שירותים

השירותים שלנו

פרויקט עיקור EO סוהר

שירותי הסמכה

עיצוב תחנת סטריליזטור

שירות לאחר המכירה

שאלות נפוצות

A. Ethylene oxide is a gas used for sterilization across a very wide range of products — more than 50% of medical devices are sterilized with EO. It can be used on its own or blended with carbon dioxide.

A. • Suited to high-volume sterilization, because EO gas penetrates packaging and long lumens.
• Sterilization after final packaging, which avoids the secondary contamination that repacking causes.
• A low-temperature process, so heat-sensitive materials keep their original properties.
• Low sterilization and maintenance cost.
• Excellent material compatibility.
• Product stays in its sealed final packaging throughout the cycle.
• Validated on roughly 50,000 types of medical device.
• Simple to operate and to monitor.
• Can sterilize products that contain batteries and electronics.
• A long, well-documented safety record.
• Broad-spectrum antimicrobial activity.

A. EO is used wherever heat or moisture would damage the product. The main groups are:/n1. Endoscopes — laryngoscopes, bronchoscopes, oesophagoscopes, cystoscopes and ureteroscopes, mediastinoscopes, thoracoscopes, and fibre-optic gastro-, duodeno-, broncho- and angioscopes.
2. Plastics and rubber — gloves, finger cots, syringes, injection devices, blood collection and infusion sets, urine bags, test tubes, intracranial, venous and arterial catheters, tubing, drains, sponges and liners.
3. Instruments and implants — automated suturing machines, sutures and suture needles, artificial oesophagus, bone, pericardium and vessels, PTFE membranes, artificial lung circuits, pacemakers and leads, drainage and post-operative suction sets, lumbar puncture kits, urinary catheter sets, peritoneal dialysis circuits, thermistors, stethoscopes, medical drills and saws, electrosurgical units, batteries, bone plates and cameras.
4. Anaesthesia and airway — endotracheal tubes, nasal cannulae, tracheostomy tubes, suction catheters, anaesthesia masks, corrugated tubing, breathing bags, closed circuits, ventilator components and nebulisers.
5. Cotton and textile products — gowns, gauze, bandages, cotton wool and similar dressings.

A. Payment is by bank transfer (T/T), with a minimum 30% advance payment. The delivery period is counted from the date the advance is received. Ten days before shipment the seller invites the buyer to the factory for a Factory Acceptance Test (FAT); attendance is the buyer's decision.

A. The chamber and main unit carry a warranty of at least 5 years, the control system 2 years, and other purchased components 1 year.

A. Yes. Once the machine arrives at the customer's plant, our engineers attend site to install it and train the operators.

A. Production and delivery take 60–90 days. After the EO sterilizer is complete, the customer may choose to run a Factory Acceptance Test (FAT) at our works. Installation and commissioning take 15–60 days depending on chamber size; IQ and OQ take about 7 days, and PQ support is available.

A. Of course. We welcome customers to visit the factory and would be glad to meet you in person.

גלול למעלה