ETO sterilizer گرم هوا جو نظام

Advanced Air-Jacketed Heating Technology

One of Bocon’s core engineering breakthroughs is our signature Air-Jacketed Heating System. Unlike traditional hot water jacket designs, Bocon utilizes a sophisticated hot air circulation system to maintain chamber temperature. This innovative approach offers a superior alternative to conventional systems, delivering significant advantages in operational safety, thermal precision, and long-term maintenance efficiency. By choosing air over water, we provide our clients with a cleaner, more reliable, and energy-efficient sterilization environment.

BOCON Hot Air Eto Sterilizer Specifications

تعميل: EN 1422، CE، ISO 13485 Support: FAT, SAT, DQ, IQ, OQ, PQ

انجنيئرنگ سپورٽ

Custom dimensions and automated conveyor systems are available upon request.

INQUIRE NOW

Bocon Hot Air Jacket ETO Sterilizer VS Traditional Water Jacket EO Sterilizer

Feature / Specification Bocon Hot Air Jacket System Traditional Water Jacket System
Heating Efficiency High: Uniformly blankets chamber and doors directly. Lower: Indirect heat transfer via water medium.
Energy Consumption Optimized: Only heats product load and air. High: Significant energy wasted to maintain water temperature.
Heat-up Time (from 21°C) Rapid: Less than 3 hours. Slow: Requires heating large volumes of water first.
Maintenance Requirements Low: Dry system, no additives or water pumps. High: Constant monitoring of corrosion and seal replacements.
Corrosion Risk Zero: Eliminates rust and mineral build-up. High: Prone to scaling and internal corrosion.
Leak Impact Minor: Non-critical for performance and easily repaired. Critical: Causes thermal instability and safety hazards.
Weight & Logistics Light: Easier rigging, installation, and lower shipping costs. Heavy: Complex structural requirements for installation.

BOCON EO اسٽريلائزر ڇو چونڊيو؟

Technological Excellence vs. Conventional Industry Standards.

180 ٽين / مهينو 20m³ چيمبر لاءِ پاڻي بچايو
(گيس-پاڻي جدا ڪندڙ سان ليس)
RMB 230,000 / سال بجلي بچايو (100m³ يونٽ)
چين جي صنعتي طاقت جي شرح جي بنياد تي
Air Jacket System بوڪون خاص
Maintenance-free Hot Air Tech
Centralized Heating بيڪار ڊبل پمپ استحڪام
for Multi-unit Layouts

1. ويڪيوم پمپ ٽيڪنالاجي

شيءِ بوڪون ٻيا
ويڪيوم پمپ جا اختيار خشڪ اسڪرو / واٽر رنگ / آئل رنگ (ڪيترائي آپشن دستياب) عام طور تي صرف واٽر رينگ پمپ
آخري ويڪيوم سطح -101.27 kPa تائين (خشڪ اسڪرو پمپ) لڳ ڀڳ. -90 kPa
پاڻي واپرائڻ With BOCON گئس-پاڻي جدا ڪندڙ: Water replaced once per week مسلسل پاڻي واپرائڻ
سار سنڀال گھٽ سار سنڀال (خشڪ پمپ)، ڪو به تيل emulsification خطري بار بار تيل جي تبديلي (تيل پمپ) يا محدود ڪارڪردگي

2. پاڻي بچائڻ جي ڪارڪردگي

3. Sterilizer Chamber Design

شيءِ بوڪون ٻيا
Chamber Type Water Jacket / Air Jacket (Hot Air System) Water Jacket Only
Heating Speed Fast heating & cooling (Air Jacket) Slower temperature transition
سار سنڀال No leakage risk, long service life (Air Jacket) Water leakage risk over time
Space Requirement Compact installation, suitable for multi-unit layout (Air Jacket) Larger footprint

4. Exclusive EG Burner System

شيءِ بوڪون ٻيا
نڪرڻ جو علاج توانائي جي بحالي سان گئس + مائع فضول دھڻ صرف ڪمبسشن (گيس) يا صرف اسڪربر
توانائي جي بحالي تيز گرمي پد فلو گيس اسٽريلائيزر جي استعمال لاءِ پاڻي کي گرم ڪري ٿو توانائي جي بحالي نه آهي
مائع ضايع ڪرڻ جو انتظام انٽيگريٽيڊ مائع فضول ڪمبشن اسڪربر مائع فضول کي علاج نٿو ڪري سگهي

5. Centralized Heating System

شيءِ بوڪون ٻيا
سسٽم ڊيزائن ٻٽي پمپ ريڊنڊنسي سان مرڪزي گرمائش اڪيلو پاڻي گرم ڪرڻ وارو يونٽ
سسٽم جي استحڪام بيڪ اپ پمپ مسلسل آپريشن کي يقيني بڻائي ٿو سسٽم بند ٿي ويندو جيڪڏهن پمپ ناڪام ٿئي
درخواست هڪ ورڪشاپ ۾ ڪيترن ئي sterilizers لاء مناسب انفرادي حرارتي في يونٽ

Full Technical Specifications & Properties

BOCON Hot Air ETO Sterilizer System Details

Feature Category Technical Specification
STANDARDS & PHYSICAL ACCESS
System Design Standards EN1422, ISO11135-2014
Door Configuration 2 Doors; Pneumatic translation seal (Default); Optional: Rotary or Lifting
CONTROL SYSTEM & DATA INTEGRITY
System Control Mode Soft Manual & Full-Automatic
Data Recording Interval mode & Warning triggered mode; Continuous curve recording
Data Storage Lifecycle 10 Years (Secure HDD Storage)
Data Processing PC Monitoring & Specialized Sterilization Data Software
SENSORS & PRECISION
Temp Control Precision Inside: ±3°C | Wall: ±5°C (Res: 0.1°C)
Pressure Management Range: -100 to +150Kpa; Res: 0.1Kpa; Resistance: up to 80KPa (Standard)
Vacuum Performance < 30 minutes (0 to -90KPa); Continuous/Stepping modes
Humidity Performance 0-100%RH (non-condensing); Resolution: 0.1%RH
AUTOMATION & SAFETY CONNECTORS
Automatic Detection Cabinet water volume, Steam pressure, and Vacuum pump monitoring
Safety Alerts Real-time display & warning for insufficient steam or pressure
System Protection Nitrogen protection (Optional/Auto); Tail gas treatment (Auto-control)
Exhaust Control In-door and Out-door air exhausting with automatic valve control
GAS RECIPES & PROCESS
Supported Gas Recipes Mixed Gas (CO2/EO mixtures: 70/30, 20/80, 10/90) and Pure EO (with N2)
Time Management 0-99 hours; Resolution: 1 min
Customized solutions for high-pressure chambers (>80KPa) and specific gas concentrations are available.

Technical FAQ

Expert insights into Bocon EtO Sterilization Hot Air Circulation Systems

EtO sterilization depends on the "Big Four" parameters: Gas concentration, Humidity, Time, and Temperature. Bocon's Hot Air System ensures that heat and moisture are distributed uniformly throughout the entire chamber load. This high-efficiency circulation eliminates cold spots and ensures that the EtO gas can penetrate dense medical device packaging effectively, regardless of their position in the sterilization chamber.
Our systems are engineered for high-precision thermal stability. We typically achieve a temperature uniformity of ±1°C or better within the chamber volume. This level of control is managed via advanced Siemens PLC controllers and high-accuracy RTD sensors, ensuring the process remains within the validated range required by ISO 11135 standards.
Since EtO is highly flammable and explosive, Bocon utilizes ATEX or IECEx-certified explosion-proof fans and specialized heating elements. The hardware is designed to prevent spark generation. Furthermore, the system is interlocked with the control software to ensure that the heating process only operates when gas concentrations are within safe levels, often involving nitrogen dilution as a safety cushion.
Absolutely. We provide modular solutions ranging from 1m³ laboratory units to 100m³ large-scale industrial chambers. We calculate the required thermal load and air exchange rates based on your specific product density and chamber volume to ensure optimal performance for your sterilization cycles.
To maintain medical-grade cleanliness and resist corrosion from sterilization gases, Bocon uses high-quality SS304 or SS316L stainless steel for all internal ducting, fan blades, and chamber surfaces. This ensures longevity and prevents any particulate contamination of the medical devices being processed.
Yes. All Bocon systems are equipped with advanced data acquisition capabilities. Every parameter—including temperature, pressure, and fan speed—is recorded in real-time. Our software is designed to be compliant with FDA 21 CFR Part 11, providing the electronic records and audit trails necessary for international regulatory inspections.

اسان جا ساٿي

ساٿي 1
ساٿي 11
ساٿي 2
ڀائيوار 12
ساٿي 7
ساٿي 6
ساٿي 3
ساٿي 5
ساٿي 9
ساٿي 4

جائزو

في الحال ڪوبه جائزو ناهي.

جائزو وٺڻ لاء پهريون ٿيو "ETO sterilizer گرم هوا جو نظام”

توهان جو اي ميل پتو شايع نه ڪيو ويندو. گهربل فيلڊ نشان لڳل آهن *

مٿي ڏانهن ڇڪيو