Preparatory Work Before eto Sterilization
Appearance Inspection: Check the main unit, control rack, and electrical control cabinet for any damage on the surface.
Preparatory Work Before eto Sterilization Цааш унших
Appearance Inspection: Check the main unit, control rack, and electrical control cabinet for any damage on the surface.
Preparatory Work Before eto Sterilization Цааш унших
Start cycle phase(Select parameters/sterilization recipe) Serial number Potentially risky content Risk assessment under existing process conditions Risk assessment of the
EO sterilization equipment and process characteristic patterns and effect analysis Цааш унших
9.1 During ETO Sterilization, operators are not allowed to leave the operating area and must continuously observe the ETO Sterilization process. If any abnormal phenomena occur, the machine must be immediately shut down, and the power supply should be cut off for inspection.
ETO ариутгагч төхөөрөмжийн засвар үйлчилгээний гарын авлага Цааш унших
For the purposes of this document, the following terms and definitions apply in ethylene oxide sterilization 3.1 Aeration part of
Это хийн ариутгалын нэр томъёо, тодорхойлолт Цааш унших
Appearance Inspection: Check for any damage on the surfaces of the main machine, control rack, and electrical control cabinet.
Power Supply Check: Ensure the power supply meets the requirements and check the rotation direction of the water pump and vacuum pump.
Turn on the power and observe whether the instrument display values are normal; otherwise, cut off the power, inspect and repair before restarting.
Pipeline Inspection: Check for leaks in the water supply, vacuum, and medication delivery pipelines, and ensure all valves are in standby mode; adjust if necessary.
Ариутгалын өмнөх бэлтгэл ажил Цааш унших
2.1.1 The overall shape should be precise, with smooth, clean surfaces and uniform color. There should be no burrs, sharp edges, cracks, visible scratches, or unevenness.
2.1.2 All external text, graphics, and symbols must be printed clearly, with precise and durable markings.
2.1.3 Fasteners must be securely installed. All control switches and adjustment knobs (or buttons) should operate smoothly and reliably without obstructions.
Request For Eto Gas Sterilizer Manufacturer Цааш унших
Within a certain range of gas concentration, the higher the concentration, the better theEO Gas Sterilization effect; beyond 1000 mg/L, the improvement in sterilization effect is not significant.
EO хийн ариутгалын процесст нөлөөлөх хүчин зүйлс Цааш унших
eto sterilization technologies vs others: Advantages and Disadvantages Sterilization is a critical process in infection control, ensuring that medical instruments
ETO ариутгалыг бусад аргуудтай харьцуулах Цааш унших
ETO стеро-сасизмын температурын хүрээ нь 30-60 ° C-ийн хооронд байх ёстой. Ариум садан нь халаалт, чийгшүүлэх системийн температур, чийгшлийн дотоод талыг арилгахыг баталгаажуулахыг зөвлөж байна.
ETO ариутгалын камерын туршилт Цааш унших
The purpose of routine monitoring and control of EO (Ethylene Oxide) sterilization is to demonstrate that the confirmed and specified sterilization process has been applied to the product. Data from each sterilization cycle should be recorded and retained to prove that the confirmed sterilization process specifications have been met. This should include at least the following content:
Этилений ислийн ариутгалыг тогтмол хянах, хянах, суллах Цааш унших