Our hospital eto sterilizer sterilizer is a highly effective solutions by using Ethylene Oxide (ETO) sterilization, one of the most widely used methods for sterilizing medical equipment and supplies. We also suppluy industry eto sterilizer
Basic parameters of hospital eto sterilizer and Laboratory eto sterilizer
Sterilizer Photo Display
Characteristics of hospital eto sterilizer
A、Satety
Our Hospital / Laboratory ETO Sterilizer use Negative pressure sterilization, negative pressure cleaning, negative pressure residue removal, the whole process of negative pressure to ensure safety!
This hospitel eto sterilizer belongs to class B sterilizer, the sterilization temperature can be adjusted in 30℃~55℃. Sterilization, cleaning and residue removal processes, the sterilizer always maintains a relative negative pressure to ensure that ethylene oxide does not leak.
Even if leakage occurs, the control system will automatically detect the leakage, and automatically abort the sterilization process to send an alarm, and automatically discharge the ethylene oxide gas.
B、Residue removal and aeration
When the hospital eto sterilizer sterilization process reaches the end of the cleaning process, it automatically enters the residue removal (to fully ensure that the EO residue of the sterilized articles is minimized).
C、Continuous temperature monitoring
=Sterilization stage temperature is maintained within the selected temperature ± 3 ℃, once the temperature sensor detects a deviation from the predetermined temperature of 3 ℃, then the over-temperature protection device is automatically activated, and the text prompts the temperature abnormality and alarm, and interrupt the heating.
D、Humidity control
The humidity sensor is open and displayed throughout the sterilization process. According to the set humidity value, humidification is uniformly applied several times to ensure the right humidity level.
F、Automatically control of puncturing EO gas cartridge
Only when the dosing process is entered normally will the system automatically activate the dosing unit, puncturing the EO gas cartridge and releasing the ethylene oxide gas.
G、Sterilization process status display
Located in front of the liquid crystal display real-time continuous display of the sterilization process status. (e.g. temperature, humidity, pressure, time, sterilization process, etc.)
Implementation standard of hospital eto sterilizer
Our hospitel eto sterilizer use following standards
YY0503-2016 Ethylene Oxide Sterilizer
GB4793.1-2007 Safety requirements for measuring, controlling and
laboratory electrical equipment (Part I: General Requirements)
GB18279-2000 Confirmation and routine control of ethylene oxide sterilization of medical devices
GB/T18268.1 Electromagnetic compatibility requirements for electrical equipment for measurement, control and laboratory use
GB 4793.8-2008 Safety requirements for electrical equipment for measurement, control, and laboratory use – Part 2-042: Specific requirements for the treatment of medical materials with toxic gases and for pressure sterilizers and sterilizers intended for laboratory use