Daim duab qhia kev teeb tsa thiab kev teeb tsa ntawm ethylene oxide eto sterilizer tuaj yeem pom nyob rau hauv Appendix C, Daim duab C.1.

7.1 Ua ntej txhim kho ethylene oxide eto sterilizer

Cov neeg siv yuav tsum qhia txog 380V peb-theem plaub-xaim fais fab mov nrog rau kev tiv thaiv hauv av rau hauv chav tswj. Lub cable txuas rau lub tshuab hluav taws xob yuav tsum tau xaiv raws li Table 3. Ib qho kev hloov sab nraud thiab lub tshuab hluav taws xob hluav taws xob yuav tsum tau teeb tsa raws li qhov ntsuas lub zog ntawm cov khoom siv. Sab nraud hloov thiab cua Circuit Court breaker yuav tsum nyob ze ntawm cov khoom siv.

Table 3: Configuration Requirements rau Kev Txuas Hluav Taws Xob rau Sterilizer's Cable thiab Air Circuit Breaker

QauvCua Circuit Breaker Current (A)Copper Cable Hla-Section Area (?)
BCS-1304
BCS-2304
BCS-3304
BCS-4.5516
BCS-5516
BCS-6516
BCS-8516
BCS-108216
BCS-1510616
BCS-2015425
BCS-2615425
BCS-2817135
BCS-3017135
BCS-30-217135
BCS-3519050
BCS-35-219050
BCS-40-219050
BCS-4819050
BCS-5228570
BCS-55-228570
BCS-57-228570
BCS-63-228570
BCS-70-2294 ib70
BCS-78-231395
BCS-86-231395
BCS-101-2380120
BCS-120-2380120

7.2

Tag nrho cov kev tiv thaiv grounding terminals nyob rau hauv cov cuab yeej yuav tsum tau ruaj ntseg thiab ntseeg tau kev cob cog rua rau lub tswv yim tiv thaiv grounding hlau.

7.3

Lub sterilization chamber yuav tsum tau muab cais los ntawm cov tswj seem. Lub sterilization chamber ntawm ethylene oxide eto sterilizer yuav tsum tau muab tso rau hauv ib qho chaw ua hauj lwm, uas yuav tsum muaj cov dej, cov dej ntws, thiab cov chaw ua pa kom ua kom muaj cua zoo. Lub qhov cua tshuab yuav tsum xaiv rau qhov tawg-pov thawj axial flow kiv cua. Hauv pem teb nyob rau hauv qhov chaw ua haujlwm yuav tsum tiaj tus thiab ruaj khov, thiab lub cev ntawm cov tshuaj tua kab mob yuav tsum tau muab tso rau tsis tu ncua. Lub thickness ntawm cov pob zeb ua haujlwm hauv pem teb yuav tsum tsis pub tsawg tshaj 60 hli.

7.4 ib

Yog tias xav tau los ntawm tus neeg siv, yuav tsum siv lub tshuab tso pa tawm hauv zos uas tsis yog rov ua dua los tshem tawm cov pa phem (piv txwv li, cov khoom siv hluav taws xob tso rau pem hauv ntej ntawm ethylene oxide eto sterilizerdoor). Cov kev teeb tsa sib raug yuav tsum tau ua nyob rau ntawm qhov chaw raws li qhov tseeb.

7.5

Thaum lub sij hawm installation, qhov tsawg kawg nkaus nyob deb ntawm ib sab (los yog ob sab) ntawm cov cuab yeej mus rau phab ntsa (kem) yuav tsum yog 0.5 m, thiab yuav tsum muaj ib tug deb ntawm tsawg kawg yog 3 m ntawm ob qho tib si kawg rau kev thauj khoom thiab unloading lub hom phiaj kom tso cai rau kev thauj mus los.

7.6

Kev teeb tsa ntawm tag nrho cov kav dej yuav tsum xyuas kom tsis txhob muaj qhov xau, tshwj xeeb tshaj yog rau cov khoom siv tshuaj thiab lub tshuab nqus tsev; txwv tsis pub, kev nyab xeeb yuav tshwm sim.

7.7

Cov pa pa tawm los ntawm lub tshuab nqus tsev twj tso kua mis yuav tsum xub nkag mus rau hauv lub thawv kho mob, yuav tsum tau yaj hauv dej, thiab tom qab ntawd raug tso tawm los ntawm qhov hluav taws xob ntawm lub qhov tso pa tawm mus rau hauv lub pas dej ua haujlwm nruab nrab (uas yuav tsum tau npaj los ntawm tus neeg siv). Tom qab neutralization, nws yuav tsum tau muab tso rau hauv ib qho kev kaw qhov dej kaw. Txoj kab uas hla ntawm cov kav dej yuav tsum loj dua lub tshuab nqus tsev twj tso kua mis txoj kab uas hla (saib daim duab A.2-2 thiab D.1).

7.8 ib

Lub qhov hluav taws xob tso tawm ntawm qhov kev nyab xeeb valve yuav tsum siv cov yeeb nkab ntawm txoj kab uas tsim nyog los coj cov roj mus rau hauv lub pas dej ua ke kom tsis txhob muaj kev cuam tshuam ua ntej yuav raug tso tawm los ntawm cov yeeb nkab dej siab (saib daim duab A.2-2).

7.9 ib

Cov khoom tseem ceeb ntawm cov tshuaj tua kab mob, xws li lub chamber, tswj thav duab sib dhos, hluav taws xob tswj txee, lub tshuab nqus tsev piping, dej kub system piping, ethylene oxide system piping, thiab vaporization system piping, yuav tsum xa raws li cais modules thiab txuas rau ntawm qhov chaw los ntawm cov neeg ua haujlwm tshwj xeeb los ntawm peb lub hoobkas.

7.10 Nws

Qhov kev ncua deb tsawg kawg nkaus ntawm tus ncej tswj thiab lub txee tswj hluav taws xob yuav tsum yog 1 meter los tiv thaiv lub suab nrov rau cov neeg ua haujlwm ua haujlwm los ntawm lub suab siab tsim los ntawm lub twj tso kua mis thiab lub tshuab nqus tsev twj.

7.11 ib

Lub qhov cub yuav tsum tau muab los ntawm tus neeg siv, nrog rau qhov xav tau chav siab ntawm 0.25-0.4 MPa, chav kub ntawm 135-150 ° C, thiab qhov ntsuas evaporation muaj peev xwm ntau dua 3.5 kg / h.

7.12 ib

Lub tog raj kheej roj ethylene oxide yuav tsum tau muab los ntawm tus neeg siv. Lub qhov hluav taws xob siab ntawm ethylene oxide roj lub tog raj kheej yuav tsum tsis pub tshaj 0.4 MPa.

7.13

Kev teeb tsa ntawm ethylene oxide eto sterilizer yuav pab tau los ntawm cov neeg ua haujlwm tshwj xeeb los ntawm peb lub Hoobkas, thiab cov kws tshaj lij no yuav ua lub luag haujlwm rau cov khoom siv debugging.

Hu rau

Xov tooj:+8619975258603

Email:hayley@hzbocon.com ua

Chaw Nyob: Chav 1202, Caitong Zhongxin, Xiasha District, Hangzhou City, Zhejiang Province, Suav

Lub Vev Xaib:hzbocon.com ua zjbocon.com ua