Ovo je sterilizator

Rated 5.00 out of 5 based on 4 customer ratings
(6 customer reviews)

Stroj za sterilizaciju etilen oksidom (Eto sterilizator) je razvio i dizajnirao BOCON, s veličinama od 1-128m³?1-36 američkih paleta) (1-44 euro palete) PS: Europska veličina palete (1200 x 800 mm) & Američka veličina palete (1200 x 1000 mm)

Da bismo napravili eto sterilizaciju u optimalnim uvjetima, možemo ponuditi sljedeće usluge: masnoću, SAT, DQ, IQ, OQ i podrška za PQ.

Slijedeći zahtjeve kupaca, možemo dostaviti: preduvjetu, sterilizaciju, komore za omalovažavanje, EO pročišćavanje i EO recikliranje energije.

Kategorija:

BOCON ETO STERILIZER

We offer: FAT, SAT, DQ, IQ, OQ, and support for PQ. Standard compliance: EN 1422, CE, ISO 13485.

Engineering Support

Custom dimensions or automatic conveyor loading systems available.

INQUIRE NOW →

Industrija Eto Sterilizator Crackboy EO Projekt sterilizacije

Projekt ključ u ruke je cjelovit projekt koji je dizajnirao, izgradio i testirao jedan pružatelj usluga. U kontekstu eto sterilizacije, projekt ključ u ruke obično uključuje dizajniranje i izgradnju kompletnog postrojenja za sterilizaciju ETO, uključujući:

* Komora eto sterilizatora

* predgrijan soba

* Prozračna soba

* Pililica  

* Sustav transportera za sterilizaciju

* Obitelj upravljačkog sustava

* Lokalna kontrolna kutija

* itd

Mi smo glavni označeni dobavljač EtO sterilizatora za Medline, kardinal i Medtronic. Medline, kardinal i Medtronic su sve tvrtke Fortune 100, a ormarići za sterilizaciju koje pružamo čini više od 60% njihovih potreba za ukupnom sterilizacijom.

Pored naših partnerstava s globalnim liderima, služimo i kao glavni Sterilizator etilen oksida Dobavljač za allMed, pobjednik i Zhende - tri najveća proizvođača medicinskih proizvoda u Kini. Naša rješenja za sterilizaciju čini više od 90% njihove potrebe za sterilizacijom, dodatno učvršćujući naš položaj kao lider na tržištu.

Bocon Company ima jak R&D tim, a mi ulažemo 2 ~ 3 milijuna RMB u R&D Troškovi svake godine. Imamo 28 patenata, uključujući 3 kineska patenta izuma i 2 patenta američkog izuma. Mnoge tvrtke usredotočuju svoju energiju na prodaju, ali uvijek smo bili posvećeni istraživanju i razvoju proizvoda.

Mogli biste vidjeti našeg katalog znati više o našoj komori.

EtO Sterilizatorski komorni sustav vrata

Obično postoje 3 vrste vrata: sporedna vrata, podizanje vrata i okretna vrata. Nema potrebe za usisavanjem prilikom otvaranja vrata, sustav vrata ima funkciju ispitivanja tlaka.

Pneumatska okretna vrata

Pneumatska klizna vrata

Sveukupno podizanje vrata

  • Izvješće o automatskoj procjeni kvalitete za softver, što je važna funkcija za pomoć operatorima i osoblju za kontrolu kvalitete u brzom procjeni kvalitete proizvodnje i identificiranju problema. Naš softver za sterilizaciju kabineta ima više od 400 ugrađenih funkcija automatske procjene, što gotovo može zadovoljiti kvalitetne automatske potrebe za otkrivanjem i procjenom svih kupaca
  • Vrlo detaljna funkcija praćenja revizije softvera. Konkretno, očituje se s više od 120 funkcija automatskog otkrivanja i predviđanja, a gotovo sve operacije bit će zabilježene u sustavu, što olakšava brzo prepoznavanje uzroka problema i popraviti ih u kasnijoj fazi.
  • Standardizirano sigurnosno MES sučelje, uz pristanak kupca, podaci se mogu automatski prenositi na Cloud Servers ili kupčev vlastiti sigurnosni poslužitelj
  • I još

Naš upravljački sustav prošao je dugoročne stroge revizije kompanija Medline, Cardinal, Medtronic, pobjednika, Zhende i Allmed, te ima najopsežnije funkcije i najbolju stabilnost.

Why Choose BOCON EO Sterilizer?

180 Tons / Month Water saved for 20m³ chamber
(Equipped with Gas-water separator)
RMB 230,000 / Year Electricity saved (100m³ Unit)
Based on China Industrial Power Rates
Gas-water separator Bocon Exclusive
Water-Saving Technology
Central Heating Redundant Dual-pump Stability
for Large-scale Facilities

1. Vacuum Pump Technology

Item BOCON OTHERS
Vacuum Pump Options Dry Screw / Water Ring / Oil Ring (Multiple options available) Usually only Water Ring Pump
Ultimate Vacuum Level Up to -101.27 kPa (Dry Screw Pump) Approx. -90 kPa
Water Consumption With BOCON Gas-water separator: Water replaced once per week Continuous water consumption
Maintenance Low maintenance (Dry pump), No oil emulsification risk Frequent oil change (Oil pump) or limited performance
Deep vacuum capability is essential for removing moisture and oil residues, especially for biological products such as sutures. Japanese manufacturers commonly use dry pumps to shorten aeration time from two days to less than half a day through repeated deep vacuum cycles.

2. Water-Saving Performance

Example: A 5.5 kW water ring pump consumes approximately 20 liters per minute. For a 20m³ sterilizer chamber with 8 vacuum cycles (22 minutes each), total water consumption per cycle reaches 3.52 tons.

With 14 cycles per week, total weekly consumption exceeds 49 tons. After installing BOCON’s exclusive Gas-water separator system, water replacement is required only once per week, saving approximately 45 tons of water per week (approx. 180 tons per month). This is especially valuable in water-scarce regions.

3. Exclusive EG Burner System

Item BOCON OTHERS
Exhaust Treatment Gas + Liquid waste combustion with energy recovery Combustion only (gas) or scrubber only
Energy Recovery High-temperature flue gas heats water for sterilizer use No energy recovery
Liquid Waste Handling Integrated liquid waste combustion Scrubber cannot treat liquid waste

The BOCON EG Burner combines waste liquid treatment and energy recycling. For example, a 100m³ sterilizer system can save approximately RMB 230,000 per year in electricity costs based on China industrial power rates. It also enables catalyst recovery, reducing ongoing operating expenses.

Note: Others currently mostly use combustion-only exhaust treatment, which involves higher risk and needs to stay on at all times, or use scrubbers which cannot handle liquid waste.

4. Centralized Heating System

Item BOCON OTHERS
System Design Centralized heating with dual pump redundancy Single water heating unit
System Stability Backup pump ensures continuous operation System stops if pump fails
Application Suitable for multiple sterilizers in one workshop Individual heating per unit
The BOCON centralized heating system improves operational reliability through dual-pump redundancy, ensures stable operation even during a single pump failure, and significantly reduces heating tube failure rates through an optimized large-capacity water tank design.

Our Partners

Partner 1
Partner 11
Partner 2
Partner 12
Partner 7
Partner 6
Partner 3
Partner 5
Partner 9
Partner 4

Sigurnost naše opreme za sterilizaciju EO

EO je zapaljiva, eksplozivna kemikalija. Njegove karakteristike požara i eksplozije ovise o sustavu. Neki od
Karakteristike za EO/zračne smjese su sljedeće:
• ThimiMumValuecitedFortheLowerflable granica EO zračnih smjesa je 2,6% EO [20].
• Gornja zapaljiva granica obično se navodi da je 100%, jer pod određenim uvjetima čisti EO može nasilno
razgraditi se značajnim oslobađanjem topline u nedostatku zraka ili kisika.
• U skladu s tim, zapaljivi raspon smjesa E-AIR-a iznosi 2,6–100% EO.
• Temperatura autoitinjenja EO u zraku na 14,7 psia je 833 ° F (445 ° C)


Bocon koristi miješane plinske procese i pune procese zaštite nitrida kako bi ga čuvali.

Mješoviti plinski procesi

Potpuni procesi zaštite od nitrida

1.Po
2. Krenite toplo
3. Pred-vakuum
4. ISPITIVANJE
5. Gospodina
6. Stanovanje
7.eo injekcija
8. Injekcija u injekciju2
9.EO Injekcija 3
10.EO stan
11. IT je uklanjanje 2
12.ARIJE PRAVANJA
13.aracija

Frequently Asked Questions

Everything you need to know about BOCON ETO Sterilization technology.

Q1. What is the typical cycle time for an ETO sterilization process?

The entire ETO sterilization cycle usually takes between 12 to 24 hours. This includes critical stages: pre-conditioning (temperature/humidity adjustment), gas injection, exposure, and a lengthy aeration period to safely remove residual EO gas.

Q2. Why choose EO sterilization over Steam sterilization for medical devices?

EO is a low-temperature process (37°C to 55°C), making it ideal for heat-sensitive materials like plastics, electronics, and delicate surgical instruments that would be damaged by the high heat and moisture of steam autoclaves.

Q3. Are BOCON sterilizers compliant with ISO 11135 and EN 1422?

Yes. All BOCON equipment is manufactured to meet ISO 11135 and EN 1422 international standards. We provide full validation documentation support, including FAT, SAT, DQ, IQ, OQ, and assist with your PQ.

Q4. How do you ensure environmental safety regarding EO gas emissions?

BOCON ETO sterilizers can be integrated with our high-efficiency EO Scrubber system. This system uses chemical hydrolysis to neutralize 99.9% of ethylene oxide gas before it is exhausted, ensuring compliance with EPA and local environmental regulations.

Q5. What safety features are integrated into the Siemens PLC control system?

Our systems include explosion-proof components, real-time pressure and temperature monitoring, gas leak detection, and automatic interlocking doors. The Siemens PLC ensures precise control and records all cycle data for traceability.

Have more technical questions?

Contact our engineers for a free consultation →

6 reviews for Ovo je sterilizator

  1. Rated 5 out of 5

    pogubiti

    Sjajan eto sterilizator,

  2. Rated 5 out of 5

    15657615935a

    Hvala vam puno na visokokvalitetnim proizvodima i uslugama koje pruža Bocon. Dobrodošli u posjet mojoj ETO radionici za sterilizaciju u bilo koje vrijeme.”

  3. Rated 5 out of 5

    Glen

    Proizvodi i usluge su izvrsni!
    Rado ću preporučiti ove dobre EO sterilizatore svojim prijateljima.
    Dobrodošli prijatelji iz Indonezije da me posavjetujete.

  4. Rated 5 out of 5

    alex

    We purchased a 30m³ ETO sterilization system from BOCON for our new facility. Their engineering team provided exceptional support during the DQ, IQ, and OQ phases. The equipment fully complies with ISO 11135 standards, and we passed our audit without any issues. Highly professional!

  5. CEO, Medical Packaging Solutions (Thailand)

    Excellent communication and after-sales service. Even with the time difference, BOCON’s technical support team responds quickly to our inquiries. The training they provided to our staff was thorough and very helpful.

  6. Technical Engineer, Sterilization Services (India)

    We have been running BOCON ETO machines for over three years now. The uptime is impressive, and maintenance is straightforward. Compared to European brands, BOCON offers the best balance of advanced technology and cost-efficiency.——

Add a review

Vaša adresa e -pošte neće biti objavljena. Označena su potrebna polja *

Pomaknite se na vrh