Qhov no yog sterilizer

Rated 5.00 Nws tawm ntawm 5 raws li 4 cov neeg siv khoom ntsuas
(6 neeg xyuas)

Lub tshuab ethylene oxide sterilizer (Eto sterilizer) tau tsim thiab tsim los ntawm BOCON, nrog qhov ntau thiab tsawg ntawm 1-128m³?1-36 US pallets) (1-44 Euro pallets) PS: European Pallet Loj (1200 x 800 mm) & US Pallet Loj (1200 x 1000 mm)

Txhawm rau ua ETO kom tsis muaj menyuam hauv qhov zoo tshaj plaws, peb tuaj yeem muab cov kev pabcuam hauv qab no: FAT, SAT, DQ, IQ, OQ, thiab kev txhawb nqa rau PQ.

Ua raws li cov neeg siv khoom thov, peb tuaj yeem muab: Kev Kho Mob Ua Ntej, Sterilization, Degassing Chambers, EO Scrubber, thiab EO Energy Recycling.

BOCON ETO STERILIZER

Peb muab: FAT, SAT, DQ, IQ, OQ, thiab kev txhawb nqa rau PQ. Standard compliance: EN 1422, CE, ISO 13485.

Kev them nyiaj yug Engineering

Kev cai qhov ntev lossis tsis siv neeg conveyor loading tshuab muaj.

NUG NUG →

Kev lag luam ETO Sterilizer Turnkey EO Sterilization Project

Ib qhov project turnkey yog ib qhov project tiav uas yog tsim, tsim, thiab sim los ntawm ib tus kws kho mob. Nyob rau hauv cov ntsiab lus ntawm ETO sterilization, ib txoj haujlwm turnkey feem ntau suav nrog kev tsim thiab tsim kom muaj ETO kom tsis muaj menyuam, suav nrog:

* ETO Sterilizer Chamber

* chav preheating

* Chav Aeration

* Scrubber  

* Sterilization conveyor system

* tswj system txee

* hauv zos tswj lub thawv

* lwm yam

Peb yog lub chaw tsim khoom eto sterilizer rau Medline, Cardinal, thiab Medtronic. Medline, Cardinal, thiab Medtronic yog tag nrho cov tuam txhab Fortune 100, thiab cov khoom ua kom tsis muaj menyuam uas peb muab nyiaj ntau dua 60% ntawm lawv cov khoom siv kom tsis muaj menyuam tag nrho.

Ntxiv nrog rau peb txoj kev koom tes nrog cov thawj coj thoob ntiaj teb, peb kuj ua haujlwm tseem ceeb ethylene oxide sterilizer tus neeg muag khoom rau ALLMED, WINNER, thiab ZHENDE - peb cov khoom siv kho mob loj tshaj plaws hauv Suav teb. Peb cov kev daws teeb meem kom tsis muaj menyuam muaj ntau dua 90% ntawm lawv cov khoom siv kom tsis muaj menyuam, ntxiv dag zog rau peb txoj haujlwm ua tus thawj coj ua lag luam.

BOCON tuam txhab muaj zog R&D pab neeg, thiab peb nqis peev 2 ~ 3 lab RMB hauv R&D cov nuj nqis txhua xyoo. Peb muaj 28 patents, suav nrog 3 Suav invention patents thiab 2 American invention patents. Ntau lub tuam txhab tsom lawv lub zog ntawm kev muag khoom, tab sis peb ib txwm mob siab rau kev tshawb fawb thiab kev tsim khoom.

Koj tuaj yeem saib peb catalog kom paub ntau ntxiv txog peb Chamber.

ETO Sterilizer Chamber Qhov Rooj System

Feem ntau muaj 3 hom qhov rooj: lub qhov rooj, lub qhov rooj thiab lub qhov rooj. Tsis tas yuav tsum nqus thaum qhib lub qhov rooj, qhov rooj kaw lus muaj qhov ntsuas siab ua haujlwm.

Pneumatic Revolving Qhov Rooj

Pneumatic zawv zawg qhov rooj

Zuag qhia tag nrho Lifting Qhov Rooj

  • Daim ntawv tshaj tawm kev soj ntsuam zoo tsis siv neeg rau software, uas yog lub luag haujlwm tseem ceeb los pab cov neeg ua haujlwm thiab cov neeg ua haujlwm tswj xyuas kom zoo hauv kev soj ntsuam sai sai thiab txheeb xyuas cov teeb meem. Peb sterilization txee software muaj ntau tshaj 400 built-in tsis siv neeg kev soj ntsuam kev ua haujlwm, uas yuav luag ua tau raws li qhov zoo tsis siv neeg tshawb nrhiav thiab kev ntsuam xyuas xav tau ntawm txhua tus neeg siv khoom.
  • Cov ncauj lus kom ntxaws heev software tshawb nrhiav kev ua haujlwm. Tshwj xeeb tshaj yog, nws tau tshwm sim los ntawm ntau tshaj 120 qhov tsis siv neeg tshawb nrhiav thiab kev twv ua ntej lub tswb ua haujlwm, thiab yuav luag txhua qhov haujlwm yuav raug kaw hauv lub kaw lus, ua rau nws yooj yim los txheeb xyuas lub hauv paus ntawm cov teeb meem thiab kho lawv nyob rau theem tom ntej.
  • Standardized backend MES interface, nrog rau cov neeg siv khoom pom zoo, cov ntaub ntawv tuaj yeem raug xa mus rau huab servers lossis tus neeg siv khoom tus kheej thaub qab.
  • Thiab ntxiv

Peb cov kev tswj hwm tau dhau mus ntev kev soj ntsuam nruj heev los ntawm Medline, Cardinal, Medtronic, WINNER, ZHENDE, thiab ALLMED tuam txhab, thiab muaj cov haujlwm zoo tshaj plaws thiab kev ruaj ntseg zoo tshaj plaws.

Vim li cas thiaj xaiv BOCON EO Sterilizer?

180 Tons / hli Dej txuag rau 20m³ chamber
(Nruab nrog Gas-dej separator)
RMB 230,000 / Xyoo Kev txuag hluav taws xob (100m³ Unit)
Raws li Tuam Tshoj Industrial Fais Fab Tus Nqi
Gas-dej separator Bocon Exclusive
Dej-txuag Technology
Central Cua sov Redundant Dual-pump Stability
rau Cov Khoom Siv Loj Loj

1. Lub tshuab nqus tsev twj tshuab

Yam khoom BOCON Lwm tus
Lub tshuab nqus tsev twj Options Ntsia Hlau Qhuav / Dej Nplhaib / Roj Nplhaib (ntau txoj kev xaiv muaj) Feem ntau tsuas yog Dej Ring Pump
Qhov kawg Vacuum Level Mus txog -101.27 kPa (Tsev Ntsia Hlau Twj) Kwv yees li. -90 kPa
Kev siv dej With BOCON Gas-water separator: Water replaced once per week Kev siv dej tsis tu ncua
Kev tu Tsawg txij nkawm (Lub twj tso kua mis qhuav), Tsis muaj roj emulsification txaus ntshai Kev hloov roj ntau zaus (Oil twj tso kua mis) lossis kev ua haujlwm tsawg
Lub tshuab nqus tsev sib sib zog nqus yog qhov tseem ceeb rau kev tshem tawm cov dej noo thiab cov roj seem, tshwj xeeb tshaj yog rau cov khoom siv roj ntsha xws li sutures. Cov tuam txhab lag luam Nyij Pooj feem ntau siv cov twj qhuav kom luv lub sij hawm aeration los ntawm ob hnub mus rau tsawg tshaj li ib nrab hnub los ntawm kev rov ua dua lub tshuab nqus tsev sib sib zog nqus.

2. Kev txuag dej

Piv txwv li: A 5.5 kW dej nplhaib twj siv kwv yees li 20 litres ib feeb. Rau 20m³ sterilizer chamber nrog 8 lub tshuab nqus tsev vacuum (22 feeb txhua), tag nrho cov dej siv ib lub voj voog mus txog 3.52 tons.

Nrog 14 lub voj voog ib lub lim tiam, tag nrho cov khoom noj txhua lub lim tiam tau tshaj 49 tons. Tom qab kev txhim kho BOCON's Exclusive Gas-dej Separator system, hloov dej tsuas yog ib zaug ib lub lim tiam, txuag kwv yees li 45 tons of water per week (approx. 180 tons per month). This is especially valuable in water-scarce regions.

3. Exclusive EG Burner System

Yam khoom BOCON Lwm tus
Kev kho cua sov Gas + Liquid combustion nrog lub zog rov qab combustion xwb (gas) los yog scrubber xwb
Lub zog rov qab los High-temperature flue gas heats dej rau sterilizer siv Tsis muaj zog rov qab
Kev Siv Dej Siv Dej Integrated kua khib nyiab combustion Scrubber tsis tuaj yeem kho cov dej khib nyiab

Cov BOCON EG Burner muab kev kho cov kua dej pov tseg thiab siv zog rov ua dua tshiab. Piv txwv li, 100m³ sterilizer system tuaj yeem txuag tau kwv yees li RMB 230,000 ib xyoo nyob rau hauv cov nqi hluav taws xob raws li Tuam Tshoj industrial fais fab nqi. Nws tseem ua kom cov catalyst rov qab, txo cov nqi khiav haujlwm tsis tu ncua.

Nco tseg: Lwm tus tam sim no feem ntau siv cov tshuaj tua hluav taws nkaus xwb, uas muaj kev pheej hmoo siab dua thiab xav tau nyob rau txhua lub sijhawm, lossis siv cov tshuaj txhuam hniav uas tsis tuaj yeem ua kua dej pov tseg.

4. Centralized cua sov System

Yam khoom BOCON Lwm tus
Qhov System Design Centralized cua sov nrog dual twj tso kua mis redundancy Ib chav dej cua sov
Qhov System Stability Thaub qab lub twj tso kua mis kom ua haujlwm tsis tu ncua Lub kaw lus nres yog tias lub twj tso kua mis tsis ua haujlwm
Daim ntawv thov Haum rau ntau yam sterilizers hauv ib lub rhiav Cov cua kub ntawm tus kheej rau ib chav tsev
Cov BOCON centralized cua sov system txhim kho kev lag luam kev ntseeg siab los ntawm kev siv dual-tswj redundancy, ua kom muaj kev ruaj ntseg txawm tias thaum lub twj tso kua mis tsis ua haujlwm, thiab txo cov cua sov raj tsis ua hauj lwm los ntawm kev ua kom zoo tshaj qhov muaj peev xwm loj dej tank tsim.

Peb Cov Neeg Koom Tes

Tus khub 1
Partner 11
Tus khub 2
Partner 12
Tus khub 7
Tus khub 6
Tus khub 3
Tus khub 5
Tus khub 9
Tus khub 4

Kev nyab xeeb ntawm peb cov khoom siv EO sterilization

EO yog cov tshuaj tua hluav taws, tawg. Nws cov yam ntxwv hluav taws kub thiab tawg yog qhov nyob ntawm qhov system. Qee qhov
Cov yam ntxwv rau EO / cua sib tov yog raws li nram no:
• Tus nqi qis tshaj plaws rau qhov kev txwv qis dua ntawm EO cua sib tov yog 2.6% EO[20].
• Qhov txwv tsis pub muaj hluav taws kub yog feem ntau hais tias yog 100% vim tias nyob rau hauv qee qhov xwm txheej ntshiab EO tuaj yeem ua phem
decompose nrog ib qho tseem ceeb tso tawm ntawm tshav kub thaum tsis muaj cua lossis oxygen.
• Raws li, cov nplaim taws ntau ntawm EO-cua sib tov yog 2.6-100% EO.
• autoignition kub ntawm EO hauv huab cua ntawm 14.7 psia yog 833 ° F (445 ° C)


Bocon siv cov txheej txheem roj sib xyaw thiab cov txheej txheem tiv thaiv Nitride tag nrho kom nws muaj kev nyab xeeb.

Cov txheej txheem roj sib xyaw

Cov txheej txheem tiv thaiv nitride tag nrho

1. Cua sov
2. Ua kom sov
3. Lub tshuab nqus tsev ua ntej
4.Leak xeem
5.Humiditying
6.Vumidity tsev
7.EO txhaj
8. EO txhaj 2
9.EO txhaj 3
10.EO tsev
11.EO tshem tawm 2
12. Cua ntxhua
13.Aeration

Cov lus nug nquag

Txhua yam koj xav paub txog BOCON ETO Sterilization tshuab.

Q1. Lub sij hawm voj voog ib txwm rau ETO sterilization txheej txheem yog dab tsi?

Tag nrho ETO sterilization voj voog feem ntau yuav siv sij hawm nruab nrab ntawm 12 mus rau 24 teev. Qhov no suav nrog cov theem tseem ceeb: pre-conditioning (kub / humidity adjustment), gas txhaj, raug, thiab ib tug ntev aeration lub sij hawm kom xyuam xim tshem tawm cov seem EO roj.

Q2. Vim li cas thiaj xaiv EO sterilization dua Steam sterilization rau cov khoom siv kho mob?

EO yog a cov txheej txheem kub qis (37 ° C mus rau 55 ° C), ua rau nws zoo tagnrho rau cov ntaub ntawv kub-rhiab zoo li cov yas, hluav taws xob, thiab cov cuab yeej phais mob uas yuav raug puas los ntawm cov cua kub thiab noo noo ntawm chav autoclaves.

Q3. Puas yog BOCON sterilizers ua raws li ISO 11135 thiab EN 1422?

Yog lawm. Tag nrho cov cuab yeej BOCON yog tsim los ua kom tau raws ISO 11135 thiab EN 1422 cov qauv thoob ntiaj teb. Peb muab kev txhawb nqa cov ntaub ntawv pov thawj tag nrho, suav nrog FAT, SAT, DQ, IQ, OQ, thiab pab nrog koj PQ.

Q4. Koj ua li cas kom muaj kev nyab xeeb ib puag ncig txog EO roj emissions?

BOCON ETO sterilizers tuaj yeem ua ke nrog peb cov kev ua haujlwm siab EO Scrubber system. Cov txheej txheem no siv cov tshuaj hydrolysis los ua kom tsis muaj zog 99.9% ntawm cov roj ethylene oxide ua ntej nws tag, ua kom muaj kev ua raws li EPA thiab cov kev cai hauv cheeb tsam.

Q5. Dab tsi kev nyab xeeb nta tau muab tso rau hauv Siemens PLC tswj qhov system?

Peb cov tshuab suav nrog cov khoom tawg-pov thawj, lub sijhawm ntsuas lub sijhawm thiab ntsuas qhov kub thiab txias, ntsuas cov pa xau, thiab tsis siv neeg kaw qhov rooj. Cov Siemens PLC xyuas kom meej tswj thiab sau tag nrho cov ntaub ntawv voj voog rau traceability.

6 tshuaj xyuas rau Qhov no yog sterilizer

  1. Rated 5 ntawm 5

    rebort

    zoo heev eto sterilizer,

  2. Rated 5 ntawm 5

    15657615935 a

    Ua tsaug ntau rau cov khoom lag luam zoo thiab cov kev pabcuam muab los ntawm Bocon. Txais tos tuaj xyuas kuv lub rooj cob qhia ETO kom tsis muaj menyuam txhua lub sijhawm. "

  3. Rated 5 ntawm 5

    Lub ntsej muag

    Cov khoom lag luam thiab cov kev pabcuam zoo tshaj!
    Kuv zoo siab tau pom zoo cov o s sterilizers rau kuv cov phooj ywg.
    Txais tos cov phooj ywg los ntawm Indonesia los sab laj kuv.

  4. Rated 5 ntawm 5

    alex ua

    Peb yuav 30m³ ETO sterilization system los ntawm BOCON rau peb qhov chaw tshiab. Lawv pab pawg engineering tau muab kev txhawb nqa tshwj xeeb thaum lub sijhawm DQ, IQ, thiab OQ theem. Cov cuab yeej ua tau raws li ISO 11135 tus qauv, thiab peb tau dhau los ntawm peb qhov kev tshuaj xyuas yam tsis muaj teeb meem. Cov kws tshaj lij!

  5. CEO, Medical Packaging Solutions (Thailand)

    Kev sib txuas lus zoo heev thiab kev pab cuam tom qab muag. Txawm hais tias lub sijhawm sib txawv, BOCON pab pawg txhawb nqa kev teb sai rau peb cov lus nug. Kev cob qhia lawv muab rau peb cov neeg ua haujlwm tau zoo thiab pab tau zoo heev.

  6. Technical Engineer, Sterilization Services (India)

    Peb tau khiav BOCON ETO tshuab tau ntau tshaj peb xyoos tam sim no. Lub sijhawm uptime yog impressive, thiab kev saib xyuas yog ncaj nraim. Piv nrog rau European hom, BOCON muaj qhov zoo tshaj plaws tshuav nyiaj li cas ntawm cov cuab yeej siv siab heev thiab kev ua haujlwm tau zoo.” ——

Ntxiv kev tshuaj xyuas

Koj email chaw nyob yuav tsis raug luam tawm. Cov teb uas yuav tsum tau muaj yog cim *

Scroll rau sab saum toj