BOCON Hot Air Eto Sterilizer Specifications
Súlad: EN 1422, CE, ISO 13485 Support: FAT, SAT, DQ, IQ, OQ, PQ
Technická podpora
Custom dimensions and automated conveyor systems are available upon request.
INQUIRE NOW →Bocon Hot Air Jacket ETO Sterilizer VS Traditional Water Jacket EO Sterilizer
| Feature / Specification | Bocon Hot Air Jacket System | Traditional Water Jacket System |
|---|---|---|
| Heating Efficiency | High: Uniformly blankets chamber and doors directly. | Lower: Indirect heat transfer via water medium. |
| Energy Consumption | Optimized: Only heats product load and air. | High: Significant energy wasted to maintain water temperature. |
| Heat-up Time (from 21°C) | Rapid: Less than 3 hours. | Slow: Requires heating large volumes of water first. |
| Maintenance Requirements | Low: Dry system, no additives or water pumps. | High: Constant monitoring of corrosion and seal replacements. |
| Corrosion Risk | Zero: Eliminates rust and mineral build-up. | High: Prone to scaling and internal corrosion. |
| Leak Impact | Minor: Non-critical for performance and easily repaired. | Critical: Causes thermal instability and safety hazards. |
| Weight & Logistics | Light: Easier rigging, installation, and lower shipping costs. | Heavy: Complex structural requirements for installation. |
Prečo si vybrať sterilizátor BOCON EO?
Technological Excellence vs. Conventional Industry Standards.
(Vybavené odlučovačom plynu a vody)
Na základe sadzieb za priemyselnú energiu v Číne
Maintenance-free Hot Air Tech
for Multi-unit Layouts
1. Technológia vákuovej pumpy
| Položka | BOCON | INÉ |
|---|---|---|
| Možnosti vákuovej pumpy | Suchá skrutka / vodný krúžok / olejový krúžok (k dispozícii je viacero možností) | Zvyčajne iba vodné kruhové čerpadlo |
| Maximálna úroveň vákua | Až -101,27 kPa (suché skrutkové čerpadlo) | Pribl. -90 kPa |
| Spotreba vody | With BOCON Odlučovač vody a plynu: Water replaced once per week | Nepretržitá spotreba vody |
| Údržba | Nízka údržba (suché čerpadlo), žiadne riziko emulgácie oleja | Častá výmena oleja (Olejové čerpadlo) alebo obmedzený výkon |
2. Úspora vody
Príklad: Vodokruhové čerpadlo s výkonom 5,5 kW spotrebuje približne 20 litrov za minútu. Pre 20 m³ sterilizačnú komoru s 8 vákuovými cyklami (každý 22 minút) dosiahne celková spotreba vody na cyklus 3,52 tony.
Pri 14 cykloch týždenne celková týždenná spotreba presahuje 49 ton. Po inštalácii Exkluzívny odlučovač plynu a vody BOCON výmena vody je potrebná len raz za týždeň, čím sa ušetrí približne 45 tons of water per week (approx. 180 tons per month). This is especially valuable in water-scarce regions.
3. Sterilizer Chamber Design
| Položka | BOCON | INÉ |
|---|---|---|
| Chamber Type | Water Jacket / Air Jacket (Hot Air System) | Water Jacket Only |
| Heating Speed | Fast heating & cooling (Air Jacket) | Slower temperature transition |
| Údržba | No leakage risk, long service life (Air Jacket) | Water leakage risk over time |
| Space Requirement | Compact installation, suitable for multi-unit layout (Air Jacket) | Larger footprint |
4. Exclusive EG Burner System
| Položka | BOCON | INÉ |
|---|---|---|
| Spracovanie výfukových plynov | Spaľovanie plynu + kvapalného odpadu s energetickým zhodnotením | Iba spaľovanie (plyn) alebo len práčka |
| Rekuperácia energie | Vysokoteplotné spaliny ohrievajú vodu na použitie v sterilizátore | Žiadna rekuperácia energie |
| Nakladanie s tekutým odpadom | Integrované spaľovanie kvapalného odpadu | Čistiaca jednotka nemôže spracovávať tekutý odpad |
5. Centralized Heating System
| Položka | BOCON | INÉ |
|---|---|---|
| Návrh systému | Centrálne vykurovanie s duálnou redundanciou čerpadla | Jedna jednotka na ohrev vody |
| Stabilita systému | Záložné čerpadlo zabezpečuje nepretržitú prevádzku | Systém sa zastaví, ak čerpadlo zlyhá |
| Aplikácia | Vhodné pre viacero sterilizátorov v jednej dielni | Individuálne vykurovanie na jednotku |
Full Technical Specifications & Properties
BOCON Hot Air ETO Sterilizer System Details
| Feature Category | Technical Specification |
|---|---|
| STANDARDS & PHYSICAL ACCESS | |
| System Design Standards | EN1422, ISO11135-2014 |
| Door Configuration | 2 Doors; Pneumatic translation seal (Default); Optional: Rotary or Lifting |
| CONTROL SYSTEM & DATA INTEGRITY | |
| System Control Mode | Soft Manual & Full-Automatic |
| Data Recording | Interval mode & Warning triggered mode; Continuous curve recording |
| Data Storage Lifecycle | 10 Years (Secure HDD Storage) |
| Data Processing | PC Monitoring & Specialized Sterilization Data Software |
| SENSORS & PRECISION | |
| Temp Control Precision | Inside: ±3°C | Wall: ±5°C (Res: 0.1°C) |
| Pressure Management | Range: -100 to +150Kpa; Res: 0.1Kpa; Resistance: up to 80KPa (Standard) |
| Vacuum Performance | < 30 minutes (0 to -90KPa); Continuous/Stepping modes |
| Humidity Performance | 0-100%RH (non-condensing); Resolution: 0.1%RH |
| AUTOMATION & SAFETY CONNECTORS | |
| Automatic Detection | Cabinet water volume, Steam pressure, and Vacuum pump monitoring |
| Safety Alerts | Real-time display & warning for insufficient steam or pressure |
| System Protection | Nitrogen protection (Optional/Auto); Tail gas treatment (Auto-control) |
| Exhaust Control | In-door and Out-door air exhausting with automatic valve control |
| GAS RECIPES & PROCESS | |
| Supported Gas Recipes | Mixed Gas (CO2/EO mixtures: 70/30, 20/80, 10/90) and Pure EO (with N2) |
| Time Management | 0-99 hours; Resolution: 1 min |
Technical FAQ
Expert insights into Bocon EtO Sterilization Hot Air Circulation Systems
Naši partneri


















Reviews
There are no reviews yet.