eo灭菌前的准备工作

我们需要在EO灭菌之前准备

  1. 外观检验: 检查主机,控制架和电气控制柜的表面上是否有任何损坏。
  2. 电源检查: 确保电源满足要求,并检查水泵和真空泵的旋转方向。
  3. 打开功率并观察仪器显示值是否正常;否则,请在重新启动之前切断电源,检查和维修。
  4. 管道检查: 检查供水,真空和药物输送管道中的泄漏,并确保所有阀门处于待机模式;必要时进行调整。
  5. 设置参数: For example, set the dosage amount. Place the medication bottle on an electronic scale (provided by the user), confirm the bottle weight, start the vacuum pump to reach the set pressure value, then open the medication bottle to deliver the medication. Generally, the dosage during eo eo Sterilization is 400–800 mg/L (referring to the pure ethylene oxide input; if it is a mixed gas containing ethylene oxide, ensure that the amount of ethylene oxide delivered meets the dosage requirements). When the delivered weight reaches the standard, the current pressure value corresponds to the dosage amount.
  6. Each time before eo Sterilization, verify that the parameter settings meet the needs for the items being sterilized; otherwise, reset the eo Sterilization parameters.