Hospital / Laboratory ETO Sterilizer

Ka whakamahia te hohipera eto sterilizer me te Laboratory eto sterilizer ki te whakahoromata i nga taputapu i roto i te rua ki te hau ethylene oxide.

Kāwai:

Ko ta tatou hohipera eto sterilizer sterilizer he otinga tino whai hua ma te whakamahi i te Ethylene Oxide (ETO), tetahi o nga tikanga tino whakamahia mo te whakahoroi i nga taputapu rongoa me nga taonga. Ka tukuna ano e matou ahumahi eto sterilizer

Tawhā taketake o te hōhipera eto sterilizer me Laboratory eto sterilizer

Whakaata Whakaata Whakaahua

Te whare taiwhanga_Hohipera_ETO_sterilizer
Hospital / Laboratory ETO Sterilizer

Āhuatanga o te hōhipera eto sterilizer

A, Whakanuia

To tatou Hospital / Laboratory ETO Sterilizer te whakamahi i te whakakorikori pehanga kino, te horoi i te pehanga kino, te tango i nga toenga pehanga kino, te tukanga katoa o te pehanga kino hei whakarite i te haumaru!

This hospitel eto sterilizer belongs to class B sterilizer, the sterilization temperature can be adjusted in 30℃~55℃. Sterilization, cleaning and residue removal processes, the sterilizer always maintains a relative negative pressure to ensure that ethylene oxide does not leak.

Even if leakage occurs, the control system will automatically detect the leakage, and automatically abort the sterilization process to send an alarm, and automatically discharge the ethylene oxide gas.

B、Residue removal and aeration

When the hospital eto sterilizer sterilization process reaches the end of the cleaning process, it automatically enters the residue removal (to fully ensure that the EO residue of the sterilized articles is minimized).

C、Continuous temperature monitoring

=Sterilization stage temperature is maintained within the selected temperature ± 3 ℃, once the temperature sensor detects a deviation from the predetermined temperature of 3 ℃, then the over-temperature protection device is automatically activated, and the text prompts the temperature abnormality and alarm, and interrupt the heating.

D、Humidity control

The humidity sensor is open and displayed throughout the sterilization process. According to the set humidity value, humidification is uniformly applied several times to ensure the right humidity level.

F、Automatically control of puncturing EO gas cartridge

Only when the dosing process is entered normally will the system automatically activate the dosing unit, puncturing the EO gas cartridge and releasing the ethylene oxide gas.

G、Sterilization process status display

Located in front of the liquid crystal display real-time continuous display of the sterilization process status. (e.g. temperature, humidity, pressure, time, sterilization process, etc.)

Implementation standard of hospital eto sterilizer

Our hospitel eto sterilizer use following standards

YY0503-2016 Ethylene Oxide Sterilizer

GB4793.1-2007 Safety requirements for measuring, controlling and

laboratory electrical equipment (Part I: General Requirements)

GB18279-2000 Confirmation and routine control of ethylene oxide sterilization of medical devices

GB/T18268.1 Nga whakaritenga hototahi hiko mo nga taputapu hiko mo te ine, te whakahaere me te whakamahi taiwhanga

GB 4793.8-2008 Nga whakaritenga haumaru mo nga taputapu hiko mo te ine, te whakahaere, me te whakamahi taiwhanga – Wāhanga 2-042: Nga whakaritenga motuhake mo te maimoatanga o nga taonga rongoa me nga hau paitini me nga pehanga pehanga me nga whakamaarama mo te whakamahi taiwhanga.

eo pounamu hau

Tikiake BOCON Te whare hōhipera EtO Sterilizer Catalog

rārangi o te hōhipera
rārangi o te hōhipera

Ko o maatau hoa

hoa 1
hoa 11
hoa 2
hoa 12
hoa 7
hoa 6
hoa 3
hoa 5
hoa 9
hoa 4

Arotake

Kaore ano he arotake.

Waiho te tuatahi ki te arotake "Hospital / Laboratory ETO Sterilizer”

Kaore e whakaputaina to wahitau imeera. Kua tohua nga mara e hiahiatia ana *

Panuku ki runga