Fabricante máquinas estériles ETO ti' China
Hangzhou Bocon Mechanical and Electrical Equipment Co., Ltd( eto sterile machine manufacturer in china) was established in 2006. The office […]
Fabricante máquinas estériles ETO ti' China Xook asab
Hangzhou Bocon Mechanical and Electrical Equipment Co., Ltd( eto sterile machine manufacturer in china) was established in 2006. The office […]
Fabricante máquinas estériles ETO ti' China Xook asab
Le esterilizador gas eto u 30 m³ consta u carcasa le esterilizador, le nu'ukulil auxiliar (dispositivo calentamiento yéetel ciclo térmico, dispositivo extracción ti' le vacío, dispositivo dosificación yéetel vaporización, dispositivo humidificación, dispositivo sellado, dispositivo procesamiento gas residual) yéetel le dispositivo monitoreo yéetel kaambalil yo'osal.
Esterilizador gas ETO u 30 m³ Xook asab
8.4.1 Closing the eto gas sterilizer Discharge Door 8.4.2 Opening the Loading Door 8.4.3 Loading Sterilization Items Use a forklift
Bix kuuch le producto esterilización ka ku meyaj juntúul esterilizador gas eto Xook asab
The installation and layout diagram of the ethylene oxide eto sterilizer can be found in Appendix C, Figure C.1. 7.1
Náakake' u yaak'il ti' instalación le esterilizador óxido etileno Xook asab
Le esterilizador eto ti' 12m3 táan ts'o'oksik ti' túuxtik k cliente
Le esterilizador eto ti' 12m3 táan ts'o'oksik ti' túuxtik k cliente Xook asab
3.4.1 eto sterilizer machine Temperature Setting Range
The temperature setting range for the eto sterilizer is: 30 to 70°C
Comprender u rendimiento le esterilizador ETO: claves utia'al u eficiencia Xook asab
If a leak is detected in the eto sterilizer dosing pipeline during the administration process, immediately close the medication bottle, switch and the dosing valve on the main unit. Turn on the axial fan to ensure proper ventilation, and then proceed with repairs.
Ch'a'iko'ob fugas óxido etileno ka ku meyaj le esterilizador eto Xook asab
Note: Regardless of whether the equipment is in normal operation, malfunction, or maintenance state, if personnel need to enter the
Requisitos ti' seguridad uti'al u u óxido etileno ti' le esterilización Xook asab
Note 1: The Ethylene Oxide sterilization conditions must be obtained through validation confirmation and should be verified with monitoring and
Rendimiento eliminación microbiana esterilizadores óxido etileno Xook asab
The temperature of representative areas on the inner surfaces should be measured and recorded using temperature recording instruments that comply with the requirements of Appendix B.
eto sterilization Chamber Temperature Distribution Testing Xook asab