Sistema di aria calda per sterilizzatore ETO

Advanced Air-Jacketed Heating Technology

One of Bocon’s core engineering breakthroughs is our signature Air-Jacketed Heating System. Unlike traditional hot water jacket designs, Bocon utilizes a sophisticated hot air circulation system to maintain chamber temperature. This innovative approach offers a superior alternative to conventional systems, delivering significant advantages in operational safety, thermal precision, and long-term maintenance efficiency. By choosing air over water, we provide our clients with a cleaner, more reliable, and energy-efficient sterilization environment.

BOCON Hot Air Eto Sterilizer Specifications

Conformità: EN 1422, CE, ISO 13485 Support: FAT, SAT, DQ, IQ, OQ, PQ

Support d'ingegneria

Custom dimensions and automated conveyor systems are available upon request.

INQUIRE NOW

Bocon Hot Air Jacket ETO Sterilizer VS Traditional Water Jacket EO Sterilizer

Feature / Specification Bocon Hot Air Jacket System Traditional Water Jacket System
Heating Efficiency High: Uniformly blankets chamber and doors directly. Lower: Indirect heat transfer via water medium.
Energy Consumption Optimized: Only heats product load and air. High: Significant energy wasted to maintain water temperature.
Heat-up Time (from 21°C) Rapid: Less than 3 hours. Slow: Requires heating large volumes of water first.
Maintenance Requirements Low: Dry system, no additives or water pumps. High: Constant monitoring of corrosion and seal replacements.
Corrosion Risk Zero: Eliminates rust and mineral build-up. High: Prone to scaling and internal corrosion.
Leak Impact Minor: Non-critical for performance and easily repaired. Critical: Causes thermal instability and safety hazards.
Weight & Logistics Light: Easier rigging, installation, and lower shipping costs. Heavy: Complex structural requirements for installation.

Perchè sceglie u Sterilizzatore BOCON EO?

Technological Excellence vs. Conventional Industry Standards.

180 tunnillati / mese Acqua salvata per una camera di 20 m³
(Dotatu di separatore gas-acqua)
RMB 230,000 / annu Risparmia di energia elettrica (unità di 100 m³)
Basatu nantu à i Tassi di Potenza Industriale Chine
Air Jacket System Bocon Exclusive
Maintenance-free Hot Air Tech
Centralized Heating Stabilità ridondante di doppia pompa
for Multi-unit Layouts

1. Vacuum Pump Technology

Articulu BOCON ALTRI
Opzioni di pompa di vacuum Vite secca / Anellu d'acqua / Anellu d'oliu (Opzioni multiple dispunibili) Di solitu solu a pompa di l'acqua
Livellu di Vacuum Ultimate Finu à -101,27 kPa (pompa a vite secca) Circa. -90 kPa
Cunsumu d'acqua With BOCON Separatore gas-acqua: Water replaced once per week Cunsumu cuntinuu d'acqua
Mantenimentu Mantenimentu bassu (pompa secca), Nisun risicu di emulsificazione d'oliu Cambio d'oliu frequente (pompa d'oliu) o prestazioni limitate

2. Rendimentu Water-Saving

3. Sterilizer Chamber Design

Articulu BOCON ALTRI
Chamber Type Water Jacket / Air Jacket (Hot Air System) Water Jacket Only
Heating Speed Fast heating & cooling (Air Jacket) Slower temperature transition
Mantenimentu No leakage risk, long service life (Air Jacket) Water leakage risk over time
Space Requirement Compact installation, suitable for multi-unit layout (Air Jacket) Larger footprint

4. Exclusive EG Burner System

Articulu BOCON ALTRI
Trattamentu Exhaust Combustione di rifiuti di gas + liquidu cù ricuperazione di energia Solu combustione (gas) o solu scrubber
Recuperazione di energia U gasu di fume à alta temperatura riscalda l'acqua per l'usu di sterilizzatore Nisuna ricuperazione di energia
Trattamentu di rifiuti liquidi Combustione integrata di rifiuti liquidi Scrubber ùn pò micca trattà i rifiuti liquidi

5. Centralized Heating System

Articulu BOCON ALTRI
Disegnu di u Sistema Riscaldamentu centralizatu cù doppia pompa di ridondanza Unità di riscaldamentu d'acqua unica
Stabilità di u sistema A pompa di salvezza assicura un funziunamentu cuntinuu U sistema si ferma se a pompa falla
Applicazione Adatta per più sterilizzatori in un attellu Riscaldamentu individuale per unità

Full Technical Specifications & Properties

Detaglii di u Sistema di Sterilizzatore BOCON Hot Air ETO

Categoria di funziunalità Specificazione tecnica
STANDARDS & PHYSICAL ACCESS
Standard di cuncepimentu di u sistema EN 1422, ISO 11135-2014
Cunfigurazione di a porta 2 Porte; Sigillo di traduzzione pneumatica (Default); Opcional: Rotary o Lifting
CONTROL SYSTEM & DATA INTEGRITY
Modu di cuntrollu di u sistema Soft Manual & Full-Automatic
Registrazione di dati Interval mode & Warning triggered mode; Continuous curve recording
Ciclu di vita di u almacenamentu di dati 10 anni (Almacenamiento Secure HDD)
Trattamentu di dati PC Monitoring & Specialized Sterilization Data Software
SENSORS & PRECISION
Temp Control Precision Inside: ±3°C | Wall: ±5°C (Res: 0.1°C)
Pressure Management Range: -100 to +150Kpa; Res: 0.1Kpa; Resistance: up to 80KPa (Standard)
Vacuum Performance < 30 minutes (0 to -90KPa); Continuous/Stepping modes
Humidity Performance 0-100%RH (non-condensing); Resolution: 0.1%RH
AUTOMATION & SAFETY CONNECTORS
Automatic Detection Cabinet water volume, Steam pressure, and Vacuum pump monitoring
Safety Alerts Real-time display & warning for insufficient steam or pressure
System Protection Nitrogen protection (Optional/Auto); Tail gas treatment (Auto-control)
Exhaust Control In-door and Out-door air exhausting with automatic valve control
GAS RECIPES & PROCESS
Supported Gas Recipes Mixed Gas (CO2/EO mixtures: 70/30, 20/80, 10/90) and Pure EO (with N2)
Time Management 0-99 hours; Resolution: 1 min
Customized solutions for high-pressure chambers (>80KPa) and specific gas concentrations are available.

Technical FAQ

Expert insights into Bocon EtO Sterilization Hot Air Circulation Systems

EtO sterilization depends on the "Big Four" parameters: Gas concentration, Humidity, Time, and Temperature. Bocon's Hot Air System ensures that heat and moisture are distributed uniformly throughout the entire chamber load. This high-efficiency circulation eliminates cold spots and ensures that the EtO gas can penetrate dense medical device packaging effectively, regardless of their position in the sterilization chamber.
Our systems are engineered for high-precision thermal stability. We typically achieve a temperature uniformity of ±1°C or better within the chamber volume. This level of control is managed via advanced Siemens PLC controllers and high-accuracy RTD sensors, ensuring the process remains within the validated range required by ISO 11135 standards.
Since EtO is highly flammable and explosive, Bocon utilizes ATEX or IECEx-certified explosion-proof fans and specialized heating elements. The hardware is designed to prevent spark generation. Furthermore, the system is interlocked with the control software to ensure that the heating process only operates when gas concentrations are within safe levels, often involving nitrogen dilution as a safety cushion.
Absolutely. We provide modular solutions ranging from 1m³ laboratory units to 100m³ large-scale industrial chambers. We calculate the required thermal load and air exchange rates based on your specific product density and chamber volume to ensure optimal performance for your sterilization cycles.
To maintain medical-grade cleanliness and resist corrosion from sterilization gases, Bocon uses high-quality SS304 or SS316L stainless steel for all internal ducting, fan blades, and chamber surfaces. This ensures longevity and prevents any particulate contamination of the medical devices being processed.
Yes. All Bocon systems are equipped with advanced data acquisition capabilities. Every parameter—including temperature, pressure, and fan speed—is recorded in real-time. Our software is designed to be compliant with FDA 21 CFR Part 11, providing the electronic records and audit trails necessary for international regulatory inspections.

I nostri Partenarii

Partner 1
Partner 11
Partner 2
Partner 12
Partner 7
Partner 6
Partner 3
Partner 5
Partner 9
Partner 4

Critiche

Ùn ci sò ancu recensioni.

Siate u primu à scrive "Sistema di aria calda per sterilizzatore ETO”

U vostru indirizzu email ùn serà micca publicatu. I campi obbligatori sò marcati *

Scorri à cima