HZBOCON 2025 CNY holiday: Jan 26th – Feb 4th.
HZBOCON 2025 CNY holiday: Jan 26th – Feb 4th. Aqra aktar
The content details the manufacturing and performance specifications of the Bocon ethylene oxide sterilizer produced in China. It emphasizes compliance with international pressure vessel standards, equipped with stress-relieved welds and a patented heating jacket that enhances energy efficiency. The machine features a high-quality sealing ring, a robust 10-ton casing, and advanced dosing and monitoring systems to ensure operational reliability. Safety measures are highlighted, including explosion-proof components and efficient filtration systems. The control system is innovative and adaptable, supporting parameter release processes and accurate data management.
Advanced bocon ETO Sterilizers in China Aqra aktar
Hangzhou Bocon Mechanical and Electrical Equipment Co., Ltd( eto sterile machine manufacturer in china) was established in 2006. The office
manifattur tal-magni sterili eto fiċ-Ċina Aqra aktar
L-isterilizzatur tal-gass eto ta '30 m³ jikkonsisti mill-akkomodazzjoni tal-isterilizzatur, tagħmir awżiljarju (apparat ta' tisħin u ċikliżmu termali, apparat ta 'estrazzjoni bil-vakwu, apparat ta' dożaġġ u vaporizzazzjoni, apparat ta 'umidifikazzjoni, apparat tas-siġillar, apparat għall-ipproċessar tal-gass residwu), u apparat ta' monitoraġġ u kontroll.
Sterilizzatur tal-gass eto ta '30 m³ Aqra aktar
8.4.1 Closing the eto gas sterilizer Discharge Door 8.4.2 Opening the Loading Door 8.4.3 Loading Sterilization Items Use a forklift
Kif Tagħbija Prodott ta 'Sterilizzazzjoni meta tuża sterilizzatur tal-gass eto Aqra aktar
The installation and layout diagram of the ethylene oxide eto sterilizer can be found in Appendix C, Figure C.1. 7.1
Ethylene Oxide Sterilizer Installation Guide Aqra aktar
12m3 eto sterilizer huwa lest biex jibgħat lill-klijent tagħna
12m3 eto sterilizer huwa lest biex jibgħat lill-klijent tagħna Aqra aktar
3.4.1 Firxa tal-Issettjar tat-Temperatura tal-magna tal-isterilizzatur eto
The temperature setting range for the eto sterilizer is: 30 to 70°C
Understanding ETO Sterilizer Performance: Keys to Efficiency Aqra aktar
If a leak is detected in the eto sterilizer dosing pipeline during the administration process, immediately close the medication bottle, switch and the dosing valve on the main unit. Turn on the axial fan to ensure proper ventilation, and then proceed with repairs.
Immaniġġjar tat-Tnixxija tal-Ossidu tal-Etilene meta tuża sterilizzatur eto Aqra aktar
Note: Regardless of whether the equipment is in normal operation, malfunction, or maintenance state, if personnel need to enter the
Safety Requirements for Using Ethylene Oxide in sterilization Aqra aktar