C.1 Ukuhlolwa Kwezinga Lokushisa Kwendawo Yangaphakathi Egunjini Le-eto Sterilization Chamber

C.1.1

Izinga lokushisa lezindawo ezimele ezindaweni ezingaphakathi kufanele zikalwe futhi zirekhodwe kusetshenziswa amathuluzi okurekhoda izinga lokushisa athobelana nezidingo zeSithasiselo B.

C.1.2

Indawo ngayinye engaphakathi kufanele ikalwe okungenani kanye (okungukuthi, ubuncane bamaphuzu okulinganisa angu-6 ahambisanayo). Kuma-sterilizer anenani eliphelele eliphakathi kuka-300 L no-8000 L, indawo ngayinye kufanele ikalwe okungenani izikhathi ezi-2. Kuwo wonke ama-4000 L wevolumu ephelele, amaphoyinti okulinganisa angu-6 engeziwe kufanele engezwe.

C.1.3

Lokhu kuhlolwa kufanele kwenziwe ngegumbi le-eto sterilization lingenalutho futhi iminyango ivaliwe, nakuba amathuluzi ayisizayo adingekayo ngenqubo yokuvala inzalo ye-eo angase afakwe ekamelweni.

C.1.4

Izinga lokushisa elishiwo noma yisiphi isigaba sokushisa ngaphambili ngumenzi kufanele lirekhodwe.

C.2 Ukuhlolwa Kwezinga Lokushisa Kwegumbi Le-eto Sterilization Chamber

C.2.1

Kusetshenziswa amathuluzi okurekhoda izinga lokushisa athobela Isithasiselo B, izinga lokushisa lezindawo ezimele endaweni esebenzisekayo yegumbi le-eo sterilization kufanele kurekhodwe.

C.2.2

Okungenani kufanele kube namaphoyinti okulinganisa angu-6 avumelanayo. Izibulala-magciwane ezinenani eliphelele eliphakathi kuka-300 L no-8000 L, okungenani izilinganiso eziyi-12 ngesikhathi esisodwa kufanele zenziwe; kuwo wonke ama-4000 L angeziwe, amaphoyinti okulinganisa angu-6 engeziwe kufanele angezwe. Qaphela ukuthi indawo yokulinganisa kufanele ihlanganise izifunda ngaphakathi kwendawo yegumbi le-Ethylene oxide sterilization lapho ukuguquka kwezinga lokushisa kungase kube kukhulu ngokwedlulele (izindawo ezinokushisa okwedlulele okuhlukahlukayo), njengezindawo ezingashisiswanga eduze komnyango wegumbi lokuvala inzalo kanye nezindawo eziseduze nendawo yokujova isitimu.

C.2.3

Ngesikhathi sokuhlolwa, igumbi lokuvala inzalo kufanele lingabi nalutho kodwa lingase libe namathuluzi ayisizayo adingekayo ukuze kufakwe inqubo yokuvala inzalo ye-Ethylene oxide, iminyango yegumbi le-Ethylene oxide sterilization ivaliwe.

C.2.4

Kuwo wonke umjikelezo wokuvala inzalo ye-Ethylene oxide, indawo yesilinganiso sokushisa ngasinye kufanele irekhodwe, ichaze amazinga okushisa ezindaweni ezihlukahlukene ze-eo sterilization chamber.

Qaphela: Lokhu kuhlola kungase kusebenzise amagesi angenabuthi, angashi noma izingxube esikhundleni se-ejenti ebulala amagciwane ejovwe egunjini le-eto sterilization ngesistimu yomjovo we-ethylene oxide (kuhlanganise ne-vaporizer).

UMA UFUNA UKWAZI OKWENGEZIWE Nge-Ethylene Oxide Sterilization

Ucingo:+8619975258603

I-imeyili:hayley@hzbocon.com

Indawo Yendawo: Igumbi 1202, Caitong Zhongxin, Xiasha District, Hangzhou City, Zhejiang Province, China

Iwebhusayithi:hzbocon.com zjbocon.com

Skrolela phezulu