ETO sterilizáló forró levegő rendszer

Advanced Air-Jacketed Heating Technology

One of Bocon’s core engineering breakthroughs is our signature Air-Jacketed Heating System. Unlike traditional hot water jacket designs, Bocon utilizes a sophisticated hot air circulation system to maintain chamber temperature. This innovative approach offers a superior alternative to conventional systems, delivering significant advantages in operational safety, thermal precision, and long-term maintenance efficiency. By choosing air over water, we provide our clients with a cleaner, more reliable, and energy-efficient sterilization environment.

BOCON Hot Air Eto Sterilizer Specifications

Megfelelés: EN 1422, CE, ISO 13485 Support: FAT, SAT, DQ, IQ, OQ, PQ

Engineering Support

Igény szerint egyedi méretek és automata szállítószalagok is rendelkezésre állnak.

ÉRDEKLŐDJ MOST →

Bocon Hot Air Jacket ETO Sterilizátor VS Traditional Water Jacket EO Sterilizátor

Funkció / Specifikáció Bocon Hot Air Jacket System Hagyományos vízköpeny rendszer
Fűtési Hatékonyság Magas: Egyenletesen takarja be közvetlenül a kamrát és az ajtókat. Alsó: Közvetett hőátadás vízközegen keresztül.
Energiafogyasztás Optimalizált: Csak a termékterhelést és a levegőt melegíti. Magas: Jelentős energiapazarlás a víz hőmérsékletének fenntartásához.
Felfűtési idő (21°C-tól) Gyors: kevesebb, mint 3 óra. Lassú: Először nagy mennyiségű vizet kell felmelegíteni.
Karbantartási követelmények Alacsony: Száraz rendszer, nincs adalékanyag vagy vízszivattyú. Magas: A korrózió és a tömítések folyamatos ellenőrzése.
Korrózióveszély Nulla: Megszünteti a rozsdát és az ásványi anyagok lerakódását. Magas: Hajlamos a vízkőképződésre és a belső korrózióra.
Szivárgás hatás Kisebb: A teljesítmény szempontjából nem kritikus és könnyen javítható. Kritikus: Termikus instabilitást és biztonsági kockázatokat okoz.
Weight & Logistics Könnyű: Könnyebb kötélzet, telepítés és alacsonyabb szállítási költségek. Nehéz: A telepítés összetett szerkezeti követelményei.

Miért válassza a BOCON EO sterilizátort?

Technológiai kiválóság kontra hagyományos iparági szabványok.

180 tonna / hónap Megtakarított víz 20 m³-es kamrához
(Gáz-víz leválasztóval felszerelt)
230 000 RMB / év Megtakarított áram (100 m³ egység)
Kína ipari teljesítménye alapján
Air Jacket System Bocon Exkluzív
Karbantartást nem igénylő Hot Air Tech
Központi fűtés Redundáns kétszivattyús stabilitás
többegységes elrendezésekhez

1. Vákuumszivattyús technológia

Tétel BOCON EGYÉB
Vákuumszivattyú opciók Dry Screw / Water Ring / Oil Ring (Multiple options available) Usually only Water Ring Pump
Ultimate Vacuum Level Up to -101.27 kPa (Dry Screw Pump) Approx. -90 kPa
Water Consumption With BOCON Gas-water separator: Water replaced once per week Continuous water consumption
Maintenance Low maintenance (Dry pump), No oil emulsification risk Frequent oil change (Oil pump) or limited performance

2. Water-Saving Performance

3. Sterilizátorkamra kialakítása

Tétel BOCON EGYÉB
Kamra típusa Vízköpeny / Légkabát (Hot Air rendszer) Csak vízkabát
Fűtési sebesség Fast heating & cooling (Air Jacket) Lassabb hőmérséklet-átmenet
Maintenance Nincs szivárgási kockázat, hosszú élettartam (légkabát) Idővel vízszivárgás veszélye
Helyigény Kompakt telepítés, több egységből álló elrendezéshez is alkalmas (légkabát) Nagyobb lábnyom

4. Exkluzív EG égőrendszer

Tétel BOCON EGYÉB
Kipufogógáz kezelés Gáz + folyékony hulladék égetése energia visszanyeréssel Csak égés (gáz) vagy csak gázmosó
Energia-visszanyerés A magas hőmérsékletű füstgáz felmelegíti a vizet a sterilizáló használatához Nincs energia visszanyerés
Folyékony hulladék kezelése Integrált folyékony hulladék égetése A mosógép nem tudja kezelni a folyékony hulladékot

5. Központi fűtési rendszer

Tétel BOCON EGYÉB
Rendszertervezés Központi fűtés kettős szivattyú redundanciával Egy vízmelegítő egység
Rendszerstabilitás A tartalék szivattyú biztosítja a folyamatos működést A rendszer leáll, ha a szivattyú meghibásodik
Alkalmazás Alkalmas több sterilizálóhoz egy műhelyben Egyedi fűtés egységenként

Full Technical Specifications & Properties

BOCON Hot Air ETO Sterilizer System Details

Feature Category Technical Specification
STANDARDS & PHYSICAL ACCESS
System Design Standards EN1422, ISO11135-2014
Door Configuration 2 Doors; Pneumatic translation seal (Default); Optional: Rotary or Lifting
CONTROL SYSTEM & DATA INTEGRITY
System Control Mode Soft Manual & Full-Automatic
Data Recording Interval mode & Warning triggered mode; Continuous curve recording
Data Storage Lifecycle 10 Years (Secure HDD Storage)
Data Processing PC Monitoring & Specialized Sterilization Data Software
SENSORS & PRECISION
Temp Control Precision Inside: ±3°C | Wall: ±5°C (Res: 0.1°C)
Pressure Management Range: -100 to +150Kpa; Res: 0.1Kpa; Resistance: up to 80KPa (Standard)
Vacuum Performance < 30 minutes (0 to -90KPa); Continuous/Stepping modes
Humidity Performance 0-100%RH (non-condensing); Resolution: 0.1%RH
AUTOMATION & SAFETY CONNECTORS
Automatic Detection Cabinet water volume, Steam pressure, and Vacuum pump monitoring
Safety Alerts Real-time display & warning for insufficient steam or pressure
System Protection Nitrogen protection (Optional/Auto); Tail gas treatment (Auto-control)
Exhaust Control In-door and Out-door air exhausting with automatic valve control
GAS RECIPES & PROCESS
Supported Gas Recipes Mixed Gas (CO2/EO mixtures: 70/30, 20/80, 10/90) and Pure EO (with N2)
Time Management 0-99 hours; Resolution: 1 min
Customized solutions for high-pressure chambers (>80KPa) and specific gas concentrations are available.

Technical FAQ

Expert insights into Bocon EtO Sterilization Hot Air Circulation Systems

EtO sterilization depends on the "Big Four" parameters: Gas concentration, Humidity, Time, and Temperature. Bocon's Hot Air System ensures that heat and moisture are distributed uniformly throughout the entire chamber load. This high-efficiency circulation eliminates cold spots and ensures that the EtO gas can penetrate dense medical device packaging effectively, regardless of their position in the sterilization chamber.
Our systems are engineered for high-precision thermal stability. We typically achieve a hőmérséklet egyenletessége ±1°C vagy jobb esetben a kamratérfogaton belül. Ezt a vezérlési szintet a speciálisan keresztül kezelik Siemens PLC vezérlők és nagy pontosságú RTD érzékelők, amelyek biztosítják, hogy a folyamat az ISO 11135 szabványok által megkövetelt validált tartományon belül maradjon.
Mivel az EtO nagyon gyúlékony és robbanásveszélyes, a Bocon ezt használja ATEX vagy IECEx tanúsítvánnyal rendelkező robbanásbiztos ventilátorok és speciális fűtőelemek. A hardvert úgy tervezték, hogy megakadályozza a szikraképződést. Ezenkívül a rendszer össze van kapcsolva a vezérlőszoftverrel, így biztosítva, hogy a fűtési folyamat csak akkor működjön, ha a gázkoncentráció a biztonságos szinten van, gyakran nitrogénhígítással, mint biztonsági párna.
Teljesen. Moduláris megoldásokat kínálunk től kezdve 1 m³-es laboratóriumi egységek 100 m³-es nagyméretű ipari kamrákig. A szükséges hőterhelést és levegőcsere-arányokat az Ön konkrét terméksűrűsége és kamratérfogata alapján számítjuk ki, hogy biztosítsuk a sterilizációs ciklusok optimális teljesítményét.
Az orvosi tisztaság fenntartása és a sterilizációs gázok okozta korrózió elleni védelem érdekében a Bocon kiváló minőségű anyagokat használ. SS304 vagy SS316L rozsdamentes acél minden belső csatornához, ventilátorlapáthoz és kamrafelülethez. Ez biztosítja a hosszú élettartamot és megakadályozza a feldolgozás alatt álló orvosi eszközök szemcsés szennyeződését.
Yes. All Bocon systems are equipped with advanced data acquisition capabilities. Every parameter—including temperature, pressure, and fan speed—is recorded in real-time. Our software is designed to be compliant with FDA 21 CFR Part 11, providing the electronic records and audit trails necessary for international regulatory inspections.

Our Partners

Partner 1
Partner 11
Partner 2
Partner 12
Partner 7
Partner 6
Partner 3
Partner 5
Partner 9
Partner 4

Reviews

There are no reviews yet.

Be the first to review “ETO sterilizáló forró levegő rendszer”

Your email address will not be published. Required fields are marked *

Görgessen a tetejére