30 m³ te whakahoroa hau



1.3 30 m³ eto gas sterilizer Composition
Ko te 30 m³ eto hau sterilizer ngā o te whare sterilizer, taputapu pŭpŭ tauturu (whakawera me te waiariki paihikara pūrere, pūrere tangohanga korehau, taputapu toketaá me te whakapoapoa, pūrere humidification, pūrere hiri, pūrere hau toenga), me te pūrere aroturuki me te whakahaere.
1.4 Classification
Based on the size of the eto gas sterilizer, there are two types: Class A and Class B.
- Class A eto gas sterilizer — User-programmable sterilizer with a sterilization chamber volume > 1 m³, suitable for sterilizing in the medical device manufacturing industry.
- Class Beto gas sterilizer — A sterilizer with one or more preset sterilization cycles and size limitations, with a sterilization chamber volume ? 1 m³, suitable for sterilizing clinical medical devices.
1.5 Model Difference Table
Table 1: Models and Basic Parameters of Ethylene Oxide Sterilizers
| Serial No. | Tauira | Internal Chamber Dimensions (L×W×H) (mm) ±1% | Nominal Volume (m³) | Hiko (kW) | Weight (kg) | Power Supply |
| 1 | BCS-1 | 1400 * 700 * 1000 | 1M³ | 16 | 1000 | 380V/50Hz |
| 2 | BCS-2 | 1650 * 1000 * 1200 | 2m³ | 16 | 2000 | 380V/50Hz |
| 3 | BCS-3 | 1400 * 1350 * 1700 | 3.0m³ | 16 | 3000 | 380V/50Hz |
| 4 | BCS-4.5 | 2000 * 1350 * 1700 | 4.5m³ | 27 | 4000 | 380V/50Hz |
| 5 | BCS-5 | 2250 * 1350 * 1700 | 5m³ | 27 | 4500 | 380V/50Hz |
| 6 | BCS-6 | 2700 * 1350 * 1700 | 6m³ | 27 | 5000 | 380V/50Hz |
| 7 | BCS-8 | 3500 * 1350 * 1700 | 8m³ | 27 | 6000 | 380V/50Hz |
| 8 | BCS-10 | 4500 * 1350 * 1700 | 10m³ | 43 | 7000 | 380V/50Hz |
| 9 | BCS-15 | 5500 * 1350 * 2000 | 15m³ | 56 | 9000 | 380V/50Hz |
| 10 | BCS-20 | 7500 * 1350 * 2000 | 20m³ | 81 | 12000 | 380V/50Hz |
| 11 | BCS-26 | 9600 * 1350 * 2000 | 26M³ | 81 | 14000 | 380V/50Hz |
| 12 | BCS-28 | 12500 * 1350 * 1700 | 28m³ | 90 | 14000 | 380V/50Hz |
| 13 | BCS-30 | 11300 * 1350 * 2000 | 30m³ | 90 | 17000 | 380V/50Hz |
| 14 | BCS-30-2 | 5600 * 2700 * 2000 | 30m³-2 | 90 | 16000 | 380V/50Hz |
| 15 | BCS-35 | 13000 * 1350 * 2000 | 35m³ | 100 | 23000 | 380V/50Hz |
| 16 | BCS-35-2 | 6000 * 2700 * 2200 | 35m³-2 | 100 | 22000 | 380V/50Hz |
| 17 | BCS-40-2 | 6650 * 2700 * 2200 | 40m³-2 | 100 | 23000 | 380V/50Hz |
| 18 | BCS-48 | 12850 * 1400 * 2700 | 48m³ | 100 | 28000 | 380V/50Hz |
| 19 | BCS-52 | 13900 * 1400 * 2700 | 52m³ | 150 | 28000 | 380V/50Hz |
| 20 | BCS-55-2 | 7500 * 2700 * 2700 | 55m³-2 | 150 | 27000 | 380V/50Hz |
| 21 | BCS-57-2 | 9650 * 2700 * 2200 | 57m³-2 | 150 | 28000 | 380V/50Hz |
| 22 | BCS-63-2 | 8650 * 2700 * 2700 | 63m³-2 | 150 | 29000 | 380V/50Hz |
| 23 | BCS-70-2 | 9700 * 2700 * 2700 | 70m³-2 | 155 | 32000 | 380V/50Hz |
| 24 | BCS-78-2 | 10750 * 2700 * 2700 | 78m³-2 | 165 | 35000 | 380V/50Hz |
| 25 | BCS-86-2 | 11800 * 2700 * 2700 | 86m³-2 | 165 | 38000 | 380V/50Hz |
| 26 | BCS-101-2 | 17050 * 2700 * 2200 | 101m³-2 | 200 | 45000 | 380V/50Hz |
| 27 | BCS-120-2 | 20200 * 2700 * 2200 | 120m³-2 | 200 | 49000 | 380V/50Hz |
Sterilization Cycle and Automatic Control
2.10.7.1
The 30 m³ eto gas sterilizer should be equipped with an automatic controller that can automatically control the sterilization cycle.
2.10.7.2 Class A eto gas sterilizer:
- The automatic controller should be able to program preset conditions for each stage of the sterilization cycle.
- During the sterilization cycle, it must not change the preset variables.
2.10.7.3 Class B eto gas sterilizer:
- The manufacturer applies the automatic controller to program the preset conditions for each stage of the sterilization cycle.
- The manufacturer should provide methods to shorten the sterilization time for verification purposes, which can only be performed using a special key, password, or tool. Once the sterilization time is shortened, there should be a fault indication at the end of the operating cycle.
2.10.7.4
The controller should only be accessible using a special key, password, or tool. Additionally: a) For Class A sterilizers, access to the controller and setting of operational cycle variables should require a special key, password, or tool.
b) For Class B sterilizers, only the manufacturer can program new operational cycles.
2.10.7.5
I nga wa tiaki, whakamatautau, ohorere ranei, me mahi a-ringa te hotaka o te kaiwhakahaere aunoa. Ko te taputapu a-ringa e whakamahia ana me rereke mai i te taviri motuhake, kupuhipa, taputapu ranei kua tohua i te waahanga 2.10.7.4. Ina mahia te mahi a-ringa na te tiaki, te whakamatautau, me nga ohorere ranei, me mutu aunoa te hotaka aunoa. Ko te punaha whakahaere a-ringa kia kaua e whakatuma he whakatuma mo te haumarutanga, kia kotahi noa te waahanga ka kowhirihia i te waa kotahi.
2.10.7.6
I te otinga angitu o ia huringa whakahoromata kua tohua, me tohu te kaiwhakahaere aunoa kua oti te huringa.
Mena kei te hiahia koe ki te mohio atu
Waea:+8619975258603
Īmēra:hayley@hzbocon.com
Pae Rohe: Room 1202, Caitong Zhongxin, Takiwa Xiasha, Hangzhou City, Zhejiang Province, Haina
paetukutuku:hzbocon.comzjbocon.com