A. Ethylene oxide is a gas used for sterilization across a very wide range of products — more than 50% of medical devices are sterilized with EO. It can be used on its own or blended with carbon dioxide.
A. • Suited to high-volume sterilization, because EO gas penetrates packaging and long lumens.
• Sterilization after final packaging, which avoids the secondary contamination that repacking causes.
• Un proces la temperatură scăzută, astfel încât materialele termosensibile își păstrează proprietățile originale.
• Costuri reduse de sterilizare și întreținere.
• Compatibilitate excelentă cu materialele.
• Produsul rămâne în ambalajul final sigilat pe tot parcursul ciclului.
• Validat pe aproximativ 50.000 de tipuri de dispozitive medicale.
• Simplu de utilizat și de monitorizat.
• Poate steriliza produsele care conțin baterii și electronice.
• Un dosar de siguranță lung, bine documentat.
• Activitate antimicrobiană cu spectru larg.
A. EO este utilizat oriunde căldura sau umiditatea ar deteriora produsul. Principalele grupe sunt:/n1. Endoscoape - laringoscoape, bronhoscoape, esofagoscoape, cistoscoape și ureteroscoape, mediastinoscoape, toracoscoape și gastro-, duodeno-, bronho- și angioscoape cu fibre optice.
2. Materiale plastice și cauciuc — mănuși, pătuțuri pentru degete, seringi, dispozitive de injectare, seturi de colectare a sângelui și perfuzie, pungi de urină, eprubete, catetere intracraniene, venoase și arteriale, tuburi, drenuri, bureți și căptușeli.
3. Instruments and implants — automated suturing machines, sutures and suture needles, artificial oesophagus, bone, pericardium and vessels, PTFE membranes, artificial lung circuits, pacemakers and leads, drainage and post-operative suction sets, lumbar puncture kits, urinary catheter sets, peritoneal dialysis circuits, thermistors, stethoscopes, medical drills and saws, electrosurgical units, batteries, bone plates and cameras.
4. Anaesthesia and airway — endotracheal tubes, nasal cannulae, tracheostomy tubes, suction catheters, anaesthesia masks, corrugated tubing, breathing bags, closed circuits, ventilator components and nebulisers.
5. Cotton and textile products — gowns, gauze, bandages, cotton wool and similar dressings.
A. Payment is by bank transfer (T/T), with a minimum 30% advance payment. The delivery period is counted from the date the advance is received. Ten days before shipment the seller invites the buyer to the factory for a Factory Acceptance Test (FAT); attendance is the buyer's decision.
A. The chamber and main unit carry a warranty of at least 5 years, the control system 2 years, and other purchased components 1 year.
A. Yes. Once the machine arrives at the customer's plant, our engineers attend site to install it and train the operators.
A. Production and delivery take 60–90 days. After the EO sterilizer is complete, the customer may choose to run a Factory Acceptance Test (FAT) at our works. Installation and commissioning take 15–60 days depending on chamber size; IQ and OQ take about 7 days, and PQ support is available.
A. Of course. We welcome customers to visit the factory and would be glad to meet you in person.