ETO Sterilization Re-qualification Requirements
1. Re-qualification Frequency
•Minimum annual requirement
• At least once per year, verification data, subsequent re-validation data, and routine processing data must be reviewed
• The scope of re-qualification must be determined and documented
• The review procedure shall be documented
2. Is Re-qualification Needed if No Product Changes Occur?
•Yes, re-qualification is still required
3. Re-qualification Items
•Based on certain preconditions, the following options are available:
- Full re-qualification
- No need for physical or microbial re-validation
- Small-scale microbial performance validation
Prerequisites for Re-qualification
a) The following must be reviewed/tested:
b) Whether anysignificant changes affecting product sterility have occurred in:
- Product design
- Manufacturing/packaging materials
- PCD (Process Challenge Device)
- Suppliers
- Manufacturing areas/facilities
- Load configurations or manufacturing processes
c)Bioburden trend analysis of products;
d) Whethertemperature distribution studies and sterilizer operation demonstrate significant changes since last qualification;
e) Whethertemperature distribution and recirculation checks in preconditioning chambers or aeration zones show significant changes since last qualification;
f) Whether ETO Sterilization process history since last validation demonstrates reproducibility;
g) Whetherchange control and preventive maintenance records confirm no equipment modifications affecting the process;
h) Whetherno alterations to the ETO Sterilization process affecting sterility have occurred;
i) IfETO Sterilization process specifications changed, re-qualification must include verification ofEO residue limits compliance with regulatory requirements.
Regulatory Standards
- ISO 11135:2014 (Sec. 9.2: Requalification criteria)
- FDA 21 CFR 211.113 (Sterilization process controls)
- EU GMP Annex 1:2022 (Sec. 8.5: Revalidation requirements)
ETO Sterilization Re-qualification Requirements
The re-qualification shallinclude a review of chamber performance and annual engineering changes to ensure the original IQ/OQ results remain valid. The review must cover:
- Preconditioning zone temperature/humidity profiles (if applicable);
- Actual empty chamber humidity profiles;
- Aeration zone temperatures (if applicable);
- Additionally, even if process specifications are met, inspections must be triggered by:
- Adverse trends in equipment performance,
- Sterility failures;
- To determine if re-validation is warranted.
- Sterilization experts shall define the scope of requiredphysical and microbial re-validation based on review outcomes.
Critical Considerations for Sterilization Re-qualification
1. Handling Significant Changes
• Ifmajor changes are identified during re-qualification, re-execution of IQ/OQ/PQ may be required:
- IQ (Installation Qualification): Verify modified equipment/software installation.
- OQ (Operational Qualification): Retest impacted functional parameters.
- PQ (Performance Qualification): Re-validate sterilization efficacy under new conditions.
2. Additional Requirements for Parametric Release
For facilities usingparametric release (relying on process data rather than BI testing):
a)Re-validation frequency: Must be performedat least annually;
b)Re-validation scope: Must includemicrobiological studies to confirm:
Situations Requiring Full Requalification (IQ/OQ/PQ):
a)Major maintenance of the sterilizer;
b)Structural, location, or environmental changes;
c)Unexplained sterility failures;
d)Changes in EO supply/delivery, diluent, or chamber load configuration.
Exemption from Physical or Microbial Re-qualification
When the following conditions are met:
- No changes in product, packaging, equipment/services, or processes;
- Chamber performance and engineering review are qualified;
- Routine sterilization processes have operated reliably during the period;
?Professional judgment may determine that physical or microbial re-qualification isnot required until the next review.
Limited-Scale Microbial Performance Qualification
•May be required in specific cases, such as:
- Verifying continued suitability of BIs relative to product bioburden;
- Providing evidence that nounintended changes occurred since the previous (re)qualification study after a defined time interval.
•General requirements (at minimum): - Oneshort-cycle or half-cycle run;
- Includingtemperature and humidity measurements of sterilized items.