HZBOCON 2025 CNY-vakansie: 26 Januarie – 4 Februarie.
HZBOCON 2025 CNY-vakansie: 26 Januarie – 4 Februarie. Lees meer
The content details the manufacturing and performance specifications of the Bocon ethylene oxide sterilizer produced in China. It emphasizes compliance with international pressure vessel standards, equipped with stress-relieved welds and a patented heating jacket that enhances energy efficiency. The machine features a high-quality sealing ring, a robust 10-ton casing, and advanced dosing and monitoring systems to ensure operational reliability. Safety measures are highlighted, including explosion-proof components and efficient filtration systems. The control system is innovative and adaptable, supporting parameter release processes and accurate data management.
Gevorderde bocon ETO-sterilisators in China Lees meer
Hangzhou Bocon Mechanical and Electrical Equipment Co., Ltd( eto sterile machine manufacturer in china) was established in 2006. The office
eto steriele masjien vervaardiger in China Lees meer
The 30 m³ eto gas sterilizer consists of the sterilizer housing, auxiliary equipment (heating and thermal cycling device, vacuum extraction device, dosing and vaporization device, humidification device, sealing device, residual gas processing device), and monitoring and control device.
30 m³ eto-gassterilisator Lees meer
8.4.1 Closing the eto gas sterilizer Discharge Door 8.4.2 Opening the Loading Door 8.4.3 Loading Sterilization Items Use a forklift
Hoe om sterilisasieproduk te laai wanneer eto-gassterilisator gebruik word Lees meer
The installation and layout diagram of the ethylene oxide eto sterilizer can be found in Appendix C, Figure C.1. 7.1
Etileenoksied-sterilisator-installasiegids Lees meer
12m3 eto steriliseerder is gereed om aan ons kliënt te stuur
12m3 eto steriliseerder is gereed om aan ons kliënt te stuur Lees meer
3.4.1 eto sterilizer machine Temperature Setting Range
The temperature setting range for the eto sterilizer is: 30 to 70°C
Verstaan ETO-sterilisatorprestasie: sleutels tot doeltreffendheid Lees meer
If a leak is detected in the eto sterilizer dosing pipeline during the administration process, immediately close the medication bottle, switch and the dosing valve on the main unit. Turn on the axial fan to ensure proper ventilation, and then proceed with repairs.
Etileenoksied lek Hantering wanneer eto steriliseerder gebruik word Lees meer
Note: Regardless of whether the equipment is in normal operation, malfunction, or maintenance state, if personnel need to enter the
Veiligheidsvereistes vir die gebruik van etileenoksied in sterilisasie Lees meer