n<li><strong>Điều kiện tải<\/strong>:\n<ul class=\"wp-block-list\">\n<li>Affects heat\/wet penetration and distribution; influences gas circulation.<\/li>\n<\/ul>\n<\/li>\n<\/ol>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"h-if-you-want-to-know-more-about-ethylene-oxide-sterilization\">NẾU BẠN MUỐN BIẾT THÊM Về Khử trùng bằng Ethylene Oxide<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Điện thoại:<a href=\"https:\/\/wa.me\/8619975258603\">+8619975258603<\/a><\/p>\n\n\n\n<p class=\"wp-block-paragraph\">E-mail:<a href=\"mailto:hayley@hzbocon.com\">hayley@hzbocon.com<\/a><\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Địa điểm địa phương: Phòng 1202, Caitong Zhongxin, Quận Xiasha, Thành phố Hàng Châu, Tỉnh Chiết Giang, Trung Quốc<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Website:\u00a0<a href=\"https:\/\/www.hzbocon.com\/\">hzbocon.com<\/a><a href=\"https:\/\/zjbocon.com\/\">  zjbocon.com<\/a><\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><\/p>\n","protected":false},"excerpt":{"rendered":"<p>Within a certain range of gas concentration, the higher the concentration, the better theEO Gas Sterilization effect; beyond 1000 mg\/L, the improvement in sterilization effect is not significant.<\/p>\n","protected":false},"author":234312599,"featured_media":8451,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_uag_custom_page_level_css":"","site-sidebar-layout":"default","site-content-layout":"","ast-site-content-layout":"default","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","ast-disable-related-posts":"","theme-transparent-header-meta":"","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"set","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"_jetpack_newsletter_access":"","_jetpack_dont_email_post_to_subs":false,"_jetpack_newsletter_tier_id":0,"_jetpack_memberships_contains_paywalled_content":false,"_jetpack_feature_clip_id":0,"_jetpack_memberships_contains_paid_content":false,"footnotes":"","jetpack_publicize_message":"","jetpack_publicize_feature_enabled":true,"jetpack_social_post_already_shared":false,"jetpack_social_options":{"image_generator_settings":{"template":"highway","enabled":false},"version":2},"jetpack_post_was_ever_published":false},"categories":[133124],"tags":[],"class_list":["post-2224","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-eto-sterilizer"],"yoast_head":"<!-- This site is optimized with the Yoast SEO Premium plugin v27.2 (Yoast SEO v28.0) - https:\/\/yoast.com\/product\/yoast-seo-premium-wordpress\/ -->\n<title>Các yếu tố ảnh hưởng đến quá trình tiệt trùng bằng khí EO - ETO STERILIZER<\/title>\n<meta name=\"description\" content=\"There are many Factors Affecting in the EO Gas Sterilization Process, pls view following: 1. Concentration\" \>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \>\n<link rel=\"canonical\" href=\"https:\/\/zjbocon.com\/factors-affecting-the-eo-gas-sterilization-process\/\" \>\n<meta property=\"og:locale\" content=\"vi_VN\" \>\n<meta property=\"og:type\" content=\"article\" \>\n<meta property=\"og:title\" content=\"Factors Affecting the EO Gas Sterilization Process\" \>\n<meta property=\"og:description\" content=\"There are many Factors Affecting in the EO Gas Sterilization Process, pls view following: 1. Concentration\" \>\n<meta property=\"og:url\" content=\"https:\/\/zjbocon.com\/factors-affecting-the-eo-gas-sterilization-process\/\" \>\n<meta property=\"og:site_name\" content=\"ETO STERILIZER\" \>\n<meta property=\"article:publisher\" content=\"https:\/\/www.facebook.com\/profile.php?id=100088482339878\" \>\n<meta property=\"article:author\" content=\"https:\/\/www.facebook.com\/profile.php?id=100088482339878\" \>\n<meta property=\"article:published_time\" content=\"2024-11-22T01:47:27+00:00\" \>\n<meta property=\"article:modified_time\" content=\"2026-02-09T01:59:21+00:00\" \>\n<meta property=\"og:image\" content=\"https:\/\/zjbocon.com\/wp-content\/uploads\/2025\/09\/ethylene-oxide-sterilization-10-scaled.webp\" \>\n\t<meta property=\"og:image:width\" content=\"2560\" \>\n\t<meta property=\"og:image:height\" content=\"1920\" \>\n\t<meta property=\"og:image:type\" content=\"image\/webp\" \>\n<meta name=\"author\" content=\"Bocon Technical Team\" \>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \>\n<meta name=\"twitter:creator\" content=\"@BoconAnd\" \>\n<meta name=\"twitter:site\" content=\"@BoconAnd\" \>\n<meta name=\"twitter:label1\" content=\"Written by\" \>\n\t<meta name=\"twitter:data1\" content=\"Bocon Technical Team\" \>\n\t<meta name=\"twitter:label2\" content=\"Est. reading time\" \>\n\t<meta name=\"twitter:data2\" content=\"2 minutes\" \>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\\\/\\\/zjbocon.com\\\/factors-affecting-the-eo-gas-sterilization-process\\\/#article\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/zjbocon.com\\\/factors-affecting-the-eo-gas-sterilization-process\\\/\"},\"author\":{\"name\":\"Bocon Technical Team\",\"@id\":\"https:\\\/\\\/zjbocon.com\\\/#\\\/schema\\\/person\\\/f12be028b8ae9843a4396dcc8012b425\"},\"headline\":\"Factors Affecting the EO Gas Sterilization Process\",\"datePublished\":\"2024-11-22T01:47:27+00:00\",\"dateModified\":\"2026-02-09T01:59:21+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/zjbocon.com\\\/factors-affecting-the-eo-gas-sterilization-process\\\/\"},\"wordCount\":333,\"commentCount\":0,\"publisher\":{\"@id\":\"https:\\\/\\\/zjbocon.com\\\/#organization\"},\"image\":{\"@id\":\"https:\\\/\\\/zjbocon.com\\\/factors-affecting-the-eo-gas-sterilization-process\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/zjbocon.com\\\/wp-content\\\/uploads\\\/2025\\\/09\\\/ethylene-oxide-sterilization-10-scaled.webp\",\"articleSection\":[\"ETO STERILIZER\"],\"inLanguage\":\"vi\",\"potentialAction\":[{\"@type\":\"CommentAction\",\"name\":\"Comment\",\"target\":[\"https:\\\/\\\/zjbocon.com\\\/factors-affecting-the-eo-gas-sterilization-process\\\/#respond\"]}]},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/zjbocon.com\\\/factors-affecting-the-eo-gas-sterilization-process\\\/\",\"url\":\"https:\\\/\\\/zjbocon.com\\\/factors-affecting-the-eo-gas-sterilization-process\\\/\",\"name\":\"Factors Affecting the EO Gas Sterilization Process - ETO STERILIZER\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/zjbocon.com\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/zjbocon.com\\\/factors-affecting-the-eo-gas-sterilization-process\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/zjbocon.com\\\/factors-affecting-the-eo-gas-sterilization-process\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/zjbocon.com\\\/wp-content\\\/uploads\\\/2025\\\/09\\\/ethylene-oxide-sterilization-10-scaled.webp\",\"datePublished\":\"2024-11-22T01:47:27+00:00\",\"dateModified\":\"2026-02-09T01:59:21+00:00\",\"description\":\"There are many Factors Affecting in the EO Gas Sterilization Process, pls view the following: 1. Gas Concentration\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/zjbocon.com\\\/factors-affecting-the-eo-gas-sterilization-process\\\/#breadcrumb\"},\"inLanguage\":\"vi\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/zjbocon.com\\\/factors-affecting-the-eo-gas-sterilization-process\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"vi\",\"@id\":\"https:\\\/\\\/zjbocon.com\\\/factors-affecting-the-eo-gas-sterilization-process\\\/#primaryimage\",\"url\":\"https:\\\/\\\/zjbocon.com\\\/wp-content\\\/uploads\\\/2025\\\/09\\\/ethylene-oxide-sterilization-10-scaled.webp\",\"contentUrl\":\"https:\\\/\\\/zjbocon.com\\\/wp-content\\\/uploads\\\/2025\\\/09\\\/ethylene-oxide-sterilization-10-scaled.webp\",\"width\":2560,\"height\":1920},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/zjbocon.com\\\/factors-affecting-the-eo-gas-sterilization-process\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/zjbocon.com\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Factors Affecting the EO Gas Sterilization Process\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/zjbocon.com\\\/#website\",\"url\":\"https:\\\/\\\/zjbocon.com\\\/\",\"name\":\"ETO STERILIZER\",\"description\":\"One-stop Solution Supplier of Ethylene Oxide Sterilization\",\"publisher\":{\"@id\":\"https:\\\/\\\/zjbocon.com\\\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/zjbocon.com\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"vi\"},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/zjbocon.com\\\/#organization\",\"name\":\"ETO STERILIZER\",\"url\":\"https:\\\/\\\/zjbocon.com\\\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"vi\",\"@id\":\"https:\\\/\\\/zjbocon.com\\\/#\\\/schema\\\/logo\\\/image\\\/\",\"url\":\"https:\\\/\\\/zjbocon.com\\\/wp-content\\\/uploads\\\/2024\\\/10\\\/logo-1.webp\",\"contentUrl\":\"https:\\\/\\\/zjbocon.com\\\/wp-content\\\/uploads\\\/2024\\\/10\\\/logo-1.webp\",\"width\":180,\"height\":60,\"caption\":\"ETO STERILIZER\"},\"image\":{\"@id\":\"https:\\\/\\\/zjbocon.com\\\/#\\\/schema\\\/logo\\\/image\\\/\"},\"sameAs\":[\"https:\\\/\\\/www.facebook.com\\\/profile.php?id=100088482339878\",\"https:\\\/\\\/x.com\\\/BoconAnd\",\"https:\\\/\\\/www.linkedin.com\\\/in\\\/--06a221139\\\/\"]},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/zjbocon.com\\\/#\\\/schema\\\/person\\\/f12be028b8ae9843a4396dcc8012b425\",\"name\":\"Bocon Technical Team\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"vi\",\"@id\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/d7a825658be227f26b237e519f8541e05aabc9ff27b8eec4544a233a48c53be0?s=96&d=identicon&r=g\",\"url\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/d7a825658be227f26b237e519f8541e05aabc9ff27b8eec4544a233a48c53be0?s=96&d=identicon&r=g\",\"contentUrl\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/d7a825658be227f26b237e519f8541e05aabc9ff27b8eec4544a233a48c53be0?s=96&d=identicon&r=g\",\"caption\":\"Bocon Technical Team\"},\"sameAs\":[\"https:\\\/\\\/zjbocon.com\\\/\",\"https:\\\/\\\/www.facebook.com\\\/profile.php?id=100088482339878\",\"https:\\\/\\\/www.linkedin.com\\\/in\\\/\\\/hayley--968190269\\\/\"],\"url\":\"https:\\\/\\\/zjbocon.com\\\/author\\\/15657615935a\\\/\"}]}<\/script>\n<!-- \/ Yoast SEO Premium plugin. -->","yoast_head_json":{"title":"Factors Affecting the EO Gas Sterilization Process - ETO STERILIZER","description":"There are many Factors Affecting in the EO Gas Sterilization Process, pls view the following: 1. Gas Concentration","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/zjbocon.com\/factors-affecting-the-eo-gas-sterilization-process\/","og_locale":"vi_VN","og_type":"article","og_title":"Factors Affecting the EO Gas Sterilization Process","og_description":"There are many Factors Affecting in the EO Gas Sterilization Process, pls view the following: 1. Gas Concentration","og_url":"https:\/\/zjbocon.com\/factors-affecting-the-eo-gas-sterilization-process\/","og_site_name":"ETO STERILIZER","article_publisher":"https:\/\/www.facebook.com\/profile.php?id=100088482339878","article_author":"https:\/\/www.facebook.com\/profile.php?id=100088482339878","article_published_time":"2024-11-22T01:47:27+00:00","article_modified_time":"2026-02-09T01:59:21+00:00","og_image":[{"width":2560,"height":1920,"url":"https:\/\/zjbocon.com\/wp-content\/uploads\/2025\/09\/ethylene-oxide-sterilization-10-scaled.webp","type":"image\/webp"}],"author":"Bocon Technical Team","twitter_card":"summary_large_image","twitter_creator":"@BoconAnd","twitter_site":"@BoconAnd","twitter_misc":{"Written by":"Bocon Technical Team","Est. reading time":"2 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/zjbocon.com\/factors-affecting-the-eo-gas-sterilization-process\/#article","isPartOf":{"@id":"https:\/\/zjbocon.com\/factors-affecting-the-eo-gas-sterilization-process\/"},"author":{"name":"Bocon Technical Team","@id":"https:\/\/zjbocon.com\/#\/schema\/person\/f12be028b8ae9843a4396dcc8012b425"},"headline":"Factors Affecting the EO Gas Sterilization Process","datePublished":"2024-11-22T01:47:27+00:00","dateModified":"2026-02-09T01:59:21+00:00","mainEntityOfPage":{"@id":"https:\/\/zjbocon.com\/factors-affecting-the-eo-gas-sterilization-process\/"},"wordCount":333,"commentCount":0,"publisher":{"@id":"https:\/\/zjbocon.com\/#organization"},"image":{"@id":"https:\/\/zjbocon.com\/factors-affecting-the-eo-gas-sterilization-process\/#primaryimage"},"thumbnailUrl":"https:\/\/zjbocon.com\/wp-content\/uploads\/2025\/09\/ethylene-oxide-sterilization-10-scaled.webp","articleSection":["ETO STERILIZER"],"inLanguage":"vi","potentialAction":[{"@type":"CommentAction","name":"Comment","target":["https:\/\/zjbocon.com\/factors-affecting-the-eo-gas-sterilization-process\/#respond"]}]},{"@type":"WebPage","@id":"https:\/\/zjbocon.com\/factors-affecting-the-eo-gas-sterilization-process\/","url":"https:\/\/zjbocon.com\/factors-affecting-the-eo-gas-sterilization-process\/","name":"Factors Affecting the EO Gas Sterilization Process - ETO STERILIZER","isPartOf":{"@id":"https:\/\/zjbocon.com\/#website"},"primaryImageOfPage":{"@id":"https:\/\/zjbocon.com\/factors-affecting-the-eo-gas-sterilization-process\/#primaryimage"},"image":{"@id":"https:\/\/zjbocon.com\/factors-affecting-the-eo-gas-sterilization-process\/#primaryimage"},"thumbnailUrl":"https:\/\/zjbocon.com\/wp-content\/uploads\/2025\/09\/ethylene-oxide-sterilization-10-scaled.webp","datePublished":"2024-11-22T01:47:27+00:00","dateModified":"2026-02-09T01:59:21+00:00","description":"There are many Factors Affecting in the EO Gas Sterilization Process, pls view the following: 1. Gas Concentration","breadcrumb":{"@id":"https:\/\/zjbocon.com\/factors-affecting-the-eo-gas-sterilization-process\/#breadcrumb"},"inLanguage":"vi","potentialAction":[{"@type":"ReadAction","target":["https:\/\/zjbocon.com\/factors-affecting-the-eo-gas-sterilization-process\/"]}]},{"@type":"ImageObject","inLanguage":"vi","@id":"https:\/\/zjbocon.com\/factors-affecting-the-eo-gas-sterilization-process\/#primaryimage","url":"https:\/\/zjbocon.com\/wp-content\/uploads\/2025\/09\/ethylene-oxide-sterilization-10-scaled.webp","contentUrl":"https:\/\/zjbocon.com\/wp-content\/uploads\/2025\/09\/ethylene-oxide-sterilization-10-scaled.webp","width":2560,"height":1920},{"@type":"BreadcrumbList","@id":"https:\/\/zjbocon.com\/factors-affecting-the-eo-gas-sterilization-process\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/zjbocon.com\/"},{"@type":"ListItem","position":2,"name":"Factors Affecting the EO Gas Sterilization Process"}]},{"@type":"WebSite","@id":"https:\/\/zjbocon.com\/#website","url":"https:\/\/zjbocon.com\/","name":"ETO STERILIZER","description":"One-stop Solution Supplier of Ethylene Oxide Sterilization","publisher":{"@id":"https:\/\/zjbocon.com\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/zjbocon.com\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"vi"},{"@type":"Organization","@id":"https:\/\/zjbocon.com\/#organization","name":"ETO STERILIZER","url":"https:\/\/zjbocon.com\/","logo":{"@type":"ImageObject","inLanguage":"vi","@id":"https:\/\/zjbocon.com\/#\/schema\/logo\/image\/","url":"https:\/\/zjbocon.com\/wp-content\/uploads\/2024\/10\/logo-1.webp","contentUrl":"https:\/\/zjbocon.com\/wp-content\/uploads\/2024\/10\/logo-1.webp","width":180,"height":60,"caption":"ETO STERILIZER"},"image":{"@id":"https:\/\/zjbocon.com\/#\/schema\/logo\/image\/"},"sameAs":["https:\/\/www.facebook.com\/profile.php?id=100088482339878","https:\/\/x.com\/BoconAnd","https:\/\/www.linkedin.com\/in\/--06a221139\/"]},{"@type":"Person","@id":"https:\/\/zjbocon.com\/#\/schema\/person\/f12be028b8ae9843a4396dcc8012b425","name":"Bocon Technical Team","image":{"@type":"ImageObject","inLanguage":"vi","@id":"https:\/\/secure.gravatar.com\/avatar\/d7a825658be227f26b237e519f8541e05aabc9ff27b8eec4544a233a48c53be0?s=96&d=identicon&r=g","url":"https:\/\/secure.gravatar.com\/avatar\/d7a825658be227f26b237e519f8541e05aabc9ff27b8eec4544a233a48c53be0?s=96&d=identicon&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/d7a825658be227f26b237e519f8541e05aabc9ff27b8eec4544a233a48c53be0?s=96&d=identicon&r=g","caption":"Bocon Technical Team"},"sameAs":["https:\/\/zjbocon.com\/","https:\/\/www.facebook.com\/profile.php?id=100088482339878","https:\/\/www.linkedin.com\/in\/\/hayley--968190269\/"],"url":"https:\/\/zjbocon.com\/author\/15657615935a\/"}]}},"jetpack_publicize_connections":[],"jetpack_featured_media_url":"https:\/\/zjbocon.com\/wp-content\/uploads\/2025\/09\/ethylene-oxide-sterilization-10-scaled.webp","uagb_featured_image_src":{"full":["https:\/\/zjbocon.com\/wp-content\/uploads\/2025\/09\/ethylene-oxide-sterilization-10-scaled.webp",2560,1920,false],"thumbnail":["https:\/\/zjbocon.com\/wp-content\/uploads\/2025\/09\/ethylene-oxide-sterilization-10-150x150.webp",150,150,true],"medium":["https:\/\/zjbocon.com\/wp-content\/uploads\/2025\/09\/ethylene-oxide-sterilization-10-300x225.webp",300,225,true],"medium_large":["https:\/\/zjbocon.com\/wp-content\/uploads\/2025\/09\/ethylene-oxide-sterilization-10-768x576.webp",768,576,true],"large":["https:\/\/zjbocon.com\/wp-content\/uploads\/2025\/09\/ethylene-oxide-sterilization-10-1024x768.webp",1024,768,true],"1536x1536":["https:\/\/zjbocon.com\/wp-content\/uploads\/2025\/09\/ethylene-oxide-sterilization-10-1536x1152.webp",1536,1152,true],"2048x2048":["https:\/\/zjbocon.com\/wp-content\/uploads\/2025\/09\/ethylene-oxide-sterilization-10-2048x1536.webp",2048,1536,true],"woocommerce_thumbnail":["https:\/\/zjbocon.com\/wp-content\/uploads\/2025\/09\/ethylene-oxide-sterilization-10-600x600.webp",600,600,true],"woocommerce_single":["https:\/\/zjbocon.com\/wp-content\/uploads\/2025\/09\/ethylene-oxide-sterilization-10-600x450.webp",600,450,true],"woocommerce_gallery_thumbnail":["https:\/\/zjbocon.com\/wp-content\/uploads\/2025\/09\/ethylene-oxide-sterilization-10-100x100.webp",100,100,true]},"uagb_author_info":{"display_name":"Bocon Technical Team","author_link":"https:\/\/zjbocon.com\/author\/15657615935a\/"},"uagb_comment_info":13,"uagb_excerpt":"Within a certain range of gas concentration, the higher the concentration, the better theEO Gas Sterilization effect; beyond 1000 mg\/L, the improvement in sterilization effect is not significant.","jetpack_likes_enabled":true,"jetpack_sharing_enabled":true,"jetpack_shortlink":"https:\/\/wp.me\/pgZDV6-zS","jetpack-related-posts":[{"id":1950,"url":"https:\/\/zjbocon.com\/eto-sterilization-process\/","url_meta":{"origin":2224,"position":0},"title":"eto sterilization process","author":"Bocon Technical Team","date":"2024-10-23","format":false,"excerpt":"Eto Sterilization is conducted using a eto sterilizer located in a dedicated facility.","rel":"","context":"In &quot;ETO STERILIZER&quot;","block_context":{"text":"ETO STERILIZER","link":"https:\/\/zjbocon.com\/category\/eto-sterilizer\/"},"img":{"alt_text":"eto sterilization process","src":"https:\/\/i0.wp.com\/zjbocon.com\/wp-content\/uploads\/2024\/10\/eto-sterilization-process-e1729654271899.webp?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/zjbocon.com\/wp-content\/uploads\/2024\/10\/eto-sterilization-process-e1729654271899.webp?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/zjbocon.com\/wp-content\/uploads\/2024\/10\/eto-sterilization-process-e1729654271899.webp?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/zjbocon.com\/wp-content\/uploads\/2024\/10\/eto-sterilization-process-e1729654271899.webp?resize=700%2C400&ssl=1 2x"},"classes":[]},{"id":7277,"url":"https:\/\/zjbocon.com\/performance-qualificationpq-ppq-in-eo-sterilization\/","url_meta":{"origin":2224,"position":1},"title":"Performance Qualification(pq)-ppq in eo sterilization","author":"Bocon Technical Team","date":"2025-07-29","format":false,"excerpt":"Physical Performance Qualification (PPQ)\u2022 It shall be demonstrated that all specified acceptance criteria are reproducible throughout the entire process.How many runs should the PPQ process perform?\u2022 To demonstrate process reproducibility, at least 3 runs are required;\u2022 If 3 half-cycles were run during the MPQ process, then at least 1 additional\u2026","rel":"","context":"In &quot;Company News&quot;","block_context":{"text":"Company News","link":"https:\/\/zjbocon.com\/category\/company-news\/"},"img":{"alt_text":"","src":"https:\/\/i0.wp.com\/zjbocon.com\/wp-content\/uploads\/2025\/09\/eto-sterilizer-11.webp?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/zjbocon.com\/wp-content\/uploads\/2025\/09\/eto-sterilizer-11.webp?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/zjbocon.com\/wp-content\/uploads\/2025\/09\/eto-sterilizer-11.webp?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/zjbocon.com\/wp-content\/uploads\/2025\/09\/eto-sterilizer-11.webp?resize=700%2C400&ssl=1 2x, https:\/\/i0.wp.com\/zjbocon.com\/wp-content\/uploads\/2025\/09\/eto-sterilizer-11.webp?resize=1050%2C600&ssl=1 3x"},"classes":[]},{"id":3100,"url":"https:\/\/zjbocon.com\/how-does-ethylene-oxide-gas-sterilization-kill-microorganisms\/","url_meta":{"origin":2224,"position":2},"title":"How Does Ethylene Oxide Gas Sterilization Kill Microorganisms?","author":"Bocon Technical Team","date":"2025-02-05","format":false,"excerpt":"How Does Ethylene Oxide Gas Sterilization Work? The effectiveness of ethylene oxide gas sterilization lies in its ability to disrupt the cellular structure of microorganisms. Here\u2019s a step-by-step breakdown of how it works: 1.\u00a0Penetration of EO Gas Ethylene oxide gas is highly penetrative, meaning it can easily reach microorganisms even\u2026","rel":"","context":"In &quot;Company News&quot;","block_context":{"text":"Company News","link":"https:\/\/zjbocon.com\/category\/company-news\/"},"img":{"alt_text":"","src":"https:\/\/i0.wp.com\/zjbocon.com\/wp-content\/uploads\/2025\/09\/tp2.jpg?resize=350%2C200&ssl=1","width":350,"height":200},"classes":[]},{"id":3093,"url":"https:\/\/zjbocon.com\/introduction-to-ethylene-oxide-sterilizers\/","url_meta":{"origin":2224,"position":3},"title":"Introduction to Ethylene Oxide Sterilizers","author":"Bocon Technical Team","date":"2025-02-05","format":false,"excerpt":"Discover how ethylene oxide sterilizers work, their applications, benefits, and safety considerations. Learn why they are essential for medical and industrial sterilization.","rel":"","context":"In &quot;Company News&quot;","block_context":{"text":"Company News","link":"https:\/\/zjbocon.com\/category\/company-news\/"},"img":{"alt_text":"","src":"https:\/\/i0.wp.com\/zjbocon.com\/wp-content\/uploads\/2024\/11\/ethylene-oxide-sterilization-21.webp?resize=350%2C200","width":350,"height":200},"classes":[]},{"id":2004,"url":"https:\/\/zjbocon.com\/the-guide-to-ethylene-oxide-in-sterilization\/","url_meta":{"origin":2224,"position":4},"title":"The Guide to ethylene oxide in sterilization","author":"Bocon Technical Team","date":"2024-10-28","format":false,"excerpt":"ethylene oxide in sterilization Introduction ETO is a colorless gas that is flammable and explosive. The four essential parameters (operational ranges) of ethylene oxide in sterilization are: gas concentration (450 to 1200 mg\/l); temperature (37 to 63\u00b0C); relative humidity (40 to 80%)(water molecules carry ETO to reactive sites); and exposure\u2026","rel":"","context":"In &quot;ETO STERILIZER&quot;","block_context":{"text":"ETO STERILIZER","link":"https:\/\/zjbocon.com\/category\/eto-sterilizer\/"},"img":{"alt_text":"Industry_ETO_Sterilizer","src":"https:\/\/i0.wp.com\/zjbocon.com\/wp-content\/uploads\/2024\/10\/Industry_ETO_Sterilizer.webp?resize=350%2C200","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/zjbocon.com\/wp-content\/uploads\/2024\/10\/Industry_ETO_Sterilizer.webp?resize=350%2C200 1x, https:\/\/i0.wp.com\/zjbocon.com\/wp-content\/uploads\/2024\/10\/Industry_ETO_Sterilizer.webp?resize=525%2C300 1.5x, https:\/\/i0.wp.com\/zjbocon.com\/wp-content\/uploads\/2024\/10\/Industry_ETO_Sterilizer.webp?resize=700%2C400 2x"},"classes":[]},{"id":2128,"url":"https:\/\/zjbocon.com\/routine-monitoring-control-and-release-of-ethylene-oxide-sterilization\/","url_meta":{"origin":2224,"position":5},"title":"Routine Monitoring, Control, and Release of Ethylene Oxide Sterilization","author":"Bocon Technical Team","date":"2024-11-06","format":false,"excerpt":"The purpose of routine monitoring and control of EO (Ethylene Oxide) sterilization is to demonstrate that the confirmed and specified sterilization process has been applied to the product. Data from each sterilization cycle should be recorded and retained to prove that the confirmed sterilization process specifications have been met. This\u2026","rel":"","context":"In &quot;ETO STERILIZER&quot;","block_context":{"text":"ETO STERILIZER","link":"https:\/\/zjbocon.com\/category\/eto-sterilizer\/"},"img":{"alt_text":"","src":"https:\/\/i0.wp.com\/zjbocon.com\/wp-content\/uploads\/2025\/09\/ethylene-oxide-sterilization-70.webp?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/zjbocon.com\/wp-content\/uploads\/2025\/09\/ethylene-oxide-sterilization-70.webp?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/zjbocon.com\/wp-content\/uploads\/2025\/09\/ethylene-oxide-sterilization-70.webp?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/zjbocon.com\/wp-content\/uploads\/2025\/09\/ethylene-oxide-sterilization-70.webp?resize=700%2C400&ssl=1 2x, https:\/\/i0.wp.com\/zjbocon.com\/wp-content\/uploads\/2025\/09\/ethylene-oxide-sterilization-70.webp?resize=1050%2C600&ssl=1 3x, https:\/\/i0.wp.com\/zjbocon.com\/wp-content\/uploads\/2025\/09\/ethylene-oxide-sterilization-70.webp?resize=1400%2C800&ssl=1 4x"},"classes":[]}],"_links":{"self":[{"href":"https:\/\/zjbocon.com\/wp-json\/wp\/v2\/posts\/2224","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/zjbocon.com\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/zjbocon.com\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/zjbocon.com\/wp-json\/wp\/v2\/users\/234312599"}],"replies":[{"embeddable":true,"href":"https:\/\/zjbocon.com\/wp-json\/wp\/v2\/comments?post=2224"}],"version-history":[{"count":5,"href":"https:\/\/zjbocon.com\/wp-json\/wp\/v2\/posts\/2224\/revisions"}],"predecessor-version":[{"id":8876,"href":"https:\/\/zjbocon.com\/wp-json\/wp\/v2\/posts\/2224\/revisions\/8876"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/zjbocon.com\/wp-json\/wp\/v2\/media\/8451"}],"wp:attachment":[{"href":"https:\/\/zjbocon.com\/wp-json\/wp\/v2\/media?parent=2224"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/zjbocon.com\/wp-json\/wp\/v2\/categories?post=2224"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/zjbocon.com\/wp-json\/wp\/v2\/tags?post=2224"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}