eto dauðhreinsun Hólfhita dreifingarprófun
Hitastig dæmigerðra svæða á innra yfirborði skal mæla og skrá með því að nota hitaskráningartæki sem uppfylla kröfur viðauka B.
eto dauðhreinsun Hólfhita dreifingarprófun Lestu meira
Hitastig dæmigerðra svæða á innra yfirborði skal mæla og skrá með því að nota hitaskráningartæki sem uppfylla kröfur viðauka B.
eto dauðhreinsun Hólfhita dreifingarprófun Lestu meira
Útlitsskoðun: Athugaðu aðaleininguna, stýrigrindina og rafmagnsstýriskápinn fyrir skemmdir á yfirborðinu.
Undirbúningsvinna fyrir ófrjósemisaðgerð Lestu meira
Start cycle phase(Select parameters/sterilization recipe) Serial number Potentially risky content Risk assessment under existing process conditions Risk assessment of the
EO dauðhreinsunarbúnaður og ferli einkennandi mynstur og áhrifagreining Lestu meira
9.1 During ETO Sterilization, operators are not allowed to leave the operating area and must continuously observe the ETO Sterilization process. If any abnormal phenomena occur, the machine must be immediately shut down, and the power supply should be cut off for inspection.
Viðhaldsleiðbeiningar fyrir ETO dauðhreinsunartæki Lestu meira
For the purposes of this document, the following terms and definitions apply in ethylene oxide sterilization 3.1 Aeration part of
Hugtök og skilgreiningar á dauðhreinsun eto gas Lestu meira
Appearance Inspection: Check for any damage on the surfaces of the main machine, control rack, and electrical control cabinet.
Power Supply Check: Ensure the power supply meets the requirements and check the rotation direction of the water pump and vacuum pump.
Turn on the power and observe whether the instrument display values are normal; otherwise, cut off the power, inspect and repair before restarting.
Pipeline Inspection: Check for leaks in the water supply, vacuum, and medication delivery pipelines, and ensure all valves are in standby mode; adjust if necessary.
Undirbúningsvinna fyrir eo ófrjósemisaðgerð Lestu meira
2.1.1 The overall shape should be precise, with smooth, clean surfaces and uniform color. There should be no burrs, sharp edges, cracks, visible scratches, or unevenness.
2.1.2 All external text, graphics, and symbols must be printed clearly, with precise and durable markings.
2.1.3 Fasteners must be securely installed. All control switches and adjustment knobs (or buttons) should operate smoothly and reliably without obstructions.
Request For Eto Gas Sterilizer Manufacturer Lestu meira
Within a certain range of gas concentration, the higher the concentration, the better theEO Gas Sterilization effect; beyond 1000 mg/L, the improvement in sterilization effect is not significant.
Þættir sem hafa áhrif á EO-gas sótthreinsunarferlið Lestu meira
eto sterilization technologies vs others: Advantages and Disadvantages Sterilization is a critical process in infection control, ensuring that medical instruments
Comparing ETO Sterilization to Other Methods Lestu meira
The temperature setting range of the ETO Sterilization Chamber should be between 30-60°C. It is recommended to perform temperature distribution testing of the sterilizer’s internal surface and temperature and humidity distribution testing inside the sterilization chamber to ensure the effectiveness of the heating and humidifying systems.
ETO Sterilization Chamber Testing Lestu meira