1.3 30 m³ eto gas sterilizer Composition

30 m³ヱ油氣體滅菌器由滅菌器外殼、輔助設備(加熱和熱循環裝置、真空抽吸裝置、加藥和汽化裝置、加濕裝置、密封裝置、殘餘氣體處理裝置)和監測控制裝置組成。

1.4 Classification

Based on the size of the eto gas sterilizer, there are two types: Class A and Class B.

  • Class A eto gas sterilizer — User-programmable sterilizer with a sterilization chamber volume > 1 m³, suitable for sterilizing in the medical device manufacturing industry.
  • Class Beto gas sterilizer — A sterilizer with one or more preset sterilization cycles and size limitations, with a sterilization chamber volume ? 1 m³, suitable for sterilizing clinical medical devices.

1.5 Model Difference Table

Table 1: Models and Basic Parameters of Ethylene Oxide Sterilizers

Serial No.Internal Chamber Dimensions (L×W×H) (mm) ±1%Nominal Volume (m³)
功率(kW)Weight (kg)Power Supply
1BCS-1型1400*700*10001m³161000380V/50Hz
2BCS-2型1650*1000*12002m³162000380V/50Hz
3BCS-3型1400*1350*17003.0m³163000380V/50Hz
4BCS-4.52000*1350*17004.5m³274000380V/50Hz
5BCS-5系列2250*1350*17005m³274500380V/50Hz
6BCS-6系列2700*1350*17006m³275000380V/50Hz
7BCS-8型3500*1350*17008m³276000380V/50Hz
8BCS-10型4500*1350*170010m³437000380V/50Hz
9BCS-15系列5500*1350*200015m³569000380V/50Hz
10BCS-20系列7500*1350*200020m³8112000380V/50Hz
11BCS-26型9600*1350*200026m³8114000380V/50Hz
12BCS-28型12500*1350*170028m³9014000380V/50Hz
13BCS-30型11300*1350*200030m³9017000380V/50Hz
14BCS-30-2型5600*2700*200030m³-29016000380V/50Hz
15BCS-35型13000*1350*200035m³10023000380V/50Hz
16BCS-35-2型6000*2700*220035m³-210022000380V/50Hz
17BCS-40-2型6650*2700*220040m³-210023000380V/50Hz
18BCS-48型12850*1400*270048m³10028000380V/50Hz
19BCS-52型13900*1400*270052m³15028000380V/50Hz
20BCS-55-2型7500*2700*270055m³-215027000380V/50Hz
21BCS-57-29650*2700*220057m³-215028000380V/50Hz
22BCS-63-28650*2700*270063m³-215029000380V/50Hz
23BCS-70-2型9700*2700*270070m³-215532000380V/50Hz
24BCS-78-210750*2700*270078m³-216535000380V/50Hz
25BCS-86-2型11800*2700*270086m³-216538000380V/50Hz
26BCS-101-217050*2700*2200101m³-220045000380V/50Hz
27BCS-120-2型20200*2700*2200120m³-220049000380V/50Hz

Sterilization Cycle and Automatic Control

2.10.7.1

The 30 m³ eto gas sterilizer should be equipped with an automatic controller that can automatically control the sterilization cycle.

2.10.7.2 Class A eto gas sterilizer:

  • The automatic controller should be able to program preset conditions for each stage of the sterilization cycle.
  • During the sterilization cycle, it must not change the preset variables.

2.10.7.3 Class B eto gas sterilizer:

  • The manufacturer applies the automatic controller to program the preset conditions for each stage of the sterilization cycle.
  • The manufacturer should provide methods to shorten the sterilization time for verification purposes, which can only be performed using a special key, password, or tool. Once the sterilization time is shortened, there should be a fault indication at the end of the operating cycle.

2.10.7.4

The controller should only be accessible using a special key, password, or tool. Additionally: a) For Class A sterilizers, access to the controller and setting of operational cycle variables should require a special key, password, or tool.
b) For Class B sterilizers, only the manufacturer can program new operational cycles.

2.10.7.5

During maintenance, testing, or emergencies, the program of the automatic controller should be operable manually. The manual device used should differ from the special key, password, or tool specified in section 2.10.7.4. When manual operation is performed due to maintenance, testing, or emergencies, the automatic program should stop automatically. The manual operation system should not pose a safety threat, allowing only one stage to be selected sequentially at a time.

2.10.7.6

Upon successful completion of each specified sterilization cycle, the automatic controller should indicate that the cycle is complete.