Mahi Whakaritenga I mua i te Whakakotahitanga

Appearance Inspection: Check for any damage on the surfaces of the main machine, control rack, and electrical control cabinet.
Power Supply Check: Ensure the power supply meets the requirements and check the rotation direction of the water pump and vacuum pump.
Turn on the power and observe whether the instrument display values are normal; otherwise, cut off the power, inspect and repair before restarting.
Pipeline Inspection: Check for leaks in the water supply, vacuum, and medication delivery pipelines, and ensure all valves are in standby mode; adjust if necessary.

Mahi Whakaritenga I mua i te Whakakotahitanga Panui Panui

Request For Eto Gas Sterilizer Manufacturer

2.1.1 The overall shape should be precise, with smooth, clean surfaces and uniform color. There should be no burrs, sharp edges, cracks, visible scratches, or unevenness.
2.1.2 All external text, graphics, and symbols must be printed clearly, with precise and durable markings.
2.1.3 Fasteners must be securely installed. All control switches and adjustment knobs (or buttons) should operate smoothly and reliably without obstructions.

Request For Eto Gas Sterilizer Manufacturer Panui Panui

Routine Monitoring, Control, and Release of Ethylene Oxide Sterilization

Ko te kaupapa o te aro turuki me te whakahaere i te whakahoromata EO (Ethylene Oxide) ko te whakaatu kua tukuna te tukanga whakakorikori kua whakapumautia, kua tohua ki te hua. Ko nga raraunga mai i ia huringa whakahoromata me tuhi me te pupuri tonu hei tohu kua tutuki nga whakaritenga o te tukanga whakahoromata. Me whakauru i te iti rawa nga ihirangi e whai ake nei:

Routine Monitoring, Control, and Release of Ethylene Oxide Sterilization Panui Panui

Te whakaputanga o nga taputapu Wero Tukatuka i roto i te whakahoromata

A Process Challenge Device (PCD) is a microbiological challenge system used to evaluate the kill rate of selected process parameters. It is typically a device or test package containing biological indicators (e.g., Bacillus atrophaeus spores with known spore count). The resistance of the PCD to the sterilization process should be greater than or equal to the resistance of the natural microbial load in the most difficult-to-sterilize area of the product. The quantity of PCDs should meet the requirements outlined in Table C.3 of Appendix C in GB18279.1-2015. PCDs are classified into Internal PCDs (IPCD) and External PCDs (EPCD).