3.4.1 eto sterilizer machine Temperature Setting Range
The temperature setting range for the eto sterilizer is: 30 to 70°C
Comprender u rendimiento le esterilizador ETO: claves utia'al u eficiencia Xook asab
If a leak is detected in the eto sterilizer dosing pipeline during the administration process, immediately close the medication bottle, switch and the dosing valve on the main unit. Turn on the axial fan to ensure proper ventilation, and then proceed with repairs.
Ch'a'iko'ob fugas óxido etileno ka ku meyaj le esterilizador eto Xook asab
Note: Regardless of whether the equipment is in normal operation, malfunction, or maintenance state, if personnel need to enter the
Requisitos ti' seguridad uti'al u u óxido etileno ti' le esterilización Xook asab
Note 1: The Ethylene Oxide sterilization conditions must be obtained through validation confirmation and should be verified with monitoring and
Rendimiento eliminación microbiana esterilizadores óxido etileno Xook asab
The temperature of representative areas on the inner surfaces should be measured and recorded using temperature recording instruments that comply with the requirements of Appendix B.
eto sterilization Chamber Temperature Distribution Testing Xook asab
Appearance Inspection: Check the main unit, control rack, and electrical control cabinet for any damage on the surface.
Preparatory Work Before eto Sterilization Xook asab
Start cycle phase(Select parameters/sterilization recipe) Serial number Potentially risky content Risk assessment under existing process conditions Risk assessment of the
EO sterilization equipment and process characteristic patterns and effect analysis Xook asab
9.1 During ETO Sterilization, operators are not allowed to leave the operating area and must continuously observe the ETO Sterilization process. If any abnormal phenomena occur, the machine must be immediately shut down, and the power supply should be cut off for inspection.
Náakake' u yaak'il ti' mantenimiento utia'al u esterilizadores ETO Xook asab
For the purposes of this document, the following terms and definitions apply in ethylene oxide sterilization 3.1 Aeration part of
Términos ka definiciones u esterilización tumen gas eto Xook asab