BOCON Hot Air Eto Sterilizer Specifications
Naleving: EN 1422, CE, ISO 13485 Support: FAT, SAT, DQ, IQ, OQ, PQ
Technische ondersteuning
Custom dimensions and automated conveyor systems are available upon request.
INQUIRE NOW →Bocon Hot Air Jacket ETO Sterilizer VS Traditional Water Jacket EO Sterilizer
| Feature / Specification | Bocon Hot Air Jacket System | Traditional Water Jacket System |
|---|---|---|
| Heating Efficiency | High: Uniformly blankets chamber and doors directly. | Lower: Indirect heat transfer via water medium. |
| Energy Consumption | Optimized: Only heats product load and air. | High: Significant energy wasted to maintain water temperature. |
| Heat-up Time (from 21°C) | Rapid: Less than 3 hours. | Slow: Requires heating large volumes of water first. |
| Maintenance Requirements | Low: Dry system, no additives or water pumps. | High: Constant monitoring of corrosion and seal replacements. |
| Corrosion Risk | Zero: Eliminates rust and mineral build-up. | High: Prone to scaling and internal corrosion. |
| Leak Impact | Minor: Non-critical for performance and easily repaired. | Critical: Causes thermal instability and safety hazards. |
| Weight & Logistics | Light: Easier rigging, installation, and lower shipping costs. | Heavy: Complex structural requirements for installation. |
Waarom kiezen voor BOCON EO-sterilisator?
Technological Excellence vs. Conventional Industry Standards.
(Uitgerust met Gas-waterafscheider)
Gebaseerd op de industriële energietarieven in China
Maintenance-free Hot Air Tech
for Multi-unit Layouts
1. Vacuümpomptechnologie
| Item | BOCON | ANDEREN |
|---|---|---|
| Vacuümpompopties | Droge schroef / waterring / oliering (meerdere opties beschikbaar) | Meestal alleen waterringpomp |
| Ultiem vacuümniveau | Tot -101,27 kPa (droge schroefpomp) | Ongeveer. -90 kPa |
| Waterverbruik | With BOCON Gas-waterafscheider: Water replaced once per week | Continu waterverbruik |
| Onderhoud | Weinig onderhoud (droge pomp), geen risico op olie-emulgatie | Frequente olieverversing (oliepomp) of beperkte prestaties |
2. Waterbesparende prestaties
Voorbeeld: Een waterringpomp van 5,5 kW verbruikt ongeveer 20 liter per minuut. Voor een sterilisatiekamer van 20 m³ met 8 vacuümcycli (elk 22 minuten) bedraagt het totale waterverbruik per cyclus 3,52 ton.
Met 14 cycli per week bedraagt het totale wekelijkse verbruik meer dan 49 ton. Na het installeren BOCON’s exclusieve Gas-waterafscheider systeem is waterverversing slechts één keer per week nodig, wat ongeveer een besparing oplevert 45 tons of water per week (approx. 180 tons per month). This is especially valuable in water-scarce regions.
3. Sterilizer Chamber Design
| Item | BOCON | ANDEREN |
|---|---|---|
| Chamber Type | Water Jacket / Air Jacket (Hot Air System) | Water Jacket Only |
| Heating Speed | Fast heating & cooling (Air Jacket) | Slower temperature transition |
| Onderhoud | No leakage risk, long service life (Air Jacket) | Water leakage risk over time |
| Space Requirement | Compact installation, suitable for multi-unit layout (Air Jacket) | Larger footprint |
4. Exclusive EG Burner System
| Item | BOCON | ANDEREN |
|---|---|---|
| Uitlaatbehandeling | Gas + Vloeibaar afvalverbranding met energieterugwinning | Alleen verbranding (gas) of alleen scrubber |
| Energieterugwinning | Rookgas op hoge temperatuur verwarmt water voor gebruik in de sterilisator | Geen energieterugwinning |
| Behandeling van vloeibaar afval | Geïntegreerde verbranding van vloeibaar afval | De scrubber kan geen vloeibaar afval behandelen |
5. Centralized Heating System
| Item | BOCON | ANDEREN |
|---|---|---|
| Systeemontwerp | Centrale verwarming met dubbele pompredundantie | Enkelvoudige waterverwarmingsunit |
| Systeemstabiliteit | De back-uppomp zorgt voor een continue werking | Het systeem stopt als de pomp uitvalt |
| Sollicitatie | Geschikt voor meerdere sterilisatoren in één werkplaats | Individuele verwarming per eenheid |
Full Technical Specifications & Properties
BOCON Hot Air ETO Sterilizer System Details
| Feature Category | Technical Specification |
|---|---|
| STANDARDS & PHYSICAL ACCESS | |
| System Design Standards | EN1422, ISO11135-2014 |
| Door Configuration | 2 Doors; Pneumatic translation seal (Default); Optional: Rotary or Lifting |
| CONTROL SYSTEM & DATA INTEGRITY | |
| System Control Mode | Soft Manual & Full-Automatic |
| Data Recording | Interval mode & Warning triggered mode; Continuous curve recording |
| Data Storage Lifecycle | 10 Years (Secure HDD Storage) |
| Data Processing | PC Monitoring & Specialized Sterilization Data Software |
| SENSORS & PRECISION | |
| Temp Control Precision | Inside: ±3°C | Wall: ±5°C (Res: 0.1°C) |
| Pressure Management | Range: -100 to +150Kpa; Res: 0.1Kpa; Resistance: up to 80KPa (Standard) |
| Vacuum Performance | < 30 minutes (0 to -90KPa); Continuous/Stepping modes |
| Humidity Performance | 0-100%RH (non-condensing); Resolution: 0.1%RH |
| AUTOMATION & SAFETY CONNECTORS | |
| Automatic Detection | Cabinet water volume, Steam pressure, and Vacuum pump monitoring |
| Safety Alerts | Real-time display & warning for insufficient steam or pressure |
| System Protection | Nitrogen protection (Optional/Auto); Tail gas treatment (Auto-control) |
| Exhaust Control | In-door and Out-door air exhausting with automatic valve control |
| GAS RECIPES & PROCESS | |
| Supported Gas Recipes | Mixed Gas (CO2/EO mixtures: 70/30, 20/80, 10/90) and Pure EO (with N2) |
| Time Management | 0-99 hours; Resolution: 1 min |
Technical FAQ