ETO esterilizador t.u.m iik' chokoj

Advanced Air-Jacketed Heating Technology

One of Bocon’s core engineering breakthroughs is our signature Air-Jacketed Heating System. Unlike traditional hot water jacket designs, Bocon utilizes a sophisticated hot air circulation system to maintain chamber temperature. This innovative approach offers a superior alternative to conventional systems, delivering significant advantages in operational safety, thermal precision, and long-term maintenance efficiency. By choosing air over water, we provide our clients with a cleaner, more reliable, and energy-efficient sterilization environment.

BOCON Hot Air Eto Sterilizer Specifications

Kúumplimiento: EN 1422, CE, ISO 13485 Support: FAT, SAT, DQ, IQ, OQ, PQ

Engineering Support

Dimensiones personalizadas yéetel sistemas transportadores automatizados táan disponibles ti' le j-na'akij.

K'ÁAT BEJLA'E' →

Bocon chaqueta iik' chokoj ETO esterilizador VS chaqueta ja' xíiw EO esterilizador

Característica / Especificación t.u.m chaqueta iik' chokoj Bocon T.u.m chaqueta ja' xíiw
Eficiencia ti' calefacción Ka'anal: Uniformemente mantas cámara yéetel joolnajo'ob Jun. Inferior: Transferencia ooxoj indirecta yo'osal chúumuk ja'.
U jantbil energía Optimizado: Chéen ku k'íintik u kuuch le producto yéetel le iik'o'. Ka'anal: Ya'ab energía ku sa'atal uti'al u p'áatal u temperatura le ja'o'.
K'iinil u k'íintik (tak 21°C) séeba'an: ma' chukik 3 horas. Chaambel: K'a'abet u k'íintik ya'abkach ja' táanile'.
Ba'ax k'a'abéet uti'al u kanáanta'al Bajo: T.u.m tikin, ma' aditivos wa bombas ja'. Ka'anal: Mantats' monitoreo ti' le corrosión yéetel le reemplazos sello.
riesgo ti' corrosión Cero: ku xu'ulsik le óxido yéetel le acumulación mineral. High: Prone to scaling and internal corrosion.
Leak Impact Minor: Non-critical for performance and easily repaired. Critical: Causes thermal instability and safety hazards.
Weight & Logistics Light: Easier rigging, installation, and lower shipping costs. Heavy: Complex structural requirements for installation.

Why Choose BOCON EO Sterilizer?

Technological Excellence vs. Conventional Industry Standards.

180 Tons / Month Water saved for 20m³ chamber
(Equipped with Gas-water separator)
RMB 230,000 / Year Electricity saved (100m³ Unit)
Based on China Industrial Power Rates
Air Jacket System Bocon Exclusive
Maintenance-free Hot Air Tech
Centralized Heating Redundant Dual-pump Stability
for Multi-unit Layouts

1. Vacuum Pump Technology

Item BOCON OTHERS
Vacuum Pump Options Dry Screw / Water Ring / Oil Ring (Multiple options available) Usually only Water Ring Pump
Ultimate Vacuum Level Up to -101.27 kPa (Dry Screw Pump) Approx. -90 kPa
Water Consumption With BOCON Gas-water separator: Water replaced once per week Continuous water consumption
Maintenance Low maintenance (Dry pump), No oil emulsification risk Frequent oil change (Oil pump) or limited performance

2. Water-Saving Performance

3. Diseño u cámara le esterilizador

Item BOCON OTHERS
Bin yano'ob cámara Chaqueta ja' / Chaqueta iik' (t.u.m iik' chokoj) Chéen chaqueta ja'
Velocidad u k'íintik séeba'an k'íintik yéetel síis (chaqueta iik') Transición temperatura asab chaanbelil
Maintenance Mina'an riesgo u fugas, chowak kuxtal útil (chaqueta iik') Riesgo u fugas ja' ichil le k'iin
K'a'abéet kúuchil Instalación compacta, conveniente utia'al u diseño ya'ab k'oja'ano'ob unidades (chaqueta iik') asab nojoch u yooko'ob

4. T.u.m quemador EG exclusivo

Item BOCON OTHERS
Ts'a'akal u escape Combustión u residuos gas + líquido yéetel recuperación energía Chéen combustión (gas) wa chéen fregadora
Recuperación u energía Le gas combustible u ka'anal temperatura ku k'íintik ja' uti'al u búukinta'al esterilizador Ma' u ka'a suut energía
U meyajta'al residuos líquidos Combustión integrada ti' residuos líquidos Le fregador ma' je'el u páajtal u k'aax u residuos líquidos

5. Centralized Heating System

Item BOCON OTHERS
System Design Centralized heating with dual pump redundancy Single water heating unit
System Stability Backup pump ensures continuous operation System stops if pump fails
Application Suitable for multiple sterilizers in one workshop Individual heating per unit

Especificaciones técnicas completas yéetel propiedades

Detalles u t.u.m esterilizador ETO iik' chokoj BOCON

Categoría de características Especificación técnica
ESTÁNDARES YÉETEL ACCESO FÍSICO
Normas u diseño le yaan EN1422, ISO11135-2014
Configuración joolnajo' 2 joolnajo'ob; Sello u traducción neumática (Predeterminado); Ma' k'a'abéet: Rotativo wa Lifting
SISTEMA TI' KA'ANSAJ YÉETEL INTEGRIDAD DATOS
Modo u kaambalil yo'osal le yaan Soft Manual & Full-Automatic
Grabación de datos Modo intervalo yéetel modo desencadenado u advertencia; Grabación u curva continua
Ciclo u kuxtal u almacenamiento datos 10 ja'abo'ob (almacenamiento seguro ti' HDD)
U meyajta'al datos Software u datos u monitoreo u PC yéetel esterilización especializada
SENSORES YÉETEL PRECISIÓN
Temp Control Precision Inside: ±3°C | Wall: ±5°C (Res: 0.1°C)
Pressure Management Range: -100 to +150Kpa; Res: 0.1Kpa; Resistance: up to 80KPa (Standard)
Vacuum Performance < 30 minutes (0 to -90KPa); Continuous/Stepping modes
Humidity Performance 0-100%RH (non-condensing); Resolution: 0.1%RH
AUTOMATION & SAFETY CONNECTORS
Automatic Detection Cabinet water volume, Steam pressure, and Vacuum pump monitoring
Safety Alerts Real-time display & warning for insufficient steam or pressure
System Protection Nitrogen protection (Optional/Auto); Tail gas treatment (Auto-control)
Exhaust Control In-door and Out-door air exhausting with automatic valve control
GAS RECIPES & PROCESS
Supported Gas Recipes Mixed Gas (CO2/EO mixtures: 70/30, 20/80, 10/90) and Pure EO (with N2)
Time Management 0-99 hours; Resolution: 1 min
Customized solutions for high-pressure chambers (>80KPa) and specific gas concentrations are available.

Technical FAQ

Expert insights into Bocon EtO Sterilization Hot Air Circulation Systems

EtO sterilization depends on the "Big Four" parameters: Gas concentration, Humidity, Time, and Temperature. Bocon's Hot Air System ensures that heat and moisture are distributed uniformly throughout the entire chamber load. This high-efficiency circulation eliminates cold spots and ensures that the EtO gas can penetrate dense medical device packaging effectively, regardless of their position in the sterilization chamber.
Our systems are engineered for high-precision thermal stability. We typically achieve a uniformidad u temperatura u ±1°C wa ma'alob ichil u volumen le cámara. Le nivel kaambalil yo'osal u gestiona yo'osal avanzado Controladores PLC Siemens yéetel sensores RTD u ka'anal precisión, asegurando u le tuukula' permanece ichil le rango validado requerido tumen le estándares ISO 11135.
Tuméen EtO jach inflamable yéetel explosivo, Bocon utiliza Ventiladores a prueba de explosiones certificados tumen ATEX wa IECEx yéetel elementos u calefacción especializados. Le hardwareo' beeta'an uti'al ma' u yantal chispa. Beyxan, le yaan táan enclavado yéetel le software kanik utia'al u asegurar ti' u le tuukula' calefacción chéen opera ken le concentraciones gas táan ichil niveles seguros, tu menudo implicando dilución nitrógeno bey juntúul cojín ti' seguridad.
Jach beyo. K ts'aik soluciones modulares ku bino'ob tak 1m3 kúuchilo'ob laboratorio u 100m3 cámaras industriales u nojoch escala. K calculamos le kuuch térmica k'a'abeto'ob yéetel le tasas intercambio iik' basadas ti' u densidad específica u producto yéetel volumen cámara utia'al u asegurar le rendimiento óptimo utia'al u ciclos esterilización.
Utia'al u mantener le limpieza u grado ts'aak yéetel resistir le corrosión ti' le gases esterilización, Bocon meyajtiko'ob ka'anal calidad SS304 wa SS316L acero inoxidable uti'al tuláakal le conductos internos, u palas le ventilador yéetel le superficies cámara. Le je'ela' ku yáantik u xáantal máak yéetel ku jets'ik je'el ba'alak contaminación tumen partículas ti' le nu'ukulo'ob ts'aako'ob ku meyajta'alo'obo'.
Yes. All Bocon systems are equipped with advanced data acquisition capabilities. Every parameter—including temperature, pressure, and fan speed—is recorded in real-time. Our software is designed to be compliant with FDA 21 CFR Part 11, providing the electronic records and audit trails necessary for international regulatory inspections.

K socios

Socio 1
Socio 11
Socio 2
Socio 12
Socio 7
Socio 6
Socio 3
Socio 5
Socio 9
Socio 4

Reseñas

Mina'an mix jump'éel revisión láayli'.

Beet u yáax máak u xak'altik “ETO esterilizador t.u.m iik' chokoj”

U dirección correo electrónico ma' yaan publicada. Le sikte obligatorios táan marcados *

Desplazar a ti' ka'anal